1/8. Field settings table. Applicable indoor units *HVZ04S18CB3V *HVZ08S18CB3V *HVZ16S18CB3V. Notes (*5) *04/08* (*6) *16* 4P

Similar documents
Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

ROTEX Gas-Hybrid-Heat Pump

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Natural geothermal energy.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

A Class Air Source Heat Pump User Guide

SIEMENS RVA

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Aerona Air Source Heat Pumps

Homeowner Quick Start Guide. Version 2

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

EcoDesign & Labelling Directive (ErP)

The natural ombination

CGC s Hybrid System Loop Control

Time to Rethink Heating

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

Hybrid heat pumps. saving energy and reducing carbon emissions

The Benefits Really Add Up

ALFEA HYBRID DUO GAZ. New Model 2011

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Hot Water. Heat pump water heaters. Residential and Commercial R410a


INSTALLER CATALOGUE DAIKIN ALTHERMA LOW TEMPERATURE HEAT PUMP

omfort all-in-one applications for residential & commercial DAIKIN ALTHERMA HEATING CATALOGUE

Electric Flow Boiler

OPERATION MANUAL. Indoor unit and options for air to water heat pump system

SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Operating instructions

Hybrid. Daikin Altherma. heat pump systems A POWERFUL TOOL TO CONTRIBUTE TO THE 20/20/20-TARGETS

The natural ombination

Daikin Altherma Hybrid Heat Pump

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Daikin Altherma Hybrid Heat Pump

ROTEX gas hybrid heat pump. A strong team.

Daikin Altherma hybrid heat pump. The natural combination

Fixture List 2018 FIFA World Cup Preliminary Competition

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE

Drayton Digistat +2RF

Features of your Air to water heat pump

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

ELECTRIC CENTRAL HEATING FLOW BOILER

Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m

The natural ombination

23/11/2015 TASK 4 REPORT - TECHNICAL ANALYSIS. Use of Task 4 analyses. Introduction and approach - Task 4 objective

HVAC Processes. Lecture 7

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Cruise Line Agencies of Alaska. Cruise Ship Calendar for 2016 FOR PORT(S) = KTN AND SHIP(S) = ALL AND VOYAGES = ALL

Contents. Introduction

Daikin Altherma Hybrid Heat Pump

Installation & User Instructions

Technical Support Bulletin Nr. 20 Special AC Functions

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Cruise Line Agencies of Alaska. Cruise Ship Calendar for 2016 FOR PORT(S) = KTN AND SHIP(S) = ALL AND VOYAGES = ALL

Air Source Heat Pump Installation and Maintenance Manual

Failure code manual. content

HEAT INTERFACE UNITS (Modular)

Single Zone LCD Thermostat Operating Instructions

Combination Ductless Heat Pump & Heat Pump Water Heater Lab and Field Tests

Glossary of Heating, Ventilation and Air Conditioning Terms

Congratulations! Your unique solar monitor ID is located on your monitoring unit as seen on this page.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Tackling the renovation challenge: high temperature hybrid heat pumps. François Bruggemans, DAIKIN Europe NV

Digital timer thermosatat. isense. Installation and Service Manual AG

Porcia, 20 novembre 2012

PC PROGRAM INSTRUCTIONS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

omfort all-in-one applications for residential & commercial DAIKIN ALTHERMA HEATING CATALOGUE

Metering and Monitoring Service Packages Technical Supplement

WATER SOURCE / GEOTHERMAL COOLING HEAT PUMP

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50AAV1 EKHVMRD80AAV1 EKHVMYD50AAV1 EKHVMYD80AAV1

Mixing Valves. ARGUS Application Note: Mixing Valves

CRK24-B1 Heated/chilled ceiling system

Workshop 7 PC Software - Tracker

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

Multifamily Central Heat Pump Water Heating

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

Vitocaldens 222-F Compact Gas-Hybrid appliance

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Gas Condensing Boilers

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Engineering Specifications

How to choose a heat pump and use it wisely

The new Ecodesign regulation for heaters: what does it mean for heat pumps?

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT

Air Source Heat Pump Installation and Maintenance Manual Combi Hybrid

Versati Air to Water Heat Pump

Transcription:

1/8 Applicable indoor units *HVZ4S18CB3V *HVZ8S18CB3V *HVZ16S18CB3V Notes (*5) *4/8* (*6) *16* 4P41673-1 - 215.4

2/8

3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4 21 C 7.4.1.2 Eco (heating) R/W [3-7]~[3-6], step: A.3.2.4 19 C LWT main 7.4.2.1 [8-9] Comfort (heating) R/W [9-1]~[9-], step: 1 C 7.4.2.2 [8-A] Eco (heating) R/W [9-1]~[9-], step: 1 C 33 C 7.4.2.5 Comfort (heating) R/W -1~1 C, step: 1 C C 7.4.2.6 Eco (heating) R/W -1~1 C, step: 1 C -2 C Tank temperature 7.4.3.1 [6-A] Storage comfort R/W 3~[6-E] C, step: 1 C 6 C 7.4.3.2 [6-B] Storage eco R/W 3~min(5, [6-E]) C, step: 1 C 7.4.3.3 [6-C] Reheat R/W 3~min(5, [6-E]) C, step: 1 C Quiet level 7.4.4 R/W : Level 1 1: Level 2 2: Level 3 Electricity price 7.4.5.1 [C-C] High R/W,~99/kWh [D-C] /kwh 7.4.5.2 [C-D] Medium R/W,~99/kWh [D-D] /kwh 7.4.5.3 [C-E] [D-E] Low R/W,~99/kWh /kwh Fuel price 7.4.6 R/W,~99/kWh,~29/MBtu 8,/kWh Set weather dependent Main Set weather-dependent heating 7.7.1.1 [1-] Set weather-dependent heating Low ambient temp. for LWT main zone heating WD curve. R/W -4~5 C, step: 1 C -1 C 7.7.1.1 [1-1] Set weather-dependent heating High ambient temp. for LWT main zone heating WD curve. ~, step: 1 C 7.7.1.1 [1-2] Set weather-dependent heating Leaving water value for low ambient temp. for LWT main zone heating WD curve. R/W [9-1]~[9-] C, step: 1 C 7.7.1.1 [1-3] Set weather-dependent heating Leaving water value for high ambient temp. for LWT main zone heating WD curve. R/W [9-1]~min(45, [9-]) C, step: 1 C Additional Set weather-dependent heating 7.7.2.1 [-] Set weather-dependent heating Leaving water value for high ambient temp. for LWT add zone heating WD curve. R/W [9-5]~min(45,[9-6]) C, step: 1 C 7.7.2.1 [-1] Set weather-dependent heating Leaving water value for low ambient temp. for LWT add zone heating WD curve. R/W [9-5]~[9-6] C, step: 1 C 7.7.2.1 [-2] Set weather-dependent heating High ambient temp. for LWT add zone heating WD curve. ~, step: 1 C 7.7.2.1 [-3] Set weather-dependent heating Low ambient temp. for LWT add zone heating WD curve. R/W -4~5 C, step: 1 C -1 C Installer settings System layout Standard A.2.1.1 [E-] Unit type R/O ~5 : LT split A.2.1.2 [E-1] Compressor type R/O : 8 (*5) 1: 16 (*6) A.2.1.3 [E-2] Indoor software type R/O 1: Type 2 A.2.1.4 [E-3] Backup heater steps R/O 1: 1 step A.2.1.5 [5-D] BUH type R/O 1: 1P,(1/1+2) A.2.1.6 [D-1] Preferential kwh rate R/W : No 1: Active open 2: Active closed A.2.1.7 [C-7] Unit control method R/W : LWT control 1: Ext RT control 2: RT control A.2.1.8 [7-2] Number of LWT zones R/W : 1 LWT zone 1: 2 LWT zones A.2.1.9 [F-D] Pump operation mode R/W : Continuous 1: Sample 2: Request A.2.1.A [E-4] Power saving possible R/O : No (*6) (*5) A.2.1.B User interface location R/W : At unit 1: In room Options A.2.2.1 [E-5] DHW operation R/W : No A.2.2.3 [E-7] DHW tank type R/O ~6 1: Type 2 A.2.2.4 [C-5] Contact type main : Thermo ON/OFF 2: C/H request A.2.2.5 [C-6] Contact type add. : Thermo ON/OFF 2: C/H request A.2.2.6.1 [C-2] Digital I/O PCB Ext. backup heat src R/W ~3 : No 1: Bivalent A.2.2.6.2 [D-7] Digital I/O PCB Solar kit R/O ~1 : No A.2.2.6.3 [C-9] Digital I/O PCB Alarm output R/W : Normally open 1: Normally closed A.2.2.6.4 [F-4] Digital I/O PCB Bottom plate heater R/W : No A.2.2.7 [D-4] Demand PCB R/W : No 1: Pwr consmp ctrl (*5) *4/8* (*6) *16* 4P41673-1 - 215.4

4/8 A.2.2.8 [D-8] External kwh meter 1 R/W : No 1:,1 pulse/kwh 2: 1 pulse/kwh 3: 1 pulse/kwh 4: 1 pulse/kwh 5: 1 pulse/kwh A.2.2.9 [D-9] External kwh meter 2 R/W : No 1:,1 pulse/kwh 2: 1 pulse/kwh 3: 1 pulse/kwh 4: 1 pulse/kwh 5: 1 pulse/kwh A.2.2.A [D-2] DHW pump R/W : No 1: Secondary rtrn 2: Disinf. shunt A.2.2.B [C-8] External sensor R/W : No 1: Outdoor sensor 2: Room sensor Capacities A.2.3.2 [6-3] BUH: step 1 R/W ~1 kw, step:,2 kw 3 kw A.2.3.6 [6-7] Bottom plate heater R/W ~2 W, step: 1 W W Space operation LWT settings Main A.3.1.1.1 LWT setpoint mode R/W : Fixed 1: Weather dep. 2: Fixed + scheduled 3: WD + scheduled A.3.1.1.2.1 [9-1] Temperature range Minimum temp (heating) 5~37 C, step: 1 C A.3.1.1.2.2 [9-] Temperature range Maximum temp (heating) R/W 37~55, step: 1 C A.3.1.1.5 [8-5] Modulated LWT R/W : No A.3.1.1.6.1 [F-B] Shut-off valve Thermo On/OFF R/W : No A.3.1.1.7 [9-B] Emitter type R/W : Quick 1: Slow Additional A.3.1.2.1 LWT setpoint mode R/W : Fixed 1: Weather dep. 2: Fixed + scheduled 3: WD + scheduled A.3.1.2.2.1 [9-5] Temperature range Minimum temp (heating) 5~37 C, step: 1 C A.3.1.2.2.2 [9-6] Temperature range Maximum temp (heating) R/W 37~55, step: 1 C Delta T source A.3.1.3.1 [9-9] Heating R/W 3~1 C, step: 1 C 5 C Room thermostat A.3.2.1.1 [3-7] Room temp. range Minimum temp (heating) 2~18 C, step: A.3.2.4 12 C A.3.2.1.2 [3-6] Room temp. range Maximum temp (heating) 8~3 C, step: A.3.2.4 3 C A.3.2.2 [2-A] Room temp. offset R/W -5~5 C, step:,5 C C A.3.2.3 [2-9] Ext. room sensor offset R/W -5~5 C, step:,5 C C A.3.2.4 Room temp. step R/W :,5 C 1: 1 C Operation range A.3.3.1 [4-2] Space heating OFF temp 4~, step: 1 C (*5) 14~, step: 1 C (*6) Domestic hot water (DHW) Type A.4.1 [6-D] R/W : Reheat only 1: Reheat + sched. 2: Scheduled only Disinfection A.4.4.1 [2-1] Disinfection R/W : No A.4.4.2 [2-] Operation day R/W : Each day 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Sunday A.4.4.3 [2-2] Start time R/W ~23 hour, step: 1 hour 23 A.4.4.4 [2-3] Temperature target R/W 6 C A.4.4.5 [2-4] Duration R/W 4~6 min, step: 5 min 4 min Maximum setpoint A.4.5 [6-E] R/W 4~6 C, step: 1 C 6 C SP mode A.4.6 R/W : Fixed 1: Weather dep. Weather dependent curve A.4.7 [-B] Weather-dependent curve Leaving water value for high ambient temp. for R/W 35~[6-E] C, step: 1 C DHW WD curve. A.4.7 [-C] Weather-dependent curve Leaving water value for low ambient temp. for R/W 45~[6-E] C, step: 1 C DHW WD curve. 6 C A.4.7 [-D] Weather-dependent curve High ambient temp. for DHW WD curve. ~, step: 1 C A.4.7 [-E] Weather-dependent curve Low ambient temp. for DHW WD curve. R/W -4~5 C, step: 1 C -1 C Heat sources 4P41673-1 - 215.4 (*5) *4/8* (*6) *16*

5/8 Backup heater A.5.1.1 [4-] Operation mode R/W : Disabled 2: Only DHW A.5.1.2 Emergency R/W : Manual 1: Automatic A.5.1.4 [5-1] Equilibrium temp. R/W -15~, step: 1 C C System operation Auto restart A.6.1 [3-] R/W : No Preferential kwh rate A.6.2.1 [D-] Allowed heaters R/W ~3 : None 2: BUH only A.6.2.2 [D-5] Forced pump OFF R/W : Forced off 1: As normal Pwr consumpt. Control A.6.3.1 [4-8] Mode R/W : No limitation 1: Continuous 2: Digital inputs A.6.3.2 [4-9] Type R/W : Current 1: Power A.6.3.3 [5-5] Amp. value R/W ~5 A, step: 1 A 5 A A.6.3.4 [5-9] kw value R/W ~2 kw, step:,5 kw 2 kw A.6.3.5.1 [5-5] Amp. limits for DI Limit DI1 R/W ~5 A, step: 1 A 5 A A.6.3.5.2 [5-6] Amp. limits for DI Limit DI2 R/W ~5 A, step: 1 A 5 A A.6.3.5.3 [5-7] Amp. limits for DI Limit DI3 R/W ~5 A, step: 1 A 5 A A.6.3.5.4 [5-8] Amp. limits for DI Limit DI4 R/W ~5 A, step: 1 A 5 A A.6.3.6.1 [5-9] kw limits for DI Limit DI1 R/W ~2 kw, step:,5 kw 2 kw A.6.3.6.2 [5-A] kw limits for DI Limit DI2 R/W ~2 kw, step:,5 kw 2 kw A.6.3.6.3 [5-B] kw limits for DI Limit DI3 R/W ~2 kw, step:,5 kw 2 kw A.6.3.6.4 [5-C] kw limits for DI Limit DI4 R/W ~2 kw, step:,5 kw 2 kw A.6.3.7 [4-1] Priority R/W ~2 : None 2: BUH Averaging time A.6.4 [1-A] R/W : No averaging 1: 12 hours 2: 24 hours 3: 48 hours 4: 72 hours Ext amb. sensor offset A.6.5 [2-B] R/W -5~5 C, step:,5 C C Boiler efficiency A.6.A [7-5] R/W : Very high 1: High 2: Medium 3: Low 4: Very low Overview settings A.8 [-] Leaving water value for high ambient temp. for LWT add zone heating WD curve. R/W [9-5]~min(45,[9-6]) C, step: 1 C A.8 [-1] Leaving water value for low ambient temp. for LWT add zone heating WD curve. R/W [9-5]~[9-6] C, step: 1 C A.8 [-2] High ambient temp. for LWT add zone heating WD curve. ~, step: 1 C A.8 [-3] Low ambient temp. for LWT add zone heating WD curve. R/W -4~5 C, step: 1 C -1 C A.8 [-4] -- R/W 8 A.8 [-5] -- 2 A.8 [-6] -- R/W 35 A.8 [-7] -- R/W 2 A.8 [-B] Leaving water value for high ambient temp. for DHW WD curve. R/W 35~[6-E] C, step: 1 C A.8 [-C] Leaving water value for low ambient temp. for DHW WD curve. R/W 45~[6-E] C, step: 1 C 6 C A.8 [-D] High ambient temp. for DHW WD curve. ~, step: 1 C A.8 [-E] Low ambient temp. for DHW WD curve. R/W -4~5 C, step: 1 C -1 C A.8 [1-] Low ambient temp. for LWT main zone heating WD curve. R/W -4~5 C, step: 1 C -1 C A.8 [1-1] High ambient temp. for LWT main zone heating WD curve. ~, step: 1 C A.8 [1-2] Leaving water value for low ambient temp. for LWT main zone heating WD curve. R/W [9-1]~[9-], step: 1 C A.8 [1-3] Leaving water value for high ambient temp. for LWT main zone heating WD curve. R/W [9-1]~min(45, [9-]) C, step: 1 C A.8 [1-4] -- A.8 [1-5] -- A.8 [1-6] -- R/W 2 A.8 [1-7] -- R/W 35 A.8 [1-8] -- R/W 22 A.8 [1-9] -- 8 A.8 [1-A] What is the averaging time for the outdoor temp? R/W : No averaging 1: 12 hours 2: 24 hours 3: 48 hours 4: 72 hours (*5) *4/8* (*6) *16* 4P41673-1 - 215.4

6/8 A.8 [2-] When should the disinfection function be executed? R/W : Each day 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 7: Sunday A.8 [2-1] Should the disinfection function be executed? R/W : No A.8 [2-2] When should the disinfection function start? R/W ~23 hour, step: 1 hour 23 A.8 [2-3] What is the disinfection target temperature? R/W 6 C A.8 [2-4] How long must the tank temperature be maintained? R/W 4~6 min, step: 5 min 4 min A.8 [2-5] Room antifrost temperature R/W 4~16 C, step: 1 C 12 C A.8 [2-6] Room frost protection R/W : Disabled A.8 [2-9] Adjust the offset on the measured room temperature R/W -5~5 C, step:,5 C C A.8 [2-A] Adjust the offset on the measured room temperature R/W -5~5 C, step:,5 C C A.8 [2-B] What is the required offset on the measured outdoor temp.? R/W -5~5 C, step:,5 C C A.8 [3-] Is auto restart of the unit allowed? R/W : No A.8 [3-1] -- A.8 [3-2] -- 1 A.8 [3-3] -- 4 A.8 [3-4] -- 2 A.8 [3-5] -- 1 A.8 [3-6] What is the maximum desired room temperature in heating? 8~3 C, step: A.3.2.4 3 C A.8 [3-7] What is the mimimum desired room temperature in heating? 2~18 C, step: A.3.2.4 12 C A.8 [3-8] -- R/W A.8 [3-9] -- R/W A.8 [4-] What is the BUH operation mode? R/W : Disabled 2: Only DHW A.8 [4-1] Which electric heater has priority? R/W ~2 : None 2: BUH A.8 [4-2] Below which outdoor temperature is heating allowed? 4~, step: 1 C (*5) 14~, step: 1 C (*6) A.8 [4-3] -- R/W 3 A.8 [4-4] -- 2 A.8 [4-5] -- A.8 [4-6] -- (Do not change this value) /1 A.8 [4-7] -- A.8 [4-8] Which power limitation mode is required on the system? R/W : No limitation 1: Continuous 2: Digital inputs A.8 [4-9] Which power limitation type is required? R/W : Current 1: Power A.8 [4-A] -- A.8 [4-B] -- A.8 [4-D] -- R/W 3 A.8 [4-E] Is the installer on site? R/W : No A.8 [5-] Is backup heater operation allowed above equilibrium temperature during space R/W : Allowed heating operation? 1: Not allowed A.8 [5-1] What is the equilibrium temperature for the building? R/W -15~, step: 1 C C A.8 [5-2] Space heating priority. R/W : Disabled A.8 [5-3] Space heating priority temperature. R/W -15~, step: 1 C C A.8 [5-4] Set point correction for domestic hot water temperature. R/W ~2 C, step: 1 C 1 C A.8 [5-5] What is the requested limit for DI1? R/W ~5 A, step: 1 A 5 A A.8 [5-6] What is the requested limit for DI2? R/W ~5 A, step: 1 A 5 A A.8 [5-7] What is the requested limit for DI3? R/W ~5 A, step: 1 A 5 A A.8 [5-8] What is the requested limit for DI4? R/W ~5 A, step: 1 A 5 A A.8 [5-9] What is the requested limit for DI1? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-A] What is the requested limit for DI2? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-B] What is the requested limit for DI3? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-C] What is the requested limit for DI4? R/W ~2 kw, step:,5 kw 2 kw A.8 [5-D] What type of backup heater installation is used? R/O ~5 1: 1P,(1/1+2) A.8 [5-E] -- 1 A.8 [6-] The temperature difference determining the heat pump ON temperature. R/W 2~2 C, step: 1 C 2 C A.8 [6-1] The temperature difference determining the heat pump OFF temperature. R/W ~1 C, step: 1 C 2 C A.8 [6-2] -- R/W A.8 [6-3] What is the capacity of the backup heater step 1? R/W ~1 kw, step:,2 kw 3 kw A.8 [6-4] -- R/W A.8 [6-5] -- A.8 [6-6] -- A.8 [6-7] What is the capacity of the bottom plate heater? R/W ~2 W, step: 1 W W 4P41673-1 - 215.4 (*5) *4/8* (*6) *16*

7/8 A.8 [6-8] What is the hysteresis to be used in reheat mode? R/W 2~2 C, step: 1 C 1 C A.8 [6-9] -- A.8 [6-A] What is the desired comfort storage temperature? R/W 3~[6-E] C, step: 1 C 6 C A.8 [6-B] What is the desired eco storage temperature? R/W 3~min(5, [6-E]) C, step: 1 C A.8 [6-C] What is the desired reheat temperature? R/W 3~min(5, [6-E]) C, step: 1 C A.8 [6-D] What is the desired DHW production type? R/W : Reheat only 1: Reheat + sched. 2: Scheduled only A.8 [6-E] What is the maximum temperature setpoint? R/W 4~6 C, step: 1 C 6 C A.8 [7-] -- R/W A.8 [7-1] -- R/W 2 A.8 [7-2] How many leaving water temperature zones are there? R/W : 1 LWT zone 1: 2 LWT zones A.8 [7-3] -- 2,5 A.8 [7-4] -- A.8 [7-5] Boiler efficiency R/W : Very high 1: High 2: Medium 3: Low 4: Very low A.8 [8-] -- 1 min A.8 [8-1] Maximum running time for domestic hot water operation. R/W 5~95 min, step: 5 min 3 min A.8 [8-2] Anti-recycling time. R/W ~1 hour, step:,5 hour,5 hour A.8 [8-3] -- R/W 5 A.8 [8-4] Additional running time for the maximum running time. R/W ~95 min, step: 5 min 95 min A.8 [8-5] Allow modulation of the LWT to control the room temp? R/W : No A.8 [8-6] Leaving water temperature maximum modulation. R/W ~1 C, step: 1 C 3 C A.8 [8-7] -- 8 A.8 [8-8] -- R/W 2 A.8 [8-9] What is the desired comfort main LWT in heating? R/W [9-1]~[9-], step: 1 C A.8 [8-A] What is the desired eco main LWT in heating? R/W [9-1]~[9-], step: 1 C 33 C A.8 [8-B] -- 13 A.8 [8-C] -- 1 A.8 [8-D] -- 16 A.8 [9-] What is the maximum desired LWT for main zone in heating? R/W 37~55, step: 1 C A.8 [9-1] What is the mimimum desired LWT for main zone in heating? 5~37 C, step: 1 C A.8 [9-2] -- R/W 22 A.8 [9-3] -- R/W 5 A.8 [9-4] Leaving water temperature overshoot temperature. ~4 C, step: 1 C 1 C A.8 [9-5] What is the mimimum desired LWT for add. zone in heating? 5~37 C, step: 1 C A.8 [9-6] What is the maximum desired LWT for add. zone in heating? R/W 37~55, step: 1 C A.8 [9-7] -- R/W 5 A.8 [9-8] -- R/W 22 A.8 [9-9] What is the desired delta T in heating? R/W 3~1 C, step: 1 C 5 C A.8 [9-A] -- R/W 5 A.8 [9-B] What emitter type is connected to the main LWT zone? R/W : Quick 1: Slow A.8 [9-C] Room temperature hysteresis. ~6 C, step:,5 C 1 C A.8 [9-D] Pump speed limitation R/W ~8, step:1 : 1% 1~4 : 8~5% 5~8 : 8~5% 6 A.8 [9-E] -- 6 A.8 [A-] -- A.8 [A-1] -- (*5) 3 (*6) A.8 [A-2] -- (*5) 1 (*6) A.8 [A-3] -- A.8 [A-4] -- A.8 [B-] -- A.8 [B-1] -- A.8 [B-2] -- A.8 [B-3] -- A.8 [B-4] -- A.8 [C-] Domestic heating water priority. R/O ~1 1: Heat pump priority A.8 [C-1] -- A.8 [C-2] Is an external backup heat source connected? R/W ~3 : No 1: Bivalent A.8 [C-3] Bivalent activation temperature. R/W -25~, step: 1 C C A.8 [C-4] Bivalent hysteresis temperature. R/W 2~1 C, step: 1 C 3 C A.8 [C-5] What is the thermo request contact type for the main zone? : Thermo ON/OFF 2: C/H request A.8 [C-6] What is the thermo request contact type for the add. zone? R/W : - 1: Thermo ON/OFF 2: C/H request A.8 [C-7] What is the unit control method in space operation? R/W : LWT control 1: Ext RT control 2: RT control (*5) *4/8* (*6) *16* 4P41673-1 - 215.4

8/8 A.8 [C-8] Which type of external sensor is installed? R/W : No 1: Outdoor sensor 2: Room sensor A.8 [C-9] What is the required alarm output contact type? R/W : Normally open 1: Normally closed A.8 [C-A] -- A.8 [C-C] High electricity price decimal (Do not use) R/W ~7 A.8 [C-D] Medium electricity price decimal (Do not use) R/W ~7 A.8 [C-E] Low electricity price decimal (Do not use) R/W ~7 A.8 [D-] Which heaters are permitted if prefer. kwh rate PS is cut? R/W ~3 : None 2: BUH only A.8 [D-1] Contact type of preferential kwh rate PS installation? R/W : No 1: Active open 2: Active closed A.8 [D-2] Which type of DHW pump is installed? R/W : No 1: Secondary rtrn 2: Disinf. shunt A.8 [D-3] Leaving water temperature compensation around C. R/W : Disabled, shift 2 C (from -2 to 2 C) 2: Enabled, shift 4 C (from -2 to 2 C) 3: Enabled, shift 2 C (from -4 to 4 C) 4: Enabled, shift 4 C (from -4 to 4 C) A.8 [D-4] Is a demand PCB connected? R/W : No 1: Pwr consmp ctrl A.8 [D-5] Is the pump allowed to run if prefer. kwh rate PS is cut? R/W : Forced off 1: As normal A.8 [D-7] -- R/O A.8 [D-8] Is an external kwh meter used for power measurement? R/W : No 1:,1 pulse/kwh 2: 1 pulse/kwh 3: 1 pulse/kwh 4: 1 pulse/kwh 5: 1 pulse/kwh A.8 [D-9] Is an external kwh meter used for power measurement? R/W : No 1:,1 pulse/kwh 2: 1 pulse/kwh 3: 1 pulse/kwh 4: 1 pulse/kwh 5: 1 pulse/kwh A.8 [D-A] -- A.8 [D-B] -- 2 A.8 [D-C] What is the high electricity price (Do not use) R/W ~49 A.8 [D-D] What is the medium electricity price (Do not use) R/W ~49 A.8 [D-E] What is the low electricity price (Do not use) R/W ~49 A.8 [E-] Which type of unit is installed? R/O ~5 : LT split A.8 [E-1] Which type of compressor is installed? R/O : 8 (*5) 1: 16 (*6) A.8 [E-2] What is the indoor unit software type? R/O ~1 1: Type 2 A.8 [E-3] What is the number of backup heater steps? R/O ~2 1: 1 step A.8 [E-4] Is the power saving function available on the outdoor unit? R/O : No (*6) (*5) A.8 [E-5] Can the system prepare domestic hot water? R/W : No A.8 [E-6] Is a DHW tank installed in the system? R/O : No A.8 [E-7] What kind of DHW tank is installed? R/O ~6 1: Type 2 A.8 [E-8] Power saving function for outdoor unit. R/W : Disabled (*6) (*5) A.8 [E-9] -- A.8 [E-A] -- A.8 [E-B] Is a bi-zone kit installed? R/O ~1 A.8 [E-C] -- A.8 [E-D] -- A.8 [F-] Pump operation allowed outside range. R/W : Disabled A.8 [F-1] -- R/W 2 A.8 [F-2] Bottom plate heater ON temperature. R/W 3~1 C, step: 1 C 3 C A.8 [F-3] Bottom plate heater hysteresis. R/W 2~5 C, step: 1 C 5 C A.8 [F-4] Is a bottom plate heater connected? R/W : No A.8 [F-5] -- A.8 [F-6] -- A.8 [F-9] Pump operation during flow abnormality. R/W : Disabled A.8 [F-A] -- A.8 [F-B] Close shut-off valve during thermo OFF? R/W : No A.8 [F-C] -- A.8 [F-D] What is the pump operation mode? R/W : Continuous 1: Sample 2: Request 4P41673-1 - 215.4 (*5) *4/8* (*6) *16*