User s Manual Relay Output Extension Module OREL-01

Similar documents
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Modular I/O System Analog and Digital Interface Modules

Tina 2A/B Adaptor unit

48 SERIES Relay interface modules 10 A

Original instructions Tina 3A/Aps Adaptor unit

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

I STAR COMPUTER CO., LTD

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Safety Manual BT50(T) Safety relay / Expansion relay

INSTALLATION INSTRUCTIONS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MCR1900 Media Converter 19-Slot Chassis

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ST Series POWER SUPPLIES USER INSTRUCTIONS

Pluggable interface relays CR-P Pcb relays

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

38 Series - Relay interface modules A

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX SA/S Switch Actuators Product Manual

DLP-PU/E Instruction Manual

ABB general machinery drives. User s manual ACS355 drives

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MINI MCR-SL-R-UI(-SP)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

49 Series - Relay interface modules A. Features

Voltage Regulator SPAU 341 C. Product Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB Drives. Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01

HM-W536 Install Guide

80 Series - Modular timers 16 A. Features

Rack mounted telephone- and leased line modem for industrial applications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Low Voltage Products. Switches Automatic Transfer Switches

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

MasterINTERFACE 39 Series - Relay interface modules

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

How To Set Up An Inverter

Achat 115MA full-range speaker. user manual

UniStream CPU-for-Panel

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

BNI EIP Z009 IP67 Module, Unmanaged Switch

Telephone- and leased line modem for industrial applications TD-36

38 Series - Relay interface modules A

PSR The compact range Description

Model: DC-A2IO Advanced HVAC Controller

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MIC-WKT and MIC-WKT-IR

OZW30. Central Unit SYNERGYR

Waveguide Access Point WGA631. Product Guide

CompactLogix Power Supplies Specifications

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Digital input modules

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

SYSTEM DESCRIPTION Termination Boards

NX safety stand-alone

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

ADM1TE 5/30A DIN rail single phase two wire energy meter

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Advantium 2 Plus Alarm

12-Volt 10-Amp Regulated Power Supply

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Model 201 Wiegand Touchpad Reader Installation Guide

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SYSTEM 4C. C R H Electronics Design

Operating Manual UWAPS-TINY Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Disturbance Recoder SPCR 8C27. Product Guide

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Square D Clipsal C-Bus Network Analyzer

CO2 Alarm. Operation. Application

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

PCS0100en Persy Control Services B.V. Netherlands

Panel Meters and Controllers Modular Panel Meter Type EDM 35

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

LIEBERT VNSA Installation Sheet

R.C.C.B. s two-pole LEXIC

Product Information Sheet UH36 Hi Pot Tester

Transcription:

Drive IT Low Voltage AC Drives User s Manual Relay Output Extension Module OREL-01

2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians only. WARNING! The drive and adjoining equipment must be properly grounded. WARNING! Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the drive, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. WARNING! The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. WARNING! There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working on the unit. Neglecting these instructions can cause physical injury or death. Use of Warnings and Notes There are two types of safety instructions throughout this manual: Notes draw attention to a particular condition or fact, or give information on a subject. Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment. They also tell you how to avoid the danger. The warning symbols are used as follows: Dangerous voltage warning warns of high voltage which can cause physical injury and/or damage to the equipment. Safety

3 Table of Contents Safety............................................................ 2 Use of Warnings and Notes......................................... 2 Table of Contents.................................................. 3 Installation........................................................ 4 Preparing for Installation........................................... 4 Installing the Module.............................................. 5 Start-Up.......................................................... 7 Diagnostics....................................................... 8 Diagnostic LED.................................................. 8 Technical Data..................................................... 9 Table of Contents

4 Installation Preparing for Installation The OREL-01 Module The Relay Output Extension module (OREL) is an interface for connecting three relay outputs to an ACS550 or ACH550 drive. Module Layout Warning Sticker Green LED Relay 4 Relay 5 Relay 6 X0051 Compatibility The OREL-01 is compatible with all ACS550 and ACH550 drives. Installation

5 Installing the Module Delivery Check The option package contains: OREL-01 module Warning stickers in several languages This manual Mounting WARNING! Follow the safety instructions given in this guide and in the ACS550 or ACH550 User s Manual. To mount the OREL-01 module: 1. If not already off, remove mains power from the drive. 2. Remove the drive cover. (See instructions in the drive User s Manual.) 3. Insert the OREL-01 module s plastic hooks into the front of the drive at SLOT 1. 4. Carefully fit the connector at the other end of the module into the drive connector. 5. Press until the retaining clip 6 5 locks the module into position. 4 NOTE! Signal and power connections to the drive are automatically made through a 6-pin connector. 6. Non-English speaking 3 locations: Add a warning sticker in the appropriate language over the existing warning on the top of the module. X0052 Installation

6 Wiring Use 0.5 to 1.5 mm 2 (20 to 16 AWG) cable with an appropriate voltage rating for digital signals. 1. Refer to Terminal Designations on page 6 and connect control wires to the OREL-01 module. Terminal Designations Use the following table for reference when wiring terminals. Identification Hardware Description 1 RO4C RELAY OUTPUTS RO4 TO RO6: 2 RO4A Max. continuous current: 3 RO4B 2 A rms (cos ϕ = 1), 1 A rms (cos ϕ = 0.4) 4 RO5C Max. switching capability: 5 RO5A 6 A (24 V DC, resistive load) 6 RO5B 1500 VA (250 V AC) 7 RO6C Galvanically isolated from each other (2.5 kv AC, 1 min.) 8 RO6A 9 RO6B Replace Drive Cover 1. Refer to the drive s User s manual and replace the drive s cover. Apply Power 1. Turn on the mains power to the drive. Note! When power is applied to the drive, the LED on the OREL module should light. 2. Continue with the next section, Start-Up. Installation

7 Start-Up To configure the operation of the relays added using the OREL-01 module: 1. Power up the drive. 2. Use the control panel on the drive and set the parameters for relay outputs 4 to 6 in Group 14 Relay Outputs. Refer to the drive s User s Manual for parameter descriptions, and for instruction on the control panel operation. Start-Up

8 Diagnostics Diagnostic LED There is one diagnostic LED on the OREL-01 module. If the OREL-01 is properly installed, the green LED lights when the drive is powered up. If the LED does not light within 5 seconds after power-up, there is no communication with the drive. Step down this column. If an item is TRUE, look to the RIGHT for suggestions. The module connection may be damaged The module may have failed. Corrective Action Warning! Dangerous voltages are present on the connector. Power down before attempting to repair connector pins. Power down. Remove the module and check the condition of the pins in the 6-pin connector. Reconnect and retest. Replace the module. Diagnostics

9 Technical Data Dimensions Module dimensions are: Ref. mm in H 9.2 0.4 L 46.4 1.8 W 36.2 1.4 Enclosure Degree of Protection The module is mounted inside the drive enclosure. Refer to the drive s rating. Ambient Conditions The module is mounted inside the drive enclosure. Refer to the drive s requirements. Connectors X0053 Connectors on the module: 6-pin connector. Three, 3-pin, screw-type, non-detachable terminal blocks that accept wire connectors up to 1.5 mm 2 (16 AWG). Technical Data

10 Specifications Module Specifications Estimated min. lifetime: > 200,000 cycles/relay, at maximum continuous current operation. All materials are UL/CSA-approved. Module complies with EMC standards EN 50081-2 and EN 50082-2. Relay Outputs The specifications for the module relay outputs are: Max. contact voltage: 30 V DC, 250 V AC Max. switching capability: 6 A (24 V DC, resistive load) 1500 VA (250 V AC) Max. continuous current: 2 A rms (cos ϕ = 1), 1 A rms (cos ϕ = 0.4) Minimum current: 10 ma, 12 V DC Contact material: Silver-nickel (AgN) Isolation between relay digital outputs, test voltage: 2.5 kv rms, 1 minute Technical Data

3AUA0000001935 REV A / EN EFFECTIVE: April 15, 2003 ABB Oy AC Drives P.O. Box 184 FIN-00381 HELSINKI FINLAND Telephone +358 10 22 11 Telefax +358 10 22 22681 Internet http://www.abb.com ABB Inc. Drives and Power Electronics 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262 785-3200 800 243-4384 Telefax 262 780-5135