How To Test For Premer Retardant

Similar documents
Fire Life Safety ORC Review Guidelines for PPD Experimental Installations

WHITE PAPER Fire & safety performance standards

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

furnishings flammability characteristics

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Fire Performance Standard

Fire Testing of Recycled Materials for Building Applications

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

Approval Standard for Plastic Suspended Ceiling Panels

Terms and Definitions In Canada

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Pyroguard Wired Glass

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

Dubai Municipality Standard DMS 1: Part 5: 2004

FLAMMABILITY REQUIREMENTS FOR AIRCRAFT SEAT CUSHIONS

Excerpts from the Canadian National Building Code (NBC)

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

1-085 Fire safety performance of materials

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Flame Retardants and the Evolving Regulatory Landscape

PAINT BOOTH LIGHTING

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Tremco Fire Protection Systems Group Technical Bulletin

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

Test Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

A.17. OXIDIZING PROPERTIES (SOLIDS)

Fire or Ignition Resistant? Building Materials & Vegetation

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Understanding BS EN 771-3: Aggregate concrete masonry units

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

SPECIFICATION FOR NOISEMASTER SOUND CONTROL PRODUCTS. Noisemaster Sailcloth Baffles shall be manufactured by THE PROUDFOOT CO., INC., Monroe, CT.

Test report No

Meeting the Fire Code with Continuous Foam Plastic Insulation

Specifications, Product Testing and Terminology

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

TECHNICAL BULLETIN

OFM-TG Office of the Fire Marshal F M. Handling Flammable and Combustible Liquids in School Laboratories GUIDELINE

2010 edition. Handbook of. Fire-Rated Glass. for schools

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Fire-Rated Glass and Glazing START

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

Selective Laser Sintering of Duraform TM Polyamide with Small-Scale Features

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

New Cable Tie Type Classifications

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Bus Fire Safety in China. James Wang China Bus & Coach Yearbook

Fiberglas, Exterior Wall Thermal Insulation

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

IH E Sigma Island 90

HOT WORK PERMIT PROGRAM TRAINING. John Braun

CaribeanCommunity EDICTOFGOVERNMENT±

Engineering Plastics Technical Presentation

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

Details of the instrument calibration are maintained in laboratory records.

Queen's University Environmental Health and Safety

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

HEAVY DUTY STORAGE GAS

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Underwriters Laboratories Testing Information

T a b l e o f C o n t e n t s

MAGNETIC CARD READER DESIGN KIT TECHNICAL SPECIFICATION

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Certification of Plastic Materials

Two Test Methodologies for Evaluating the Resistance to Electrical Arcing Properties of Polymeric Materials for use in Automotive 42 V Applications

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

IPC-SM-840C. Qualification and Performance of Permanent Solder Mask IPC-SM-840C. The Institute for. Interconnecting. and Packaging Electronic Circuits

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

4 Thermomechanical Analysis (TMA)

orlando OWNER S MANUAL

Universal MATE-N-LOK Connectors

BRE Global Test Report

Thomas and Betts Corporation Product Guide Specification

Thermal Management Solutions for Printed Circuit Boards used in Digital and RF Power Electronics and LED assemblies

Building Cables and Wires

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

SL280UHV SERIES GAS FURNACE WARNING

COMPARISON OF VARIOUS SINGLE PLY ROOF COVERS FOR FIRE RESISTANCE

Fire Classification Rating Testing of Stand-Off Mounted Photovoltaic Modules and Systems

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES


Errata NFPA 1. Fire Code Edition

Transcription:

TEST REPORT NEBS COMPLIANCE CHOMERICS PREMIER CONDUCTIVE PLASTIC Prepared by: CHOMERICS R&D 84 DRAGON COURT WOBURN, MA 01801 Test Report Number: TR 1007 EN 0206 Chomerics Approved Signatory: This report shall not be reproduced except in full without the written approval of Chomerics. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. PREMIER is a trademark of Parker Hannifin Corporation. Chomerics is a registered trademark of Parker Hannifin Corporation February 2006. All rights reserved. Page 1 of 5

1. INTRODUCTION This document is written to report compliance as specified by Network Equipment Building System (NEBS) for PREMIER fire retardant (FR) grades. The requirements are in accordance with GR-63-CORE: Network Equipment Building System (NEBS) Requirements: Physical Protection. The full document can be obtained from Telcordia Technologies, Inc. NEBS is a systems test, therefore PREMIER complies with sections pertaining to material selection. Section 4.2.3, Use of Fire-Resistant Materials, Components, Wiring, and Cable is the pertinent section of the document that PREMIER complies to. NEBS is the most common set of safety, spatial and environmental design guidelines applied to telecommunications equipment in the United States. NEBS is not a legal requirement, but a customer requirement of service providers in order to preserve network integrity. 2. ADMINISTRATIVE DATA 2.1 Test Facility Testing is done both internally at Chomerics and externally by independent laboratories. All UL94 testing is done by Underwriters Laboratory (UL). The results and/or conclusions within this test report refer and/or apply only to the unit(s) tested as defined by this report. 3. TEST SET UP AND CONFIGURATION 3.1 Section 4.2.3 Requirements Compliance to section 4.2.3, Use of Fire-Resistant Materials, Components, Wiring, and Cable requires the material to meet the requirements of section 4.2 of ANSI T1.307-1990, Fire-Resistance Criteria Part 1: Ignitability Requirements for Equipment Assemblies, and Fire Spread Requirements for Interconnection Wire and Cable Distribution Assemblies. The requirements of section 4.2 of ANSI T1.307-1990 require the following to be met: -The material shall have an oxygen index of 28% or greater as determined by ASTM D 2863-77, Standard Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index) and - The material shall have a 94 V-1 or better rating as determined by Underwriters Laboratory (UL) 94, Test for Flammability of Plastic Materials for Parts in Devices and Appliances, per the paragraph titled Vertical Burning Test for Classifying Materials 94 V-0, 94 V-1 or 94 V-2. Page 2 of 5

3.2 Section 4.2.3 Apparatus and Test Specimen 3.2.1 Complete descriptions of the apparatus and test specimens for ASTM D 2863-77 are outlined in the standard. Copies of the standard may be obtained from the American Society for Testing and Materials (ASTM). Test Apparatus Test Chimney- consisting of a heat resistant glass tube. Specimen Holder Any small holding device that will support the specimen at its base and hold it vertically in the center of the chimney. Gas Supplies comprising pressurized sources of oxygen or nitrogen, or both. Gas Measurement and Control Devices Flame Igniter Timing Device Fume Extraction System Thin Film Rolling Tool 3.2.2 Test Specimen PREMIER test specimens are molded and machined to the proper size. Test specimen dimensions are: Length: 80-150 mm Width: 10 +/-.5 mm Thickness: 10.5 mm 3.3 Summary of Test Method Complete details of the test method and procedure can be obtained from the American Society for Testing and Materials (ASTM). This test method provides for the measuring of the minimum concentration of oxygen in a flowing mixture of oxygen and nitrogen that will just support flaming combustion of plastics. A small test specimen is supported vertically the mixture of oxygen and nitrogen flowing upwards through a transparent test chimney. The upper end of the specimen is ignited and the subsequent burning behavior of the specimen is observed to compare the period for which burning continues, or the length of the specimen burnt, with specified limits for each burning. By testing a series of specimens in different oxygen concentrations, the minimum oxygen concentration is determined. This value is referred to as the oxygen index (OI) and expressed as volume percent. The PREMIER materials tested are A220-FR, A230-FRHF, A240-FRHF. Page 3 of 5

3.4 UL 94 Requirements The requirements of section 4.2 of ANSI T1.307-1990 also require the material to have a 94 V-1 or better rating as determined by Underwriters Laboratory (UL) 94, Test for Flammability of Plastic Materials for Parts in Devices and Appliances, per the paragraph titled Vertical Burning Test for Classifying Materials 94 V-0, 94 V-1 or 94 V-2. The UL 94 Flammability ratings are intended to provide an indication of a material s ability to extinguish a flame, once ignited. Ratings are primarily differentiated by the testing method. Summary of the UL 94 rating categories: 5VA (surface burn): Test specimens may not have a burn through (no hole). This is the highest (most flame retardant) UL94 rating. 5VB (surface burn): Test specimens may have a burn through (a hole). V-0 (vertical burn): Burning stops within 10 seconds. No flaming drips are allowed. V-1 (vertical burn): Burning stops within 30 seconds. No flaming drips are allowed. V-2 (vertical burn): Burning stops within 30 seconds. Flaming drips are allowed. H-B (horizontal burn): Slow burning on a horizontal specimen burning rate. This is the lowest (least flame retardant) UL94 rating. PREMIER FR grades have already been certified for UL V-0 at specified thicknesses. PREMIER conductive plastics are undergoing certification for UL94-5V. 3.4.1 UL 94 Vertical Testing Procedure Figure 1: UL 94 V-0, V-1, V-2 Vertical Testing Procedure The 94V Vertical Burn Test uses a standard bar specimen which is held at one end in the vertical position. A burner flame is applied to the free end of the specimen for two 10 second intervals separated by the time it takes for flaming combustion to stop after the first application. Two sets of 5 specimens are tested. Burning times, glowing times, when dripping occurs, and whether or not the cotton beneath ignites, are all noted. Flaming drips, widely recognized as a main source for the spread of flames, distinguish V1 from V2. Page 4 of 5

4. TEST RESULTS 4.1 Oxygen Index Test Results for PREMIER FR materials. Material Oxygen Index (%) A220-FR 32.4 A230-FRHF 36.0 A240-FRHF 36.0 Oxygen index values are averages of several samples. Test was run per ASTM D 2863, Measuring The Minimum Oxygen Concentration To Support Candle-Like Combustion of Plastics (Oxygen Index). 4.2 UL 94 Flammability Certification PREMIER CONDUCTIVE PLASTICS UL 94 FLAMMABILITY CERTIFICATIONS Material Rating Thickness A220-FR V-0 1.5 mm A230-FRHF V-0 1.5 mm A240-FRHF V-0 1.8 mm* All materials are currently under certification testing for UL94-5V rating. * A240-FRHF has been tested at Chomerics and passed at 1.8 mm. Testing at UL is underway for certification for V-0 at 1.8 mm. ** For a more detailed report on UL 94 testing for PREMIER, please refer to Chomerics report TR 1001 EN 0106. 5. NEBS COMPLIANCE The test results reported above show PREMIER FR grades comply with GR-63-CORE: Network Equipment Building System (NEBS) Requirements: Physical Protection, section 4.2.3, Use of Fire-Resistant Materials, Components, Wiring and Cable as it relates to the materials. All the FR grades of PREMIER meet both the requirements in ANSI T1.307-1990 by having an oxygen index of 28% or greater and having a UL 94 V-1 or better rating. Page 5 of 5