Building Technologies Division Infrastructure & Cities Sector

Similar documents
TX OPEN RS232/485 module

Digital input modules

Modular I/O System Analog and Digital Interface Modules

PCS0100en Persy Control Services B.V. Netherlands

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Product and functional description

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SYSTEM DESCRIPTION Termination Boards

TMS TANK MANAGEMENT SYSTEM

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

WEB log. Device connection plans

NC-12 Modbus Application

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

PXM20-E. Operator unit DESIGO PX

ADM1TE 5/30A DIN rail single phase two wire energy meter

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

CoolWave r 2 Phase Control Board and Cable Replacement Kits

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MCR1900 Media Converter 19-Slot Chassis

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

DALI RC BASIC SO. Control unit Operating instructions

TX2123 RS485 TO ETHERNET ADAPTOR

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

WD-AMX Water Detection Controllers

connecdim Gateway G1 Ethernet TCP/IP to DALI

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

User Manual Revision English

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

is then retained absolutely without interruption.

WEB log. Device connection plans

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

ABB Drives. User s Manual HTL Encoder Interface FEN-31

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Operating Instructions

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Online UPS. PowerWalker VFI 1000R/1U

COLOR VIDEO DOOR PHONE CDV-71BE/D

=============================== WARNING

Instruction Manual for Operating Panel 301 and 302

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Model 201 Wiegand Touchpad Reader Installation Guide

AIS750 Series Alarm Annunciator

Universal Serial Bus (USB) to DH-485 Interface Converter

Telephone- and leased line modem for industrial applications TD-36

GV- RK1352 Card Reader

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

VOICE RECORDING SYSTEM ISDN PRI / BRI

Heating Controller. Building Technologies HVAC Products

User Manual Revision English

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

User Guide. Model Insulation Tester / Megohmmeter

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Combi B Alarm box. Mounting instructions

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

YSmart Technology Co.,Ltd

SYSTEM 4C. C R H Electronics Design

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

AXIS T81B22 DC 30W Midspan

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Color Mark Sensor with Red or Green LED E3S-VS

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

User Manual Revision English

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

IO-RM3 3-Stage Relay Module

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

POINTS POSITION INDICATOR PPI4

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

User Manual Revision English

AC-115 Compact Networked Single Door Controller. Installation and User Manual

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RADIANT PLASMA 4700 Plasma Spark Generator

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

HP4000EX Hardware Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Adjustment functions for both span and shift have been incorporated

SYSTEM 45. C R H Electronics Design

IMR 6000/10../20../30

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

StructureScan HD Module. Installation Guide ENGLISH

Square D Clipsal C-Bus Network Analyzer

19 LED Tube Controller ORDERCODE 41003

Transcription:

7 615 Modbus Interface Interface between an LMV2... / LMV3 burner control and a modbus system, such as a building automation and control system (BACS). The modbus interface is based on the RS-485 standard. The and this Data Sheet are intended for use by OEMs which integrate the interface in their products! Use The is a microprocessor-based interface with galvanic separation used for connecting an LMV2 / LMV3 burner control to a modbus system. In such a system, the LMV2 / LMV3 operates as a modbus slave. The is designed for stationary use under the burner hood or in a control pane, always in connection with the LMV2 / LMV3 It offers: - Visualization of plant states - Control of plant - Logging 08.04.2014 Division Infrastructure & Cities Sector

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the unit. Siemens will not assume responsibility for damage resulting from unauthorized interference! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard Ensure protection against electric shock hazard by providing adequate protection for the connection terminals After each activity (mounting, installation and service work, etc.), check to ensure that wiring is in an orderly state and that the parameters have been correctly set Fall or shock can adversely affect the safety functions. Such units must not be put into operation even if they do not exhibit any damage The unit is approved for stationary use only The safety, warning and technical notes given in the Basic Documentation on the LMV27.100 system (P7541) also apply to this Data Sheet Mounting notes Ensure that the relevant national safety regulations are complied with The interface is designed for fitting to DIN mounting rails (as per EN 50 022) Degree of protection IP40 as per DIN EN 60 529 must be ensured by the burner or boiler manufacturer through adequate installation of the (e.g. installation under the burner hood or in the control panel) Ensure strain relief of the connected cables in compliance with the standards (e.g. DIN EN 60 730 and DIN EN 60 335) Ensure that spliced individual wires cannot touch neighboring terminals. Use adequate ferrules When making the wiring, protective extra low-voltage (safe separation from mains voltage) must be strictly segregated from extra low-voltage to ensure protection against electric shock hazard The connecting cables for the may only be removed or exchanged when the plant is shut down (all-polar disconnection), since the COM port of the LMV2 / LMV3 does not provide safe separation from mains voltage The connecting cable between the LMV2 / LMV3 and the must be suited for use under the burner hood or in control panels Cables must first be plugged into the socket for X10 or X20 and then into the interface Cable the plug for connection X20, before you put the plug into the (danger of contact break) Installation notes The housing of the is designed for fitting to an M36-DIN mounting rail (as per EN 50022, 35 mm corresponding to 2 modular units) Disposal notes The unit contains electrical and electronic components and must not be disposed of together with household waste. Local and currently valid legislation must be observed. 2/6

Technical data General unit data Operating voltage X20 Power consumption Safety class Degree of protection Fusing AC 24 V 10 % (PELV) DC 24 V 20 % (PELV) <2 W (typically) II IP30 (not when installed) Note: Degree of protection IP40 must be ensured by the burner or boiler manufacturer through adequate installation of Internal self-resetting fuse 125 ma (Poly switch) Cable lengths Cable requirements X10 (LMV2 / LMV3 ) Max. 3 m (100 pf/m) For use under the burner hood or in a control panel X20 (Modbus) Max. 100 m (100 pf/m) Cable insulation must be suited for the respective environmental conditions! Connector X10 (Molex / Combicon) 5 pins / RM 5.08 mm Connector X20 (Molex / Combicon) 5 pins / RM 5.08 mm Connecting cable Connecting cable to burner controls LMV2... / LMV3... Included in delivery Length Ca. 0.3 m Connection on X10 Connection on LMV2... / LMV3... X92 COM Environmental conditions Storage DIN EN 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...+60 C Humidity <95 % r.h. Transport DIN EN 60721-3-2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -20...+60 C Humidity <95 % r.h. Operation DIN EN 60721-3-3 Climatic conditions Class 3K3 Mechanical conditions Class 3M3 Temperature range -20...+60 C Humidity <95 % r.h. Attention! Condensation, formation of ice and ingress of water are not permitted! If this is not observed, there is a risk of loss of safety functions and a risk of electric shock. 3/6

Connection diagram LMV2... LMV3... Functional extra-low-voltage (FELV) Protective extra-low-voltage (PELV) Modbus system RS-485 Yellow Green Brown White Galvanic Seperation Example: Connection table for X20 (RS-485) to D-SUB 9 (RS-485) or Simatic Modbus / USS modules connection X20 General description D-SUB 9 plug (RS-485) Simatic ET200s 1SI Modbus / USS modules 6ES7138-4DF01-0AB0 6ES7138-4DF11-0AB0 X20 Pin 1 GND (Data) Pin 5 Pin 8 X20 Pin 2 Data- Pin 8 Pin 1 X20 Pin 3 Data+ Pin 3 Pin 2 X20 Pin 4 GND (power supply, PELV) X20 Pin 5 +Vs (AC 24 V ±10% DC 24 V ±20%) 4/6

Operating elements Switch Switch no. Alternative designation Function (switch position ON) 1 R1 ¹) RS-485, bus terminator 120 (between Data+ and Data-) OFF 2 R2 ¹) RS-485, 820 R-resistor against 5 V (Data+ against 5 V) OFF 3 R3 ¹) RS-485, 820 R-resistor against GND (Data- against GND) OFF 4 S1 Reserved OFF 5 S2 Reserved OFF 6 S3 Reserved OFF 7 S4 Reserved OFF 8 S5 Reserved OFF As supplied ¹) Terminators The terminators can be switched via switches no. 1 through 3 and are of importance only when the interface is installed at the end of the RS-485 line. The 120 resistor (switch no. 1) serves as a bus terminator. In principle, a terminator must be fitted at both ends of the line. Its resistance must correspond to the characteristic impedance of the line. The resistance of the corresponds to that of a typical RS-485 application. If not sufficient, an additional adequate resistor must be fitted. The characteristic impedance depends on the type of cable. In bus mode, terminators must not be connected to RS-485 modules located somewhere else on the line. The pull up and pull down resistors (switches no. 2 and 3) of 820 each generate a defined level, when all users on the line are switched to reception (high-impedance). Indication of operating states via LEDs LED color Red, flashing fast Orange, steady Green, steady Green, flashing Description Internal error Standby (X10.4, without voltage) Standby (LMV2 / LMV3, connected and ready to operate) Communication Modbus 5/6

Dimensions Dimensions in mm 49 8 29 86 7615m01/0806 45,5 60 35 5 43 6/6 2014 Siemens AG Infrastructure & Cities Sector Division Subject to change!