T1/E1 Copper-to-Fiber Slide-In-Module Media Converters USER S GUIDE COMPLIANCE INFORMATION C/T1E1-CF-01



Similar documents
T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE COMPLIANCE INFORMATION. SSDTF10xx*-100

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter

Part Number Port One - Copper Port Two - Duplex Fiber-Optic. 2 km (1.2 miles)* SCSCF ohm coax (BNC) SC, 1300 nm multimode,

T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE

Model 0400 (800) MODEL 0400 ETHERNET POCKET HUB SPECIFICATIONS (E-TBT-HB-0400) Standards. Physical

FlexPoint T1/E1 Copper to Fiber Line Driver

Transition Networks CPSMC19xx Slot PointSystem Chassis. User s Guide (revision C) CPSMC CPSMC

POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide

HP ProCurve High-Speed Transceivers Installation Guide

F2400 FOM II Series Fiber Optic Modem Technical Manual

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

Perle 10/100 Ethernet Media Converters

About the HotWire Slot Standalone Shelf

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Perle 10/100/1000 Ethernet Media Converter Module

MCR1900 Media Converter 19-Slot Chassis

Technical Support. Support Information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Gigabit Switching Ethernet Media Converters - Product User Guide

Power Over Ethernet Adapters POE101

Perle Protocol Transparent Media Converter Modules

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Cable Specifications. T3 Trunk Cabling APPENDIX

T1/E1 twister MAN MAN MAN. Installation & User Guide

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

UIM-2T1 T1 Loop Bonding Uplink Interface Module

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

FOM-5A, 6A. Asynchronous Fiber Optic Modem

AXIS 291 1U Video Server Rack Installation Guide

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Perle Gigabit Fiber to Fiber Media Converters

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Perle Fast Fiber to Fiber. Media Converters

MDI/MDIX) FEP-32008T-3

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Gateway Port Replicator User Guide

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

FIBER OPTIC A/B/C SWITCH (Latching)

imcv-t1/e1/j1 Repeater

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

AXIS T81B22 DC 30W Midspan

Moxa EtherDevice Switch

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

TDMoEthernet. Description

PoE+ Extender Switch User's Manual. Rev W

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

10/100/1000 Base-T to Gigabit Fiber Media Converter

ONLINE LAUNCHER. Choose one of the following: RADEON Products. HydraVision. Compliance Information

LMR16TC Mini 10BASE-T Repeater. Installation Guide

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

User Guide. Introduction. Contents. Models / Part Numbers. 100-Base-FX Network Interface Cards (NICs)

24-Port Channelized E1/T1 Line Card Overview

2-Pair HDSL1 Adtran Fiber Optic Link System

Product Documentation on the World Wide Web

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

EZ Connect. Quick Install Guide SMC8002CM-US

IE-iMcV-T1/E1/J1-LineTerm SFP and 1x9 Operation Manual

AT-GS2002/SP. Gigabit Ethernet to Fiber SFP Media Converter. AT-GS2002/SP Media Converter Installation Guide. PN Rev. A

Power Supply Guide Version 1.0 for D-Show

HARTING econ 3000 Introduction and features

8-Port PoE Network Switch

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

Loop-IP6700 TDMoEthernet

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Transition Networks CPSMC Slot PointSystem Chassis. User s Guide (revision A)

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

WARNING CANADIAN D.O.C. WARNING

IFS SP-PoE Splitter User Manual

TAM Port T1 Access Multiplexer

This is a product of VCCI Class B Compliance

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

FCC COMPLIANCE STATEMENT

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Transcription:

COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user s own expense. Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. European Regulations Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées CAUTION: RJ connectors are T INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network. Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität. T1/E1 Copper-to- Slide-In-Module Media Converters C/T1E1-CF-01 USER S GUIDE Designed to be installed in the TRANSITION Networks E-MCC-1600 Media Converter Chassis, C/T1E1-CF-01 series media converters encode and decode T1 OR E1 signals over duplex fiber cables to extend the distance and transmission reliability of high speed T1 and E1 data traffic. C/T1E1-CF-01 RX and TX ST connectors to 850 nm multimode fiber-optic cable. C/T1E1-CF-01(SC) RX and TX SC connectors to 850 nm multimode fiber-optic cable. C/T1E1-CF-01(SM) RX and TX ST connectors to 1300 nm singlemode fiber-optic cable. C/T1E1-CF-01(LH) RX and TX ST connectors to 1300 nm singlemode fiber-optic cable. Trademark Notice All registered trademarks and trademarks are the property of their respective owners. Copyright Restrictions 1999-2001 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means graphic, electronic, or mechanical without written permission from TRANSITION Networks. Printed in the U.S.A. 33111.D C/T1E1-CF-01 in the Network.....2 Installation....................4 Operation.....................7 Fault Isolation and Correction.....8 Cable Specifications............10 Technical Specifications.........11 Compliance Information.........12

C/T1E1-CF-01 IN THE NETWORK TE: THE C/T1E1-CF-01 REQUIRES A CSU BETWEEN THE MEDIA CONVERTER AND THE PUBLIC TELEPHONE NETWORK. OR E1 U/S E1 T1 OR E1 Network Extension TECHNICAL SPECIFICATIONS Standards Emissions: CISPR A T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI Case Dimensions 4.75" x 3.0" x 2.0" (119mm x 76mm x 50mm) Shipping Weight 3 pounds (1.4 kilograms) Delay 400nsec round trip Environment Temperature: 0-50 C (32 to 122 F ) Humidity 10-90%, non condensing Altitude 0-10,000 feet Power Supply Requirements Replace power supply with only the equivalent input rating (see below) and output rating (unregulated 9-24VDC, 5.5W). TN PN Requirement Location 3507 240 volts, 50 hertz United Kingdom 3342 230 volts, 50 hertz Europe 3340 120 volts, 60 hertz USA/Canada/Mexico 3346 100 volts, 50-60 hertz Japan 35140 volts, 50 hertz Australia 3537 (with power cord: 3522) South Africa TE: This product also can be powered by the Transition Networks E-MCR series media converter rack. Warranty Lifetime E1 OR Features CSU To Telco OR To Telco Media converter is framing independent (as ESF vs D4) and supports all common line codes, (AMI, B8ZS, HDB3). Distance extensions of 2 km 850 nm multimode or 8 km 1300 nm singlemode. Jitter attenuators optimize Bit Error Rate (BER) performance. Dry relay contacts allow media converter to be tied into separate alarm circuit DECLARATION OF CONFORMITY Name of Mfg: Transition Networks 6475 City West Parkway, Minneapolis MN 55344 USA Model: C/T1E1-CF-01 Series Copper-to- Media Converter Part Number: C/T1E1-CF-01, C/T1E1-CF-01(SC), C/T1E1-CF-01(SM), C/T1E1-CF-01(LH) Regulation: EMC Directive 89/336/EEC Purpose: To declare that the C/T1E1-CF-01 and C/T1E1-CF-01(SM) to which this declaration refers is in conformity with the following standards. EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Stephen Anderson, Vice-President of Engineering _June 8, 1999 Date All Ones Insertion (AIS), indicated by LEDs, on loss of signal at copper and/or fiber interface.

CABLE SPECIFICATIONS Cable Bit error rate: 10-9 MULTIMODE Optic Cable Recommended: 62.5 / 125 µm multimode fiber Optional: 100 / 140 µm multimode fiber 85 / 125 µm multimode fiber 50 / 125 µm multimode fiber C/T1E1-CF-01 850 nm Optic Transmitter Power: min: -14.0 dbm max: -12.0 dbm Optic Receiver Sensitivity: min: -25.0 dbm max: -12.0 dbm Typical Maximum Cable Distance*: 2 kilometers C/T1E1-CF-01(SC) 850 nm -optic Transmitter Power: min: -14.0 dbm max: -12.0 dbm -optic Receiver Sensitivity: min: -25.0 dbm max: -12.0 dbm Typical Maximum Cable Distance*: 2 kilometers SINGLEMODE Optic Cable Recommended: 9 µm singlemode fiber C/T1E1-CF-01(SM) 1300 nm -optic Transmitter Power: min: -21.0 dbm max: -14.0 dbm -optic Receiver Sensitivity: min: -25.0 dbm max: -14.0 dbm Typical Maximum Cable Distance*: 8 kilometers C/T1E1-CF-01(LH) 1300 nm -optic Transmitter Power: min: -15.0 dbm max: -5.0 dbm -optic Receiver Sensitivity: min: -25.0 dbm max: -14.0 dbm Typical Maximum Cable Distance*: 15 kilometers *Actual distance dependent upon physical characteristics of network installation. -Pair Copper Cable pair connection requires two active pairs. The two active pairs in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue) for the active pins. Category 3 or better twisted-pair copper wire is required. Either shielded twistedpair (S) or unshielded twisted-pair (U) can be used. T1: Gauge 24 to 22 AWG Attenuation 2.6 db/100 meters @ 1.0 MHz Differential Characteristic Impedance 100 Ω ±10% å E1: Gauge Attenuation Differential Characteristic Impedance 120 Ω ±10% Coax Copper Cable E1: 24 to 22 AWG 2.6 db/100 meters @ 1.0 MHz Gauge 24 to 22 AWG Attenuation 2 db/100 meters @ 1.0 MHz Differential Characteristic Impedance 75 Ω ±10% Dry-Contact Relay RJ-45 dry-contact relay opens if power, signal detect/copper or signal detect/fiber are lost. Operational rating on pins 3 and 6: Switch-Selectable Configurations T1 COPPER RJ-45 0-30VDC maximum 1A Configured as either "long haul" or short haul on, with a variety of selectable distance settings. E1 COPPER RJ-45 Configured as either "long haul" or short haul on 120 ohm cable. E1 COPPER COAX Configured as either "long haul" or short haul on 75 ohm cable. STRAIGHT-THROUGH/CROSSOVER RJ-45 Allows straight-through cable to be used where crossover-configuration cable is required. Switch-Selectable Functions LOOPBACK TEST FUNCTION A loopback switch facilitates installation and network debug procedures. Relay The path for the C/T1E1-CF-01 loopback is shown: TRANSMIT ALL ONES FUNCTION 3 6 RJ-45 A selectable Transmit All Ones switch on the fiber interface and on the twisted-pair interface allows for insertion of an all ones pattern on that

INSTALLATION Set Switches Use small flatblade screwdriver or similar device to set recessed switches for site installation. Refer to label on top of media converter for MDI/ MDI-X switch settings. Refer to drawings below and at right for four-position switch settings. KEY = UP SHORT HAUL Switch Settings Switch #4 UP 3 4 3 4 5 6 7 8 E.37V 75 ohm cable Coax connectors AIS 5. Is the AIS LED on either media converter illuminated? Determine and correct failure of remote unit connected to twistedpair interface that caused All Ones Insertion (AIS) on the twistedpair interface. = DOWN E1 3.0V 120 ohm cable RJ-45 connector *LONG HAUL Switch Settings Switch #4 DOWN 3 4 DSX-1 0'-133' 0 db DSX-1 133'-266' -7.5 db DSX-66'-399' -15 db DSX-1 399'-533' -22.5 db DSX-1 533'-655' *Switch #3 not used for long haul settings. ANSI T1.403 DSX-1 6.0V

FAULT ISOLATION and CORRECTION If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action: 1. Is the Power LED on the media converter illuminated? Is the power adapter the proper voltage and cycle frequency for the AC outlet? TE: Refer to the Power Supply Requirements on page 7. Is the power adapter properly installed in the media converter and in the outlet? Proceed to step 2. 2. Is the SD (Signal Detect/) LED illuminated? Check fiber cables for proper connection. Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on other media converter. Proceed to step 3. 3. Is the SD (Signal Detect/-Pair) LED illuminated? Check twisted pair cables for proper connection. Check RJ-45 Pinning Switch for correct twisted pair cable configuration. Check integrity of device attached to media converter by twistedpair cable. Proceed to step 4. 4. Is the AIS LED on either media converter illuminated? Proceed to step 5. Determine if broken fiber link has caused All Ones Insertion (AIS) on the fiber interface and correct failure. If not, proceed to step 5. Set switches 5, 6, and 7 to enable test functions or to permit normal network operation. (Switch 8 not used.) *NETWORK Switch Settings 5 6 7 8 *Switch #8 not used. 3 4 5 6 7 8 Normal Operation Loop Transmit to Receive Transmit All Ones onto on loss of SD Transmit All Ones onto Transmit All Ones onto on loss of SD Transmit All Ones onto -Pair Set the MDI/MDI-X switch to use straight-through cable where crossoverconfiguration cable is required. Pair #1 1 2 KEY = UP = DOWN MDI Pair #1 1 2 MDI-X Pair #2 4 5 Pair #2 4 5 AIS Connectors for unlike devices Connectors for like devices

INSTALLATION (continued) Install Slide-In-Module in E-MCC-1600 Chassis TE: Media Converter Slide-in-Modules can be installed in any installation slot, in any order. Remove Media Converter Slide-in-Module protective plate from selected installation slot by removing two (2) screws that secure plate to front of E-MCC-1600. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides. TE: Ensure that the Media Converter Slide-in-Module is firmly seated against the backplane. Secure Slide-in-Module by securing panel fastener screw attached to Slide-in-Module to E-MCC-1600 chassis. Install Cable COPPER T1 100 OHM (RJ-45 CONNECTOR) OR E1 120 OHM (RJ-45 CONNECTOR) TE: KEEP TWISTED-PAIR RUNS AS SHORT AS POSSIBLE. Locate or build twisted-pair cables that are compliant with specifications on page 10. Connect male RJ-45 plug connector at one end of cable to media converter RJ-45 jack connector. Set MDI/MDI-X switch to MDI-X according to network conditions. Connect male RJ-45 plug connector at other end of cable to network equipment.. E1 75 OHM (COAX CONNECTOR) TE: Ground coax segment to earth ground at one end. Locate or build coax cables that are compliant with specifications on page 10. Connect BNC connector at one end of cable to media converter. Connect BNC connector at other end of cable to network equipment.. FIBER Locate or build duplex fiber cables that are compliant with specifications on page 10. Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on media converter. Connect male TX and RX cable connectors at other end of cable to RX and TX connectors of compliant fiber device. Connect to Power OPERATION Install Power Adapter cord at back of Media Converter. Connect Power Adapter plug to AC power. Verify that Media Converter is powered by observing illuminated LED(s). After installation, the media converter should function without operator intervention. Status LEDs Use the status LEDs to monitor media converter operation in the network. Power Steady green LED indicates connection to external AC power. SD Signal Detect/ - Steady green LED indicates fiber link is up. Power SD AIS Coax SD AIS AIS All Ones Insertion/ - Blinking green LED indicates all ones received on fiber Coax Steady green LED indicates coax interface selected. SD Signal Detect/-Pair - Steady green LED indicates twisted-pair link is up. AIS All Ones Insertion/-Pair - Blinking green LED indicates all ones received on twisted-pair