Küba DE professional. Powerful ceiling mounted air cooler for commercial applications

Similar documents
ECOCIAT. Domestic hot water heat recovery unit

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

RPV - RP - RA air handling units

Split units TH with hermetic compressors

Low Profile Unit Cooler

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Transformer oil cooler ALFA A02

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Clinic Washer-Disinfectors. Washer-Disinfector Line

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

KONRAD. Hybrid Fancoil Series

SECTION MORTUARY REFRIGERATORS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Solar Hot Water Heaters

Technical data. Danfoss DHP-A

SWIMMING POOL HEAT PUMP Owners Manual

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Solenoid valves Type EVU

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

CEILING CASSETTE FAN COIL UNIT

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Local Dealer:

How To Understand Evaporator

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

MAC-120HE-01 Air-Cooled Chiller

CRAC Precision climate control units for data centres

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

SWIMMING POOL HEAT PUMP

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Refrigeration Compressed Air Dryer Buran Ultrapulse

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

DRYPOINT RA REFRIGERATION DRYER RANGE

Under sill units. Type FSL-B-ZAS

HDA

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Defining Quality. Building Comfort. Heating and Cooling Coils

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Küba High Performance Air Coolers. Küba Blue Line Freshness that lasts longer. Küba Green Line simple reliable fresh. Küba

york air-conditioning products Residential & VRF News 2015

The natural ombination

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

3/2-way Solenoid Valve, direct-acting, NC or NO

Explosion-Proof Electric Unit Heaters

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Air Conditioners Technical Data

Morgue refrigeration unit

ThermoStar Refrigeration Air Dryers

marine/bespoke split applications

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air


Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Compact pressure switch Flameproof enclosure Ex d Model PCA

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Coldrooms designed for your application

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Versati Air to Water Heat Pump

Installation Manual CLIFC Fan & Coil Variable Speed

CoolTeg Plus Chilled Water (CW) version: AC-TCW

MUELLER FALLING FILM CHILLERS

AIR CONDITIONING TECHNOLOGY

Chilled Water Fan Coil Unit

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

CRN A-F-G-E-HQQE 3x400D 50 HZ

TWE+TTA TWE+TWA T.R.

Vacuum drying oven for non-flammable solvents

Are these noise cancelling devices needed to make your chiller quiet??

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Daikin Altherma hybrid heat pump. The natural combination

Drain Back systems Made in Germany

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

HERZ-Thermal Actuators

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

SMG. P/N _B NSF Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. April Spanish French

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Series 8146/5-V37 and Series 8150/5-V37

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

MEMBRANE VACUUM MINI PUMPS

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

Transcription:

Powerful ceiling mounted air cooler for commercial applications engineering for a better world GEA Heat Exchangers

Powerful ceiling mounted air cooler for commercial applications Optimal utilisation of space Standard version has drip tray hinging down Large cooling power range Type designation code 1 2 3 4 5 6 DE A E 07 1 D 1 Model range designation 2 Fin spacing 3 Electric defrost 4 Size 5 Number of fans 6 Generation Code [ 2 ]

Capacity range (for SC2) 1,5 kw 9,4 kw Temperature range (t L1 ) -30 C 0 C +20 C Number of fans Content Application benefits for contractors and operators... 4 Basic version... 6 Technical data DEA (E)... 8 Technical data DEB (E)... 8 Dimensions, weights, electric defrost, drain... 9 Variants... 10 Accessories... 11 to [ 3 ]

Applications Commercial applications Small rooms and low ceilings Open sales areas Low noise a requirement Küba DE professional Application benefits for contractors and operators The Küba DE professional is up to even the most demanding applications. Whether aggressive ambient air, critical storage conditions or constant exchange of air: For fine-tuned cooling reliability, the high-performance evaporator offers variable corrosion protection, options for defrosting solutions and fan types to suit the requirements. The Küba DE professional is optimal for: Cold rooms which are accessed frequently and therefore regularly exchange air with the outside Air containing aggressive particles which may be a by-product of industrial cooling processes (salts, organic acids in pickling rooms, organic acids or amines in meat and sausages) The Küba DE professional is the obvious space saving yet powerful ceiling mounted evaporator with draught-free air flow. [ 4 ] Küba DE professional GEA Küba Blue Line

from the GEA Küba Blue Line production range The size of the store and type of stored goods are decisive in the selection of air coolers. Depending on configuration, applications may range from normal cooling to deep freezing down to -30 C. For high turnover of goods and long storage times, the Küba DE professional is the benchmark in terms of efficiency and reliability. If the storage rooms are frequently accessed to remove or store goods, the cooling power of the evaporator must be dimensioned to ensure that the indoor temperature distribution remains constant. Conditions changing frequently from dry, to moist, to cold and to warm will create high corrosive stress. The lower temperature on the air cooler surfaces will result in condensate formation on these surfaces which will in turn attract aggressive salts or cleaning agent particles in the cold room air. It is important that regulatory hygiene guidelines are complied with. The Küba DE professional has a hinged drip tray and removable side panels for simple, fast and cost-effective cleaning. We can naturally also offer the Küba DE professional with EC and AC fans. Please contact your GEA Küba sales consultant for an optimised design and savings through improved energy efficiency. The Küba DE professional is the ideal air cooler for this application. The decisive factor is the aligned tubing which will produce more cooling power per surface area than standard air coolers. The compact high-performance ceiling mounted evaporator ensures that the air is uniformly distributed, thereby ensuring that the room temperature is maintained throughout the cold room, even in the corners. Küba DE professional GEA Küba Blue Line [ 5 ]

Basic version Casing Smooth aluminum; zinc coated steel High grade powder-coating, food-safe, papyrus white, RAL 9018 End plates, stucco aluminium, not coated Food-safe Easy to clean Best quality powder coated edges Compact design Hinged drip tray and removable side panels Double drip tray Stainless steel mounting material Plastic drain Heat exchanger for direct expansion Heat exchanger with aligned tube pattern; internally grooved special copper tubes (drawn oxygen-free), according to DIN EN 12735-1,2; diameter: 15 mm; with closed pure-aluminum HFE fins Fin spacing: A = 4,5 mm B = 7 mm Fins flared to form-fit the core tube Highly effective heat transfer and compact design Series DE-F: HFC / CO2 Küba-CAL refrigerant distributors for multiple injections Tubing: special copper piping with inner fins; Fins: Al; End plates: Al Series DE-G: Glycol Tubing: Cu smooth; Fins: Al; End plates: Al Series DE-N: with pump /NH3 Distribution tubes for multi injections Tubing: VA; Fins: Al; End plates: Al Electric defrost Heaters with CrNi steel sleeve Vapour-tight connections Mains voltage: 230 V-1/400V-3-Y Wired ready to connect in junction boxes Optimized tubular heater configurations ensure fast and even defrosting Fins flared to form-fit the core tube Aluminium heat pipes that ensure excellent heat transfer to the fins and thus effective defrosting cycles with optimized service life. Integrated tube bushings allow a subsequent modification to an electric defrost system. [ 6 ] Küba DE professional GEA Küba Blue Line

Fans Available fan diameter: 300 mm Permissible motor ambient temperatures: -30 C bis +60 C 230 ±10% V-1~, 50 Hz/60 Hz With built-in protector, according to VDE provisions Fans are wired to an internal distribution box Protection class: IP44 Insulation class: B Operating data can be found with Küba Select or in the technical data Controller: Phase control Transformer Delta/star Frequency converter Please observe the manufacturer s information! Motor label data * Type 50 Hz 60 Hz Ø mm rpm W A rpm W A DE 071-094 D 300 1.350 70 0,32 1.500 90 0,40 Motor data per fan * Data provided by the manufacturer Küba DE professional GEA Küba Blue Line [ 7 ]

Technical data DEA (E) A 4,5 mm Type Rating Q 0 at 50 Hz. DT1. R404 A Cooling surface Air flow Air throw Tube volume Connections Sound Fans (Operational values at 50 Hz) SC2 SC3 *** Inlet Outlet L WA Blade Current Per Fan kw kw m 2 m 3 / h m dm 3 Ø mm Ø mm db (A) Ø mm 230 ± 10% V-1 50 Hz rpm W A 1 DEA 071 D 1,9 1,5 12,9 1.100 9 2,8 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 DEA 081 D 2,1 1,7 16,1 1.070 9 3,5 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 DEA 091 D 2,3 1,9 19,3 1.035 9 4,2 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 2 3 4 DEA 072 D 3,8 3,0 25,8 2.200 11 5,6 12 x 1,0* 15 x 1,0 71 300 230 V -1 1.350 72 0,3 DEA 082 D 4,2 3,3 32,2 2.140 11 7,0 12 x 1,0* 22 x 1,0 71 300 230 V -1 1.350 72 0,3 DEA 092 D 4,7 3,7 38,6 2.070 11 8,4 10 x 1,0* 22 x 1,0 71 300 230 V -1 1.350 72 0,3 DEA 083 D 6,3 5,0 48,3 3.210 12 10,5 10 x 1,0** 22 x 1,0 73 300 230 V -1 1.350 72 0,3 DEA 093 D 7,0 5,6 57,9 3.105 12 12,6 10 x 1,0** 22 x 1,0 73 300 230 V -1 1.350 72 0,3 DEA 084 D 8,4 6,7 64,4 4.280 16 14,0 10 x 1,0** 22 x 1,0 74 300 230 V -1 1.350 72 0,3 DEA 094 D 9,4 7,5 77,2 4.140 16 16,8 10 x 1,0** 28 x 1,5 74 300 230 V -1 1.350 72 0,3 Subject to modification. Standard condition t L1 t 0 DT1 NB 2 / SC 2 0-8 8 NB 3 / SC 3-18 -25 7 Correction factors for other refrigerants Refrigerant NB 2 / SC 2 NB 3 / SC 3 R134a 1,00 0,91 R507 0,97 0,97 R22 0,95 0,95 * Single injection ** Multiple injection through Küba CAL distributor *** Throw limit at 0.5 m/s Küba DE professional Technical data DEB (E) B 7 mm Type Rating Q 0 at 50 Hz. DT1. R404 A Cooling surface Air flow Air throw Tube volume Connections Sound Fans (Operational values at 50 Hz) SC2 SC3 *** Inlet Outlet L WA Blade Current Per Fan kw kw m 2 m 3 / h m dm 3 Ø mm Ø mm db (A) Ø mm 230 ± 10% V-1 50 Hz rpm W A 1 DEB 071 D 1,5 1,2 5,4 1.280 10 2,8 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 DEB 081 D 1,8 1,4 10,6 1.220 10 3,5 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 DEB 091 D 2,0 1,6 12,7 1.120 10 4,2 12 x 1,0* 15 x 1,0 68 300 230 V -1 1.350 72 0,3 2 3 4 DEB 072 D 3,1 2,4 16,8 2.560 12 5,6 12 x 1,0* 15 x 1,0 71 300 230 V -1 1.350 72 0,3 DEB 082 D 3,6 2,9 21,2 2.440 12 7,0 12 x 1,0* 22 x 1,0 71 300 230 V -1 1.350 72 0,3 DEB 092 D 4,0 3,2 25,4 2.240 12 8,4 10 x 1,0* 22 x 1,0 71 300 230 V -1 1.350 72 0,3 DEB 083 D 5,4 4,3 31,8 3.660 14 10,5 10 x 1,0** 22 x 1,0 73 300 230 V -1 1.350 72 0,3 DEB 093 D 6,0 4,8 38,1 3.360 14 12,6 10 x 1,0** 22 x 1,0 73 300 230 V -1 1.350 72 0,3 DEB 084 D 7,2 5,7 42,4 4.880 17 14,0 10 x 1,0** 22 x 1,0 74 300 230 V -1 1.350 72 0,3 DEB 094 D 8,0 6,4 50,8 4.480 17 16,8 10 x 1,0** 28 x 1,5 74 300 230 V -1 1.350 72 0,3 Subject to modification. Standard condition t L1 t 0 DT1 NB 2 / SC 2 0-8 8 NB 3 / SC 3-18 -25 7 Correction factors for other refrigerants Refrigerant NB 2 / SC 2 NB 3 / SC 3 R134a 1,00 0,91 R507 0,97 0,97 R22 0,95 0,95 * Single injection ** Multiple injection through Küba CAL distributor *** Throw limit at 0.5 m/s [ 8 ] Küba DE professional GEA Küba Blue Line

Dimensions, weights, electric defrost, drain Type Dimensions Electrical defrost 230 V-1 / 400 V-3-Y Weights (net) Weights (gross) H B T L E 1 E 2 F Coil Tray Total DE A DEA E DEB DEB E DEA DEA E DEB DEB E D Drain mm mm mm mm mm mm mm kw kw kw kg kg kg kg kg kg kg kg inch DE 071 D 260 1.080 669 672 730-175 0,7 0,8 1,5 26 28 24 26 29 32 27 30 G ¾ DE 081 D 260 1.080 669 672 730-175 1,4 0,8 2,1 27 30 28 27 30 33 28 31 G ¾ DE 091 D 260 1.080 669 672 730-175 1,4 0,8 2,1 31 34 26 31 34 37 31 34 G ¾ DE 072 D 260 1.780 669 672 1.430-175 1,2 1,3 2,5 45 48 41 44 50 53 46 49 G ¾ DE 082 D 260 1.780 669 672 1.430-175 2,4 1,3 3,7 47 51 42 46 52 56 47 51 G ¾ DE 092 D 260 1.780 669 672 1.430-175 2,4 1,3 3,7 54 58 54 58 59 63 58 62 G ¾ DE 083 D 260 2.480 669 672 2.130 1.400 175 3,4 1,8 5,2 67 72 62 66 75 80 68 73 G ¾ DE 093 D 260 2.480 669 672 2.130 1.400 175 3,4 1,8 5,2 73 78 70 76 80 85 77 82 G ¾ DE 084 D 260 3.180 669 672 2.830 1.400 175 4,6 0,6 5,2 79 87 72 82 102 118 106 114 G ¾ DE 094 D 260 3.180 669 672 2.830 1.400 175 4,6 0,6 5,2 87 93 77 82 114 126 110 122 G ¾ Subject to modification. The dimensions are only valid for the standard model design! Note the differences in dimension among versions and accessories. Dimensional drawings Küba DE professional (1-4 motors) L F±3 E 1 315 H 206 14 D T 365 80 F±3 B ±5 E 1 14 B ±5 F±3 E 2 E 1 14 B ±5 F±3 E 2 E 1 14 B ±5 Küba DE professional GEA Küba Blue Line [ 9 ]

Variants Motor-Variants Construction-Variants V 1.33 Fans, silent version Fans 230V±10% V-1~ 50/60 Hz; 1.100 rpm Reduced air volume flow Lower sound power level V 1.50 EC fans with fixed speeds Fixed fan speed at optimal operating point V 3.09 Double-walled, insulated drip tray Prevents condensed water from forming on the bottom side of the pan, and it reduces the transfer of defrost heat into the cold rooms. V 2.05 Water / brine circulation With a large number of distributors (small pressure drop) V 1.52 EC fan with controllable speed Fans adjustable Protection against corrosion V 3.12 Stainless steel casing Special protection from salts (no chlorine) and organic acids in the cold room air V 2.06 Water / brine circulation With a small number of distributors (large pressure drop) CO 2 -Variants V 7.45 CO 2 -Direct expansion up to 45 bar operating pressure V 6.01 Corrosion protection 1 Tubing: Copper (NH3 units = stainless steel) Fins: Aluminum, epoxy-resin-coated End plates: Aluminum protective coating Casing: Aluminum/zinc coated steel, protective coating on both sides V 7.60 CO 2 -Direct expansion up to 60 bar operating pressure V 6.02 Corrosion protection 2 Tubing: Stainless steel (V2A) Fins: Aluminum, epoxy-resin-coated End plates: Stainless steel Casing: Aluminum/zinc coated steel, protective coating on both sides V 6.03 Corrosion protection 3 Tubing: Stainless steel (V2A) Fins: Aluminum End plates: Aluminum Casing: Aluminum/zinc coated steel, protective coating on on one side V 6.04 Corrosion protection 4 Tubing: Copper (NH3 units = stainless steel) Fins: Aluminum, epoxy-resin-coated End plates: Aluminum Casing: Aluminum/zinc coated steel, protective coating on on one side [ 10 ] Küba DE professional GEA Küba Blue Line

Accessories + Accessories Electric heater DEHR For air coolers with forced-draft fans, for assembly on site. Suitable for air conditioning, or heating, in the winter. For optimal heat transfer, the heater rods are fitted in Cu tube sleeves. Fully powder-coated (RAL 9018) 230 ± 10% V-1~ or 400 ± 10% V-3~ -Y Heater rods with CrNi steel sleeve Vapour-tight connections Connecting cable 1.0 mm 2 x 1000 mm Casing: steel, continuous hot-dip zinc coated Fins: aluminium Tube sleeves: Cu Selection table & dimensions: 230±10%V-1~ Dimensions Weight For type Description Current Capacity H L L 1 E F net A kw mm mm mm mm mm kg 071D HR4-70 4,7 1,1 145 755 700 733 76 1,7 081D HR4-70 4,7 1,1 145 755 700 733 76 1,7 091D HR4-70 4,7 1,1 145 755 700 733 76 1,7 072D HR4-140 9,3 2,1 145 1.433 1.400 1.433 76 3,0 082D HR4-140 9,3 2,1 145 1.433 1.400 1.433 76 3,0 092D HR4-140 9,3 2,1 145 1.433 1.400 1.433 76 3,0 083D HR4-210 14,7 3,4 145 2.133 2.100 2.133 76 4,3 093D HR4-210 14,7 3,4 145 2.133 2.100 2.133 76 4,3 084D HR4-280 18,8 4,3 145 2.855 2.800 2.833 76 5,8 094D HR4-280 18,8 4,3 145 2.855 2.800 2.833 76 5,8 F H ±3 34 L 1 E ±3 L ±3 20 65 Note: Operate only when the air cooler fans are running, to prevent the cold storage ceiling from overheating. Please observe the corresponding safety guidelines. Küba DE professional GEA Küba Blue Line [ 11 ]

We live our values. Excellence Passion Integrity Responsibility GEA-versity GEA Group is a global engineering company with multi-billion euro sales and operations in more than 50 countries. Founded in 1881, the company is one of the largest providers of innovative equipment and process technology. GEA Group is listed in the STOXX Europe 600 index. GEA Heat Exchangers GEA Küba GmbH Kühler Weg 1 82065 Baierbrunn Germany Tel.: ++49 (0) 89 / 744 73-0 Fax: ++49 (0) 89 / 744 73-107 kueba@gea.com www.kueba.com Copyright 2014 GEA Küba GmbH 0094.392BR.DED.EN Status as of 09 / 2014 Subject to technical changes