HI Total Alkalinity Mini Titrator for Water Analysis

Similar documents
ph Alkalinity of Water

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

USEPA Electrode Method Method 8156

ph and Acidity in Wine and Fruit Juice

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

ph and Acidity in Tomato Sauce

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

ENE 806, Project Report 3 CHEMICAL PRECIPITATION: WATER SOFTENING. Grégoire Seyrig Wenqian Shan

Drop Counter Sensor Product Number: ENDRP-AD100

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Mitos P-Pump. product datasheet

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

ExStik TM ph Waterproof Meters

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Customer application report

UltraBasic Benchtop ph Meter Operation Manual

Karl-Fischer Titration the method for determining water

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Standard Methods for the Examination of Water and Wastewater

ph Measurement and Control

18 Conductometric Titration

Potentiometric determination. Application Bulletin 125/3 e. Branch General analytical laboratories; water analysis; beverages

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Measurement by Ion Selective Electrodes

Experiment 6 Titration II Acid Dissociation Constant

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Experiment 4 (Future - Lab needs an unknown)

DRINKING WATER - LAB EXPERIMENTS. Coagulation and flocculation LAB EXPERIMENTS. Jartest

Milwaukee USER MANUAL

SenTix 950 SenTix 980

Experiment 17: Potentiometric Titration

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

ph: Measurement and Uses

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Titrette. class A precision. The next generation Digital Burette!

Conductivity and TDS Meters

GA/7 Potentiometric Titration

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Total Suspended Solids Total Dissolved Solids Hardness

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

CHEMICAL PRECIPITATION: WATER SOFTENING

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Experiment 7: Titration of an Antacid

D. LAB 4. ACID-BASE TITRATIONS, ALKALINITY, AND BUFFER CAPACITY

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Electrical Conductivity of Aqueous Solutions

Ion Selective Electrodes

Acid Base Titrations

Acid Base Titration: ph Titration Curve

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Titrette. class A precision. The next generation Digital Burette!

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

ORGANIC SAMPLE PREPARATION

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

6 H2O + 6 CO 2 (g) + energy

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Temperature N Source and Rate CEC (less when high) Application method + H +

Journal of Innovations in Pharmaceuticals and Biological Sciences. A study on ph indicator property of flowers of Ipomea nil

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Free SO 2. by Aeration-Oxidation. A n o t h e r M o r e M a n u a l!

Compact ph Measuring Instruments

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Experiment 16-Acids, Bases and ph

Phosphorus, Reactive (Orthophosphate)

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

A Potentiometric Analysis of Fluoride Ion in Toothpaste

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Neutralizing an Acid and a Base

Continuous process of sodium bicarbonate production by Solvay method

Protocol: HPLC (amino acids)

Hot water extractable acidity or alkalinity of paper (Reaffirmation of T 428 om-08) (No changes from Draft 1)

PART 1 - INTRODUCTION...

Care and use guide. Contents. a handy solution made easy. page

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Solids, Volatile Dissolved and Fixed Dissolved

TRL-onlineTOC Monitor is designed for monitoring carbon content in

globe reactions made easy Process perfection

Experiment 3 Limiting Reactants

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

4-Channel Thermometer / Datalogger

Additional Lecture: TITRATION BASICS

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

Properties of Acids and Bases

Supplementry Discussion Topic: Advantages and disadvantages of current analytical approaches and the best carbon pair for you

THE USE OF OZONE IN COOLING TOWERS

Acid Base Titrations in Aqueous Solvents

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Bluelab Soil ph Meter Instruction Manual

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

How to measure Ammonia and Organic Nitrogen: Kjeldahl Method

Transcription:

HI 84531 Total Alkalinity Mini Titrator for Water Analysis

Piston Driven Pump with Dynamic Dosing The HI 84531 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the amount of titrant dosed as the end point is approached for increased accuracy in end point detection. Piston Burette Piston burettes provide an exceptionally reliable titrant delivery. This highly accurate dosing method is attained by combining a pulse controlled step motor with a 5 ml polypropylene syringe. The rigid and stable body of our syringe allows for less frequent pump calibration. Users no longer have to account for the changing elasticity of tubing associated with peristaltic pumps. More About Dynamic Dosing With the integration of our piston burette, our titrator can adjust the volume and frequency of titrant dosed based on relative mv changes in the testing solution. This titrant delivery system is known as dynamic dosing, where titrant is delivered in larger doses at the start of the titration and smaller doses near the endpoint. These differences in dosing volume and frequency result in a faster titration without sacrificing accuracy. With larger doses in the beginning of the titration, the speed of the titration is increased, where smaller doses near the end point allow for more time for the titrant and analyte to react. Smaller doses also prevent the over titration of a sample and a more accurate determination of titrant volume used. HI 1131B ph Electrode The HI 84531 is supplied with a refillable, double junction, combination ph electrode. By design, the HI 1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for any general acid/ base titration in the water industry.

HI 84531 Mini Titrator for Water Applications Piston Driven pump with Dynamic Dosing This piston driven dosing pump incorporates dynamic dosing to provide highly accurate, repeatable results. CAL CHECK CAL CHECK alerts users to potential problems during calibration such as contaminated buffers or dirty/broken electrodes. ph/mv M eter In addition to automatic titration, the HI 84531 can also be used as a ph/mv meter. Log-on-Demand Log data up to 400 samples (200 for titration; 200 for ph/mv). Graphic Mode/Exportable Data Displays in-depth data on titration, which can then be stored and exported to either a USB drive or PC using the USB connection. Automatic Stirrer Speed Control Maintains stirrer speed at approximately 600 rpm regardless of viscosity of solution. GLP Feature The HI 84531 includes a GLP Feature that allows users to view calibration data for the ph electrode and dosing pump. Easy to use interface User intuitive design with large keys and easy to navigate screens. ph Electrode The HI 84531 is supplied with the HI 1131B electrode. This versatile electrode can measure all types of water.

Easy to Use, Fast and Affordable All-in-one Solution The HI 84531 is a dedicated mini titrator and ph meter designed for low to high levels of alkalinity. It performs a potentiometric titration with a ph electrode to determines total titratable alkalinity and strong alkalinity in water. A titrant is slowly added to the sample while the ph and temperature are carefully monitored. The software analyzes the resulting titration curve and calculates the volume of titrant required to reach the endpoint. The user can choose either to measure strong alkalinity with a 8.3 ph end point (known as phenolphthalein alkalinity) or total alkalinity with a 4.5 ph endpoint (known as bromcresol green alkalinity). The dispensed titrant volume is used to automatically calculate the alkalinity, which can be displayed in mg/l or meq/l as CaCO 3. Titrations are conducted using the low range titrant HI 84531-50 (30 to 400 mg/l as CaCO 3 ) or the high range titrant HI 84531-51 (300 to 4000 mg/l as CaCO 3 ). This mini-titrator is also designed to be used as a benchtop ph/mv meter. As a ph meter, it has many features of a professional grade benchtop including automatic calibration up to 3 points with 4 available buffers, a 0.01 ph resolution, accuracy of +/- 0.01 ph, automatic temperature compensation and comprehensive GLP Data. The GLP data includes date, time, offset, slope, and buffers used for calibration. Accuracy is always ensured with Hanna s unique Cal-Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty/Broken, and overall probe condition as a percentage that is based on both the offset and slope characteristic of the electrode. The Cal-Check function not only ensures an accurate ph reading when the HI 84531 is used as a ph meter but also an accurate titration since the end point is determined by a set ph value. Why Total Alkalinity is So Important Water alkalinity is an expression of the capacity of water to neutralize an acid. It is calculated by determining the amount of acid required to adjust the ph by titrating to a fixed end point. A titration to ph 8.3 is considered Strong Alkalinity (SA), and in natural waters, represents the sum of carbonate (CO 3-2 ) and hydroxide (OH - ) present. A titration to ph 4.5 represents Total Alkalinity (TA), and is the sum of strong alkalinity plus bicarbonate (HCO 3 - ). The results are expressed as mg/l or meq/l as CaCO 3. Other compounds can contribute to alkalinity including phosphates, borates, silicates or organic acids. Water with low alkalinity will have a low buffering capacity and will take very little acid to change its ph. Water with high alkalinity will be buffered and require more acid to change the ph. In drinking water treatment, alkalinity is monitored due to the relationship with calcium (Ca +2 ) and magnesium (Mg +2 ) hardness. Water with high alkalinity will typically have high amounts of calcium and magnesium. In wastewater treatment, a level of alkalinity is required to neutralize the acid produced during the nitrification of ammonia/ ammonium (NH 3 /NH 4 + ) to Nitrite (NO 2 - ) then Nitrate (NO 3-2 ). For every 1.0 mg of ammonia converted to nitrate, 7.14 milligrams (mg) CaCO 3 equivalents are consumed. In denitrification, alkalinity is produced by the conversion of nitrate to nitrogen gas (N 2 ) at a rate of 3.57 mg CaCO 3 equivalents per mg of nitrate-nitrogen. The alkalinity must be monitored to maintain adequate levels which help maintain the ph of the process. In industrial water treatment, maintaining the alkalinity is important in order to prevent the ph from becoming acidic which would be corrosive to cooling towers and heat exchangers. But having too high of alkalinity can result in scaling reducing the efficiency of the system. The Hanna HI 84531 follows Standard Methods for the Examination of Water and Wastewater method 2320b and EPA method 310.1. All-in-One Water Titrator, ph Meter, Electrode and Magnetic Stirrer in one package

Features Setup Screens The LCD features an easy to use setup screen that allows the user to change measuring range, time, date, language and more. Tutorial and HELP Screens Accessing the tutorial menu provides helpful information during calibration and titration. Rear USB Outputs For PC connection and to export data to a USB drive 1 5 2 6 7 3 8 CAL CHECK Titration Curve Displayed On Screen 4 CAL CHECK is a Hanna exclusive process for checking the condition of electrodes which helps keep measurements accurate. GLP The GLP feature records electrode and pump calibration data to help keep measurements accurate and reliable. The HI 84531 offers real time graphing of the titration curve on the LCD. Log and Recall data The HI 84531 can log up to 400 samples (200 for titration results; 200 for mv/ph) and recall or export data to a USB stick or PC. Display 1) Current time and instrument mode information (ph meter or Titrator) 2) Procedural indicators 3) Instrument status 4) Virtual option keys 5) Stirrer and icon status During the instrument s operation a set of information are displayed on the LCD. Displayed icons: Stirrer on Pump running Wait for stable reading Procedure Warnings Adjustable Backlit LCD Stirrer is not working properly Parameter can be modified Users are warned if there is an error in procedures such as the use of a wrong buffer. The HI 84531 offers a backlit LCD with adjustable brightness levels. This ensures that the LCD is always easy to read. 6) Main reading information 7) ph temperature compensation mode (Manual or Automatic) 8) Temperature reading

Specifications Titrator HI 84531 -Total Alkalinity Low : 50 ml sample 30.0-400.0 mg/l as CaCO 3 0.6-8.0 meq/l as CaCO 3 High : 50 ml sample 300-4000 mg/l as CaCO 3 6.0-80.0 meq/l as CaCO 3 Low : 0.1 mg/l; 0.1 meq/l High : 1 mg/l; 1 meq/l Accessories Reagents HI 84531-50 Titrant Solution for Low (120 ml) HI 84531-51 Titrant Solution for High (120 ml) HI 84531-55 Pump Calibration Standard for Low and High (230 ml) Accuracy (@25ºC/77ºF) Method Principle Pump speed Stirring Speed Logging Data ph Meter Low : 3% of reading or ± 1 mg/l, whichever is greater High 3% of reading or ± 10 mg/l, whichever is greater acid-base titration (total alkalinity / strong alkalinity) end point titration : 4.50 ph / 8.30 ph 10 ml/min 600 rpm up to 200 samples -2.0 to 16.0 ph / -2.00 to 16.00 ph 0.1 ph / 0.01 ph Accuracy (@25ºC/77ºF) ±0.01 ph Calibration 1, 2 or 3 calibration points; 4 available buffers (4.01, 7.01, 8.30, 10.01) Temperature Compensation manual or automatic from -20 to 120 C (-4 to 248 F) Logging Data Up to 200 samples (ph and mv) mv Meter Accuracy Logged Data Temperature Accuracy Additional Specifications -2000.0 to 2000.0 mv 0.1 mv ± 1.0 mv Up to 200 samples (ph or mv) -20.0 to 120.0 C (-4.0 to 248.0 F) 0.1 C ±0.4 C without probe error ph Electrode HI 1131B glass body, refillable, with BNC connector and 1 m (3.3 ) cable (included) Temperature Probe HI 7662-T stainless steel temperature probe with 1 m (3.3 ) cable (included) Environment 0 to 50 C (32 to 122 F); RH max 95% non-condensing Power Supply 12 VDC adapter (included) Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9 ) Weight 1.9 kg (67.0 oz.) ph Calibration Solutions HI 7004M HI 7007M HI 70083M HI 7010M Buffer solution ph 4.01 (230 ml) Buffer solution ph 7.01 (230 ml) Buffer solution ph 8.30 (230 ml) Buffer solution ph 10.01 (230 ml) Electrode Fill and Storage Solutions HI 70300L Electrode storage solution (500 ml) Electrode Cleaning Solution HI 7082 HI 7061M Electrodes HI 1131B HI 7662-T Electrode fill solution (4 x 30 ml) Electrode Cleaning Solution (230 ml) ph Electrode Other Accessories HI 70500 HI 71005/8 HI 71006/8 HI 731319 HI 740036P HI 740236 HI 920013 Temperature probe Tube set with cap for titrant bottle, tip and valve 115 Vac to 12 Vdc, 800 ma 230 Vac to 12 Vdc, 800 ma Stir bar, 25 x 7 mm (10 pcs.) 100 ml Beaker (10 pcs.) 5 ml Syringe for minititrator PC Connection Cable Ordering Information HI 84531-01 (115V) and HI 84531-02 (230V) are supplied with: HI 84531-70 Reagent Kit for titratable acidity in water products HI 1131B ph electrode HI 7662-T temperature probe HI 740036P Two 100 ml beakers HI 70500 Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), Dosing Pump Valve HI 740236 1mL syringe HI 731319 5 ml Syringe (sample stir bar measurement) HI 920013 power adapter instruction manual and quality certificate Hanna Instruments Inc. 584 Park East Drive, Woonsocket, RI 02895 401-765-0045 www.hannainst.com