NI-TimeSync. Introduction, Installation, and Configuration USER GUIDE. Version 1.1. About the NI-TimeSync Driver Software

Similar documents
Coupling Microsoft Excel with NI Requirements Gateway

NI Real-Time Hypervisor for Windows

Getting Started with the LabVIEW Mobile Module

NI-XNET Hardware and Software

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

Coupling Microsoft Visio with NI Requirements Gateway

LabVIEW DSP Test Integration Toolkit for TI DSP

NI InsightCM Server Version 1.0

DAQ Getting Started Guide

NI PXI Installing Your PXI Board INSTALLATION GUIDE

System Overview and Terms

Measurement Studio. Contents RELEASE NOTES

LABVIEW DSP TEST TOOLKIT FOR TI DSP

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Set Up Your MXI -Express x1 System

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

Getting Started Manual

Getting Started with the LabVIEW Mobile Module Version 2009

Set Up Your MXI -Express x4 System

NI USB-5681 RF Power Meter Specifications

LabVIEW Report Generation Toolkit for Microsoft Office

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

NI 653x Cable Adapter

PCI Express Clock Specifications and Effect on NI PXIe-PCIe8375 Interoperability. White Paper

Unpack and Install the Devices, Accessories, and Cables

FIELDPOINT BUS EXTENDER CABLE

LabVIEW Report Generation Toolkit for Microsoft Office User Guide

Getting Started with the NI LabVIEW Embedded Module for ARM Microcontrollers

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Using MCC GPIB Products with LabVIEW

Using NI CompactDAQ Controllers

LabVIEW Internet Toolkit User Guide

Three Levels of Data-Logging Software from National Instruments

Getting Started with the LabVIEW Embedded Module for ARM Microcontrollers 1.0 For the Keil MCB2300

Distance-Learning Remote Laboratories using LabVIEW

Introduction to Data Acquisition

Developing Wireless GPIB Test Systems Using the GPIB-ENET/100

Best Practices for Deploying, Replicating, and Managing Real-Time and FPGA Applications. ni.com

StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

NI USB-6008/6009 OEM USER GUIDE

Lab View with crio Tutorial. Control System Design Feb. 14, 2006

NI-DAQ mx Base 3.x. Contents GETTING STARTED GUIDE

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

1. Driver Installation... 3

Installing the Gerber P2C Plotter USB Driver

IMAQ. IMAQ Vision for LabVIEW User Manual. IMAQ Vision for LabVIEW User Manual. June 2003 Edition Part Number B-01

GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS

PC - Program to Configure the Diagnostics Node of SmartRouter RTRSD and SmartRepeater RPTSD Software Description

About Measurement Studio

Data Collection Agent for Active Directory

Pipeliner CRM Phaenomena Guide Add-In for MS Outlook Pipelinersales Inc.

Qlik Sense Enabling the New Enterprise

Helm 4 Windows Event Viewer

This presentation introduces you to the new call home feature in IBM PureApplication System V2.0.

Embedded System Deployment and Management

Release Management for BMC Remedy IT Service Management version 7.0 WHITE PAPER

Connector for Microsoft Dynamics Configuration Guide for Microsoft Dynamics SL

Step by step installation of control card USER'S MANUAL (V1.0)

Polar Help Desk Installation Guide

How To Use Vision Builder Ai With An Inspection System

GUARD1 PLUS Mini-Attendant File Manager User's Guide Version 2.71

CompactRIO crio-9052

DeviceAnywhere Automation for Smartphones Setup Guide Windows Mobile

SharePoint AD Information Sync Installation Instruction

Sample. LabVIEW TM Core 1 Course Manual. Course Software Version 2010 August 2010 Edition Part Number B-01

Matisse Installation Guide for MS Windows. 10th Edition

LogLogic General Database Collector for Microsoft SQL Server Log Configuration Guide

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

InventoryControl for use with QuoteWerks Quick Start Guide

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

LabVIEWTM. Robotics Programming Guide for the FIRST Robotics Competition. LabVIEW Robotics Programming Guide for FRC. January D-01

CE 4.2 to Windows 7 - Synchronism Problem

TIGERPAW EXCHANGE INTEGRATOR SETUP GUIDE V3.6.0 August 26, 2015

Pipeliner CRM Phaenomena Guide Sales Pipeline Management Pipelinersales Inc.

Introduction to the NI Real-Time Hypervisor

Cognex Vision Software

Windows Server Update Services 3.0 SP2 Step By Step Guide

CA Nimsoft Monitor. Probe Guide for E2E Application Response Monitoring. e2e_appmon v2.2 series

A Step-by-Step Guide to Synchronous Volume Replication (Block Based) over a WAN with Open-E DSS

VisualDSP Emulation Tools Installation Guide for Windows 95/98/NT/2000

Administration Guide. . All right reserved. For more information about Specops Inventory and other Specops products, visit

DeltaV Event Chronicle

CA ARCserve Backup r16.x Professional Exam (CAT-360) Study Guide Version 1.1

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

NI DIAdem. Getting Started with DIAdem. Getting Started with NI DIAdem. July L-01

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

PRAGMA ENGINEERING Srl. Next-Generation ATS (Sistemi ATE di Nuova Generazione)

Pipeliner CRM Phaenomena Guide Administration & Setup Pipelinersales Inc.

Parallels Virtual Automation 6.1

CA Nimsoft Monitor. Probe Guide for Active Directory Response. ad_response v1.6 series

If you are not using a network environment (i.e. USB connection only) If you are using the printer in a network environment

VirtualCenter Database Performance for Microsoft SQL Server 2005 VirtualCenter 2.5

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

User Management Tool 1.6

Transcription:

USER GUIDE NI-TimeSync Version 1.1 Introduction, Installation, and Configuration About the NI-TimeSync Driver Software NI-TimeSync, shown in Figure 1, is a distribution of software synchronization plug-ins. You can use these plug-ins alone or alongside compatible hardware products including NI-Sync devices to create a synchronized system.

Time References Supported Hardware Requirements Figure 1. Multitarget System Using Synchronized Time NI-TimeSync supports IEEE 1588-2008. NI-TimeSync requires LabVIEW RT target hardware. NI-TimeSync User Guide 2 ni.com

Software Requirements NI-TimeSync requires LabVIEW RT 2009 SP1 or later. Application Software and Programming Language Support Installing the Software NI-TimeSync supports LabVIEW RT 2009 SP1 or later. Follow these steps to install the NI-TimeSync software: 1. Run setup.exe to install the software to the development machine. 2. Install the software to your LabVIEW RT target through Measurement & Automation Explorer (MAX). Note When installed to the LabVIEW RT target, the NI-TimeSync plug-in is set as the active plug-in. Configuration of other time references including Logos or SNTP overrides this configuration. Building and Programming Applications API Basics The NI-TimeSync plug-in automatically synchronizes the LabVIEW RT system date and time. The API is based on interacting with the system time. Two primary LabVIEW palettes useful in using the system time are Programming»Timing and Programming»Structures»Timed Structures. Programming»Timing This LabVIEW Timing palette, shown in Figure 2, includes functions for reading the current time, programmatic waits, and other useful functions. The timing used for each function is based on the synchronized LabVIEW date and time. National Instruments Corporation 3 NI-TimeSync User Guide

Figure 2. LabVIEW Timing Palette Programming»Structures»Timed Structures The Timed Structures palette, shown in Figure 3, allows you to control code execution using the Timed Loop and Timed Sequence structures. The built-in timing sources, shown in Figure 4, use the synchronized LabVIEW date and time. The absolute time sources, also shown in Figure 4, allow you to control the execution based on global time. Refer to your LabVIEW documentation for additional information. Figure 3. LabVIEW Timed Structures Palette NI-TimeSync User Guide 4 ni.com

Property Node Figure 4. Timed Loop Configuration You can use the NI-TimeSync property node to query the synchronization plug-in properties The property node is in the Programming»Structures»Timed Structures»Absolute Time palette. Monitoring Synchronization Status and Quality Timekeeper Synchronized This property returns whether the timekeeper is synchronized to the time reference within 1 ms. It is useful for program start-up to wait for synchronization to stabilize or to simply query the current state. Timekeeper Synchronization Disrupted You can query this latching property periodically to determine whether the timekeeper synchronization has been disrupted since it was last read. Disruption criteria include exceeding the 1 ms synchronization threshold or the time reference changing. You can use this property to determine whether a disruption to synchronization has occurred. National Instruments Corporation 5 NI-TimeSync User Guide

Example Programs The example programs are installed to your LabVIEW\examples\ TimeSync directory. The examples demonstrate methods of using a synchronized absolute time to coordinate multiple targets or chassis. These are simple, scalable fundamentals you can use to build powerful, distributed control and data acquisition applications. Start Timed Loop at Absolute Time.vi This example shows how to start a timed loop at an absolute time (LabVIEW timestamp) with a loop period specified in unit time (seconds). Scheduling Execution at Future Time Events.vi This example shows how to execute code at a series of defined future times. Timestamp Events.vi This example shows how to use the system time to timestamp an event (in this case, the action of a user clicking a button). LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2010 National Instruments Corporation. All rights reserved. 373185A-01 Nov10