FT1000 BASE FLIGHT-TYPE DISHWASHER

Similar documents
Element D Services Plumbing

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS

WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT

Oil and Coolant Circulating Heating System. Model - OCSM

FOXAIR 60/50 ALL MODELS

Cooking at the Speed of light!

Light Duty Commercial Electric Water Heater

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

AM SELECT DISHWASHERS

Installation/Operation with Service Replacement Parts

SECTION MORTUARY REFRIGERATORS

INSTALLATION & OPERATION MANUAL FLIGHT TYPE DISHWASHERS MODELS STPC STPCW STPCW-D STBUW

KLE-115U Single Rack Undercounter Configuration Instruction Manual

Horizontal Jet Pumps 1/3-1-1/2 HP

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Commercial Gas Water Heaters

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Dehumidifier Users manual. For Models: DH45S DH65S

SIOUX HYBRID WATER HEATER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

PLUMBING & CROSS-CONNECTION CONTROL

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

CE6500 Energy Recovery Ventilator

New or Remodeled Food Service Establishment Checklist**

Bath Planning Guidelines With Access Standards

Professional dishwashers. Blue line. the environmentally friendly brand

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Commercial Electric Water Heater

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Low Profile Unit Cooler

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

IBC Tote Containment Sumps

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Fire Pump Plan Review March 2010

Commercial Gas Furnace Upflow

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Commercial Gas Water Heaters

Line to Refrigerator Ice/Water Dispenser

Utility Distribution Systems

WINDOW ROOM AIR CONDITIONER

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

RECON WATER HEATER INSTALLATION FORM

B150 Series Commercial Brewer. Direct Plumb Kit

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

ARMSTRONG AIR HEAT PUMPS

MUELLER FALLING FILM CHILLERS

Sanitary Type Electronic Flow Switches

MODEL INSTALLATION INSTRUCTIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

INSTALLATION AND SERVICE MANUAL

CEILING CASSETTE FAN COIL UNIT

NAVIEN AMERICA INC FITCH AVENUE

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

EcoStar Professional warewashing with integrated effi ciency and hygienic reliability

ECOCIAT. Domestic hot water heat recovery unit

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Diesel Engine Driven Generators Page 1 of 6

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SunMaxx Solar Filling Station Operating Instructions

French Door Refrigerator E23BC78IPS professional series

Innovent LASER Packaged Fresh Air Conditioning Units

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Frequently Asked Questions Generators

REGULATORS 175/153 Series

SECTION K - HOT WATER SUPPLY REQUIREMENTS

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Select Radiators Installation Guide

Heating Water by Direct Steam Injection

IMPORTANT SAFETY RULES TO FOLLOW

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve


CARING FOR YOUR WATER HEATER

H I G H S P I N W A S H E R E X T R A C T O R S H C 6 0 H C 6 5 H C 7 5 H C H C H C 1 6 5

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

#9. EFFECTIVE CLEANING, MAINTENANCE, AND PEST CONTROL PROGRAMS FOR YOUR HACCP PLAN

"EC" Series Electric Humidifier

Home comfort: water heating

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Transcription:

Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature alert Single point vent location 31" access on prewash, power wash and power rinse chambers; 20" access on dual rinse chamber Start and stop switches at both ends Doors open indicator Drains open indicator Door interlocks 3 1 2 H.P. prewash, 5 H.P. power wash and power rinse pump motors, all TEFC Capless wash arms Easy to remove stainless steel scrap pans and baskets 30" wide conveyor belt Dual Rinse Front and rear panels Variable speed conveyor DIRECTION OF OPERATION Right to Left Left to Right VOLTAGE 208/60/3 240/60/3 480/60/3 Other voltages available consult factory MODEL FT1000 Base Flight-Type Dishwasher OPTIONS AT EXTRA COST Electric Tank Heat Steam Tank Heat Booster Heater Electric Steam 6" higher than standard chamber Multiple conveyor choices Circuit breakers Security packages Other options available, consult factory ACCESSORIES Flanged feet Water hammer arrestor/prv (installed by others) Drain water tempering kit (installed by others) Vent connection kit Specifications, Details and Dimensions on Inside and Back. LA Research Report M660004 Complies with EPA Reduction of Lead in Drinking Water Act 2014 Meets requirements of ASSE Standard No. 1004 FLIGHT-TYPE DISHER F40350 FT1000 Base Flight-Type Dishwasher Page 1 of 12

FLIGHT-TYPE DISHER DESIGN: Fully automatic, flight-type dish machine consisting of a load section, power recirculating prewash, power wash, power rinse, and dual rinse/ final rinse section. Included with each machine will be flexible plastic strip curtains to control overspray. CONSTRUCTION: Stainless steel tank and chambers with No. 3 polish on appearance surfaces. Frame, legs and feet to be constructed of stainless steel. Inspection doors to be chamber width. PUMPS: Recirculating stainless steel pumps with stainless steel impellers. Pump housing has easy to remove coverplate for access to impeller. Wash pumps are self-draining. MOTORS: Totally enclosed fan cooled (TEFC) design with inherent overload protection. Pump motors to be 3 1 2 H.P. for prewash, 5 H.P. for power wash and power rinse, and conveyor motor to be 1 3 H.P. Available in electrical specifications of 208/60/3, 240/60/3 and 480/60/3. CONTROLS: A stainless steel control center with electronic digital controls mounted at eye level. Power On/Off and Start/Stop switches integrated into keypad. Digital display indicates door(s) open, low temperature alert, tanks/final rinse temperatures and other pertinent operating data. Additional Start/ Stop switches are located at each end of machine. Conveyor speed button included on the control center to provide for adjustable speed conveyor. FLIGHT-TYPE CONVEYOR: Stainless steel side links, tie rods and conveyor tracks. Injection molded, resilient Duraflex flight links. VENT: Indirect vent connection with integral powered fan. RECIRCULATING PRE SECTION: Prewash compartment is fitted with upper and lower wash arms. Large removable one piece perforated stainless steel screen sloped downward to deep stainless steel scrap basket. TANK HEAT: Power wash, power rinse and dual rinse tank water temperatures are thermostatically controlled. Low water protection is provided. Specify either electric or steam heat. FINAL RINSE: Easily removed final rinse arms. CONVEYOR DRIVE UNIT: Powered by a 1 3 H.P. motor. Trip mechanism provided on unload section. Jam protection is provided by load sensing switch at drive platform. Conveyor speed adjustment of 4.0 feet per minute to 8.5 feet per minute is provided on the digital display keypad. DRAINS: Manual, hand-operated, located at each tank. Page 2 of 12 F40350 FT1000 Base Flight-Type Dishwasher

FLIGHT-TYPE DISHER No other control system allows easier monitoring. The digital controls are placed in a convenient panel that lets operators verify proper operation and temperatures at a glance. Digital display indicates the unit is on, and confirms that the doors are closed. Automatic door interlocks prevent the pump and conveyor from operating if the doors are open. Easy-to-read digital display indicates accurate temperatures of the 150 F wash, 160 F power rinse, 160 F dual rinse and 180 F final rinse critical for proper HACCP system record-keeping. Stainless steel pump is built for long life. The stainless steel pump housing and impeller offer greater durability and long life. The pump motor is totally enclosed and fan cooled (TEFC) to protect it from water spray during dishroom clean-up. Scrap baskets capture food particles and are easy to clean. The sloped screens that carry scraps to the scrap baskets are steeper, so less soil gets into the tanks. The basket opening is larger for easy cleaning and basket handles have been designed for easy lift-out access. The load section also contains a removable scrap basket. All scrap baskets and strainers are stainless steel for strength and durability. The FT1000 Series saves water and energy. The unit has the lowest water and energy consumption in the industry, yet provides effective cleaning and sanitizing that meets NSF International requirements. This is achieved through a carefully balanced ratio of water flow to pressure. Insulated doors and thermal layered curtains also reduce heat loss. The unit s 58 gallons per hour rinse flow rate saves both water and the energy to heat it. Wider, variable speed conveyor offers increased throughput. The conveyor on the FT1000 Series is wider so it can handle more ware. Result: more volume and versatility, quicker work. Its speed is easily adjustable on the digital display keypad for the type of ware, soiled condition, or workforce requirements. It runs at 4.0-8.5 feet per minute. Self-draining wash pumps help keep water clean. Pumps are self-draining when the machine is shut down, so there is no residual water left in the pumps. Installation is quick and easy with modular design, minimal wiring connections, and single point vent. Modular design means the FT1000 installs quickly and reliably. The control panel is already in place, premounted to the dual rinse/final rinse section. Wiring connections are minimal, and there is only a single vent, saving time and expense. The control box uses a single plane circuitry design for easy accessibility during installation and service. The FT1000 is ready to run quickly. F40350 FT1000 Base Flight-Type Dishwasher Page 3 of 12

ELECTRIC L-R 55 3/16" 44 9/16" 18 3/4" 37 1/2" E1 E2 E6 E3 E7 E4 E8 E5 E9 9 15/16" 21 3/4" 55 11/16" 63 3/8" 134 1/2" E1 E2 E3 E4 E5 E6 E7 E8 E9 11 13/16" 3 15/16" OVER FRAME "A" 7 7/8" LOAD "B" 8' 7/16" UNLOAD "C" 3" 35 7/16" 35 7/16" 35 7/16" 25 9/16" 5 3/4" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 6" AIR GAP LOAD PRE- RINSE AUX FNL UNLOAD 81 7/8" 89 3/8" SEE NOTE (d) 62 3/4" 36 1/2" DIRECTION OF OPERATION 36 1/4" 6" FLOOR LINE FLOOR LINE NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 40 3/8" 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP MODEL NO. "A" "B" "C" FT1019 (5.5'-8'-5.5') FT1020 (6.5'-8'-5.5') FT1021 (7.5'-8'-5.5') FT1021 (5.5'-8'-7.5') FT1022 (6.5'-8'-7.5') FT1023 (7.5'-8'-7.5') FT1023 (5.5'-8'-9') FT1024 (6.5'-8'-9') FT1025 (7.5'-8'-9') FT1025 (5.5'-8'-11') FT1026 (6.5'-8'-11') FT1027 (7.5'-8'-11') FT1028 (5.5'-8'-15') FT1029 (6.5'-8'-15') FT1030 (7.5'-8'-15') FT1030 (5.5'-8'-17') FT1031 (6.5'-8'-17') FT1032 (7.5'-8'-17') 19' 2-3/8" 5' 6-15/16" 5' 7" 20' 2-1/8" 6' 6-11/16" 5' 7" 21' 1-31/32" 7' 6-17/32" 5' 7" 21' 1-7/8" 5' 6-15/16" 7' 6-1/2" 22' 1-5/8" 6' 6-11/16" 7' 6-1/2" 23' 1-15/32" 7' 6-17/32" 7' 6-1/2" 22' 9-5/8" 5' 6-15/16" 9' 2-1/4" 23' 9-3/8" 6' 6-11/16" 9' 2-1/4" 24' 9-7/32" 7' 6-17/32" 9' 2-1/4" 24' 9-1/4" 5' 6-15/16" 11' 1-7/8" 25' 9" 6' 6-11/16" 11' 1-7/8" 26' 8-27/32" 7' 6-17/32" 11' 1-7/8" 28' 4-9/16" 5' 6-15/16" 14' 9-3/16" 29' 4-5/16" 6' 6-11/16" 14' 9-3/16" 30' 4-5/32" 7' 6-17/32" 14' 9-3/16" 30' 4-1/8" 5' 6-15/16" 16' 8-3/4" 31' 3-7/8" 6' 6-11/16" 16' 8-3/4" 32' 3-23/32" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" Page 4 of 12 F40350 FT1000 Base Flight-Type Dishwasher

ELECTRIC L-R SERVICE CONNECTION WITH CIRCUIT BREAKERS (2) SERVICE CONNECTIONS AS SHOWN BELOW MOTORS,CONTROLS, RINSE & BOOSTER HEAT (TB1) 208/60/3 161.3 200 200 240/60/3 156.0 200 200 480/60/3 86.5 125 125 & DUAL RINSE HEAT (TB2) DEVICE 208/60/3 87.0 125 125 240/60/3 83.0 125 125 480/60/3 41.5 60 60 SERVICE CONNECTION W/O CIRCUIT BREAKERS (5) SERVICE CONNECTIONS AS SHOWN BELOW ELECTRIC TANK HEAT, DUAL RINSE (1) 7 KW CONNECTION AS SHOWN BELOW 208/60/3 21.0 25 25 240/60/3 20.0 25 25 480/60/3 10.0 15 15 ELECTRIC TANK HEAT, RINSE (1) 20 KW CONNECTION AS SHOWN BELOW 208/60/3 60.0 80 80 240/60/3 57.3 80 80 480/60/3 28.6 40 40 ELECTRIC TANK HEAT, (1) 22 KW CONNECTION AS SHOWN BELOW 208/60/3 66.0 80 80 240/60/3 63.0 80 80 480/60/3 31.5 45 45 ELECTRIC BOOSTER (1) 18 KW CONNECTION AS SHOWN BELOW 208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35 MOTORS AND CONTROLS DEVICE 208-240/60/3 47.2 60 60 480/60/3 32.1 40 40 Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. VENTILATION NOTES: (d) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, E4 ELECTRIC TANK HEAT CONNECTION, RINSE TANK, 20 KW. E5 ELECTRIC TANK HEAT CONNECTION, TANK, 22 KW. E6 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 7KW. E7 ELECTRIC TANK HEAT CONNECTION, BOOSTER, 18KW. WITH CIRCUIT BREAKERS: E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 2" CONDUIT, 79-1/8" AFF E9 ELECTRIC CONNECTION, HEAT & DUAL RINSE HEAT (TB2) 1-1/4" CONDUIT, 79-1/8" AFF PLUMBING CONNECTIONS: COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF Pressure gauge not required on pumped rinse machines. MODEL: ELECTRIC L-R OPERATION 00-949503 REV A2 F40350 FT1000 Base Flight-Type Dishwasher Page 5 of 12

ELECTRIC R-L 52" 44 9/16" 23 3/4" 55 11/16" 18 3/4" 37 1/2" 63 3/8" 9 15/16" 134 1/2" E1 E2 E6 E3 E7 E4 E8 E5 E9 11 13/16" E1 E2 E3 E4 E5 E6 E7 E8 E9 7 7/8" OVER FRAME "A" 3 15/16" UNLOAD "C" 8' 7/16" LOAD "B" 25 9/16" 35 7/16" 35 7/16" 35 7/16" 3" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 5 3/4" 6" AIR GAP 89 3/8" SEE NOTE (d) 81 7/8" UNLOAD FNL AUX RINSE PRE- LOAD 62 3/4" 36 1/4" DIRECTION OF OPERATION 36 1/2" 6" FLOOR LINE NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 40 3/8" FLOOR LINE 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP MODEL NO. "A" "B" "C" FT1019 (5.5'-8'-5.5') FT1020 (6.5'-8'-5.5') FT1021 (7.5'-8'-5.5') FT1021 (5.5'-8'-7.5') FT1022 (6.5'-8'-7.5') FT1023 (7.5'-8'-7.5') FT1023 (5.5'-8'-9') FT1024 (6.5'-8'-9') FT1025 (7.5'-8'-9') FT1025 (5.5'-8'-11') FT1026 (6.5'-8'-11') FT1027 (7.5'-8'-11') FT1028 (5.5'-8'-15') FT1029 (6.5'-8'-15') FT1030 (7.5'-8'-15') FT1030 (5.5'-8'-17') FT1031 (6.5'-8'-17') FT1032 (7.5'-8'-17') 19' 2-3/8" 5' 6-15/16" 5' 7" 20' 2-1/8" 6' 6-11/16" 5' 7" 21' 1-31/32" 7' 6-17/32" 5' 7" 21' 1-7/8" 5' 6-15/16" 7' 6-1/2" 22' 1-5/8" 6' 6-11/16" 7' 6-1/2" 23' 1-15/32" 7' 6-17/32" 7' 6-1/2" 22' 9-5/8" 5' 6-15/16" 9' 2-1/4" 23' 9-3/8" 6' 6-11/16" 9' 2-1/4" 24' 9-7/32" 7' 6-17/32" 9' 2-1/4" 24' 9-1/4" 5' 6-15/16" 11' 1-7/8" 25' 9" 6' 6-11/16" 11' 1-7/8" 26' 8-27/32" 7' 6-17/32" 11' 1-7/8" 28' 4-9/16" 5' 6-15/16" 14' 9-3/16" 29' 4-5/16" 6' 6-11/16" 14' 9-3/16" 30' 4-5/32" 7' 6-17/32" 14' 9-3/16" 30' 4-1/8" 5' 6-15/16" 16' 8-3/4" 31' 3-7/8" 6' 6-11/16" 16' 8-3/4" 32' 3-23/32" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" Page 6 of 12 F40350 FT1000 Base Flight-Type Dishwasher

ELECTRIC R-L SERVICE CONNECTION WITH CIRCUIT BREAKERS (2) SERVICE CONNECTIONS AS SHOWN BELOW MOTORS,CONTROLS, RINSE & BOOSTER HEAT (TB1) 208/60/3 161.3 200 200 240/60/3 156.0 200 200 480/60/3 86.5 125 125 & DUAL RINSE HEAT (TB2) DEVICE 208/60/3 87.0 125 125 240/60/3 83.0 125 125 480/60/3 41.5 60 60 SERVICE CONNECTION W/O CIRCUIT BREAKERS (5) SERVICE CONNECTIONS AS SHOWN BELOW ELECTRIC TANK HEAT, DUAL RINSE (1) 7 KW CONNECTION AS SHOWN BELOW 208/60/3 21.0 25 25 240/60/3 20.0 25 25 480/60/3 10.0 15 15 ELECTRIC TANK HEAT, RINSE (1) 20 KW CONNECTION AS SHOWN BELOW 208/60/3 60.0 80 80 240/60/3 57.3 80 80 480/60/3 28.6 40 40 ELECTRIC TANK HEAT, (1) 22 KW CONNECTION AS SHOWN BELOW 208/60/3 66.0 80 80 240/60/3 63.0 80 80 480/60/3 31.5 45 45 ELECTRIC BOOSTER (1) 18 KW CONNECTION AS SHOWN BELOW 208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35 MOTORS AND CONTROLS DEVICE 208-240/60/3 47.2 60 60 480/60/3 32.1 40 40 Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. VENTILATION NOTES: (d) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, E4 ELECTRIC TANK HEAT CONNECTION, RINSE TANK, 20 KW. E5 ELECTRIC TANK HEAT CONNECTION, TANK, 22 KW. E6 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 7KW. E7 ELECTRIC TANK HEAT CONNECTION, BOOSTER, 18KW. WITH CIRCUIT BREAKERS: E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 2" CONDUIT, 79-1/8" AFF E9 ELECTRIC CONNECTION, HEAT & DUAL RINSE HEAT (TB2) 1-1/4" CONDUIT, 79-1/8" AFF PLUMBING CONNECTIONS: COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF Pressure gauge not required on pumped rinse machines. MODEL: ELECTRIC R-L OPERATION 00-949502 REV A2 F40350 FT1000 Base Flight-Type Dishwasher Page 7 of 12

STEAM L-R 55 3/16" P6 15 11/16" 18 3/4" P6 P4 14 11/16" P5 5 15/16" 68 13/16" P6 33 3/8" 2 15/16" P6 44 9/16" 11 9/16" P5 21 3/4" P7 P3 37 1/2" E1 E2 E3 23 1/8" P4 23" 28 15/16" 55 11/16" 63 3/8" 9 15/16" 134 1/2" E1 E2 E3 11 13/16" P7 28 7/16" P3 38 1/4" 3 15/16" OVER FRAME "A" 7 7/8" LOAD "B" 8' 7/16" 3" 35 7/16" 35 7/16" 35 7/16" 25 9/16" UNLOAD "C" 5 3/4" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 6" AIR GAP LOAD PRE- RINSE AUX FNL UNLOAD 81 7/8" 89 3/8" SEE NOTE (e) 62 3/4" 36 1/2" DIRECTION OF OPERATION 36 1/4" 6" FLOOR LINE Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. Pressure gauge not required on pumped rinse machines. Page 8 of 12 F40350 FT1000 Base Flight-Type Dishwasher

STEAM L-R MODEL NO. "A" "B" "C" FT1019 (5.5'-8'-5.5') FT1020 (6.5'-8'-5.5') FT1021 (7.5'-8'-5.5') FT1021 (5.5'-8'-7.5') FT1022 (6.5'-8'-7.5') FT1023 (7.5'-8'-7.5') FT1023 (5.5'-8'-9') FT1024 (6.5'-8'-9') FT1025 (7.5'-8'-9') FT1025 (5.5'-8'-11') FT1026 (6.5'-8'-11') FT1027 (7.5'-8'-11') FT1028 (5.5'-8'-15') FT1029 (6.5'-8'-15') FT1030 (7.5'-8'-15') FT1030 (5.5'-8'-17') FT1031 (6.5'-8'-17') FT1032 (7.5'-8'-17') SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS MOTORS AND CONTROLS DEVICE 208-240/60/3 47.2 60 60 480/60/3 32.1 40 40 19' 2-3/8" 5' 6-15/16" 5' 7" 20' 2-1/8" 6' 6-11/16" 5' 7" 21' 1-31/32" 7' 6-17/32" 5' 7" 21' 1-7/8" 5' 6-15/16" 7' 6-1/2" 22' 1-5/8" 6' 6-11/16" 7' 6-1/2" 23' 1-15/32" 7' 6-17/32" 7' 6-1/2" 22' 9-5/8" 5' 6-15/16" 9' 2-1/4" 23' 9-3/8" 6' 6-11/16" 9' 2-1/4" 24' 9-7/32" 7' 6-17/32" 9' 2-1/4" 24' 9-1/4" 5' 6-15/16" 11' 1-7/8" 25' 9" 6' 6-11/16" 11' 1-7/8" 26' 8-27/32" 7' 6-17/32" 11' 1-7/8" 28' 4-9/16" 5' 6-15/16" 14' 9-3/16" 29' 4-5/16" 6' 6-11/16" 14' 9-3/16" 30' 4-5/32" 7' 6-17/32" 14' 9-3/16" 30' 4-1/8" 5' 6-15/16" 16' 8-3/4" 31' 3-7/8" 6' 6-11/16" 16' 8-3/4" 32' 3-23/32" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. (d) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE AT THE DISHER, CONTACT SALES ENGINEERING. VENTILATION NOTES: (e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE 40 3/8" WITH & W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, FLOOR LINE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP PLUMBING CONNECTIONS: COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF P3 COMMON STEAM CONNECTION (TANK HEAT & STEAM BOOSTER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE) see note (d). P4 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF P5 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF P6 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF P7 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF MODEL: STEAM L-R OPERATION 00-949503 REV A2 VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF F40350 FT1000 Base Flight-Type Dishwasher Page 9 of 12

STEAM R-L P3 P4 11 5/8" P7 P5 60" 44 9/16" 14 5/8" P4 5 7/8" P5 88 3/4" 53 3/8" P6 22 5/8" P6 P6 P6 15 11/16" 28 15/16" 23 1/8" 23 3/4" 23 1/16" 55 11/16" 63 3/8" 18 3/4" 37 1/2" E1 E2 E3 9 15/16" P7 P3 28 7/16" 38 1/4" 11 13/16" E1 E2 E3 134 1/2" 7 7/8" OVER FRAME "A" 3 15/16" UNLOAD "C" 8' 7/16" LOAD "B" 25 9/16" 35 7/16" 35 7/16" 35 7/16" 3" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 5 3/4" 6" AIR GAP 89 3/8" SEE NOTE (e) 81 7/8" UNLOAD FNL AUX RINSE PRE- LOAD 62 3/4" 36 1/4" DIRECTION OF OPERATION 36 1/2" 6" FLOOR LINE Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. Pressure gauge not required on pumped rinse machines. Page 10 of 12 F40350 FT1000 Base Flight-Type Dishwasher

STEAM R-L MODEL NO. "A" "B" "C" FT1019 (5.5'-8'-5.5') FT1020 (6.5'-8'-5.5') FT1021 (7.5'-8'-5.5') FT1021 (5.5'-8'-7.5') FT1022 (6.5'-8'-7.5') FT1023 (7.5'-8'-7.5') FT1023 (5.5'-8'-9') FT1024 (6.5'-8'-9') FT1025 (7.5'-8'-9') FT1025 (5.5'-8'-11') FT1026 (6.5'-8'-11') FT1027 (7.5'-8'-11') FT1028 (5.5'-8'-15') FT1029 (6.5'-8'-15') FT1030 (7.5'-8'-15') FT1030 (5.5'-8'-17') FT1031 (6.5'-8'-17') FT1032 (7.5'-8'-17') SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS MOTORS AND CONTROLS DEVICE 208-240/60/3 47.2 60 60 480/60/3 32.1 40 40 19' 2-3/8" 5' 6-15/16" 5' 7" 20' 2-1/8" 6' 6-11/16" 5' 7" 21' 1-31/32" 7' 6-17/32" 5' 7" 21' 1-7/8" 5' 6-15/16" 7' 6-1/2" 22' 1-5/8" 6' 6-11/16" 7' 6-1/2" 23' 1-15/32" 7' 6-17/32" 7' 6-1/2" 22' 9-5/8" 5' 6-15/16" 9' 2-1/4" 23' 9-3/8" 6' 6-11/16" 9' 2-1/4" 24' 9-7/32" 7' 6-17/32" 9' 2-1/4" 24' 9-1/4" 5' 6-15/16" 11' 1-7/8" 25' 9" 6' 6-11/16" 11' 1-7/8" 26' 8-27/32" 7' 6-17/32" 11' 1-7/8" 28' 4-9/16" 5' 6-15/16" 14' 9-3/16" 29' 4-5/16" 6' 6-11/16" 14' 9-3/16" 30' 4-5/32" 7' 6-17/32" 14' 9-3/16" 30' 4-1/8" 5' 6-15/16" 16' 8-3/4" 31' 3-7/8" 6' 6-11/16" 16' 8-3/4" 32' 3-23/32" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. (d) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE AT THE DISHER, CONTACT SALES ENGINEERING. VENTILATION NOTES: (e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE 40 3/8" WITH & W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" FLOOR LINE 44 13/16" SEE NOTE (a) MODEL: STEAM R-L OPERATION 00-949502 REV A2 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP PLUMBING CONNECTIONS: COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF P3 COMMON STEAM CONNECTION (TANK HEAT & STEAM BOOSTER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE) see note (d). P4 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF P5 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF P6 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF P7 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF F40350 FT1000 Base Flight-Type Dishwasher Page 11 of 12

FLIGHT-TYPE DISHER FT (flight type) Models many additional variations of these model specifications are available. Engineering data furnished on request. Numbers in parentheses, after model number from left to right, represent length in feet of the following respectively; Loading section, Washing and Power Rinsing sections, Unloading section. FT1000 Base Series (5.5, 7.5, 9 Load / 8 Center / 5.5, 7.5, 9 Unload) Machine Ratings (Mechanical) Conveyor Speed Feet per minute 4.0-8.5 Dishes per Hour 14,316 Motor Horsepower Pre-Wash - 3 1 2; Wash - 5; Rinse - 5; Dual Rinse - 1 6; Final Rinse - 1 2; Conveyor - 1 3 Tank Capacity Gallons Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 7.2 Rate of Final Rinse Gallons per minute (Pumped rinse).97 Final Rinse Consumption Gallons per hour (Pumped rinse) 58 Exhaust Requirements Cubic Feet per minute 550 (at standard air conditions) Latent/Sensible Heat BTU per hour Electric - Latent: 76,000 / Sensible: 32,600 Steam - Latent: 90,700 / Sensible: 38,900 Electric Heat Requirements Tank Heat - Kilowatt (Regulated) Optional Electric Booster - Kilowatt Steam Heat Requirements Steam Consumption Tank Heat - Pounds per hour - maximum (Regulated) - based on 10 to 45 PSI steam at the machine Optional Steam Booster - Pounds per hour - maximum - based on 20 PSI steam, 110 F incoming water raised to 185 F (75 F rise) (180 F minimum) Disconnect switches are recommended for each power circuit connected to dishwasher. These disconnect switches are NOT furnished by Hobart and should be installed by the electrical contractor at the time of installation. Circuit breakers optional at extra cost. Total tank heat - 49KW (Wash, Rinse, Dual Rinse) 18KW - 110 F incoming water raised to 185 F (75 F rise) (180 F minimum) 209 lbs./150 F Wash minimum - 160 F Rinse minimum - 160 F Dual Rinse minimum 47 lbs./180 F Final Rinse minimum Peak Rate of Drain Flow Gallons per minute Initial rate with full tanks 38 Shipping Weight Crated Varies by individual model - consult your Hobart representative As continued product improvement is a policy of Hobart, specifications are subject to change without notice. Page 12 of 12 F40350 (REV. 09/14) F40350 FT1000 Base Flight-Type Dishwasher LITHO IN U.S.A. (H-01)