CASTLE GROUP NOISE ACTIVATED SWITCH GA905 USER MANUAL

Similar documents
FIRERAY 2000 Installation Guide

CX Zoner Installation & User Guide

Contents. Safety Warnings... 1

Automatic Voltage Regulator User s Manual

SOUND LEVEL METER 94405

EM6556 e-domotica Mini Switch

Model SRMD Setra Remote Monitoring Display

Manual for Fire Suppression & Methane Detection System

Problem / Solution. The problem:

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

User's Guide. Integrating Sound Level Datalogger. Model Introduction

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

V94 BULK TAPE DEGAUSSER

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ACTIVE 5 ENGINEERING MANUAL

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Contents. Document information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SECURITY SYSTEM ADP-CAN

Installation & Operation Manual

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

Floodlight Range Installation Guide

User's Guide. Digital Sound Level Meter. Model

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

FIREDEX Conventional Fire Panels

INSTALLATION & SERVICE MANUAL. Display Panel

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Water Leak Detection System

GST301. (Single Protection Zone) Operation Manual

Operating instructions Capacitive sensors

Electronic Pressure Switch EDS 300

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

TIG INVERTER INSTRUCTION MANUAL

Installation guide H A. HSI hardwired system interface

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ACS-30-EU-EMDR-10-MOD

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

User's Guide Integrating Sound Level Datalogger Model

VK-250 WARRANTY REGISTRATION FORM

PART 1 PRODUCT (GENERAL)...1.

Telefon (+45) Telefax (+45) Installation and operating manual

MODEL 2202IQ (1991-MSRP $549.00)

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

HM-W536 Install Guide

IRT Eurocard. Types DAX-3200

Conventional Fire Detection and Extinguishant Control System Specification

ST Series POWER SUPPLIES USER INSTRUCTIONS

Model 1756 Test Lead Kit

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

650W Single Output Power Supply

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Power Generation. Power Control PCL System Generator Set Control

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

DCP Fan Controller. Version 01/2009. The engineer s choice

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

W O R L D C L A S S H I F I

Polyphase kwh Electricity Meter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

AlarmSense 2-wire detection and alarm system. Product Guide

SX460. Generator Automatic Voltage Regulator Operation Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

ADM1TE 5/30A DIN rail single phase two wire energy meter

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TMS TANK MANAGEMENT SYSTEM

12 Volt 30 Amp Digital Solar Charge Controller

ATL Fuel Level Sender Probes

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

MIC-WKT and MIC-WKT-IR

Drayton Digistat +2RF/+3RF

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

INV Series Sine-Wave Inverter. Manual INV12/220-XXXX KLC INV24/220-XXXX KLC INV48/220-XXXX KLC INV110/220-XXXX KLC INV220/220-XXXX KLC

1. SAFETY INFORMATION

Thyristor-controlled power supplies and battery chargers

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

Multi-Protocol decoder with Load regulation

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

I STAR COMPUTER CO., LTD

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

VDO ELECTRONIC SPEEDOMETER HALL EFFECT SENDER INSTALLATION INSTRUCTIONS AND WIRING DIAGRAM TYPE A SPEEDOMETER 4-WIRE SYSTEM 5(' %52:1 <(//2: :+,7(

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Meaco 30L and Meaco 40L dehumidifier instruction manual

FC6 FOOT CONTROLLER OWNER S MANUAL

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

MOUNTING AND OPERATING INSTRUCTIONS

Adjustment functions for both span and shift have been incorporated

Charge Regulator SCR 12 Marine

PART 1 PRODUCT (GENERAL)...1.

, User s Manual

Owner s Manual channel amplifier

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Transcription:

CASTLE GROUP NOISE ACTIVATED SWITCH GA905 USER MANUAL

COMPANY INTRODUCTION Thank you for buying a Castle product, we are sure you will find both the goods and the service to be of the highest quality but if not, then please feel free to write us so that we can deal with any concerns you may have. This manual is designed to show you the operation of the goods you have purchased. If you would like to become a competent person in the eyes of the law, then you may like to know more about our Competent Persons training courses for Human Vibration Risk Assessment and Noise at Work regulations. It is our aim at Castle Group Ltd to provide a complete range of Noise and Vibration products and Services of the highest standard. If you would like to know more about any of our other products and services then please complete the reply paid card in warranty registration form and return it to us for prompt action or telephone on : +44(0)1723 584250.

CONTENTS TITLE: PAGE: INTRODUCTION 1 INSTRUMENT DESCRIPTION 1 INSTALLATION 1 CONTROLS 2 CALIBRATION 2 SPECIFICATIONS 6 WARRANTY AND AFTER SALES SERVICE 8

1. INTRODUCTION. The Castle Groups GA905 instrument is designed to provide a mains level electrical signal.. In its standard form the output is low when off and high when on. All units are sold as 240V or 110V which must be specified at the time of ordering. 2. INSTRUMENT DESCRIPTION. The instrument is basically a standard sound level meter which drives a trip circuit to provide a switch function at a chosen level. The switch activates the output. After the noise level falls below the chosen trip level the output is reset after the preset delay time. Power is provided by the normal mains source. The unit is housed in a tough case. It is simply either screwed to the location point. 3. INSTALLATION. Choose a suitable location for the GA905. The microphone is usually mounted close to the main noise source. The box can be mounted at any convenient point using screws in the holes provided. Power must be provided from a 3A fused mains supply. The following connections must be made: Live (240V, 110V) J6/1 Neutral J6/2 Earth J6/3 The unit has a variable overall trip level from 75dB(A) to 112.5dB (A) in 2.5dB steps. The unit has a factory preset of 85dB(A). 1

3.1 Microphone The GA905 is supplied with a remote microphone. Connect the remote microphone by bringing the cable into the box bottom via one of the cable glands and connecting the wire to the PCB as follows: J1/1 power (red or brown) J1/2 signal (blue or white) J1/3 screen 5. CALIBRATION. The GA905 is set to trip at 85dB(A). This is the required sound pressure level at the microphone. This level can easily be adjusted from 75dB(A) to 112dB(A) by the user. However, it must be noted that to achieve a warning switch on level of say 85dB(A) at an operators ear position may mean setting the GA905 to work at a lower level (or sometimes higher) to compensate for the distance effects. From this it can be seen that the levels need to be measured both at the operators position and at the location site for the GA905. If a sound level meter is not available one may be purchased or hired from Castle Group Limited. Figure 5.1 shows the position of the following components on the PCB. 2

Figure 5.1 PCB ADJUSTMENTS. Mains Input TRIP INCREASE 1 Amp Fuse RV2 LK1 J6 TRANSFORMER 1 2 3 4 SW1 OPEN CLOSE J7 J1 J8 RV1 + Mains Out Microphone Cable 3

5.1 Calibration, RV1 This potentiometer gives +5dB adjustment to the calibration level and is factory set to match the microphone supplied. This control should not require any further adjustment. 5.2 Trip Time, RV2 This potentiometer may be adjusted to control the tripped period (lamp on period) from 5 seconds to 30 seconds. 5.3 Trip Level, SW1 This switch is used to set the trip level from 75dB(A) to 112.5dB(A) in 2.5dB increments. Access to the control board is gained by removing the top panel. All adjustments should be done with the power disconnected. Reconnect the power to test the unit. 5.4 Mains Output The mains outputs for the GA905 are as follows: Live J7/1 J8/1 Neutral J7/2 J8/2 Earth J7/3 J8/3 WARNING THERE ARE MAINS VOLTAGES PRESENT INSIDE THE UNIT WHEN SWITCHED ON 4

5.3 Trip Level, SW1 TRIP LEVEL SWITCH SW1 db 1 20dB 2 10dB 3 5dB 4 2.5dB 75 X X O O 77.5 X X O X 80 X X X O 82.5 X X X X 85 X O O O 87.5 X O O X 90 X O X O 92.5 X O X X 95 O X O O 97.5 O X O X 100 O X X O 102.5 O X X X 105 O O O O 107.5 O O O X 110 O O X O 112.5 O O X X O OPEN X CLOSED 5

8. Specification Trip Range 75dB to 112.5dB in 2.5dB steps switch selectable +5dB calibration control (factory set) Trip Time 5 seconds to 30 seconds user adjustable (potentiometer) When tripped unit automatically resets after trip time Frequency Weighting A weighted in accordance with BS EN 6051 Type 2 Time Weighting Slow 100mS in accordance with BS EN 6051 Type 2 Calibration Factory Calibrated Temperature Operating range: -10 to 50C Effect of temperature: <0.5dB from 30% RH to 90% RH Humidity Effect of Humidity: <0.5dB from 30% RH to 90% RH In the interest of continued development Castle Group Ltd reserve the right to change any specification without due notice. 6

7

9. Warranty and After Sales Service. Castle Group design and manufacture precision instruments, which if treated with reasonable care and attention should provide many years of trouble free service. In the event of a fault occurring, during the warranty period, the instrument should be returned to Castle Group Ltd., or to an authorised agent. Please enclose a clear description of the fault or symptom. Details of the warranty cover are available from Castle Group Ltd or an authorised agent. All instruments are designed to meet rigid British and International Standards. An annual calibration is recommended to ensure that these high standards are maintained. This is particularly important for cases in which instrument readings are to be used in litigation or compliance work. For warranty and service return to: The Service Department Castle Group Ltd. Salter Road Cayton Low Road Industrial Estate Scarborough North Yorkshire YO11 3UZ Telephone UK: (01723) 584250 INT: 44 1723 584250 Fax UK: (01723) 583728 INT: 44 1723 583728 E mail: sales@castlegroup.co.uk Internet Address: www.castlegroup.co.uk Any misuse or unauthorised repairs will invalidate the warranty. 8