Transition Networks CPSMC Slot PointSystem Chassis. User s Guide (revision A)
|
|
|
- Mitchell Horn
- 9 years ago
- Views:
Transcription
1 Transition Networks CPSMC Slot PointSystem Chassis User s Guide (revision A)
2 Compliance Information UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user s own expense. Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A & B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. European Regulations Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées CAUTION: THE RJ CONNECTORS ON THE INDIVIDUAL MEDIA CONVERTER SLIDE-IN-MODULES ARE NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network. Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität. Trademark Notice All trademarks and registered trademarks are the property of their respective owners. Copyright Restrictions 2003 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means graphic, electronic, or mechanical without written permission from Transition Networks. Printed in the U.S.A A 2
3 Table of Contents 1 Introduction Description Unpacking the CPSMC Equipment Slide-in-Modules Media Converter Slide-in-Modules Calculating Power Consumption Installing Media Converter Slide-in-Modules Replacing Media Converter Slide-in-Modules Managment Modules Three Types of Management Modules Installing the Management Modules Replacing the Management Modules Powering the CPSMC Primary Power Supply Auxilliary Power Supply CPSMC Chassis Installing the CPSMC Chassis Standard 19-Inch Rack Installation Table-Top Installation Cascade Option Connecting the Slide-in-Modules to the Network Operation SNMP Agent in the Management Module SNMP Hardware Connections SNMP Software Fault Isolation and Correction Technical Specifications Cable Specifications Contact Us Warranty
4 TERM INIT 12C 12C-1 10/100 10/100 1 Introduction 1.1 Description The Transition Networks PointSystem CPSMC is a 19-inch, rack-mountable chassis for selected Transition Networks Media Converter Slide-In-Modules. The CPSMC allows the network administrator to connect various copper and fiber-optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12. The CPSMC provides installation space for up to eight (8) single-slot or four (4) dual-slot Media Converter Slide-in-Modules in the front of the unit. Management Module Installed Slide-In-Module Open Slot Power Inlet introduction SPD F C INPORT OUTPORT SPD F C The CPSMC also comes equipped with an AC or DC power supply. An optional AC or DC power supply with Instant Fail Over operation is also available. The primary power supply is accessed through the Power Inlet on the front panel, while auxilliary power is accessed through the Auxilliary Power Inlet, located on the back panel. Auxilliary Power Inlet Four fans, two for the power supplies and two for the Slide-In-Modules, help remove heat from the chassis. With installed PointSystem Management Module(s) (TN part number CPSMM- 120, -200, or -210), the CPSMC can be managed and monitored via: An SNMP application such as Transition Networks FocalPoint management software installed at a remote Network Management Station (NMS). A remote Web browser. A command-line interface (CLI) at an attached terminal. A command-line-interface (CLI) at a remote Telnet connection. The management features include: Power control (slot on, slot off, in rush limit) for each individual slot. Internal temperature monitor. Fan failure monitor. Chassis power consumption monitor. Power supply type identification. Power supply condition monitor. Fail-over power detection. The Management Modules also make it possible to control up to eight (8) cascaded CPSMC chassis, which can accomodate up to 55 installed Media Converter Slide-in-Modules. 4
5 2.1 Unpacking the CPSMC Equipment Use the following list to verify the shipment: Item Part Number 8-Slot chassis with AC power supply CPSMC Slot chassis with DC power supply CPSMC introduction Power Cord External AC Power Supply External DC Power Supply 1-slot Master Management Module 2-slot Master Management Module FocalPoint Software Disk Expansion Management Module Management Module Cascade Connector Rack Mount Ears Selectable Media Converter Slide-in-Module(s) (varies by country) CPSMP-180 (optional) CPSMP-190 (optional) CPSMM-100 (optional) CPSMM-200 (optional) FPS (provided with CPSMM-200) CPSMM-210 (optional) 6026 (optional) CPSRE-238 (optional) (various P/N) - (optional) User s Guide
6 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules Transition Networks Media Converter Slide-in-Modules, installed in slots at the front of the chassis, allow the network administrator to connect various copper and fiberoptic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12 as well as many others (see for a complete listing.) NOTE: Refer to the documentation that comes with each Media Converter Slide-in- Module for cable, connector, and LED indicator information specific to that Media Converter Slide-in-Module Calculating the Power Consumption CAUTION: Before installing the Media Converter Slide-in-Modules, refer to the power consumption data for each individual Media Converter Slide-in-Module (provided in the User s Guide shipped with each Media Converter Slide-in- Module). The combined power consumption of all devices must not exceed the available power supply. Failure to observe this caution could result in diminishing system reliability. slide-in-modules In other words, the combined wattage of the CPSMC Slot chassis plus all Slide-In-Modules must be less than the available power. Contact Transition Networks Tech Support to ensure the power requirements for your specific application do not exceed the available power. 6
7 TERM INIT 12C 12C-1 10/100 10/ Installing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the Media Converter Slide-in-Module(s) into the chassis. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module(s). NOTE: Media Converter Slide-in-Modules can be installed in any installation slot, in any order. To install the Media Converter Slide-in-Module into the CPSMC Slot chassis: 1. Remove the Media Converter Slide-in-Module protective plate from the installation slot by removing the one (1) screw that secures the plate to the front of the chassis. NOTE: If the Slide-in-Module requires two slots, remove the protective plates from two (2) adjacent installation slots. 2. Align the Media Converter Slide-in-Module with the chassis installation slot so that the panel fastener screw is at the left of the Media Converter Slide-in- Module. slide-in-modules SPD F C INPORT OUTPORT SPD F C Panel Fastener Screw 3. Carefully slide the Media Converter Slide-in-Module into the installation slot. NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against the back of the chassis. 4. Install the Media Converter Slide-in-Module by carefully rotating the attached panel fastener screw clockwise to secure the Media Converter Slide-in-Module to the chassis. 5. Repeat steps 1 through 4 for additional Media Converter Slide-in-Module(s). 7
8 TERM INIT 12C 12C-1 10/100 10/ Replacing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing Media Converter Slide-in-Module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module(s). NOTE: The Media Converter Slide-in-Modules are hot-swappable. To replace a Media Converter Slide-in-Module: 1. Remove the Media Converter Slide-in-Module to be replaced by loosening the one (1) screw that secures the Slide-in-Module to the CPSMC chassis front. Slide the Media Converter Slide-In-Module from the CPSMC chassis. 2. Align the replacement Media Converter Slide-in-Module with the chassis installation slot so that the panel fastener screw is to the left. INPORT OUTPORT SPD F C SPD F C slide-in-modules Panel Fastener Screw 3. Carefully slide the replacement Media Converter Slide-in-Module into the installation slot. NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against the back of the chassis. 4. Install the replacement Media Converter Slide-in-Module by carefully rotating the attached panel fastener screw clockwise to secure the Media Converter Slide-in-Module to the chassis. 8
9 2.2 Management Modules Optional network management is provided by SNMP software embedded in Transition Networks PointSystem Management Module(s) that can be installed in the CPSMC Slot chassis. Transition Networks provides two such modules: CPSMM-120 Single-Slot Master Management Module. CPSMM-200 Dual-Slot Master Management Module. Along with an additional expansion module: CPSMM-210 Single Slot Expansion Management Module Three Types of Managment Modules CPSMM-120 Single-Slot Master Managment Module The optional CPSMM-120 Single-Slot Master Managment Module can be installed to enable network managment of a single CPSMC Slot chassis. slide-in-modules Refer to the CPSMM-120 User Guide for more information on the CPSMM-120 Single-Slot Master Management Module. SERIAL CPSMM120 CPSMM-200 Dual-Slot Master Management Module The optional CPSMM-200 Dual-Slot Master Managment Module can also be installed in the CPSMC Slot chassis to enable network managment. This module has all of the features of the CPSMM-120 plus a pair of cascade ports, which allow multiple PointSystem chassis to be connected. See section 4.3 Cascade Option for details on connecting multiple chassis. INPORT OUTPORT TERM INIT 12C 12C-1 Note also that this module requires two adjacent slots in the CPSMC Slot chassis for installation. CPSMM200 Refer to the CPSMM-200/-210 User Guide for more information on the CPSMM-200 Dual-Slot Master Management Module. CPSMM-210 Single-Slot Expansion Management Module The CPSMM-210 is used with the CPSMM-200 to connect up to eight (8) PointSystem chassis into one managable stack. See section 4.3 Cascade Option for details. Refer to the CPSMM-200/-210 User Guide for more information on the CPSMM-210 Single-Slot Expansion Management Module. Pwr INIT TERM 12C-1 12C CPSMM210 9
10 2.2.2 Installing the Managment Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the Management Module(s) in the 8-Slot chassis. Failure to observe this caution could result in damage to, and subsequent failure of, the Management Module. Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) in the primary managed CPSMC Slot chassis. If several PointSystem chassis are to be connected in a cascade fashion (see section 4.3 Cascade Option): Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) into the primary managed CPSMC Slot chassis. Install one (1) Master Management Module (CPSMM-200) or one (1) Expansion Management Module (CPSMM-210) in any secondary managed CPSMC Slot chassis. slide-in-modules NOTE: Though the Management Module(s) can be installed in any PointSystem chassis slot, use of the left-most installation slot(s) for installing the Management Module(s) is recommended in order to keep the cascading cables separate from the network cables connected to the installed on Media Converter Slide-In-Modules. To install a Management Module: 1a. CPSMM-200 Dual-Slot Master Management Module: Remove two (2) Management Module protective plates from two (2) installation slots at the far-left position by removing the one (1) screw that secures each protective plate to the PointSystem chassis. 1b. CPSMM-120 Single-Slot Master Management Module OR CPSMM-210 Single-Slot Expansion Management Module: Remove one (1) Management Module protective plate from one (1) installation slot at the far-left position by removing the one (1) screw that secures the protective plate to the PointSystem chassis. 2. Align the Management Module with the PointSystem chassis installation slot so that the panel fastener screw is to the left of the Management Module. TERM INIT 12C 12C-1 INPORT OUTPORT Panel Fastener Screw 3. Carefully slide the Management Module into the installation slot, aligning the Management Module with the installation guides. NOTE: Ensure that Management Module is firmly seated against backplane. 4. Rotate the attached panel fastener screw clockwise to secure the Management Module to the PointSystem chassis. 10
11 2.2.3 Replacing the Mangement Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing Media Converter Slide-in-Module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the Management Module(s). NOTE: The Managment Modules are NOT hot-swappable. To replace a Managment Module: 1. Remove the Managment Module to be replaced by loosening the one (1) screw that secures the Managment Module to the CPSMC chassis front. Slide the Management Module from the CPSMC chassis. 2. Align the replacement Mangement Module with the installation slot so that the panel fastener screw is at the top. slide-in-modules TERM INIT 12C 12C-1 INPORT OUTPORT Panel Fastener Screw 3. Carefully slide the replacement Managment Module into the installation slot. NOTE: Ensure that the Managment Module is firmly seated against the back of the chassis. 4. Install the replacement Managment Module by carefully rotating the attached panel fastener screw clockwise to secure the Managment Module to the chassis. 11
12 TERM INIT 12C 12C-1 10/100 10/100 3 Powering the CPSMC The CPSMC chassis can be powered through an AC or DC Power Supply. An optional auxilliary power supply, with Instant Fail Over protections, is also available. NOTE: The CPSMC Slot chassis does not have an ON/OFF switch. Power up the chassis by connecting the power supply. Power-down the chassis by disconnecting power supply. WARNING: THE AC AND DC POWER SUPPLIES CONTAIN NO USER-SERVICA- BLE PARTS. DO NOT ATTEMPT TO SERVICE EITHER POWER SUPPLY. FAILURE TO OBSERVE THIS CAUTION COULD RESULT IN EQUIPMENT DAMAGE AND/OR PERSONAL INJURY OR DEATH. 3.1 Primary Power Supply NOTE: Contact Technical Support for any questions concerning power supply. The CPSMC includes an internal power supply, which is accessed through a power inlet on the front panel. The power cord is included. power supply To power the CPSMM Slot chassis through the Primary Power Supply: 1. Connect the female end of the power cord to the Power Inlet on the front panel of the chassis. 2. Plug the male end of the power cord into the correct voltage rack or wall socket. 3. Verify that the 8-Slot chassis is powered by observing the illuminated Power LEDs on the Slide-in-Modules and by the fan operation. Power Inlet SPD F C INPORT OUTPORT SPD F C Power Cord 12
13 3.2 Auxilliary Power Supply The CPSMC can also be supplied with auxilliary power through the Auxilliary Power Inlet, located on the back panel. The External Power Converter and additional power cord are sold separately. To power the CPSMM Slot chassis through the Auxilliary Power Supply: 1. Connect the female end of the External Power Converter to the Auxilliary Power Inlet on the back of the 8-Slot chassis. 2. Connect the female end of the power cord to the male end of the External Power Converter. 3. Plug the male end of the power cord into the correct voltage AC rack or wall socket. 4. Verify that the chassis is powered by observing the illuminated Power LEDs on the Slide-in-Modules and by the fan operation. Auxilliary Power Inlet power supply Power Cord External Power Converter 13
14 4 CPSMC Chassis 4.1 Installing the CPSMC Chassis The CPSMC can be installed in a standard 19-inch rack or on a table, shelf, or other stable surface Standard 19-inch Rack Installation NOTE: The maximum recommended ambient temperature (Tmra) for the 8-Slot chassis is 40 C. If the 8-Slot chassis is installed in a closed or mult-unit rack assembly, the operating ambient temperature of the the rack environment may be greater than room ambient. Consideration should be given to installing the 8-Slot chassis in an environment compatible with the Tmra. CAUTION: Installation of the chassis in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. The 8-Slot chassis is designed so that the installation brackets can be installed to align the chassis either flush against the front or back edge of the rack or recessed from the front or back edge of the rack. Flush Alignment at front Recessed Alignment at front Flush Alignment at back Recessed Alignment at back WARNING: SELECT MOUNTING BRACKET LOCATIONS ON THE CHASSIS THAT WILL KEEP THE CHASSIS BALANCED WHEN MOUNTED IN THE RACK. FAILURE TO OBSERVE THIS WARNING COULD ALLOW THE CHASSIS TO FALL, RESULT- ING IN EQUIPMENT DAMAGE AND/OR POSSIBLE INJURY TO PERSONNEL. chassis CAUTION: Consideration should be given to the connection of the chassis to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplates should be used when addressing this concern. CAUTION: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). 14
15 TERM TERM INIT 12C 12C-1 INPORT OUTPORT INIT 12C 12C-1 INPORT OUTPORT TERM INPORT INIT 12C 12C-1 OUTPORT F C F C F 10/100 C To install the CPSMC Slot chassis into a standard 19-inch rack: 1. Determine the preferred alignment of the 8-Slot chassis in the rack. NOTE: Installation bracket mounting screws are provided. Rackmount screws and clip nuts are NOT provided. 2. Locate six (6) installation bracket mounting screws (provided) for each chassis to be installed. WARNING: Mount the chassis evenly and securely onto the rack. Failure to observe this warning could allow the chassis to fall, resulting in equipment damage and/or possible injury to personnel. 3. Align the universal mounting bracket in the selected position against the side of the chassis so that the chassis installation holes are visible through the universal bracket installation holes. 4. Using a Phillips screwdriver, install the three (3) screws through the mounting bracket into the installation holes on side of the chassis. Step 4: SPD SPD F C 10/100 10/100 F C 10/ Repeat steps 3 and 4 for the second mounting bracket. 6. Locate four (4) screws (not provided) and optional clip-nuts (not provided) for each chassis to be installed. SPD SPD 7. Carefully align the chassis at a secure and level position between the 19-inch site rack mounting rails. 8. Install two (2) screws through the right bracket into the right mounting rail and two (2) screws through the left bracket into the left mounting rail, using the clip nuts to secure, if necessary. chassis Step 8: 10/100 F SPD C SPD 10/ Table-Top Installation The CPSMC slot chassis is shipped with four (4) rubber feet for optional installation on a table or other flat, stable surface in a well-ventilated area. If tabletop installation is desired, remove the rubber feet from the card and place one at each of the four corners on the bottom of the chassis. 15
16 TERM TERM TERM INIT 12C 12C-1 INIT 12C 12C-1 INIT 12C 12C-1 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/100 10/ Cascade Option The Management Module cascade option allows the network administrator to connect up to eight (8) CPSMC Slot chassis into one manageable stack, providing a single management source for up to 55 installed Media Converter devices. To create the cascade option, the CPSMM-200 Dual Slot Master Management Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot Expansion Management Module is installed in each subsequent chassis. The CPSMM-200 Management Module is installed in the first chassis in the series INPORT OUTPORT SPD F C SPD F C The CPSMM-210 Management Module is installed in each subsequent chassis Pwr INIT TERM 12C-1 12C SPD F C SPD F C Pwr INIT TERM 12C-1 12C SPD F C SPD F C Pwr INIT TERM 12C-1 12C SPD F C SPD F C The CPSMM-200 Management Module is installed in the first chassis in the series An alternative setup involves installing two CPSMC-200 Dual-Slot Master Management Modules into two adjacent chassis chassis for redundant management. INPORT OUTPORT SPD F C SPD F C chassis Another CPSMM-200 Managment Module is installed in the next chassis as a backup INPORT OUTPORT SPD F C SPD F C 16
17 TERM INIT 12C 12C-1 10/100 10/100 To cascade two or more CPSMC Slot chassis: 1. Locate one (1) Transition Networks CPSMC Management Module cascade cable (with RJ-45 connectors installed at both ends) for each set of two (2) chassis to be cascaded. NOTE: Transition Networks Management Module cascade cables are one (1) meter long. Ensure that the chassis are installed within one (1) meter of each other. 2. At the first chassis in the series: Plug the RJ-45 connector at one end of the cascade cable into the Management Module s RJ-45 port labeled OUTPUT. 3. At the next chassis in the series: Plug the RJ-45 connector at the other end of the cascade cable into the Management Module s RJ-45 port labeled INPUT. 4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the cascade cable into the Management Module s RJ-45 port labeled OUTPUT. 5. At the next chassis in the series: Plug the RJ-45 connector at the other end of the cascade cable into the Management Module s RJ-45 port labeled INPUT. 6. Repeat steps 4 and 5 until all chassis have been connected. 4.3 Connecting the Slide-in-Modules to the Network Once the CPSMC chassis has been installed, the Media Converter Slidein-Modules may be connected to the network. CAUTION: Connect input/output network cables ONLY to Media Converter Slide- In-Module connectors within the same network protocol (such as Ethernet-to- Ethernet, Fast Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this caution will cause data transfer to fail. Refer to User s Guides included with the Media Converter Slide-In-Modules for cabling specifications and instructions. chassis SPD F C INPORT OUTPORT SPD F C Check the individual User's Guides for specific information on how to connect each Slide-in-Module to the network. 17
18 TERM INIT 12C 12C-1 10/100 10/ Operation Daily operation of the CPSMC Slot chassis requires no network administrator activity except for the occasional monitoring of the status LED indicators on the installed Media Converter Slide-In-Modules. Each Media Converter Slide-in-Module and each Management Slide-in-Module has one or more LED indicators to help monitor the CPSMC PointSystem chassis network. Refer to the User s Guide included with each Transition Networks Slide-in-Module to interpret the LED indicators on the Managment and Media Converter modules. LED Indicators on the Management Module and Slide-in-Modules SPD F C INPORT OUTPORT SPD F C chassis 18
19 TERM INIT 12C 12C-1 10/100 10/100 5 SNMP Agent in the Management Module Both Management Modules (CPSMM-120 and (CPSMM-200) have an SNMP (Simple Network Managment Protocol) Agent installed in the module that allows remote managment of networked devices. The SNMP agent includes the Transition Networks PointSystem Command Line Interface (CLI) and an embedded Telnet server. These tools allow the network adminsitrator to configure and manage the CPSMC Slot from an attached terminal or from a remote, networked computer. In addition, Transition Networks FocalPoint software can be installed in the networked computer to provide a graphical user interface to monitor the Conversion Center. 5.1 SNMP Hardware Connections The SNMP software can be accessed either through the Management Module s DB- 9 serial port or through the RJ-45 Ethernet port. RJ-45 Ethernet Port INPORT OUTPORT TERM INIT 12C 12C-1 Serial Port SERIAL CPSMM200 CPSMM-200 CPSMM120 CPSMM-120 Serial Port The serial port allows the network administrator to configure and manage the CPSMC Slot chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator. Use a null modem cable to attach a terminal to the serial port on the Management Module as shown. Attached terminal or terminal emulator connected to the serial port via null modem cable. SNMP SPD F C INPORT OUTPORT SPD F C Tech Support: M-F 7am-6pm CST (GMT -6:00) International:
20 TERM INIT 12C 12C-1 10/100 10/100 RJ-45 Ethernet Port The RJ-45 Ethernet Port allows the network administrator to manage the CPSMC Slot chassis via a remote Network Management Station (NMS) in one of two ways: 1. Using the Transition Networks FocalPoint graphical user interface. 2. Using a remote Telnet connection. Use an RJ-45 network cable to attach a terminal (via a network hub or switch) to the RJ-45 Ethernet port on the Management Module as shown. SPD F C INPORT OUTPORT SPD F C Network hub or switch connected to the RJ-45 Ethernet port. Remote Telnet connection OR Remote NMS with an SNMP application NOTE: To manage the PointSystem chassis via a remote NMS, both the RJ-45 Ethernet port and the NMS must be connected to a network with Internet accesibility. 5.2 SNMP Software The SNMP software is described in a separate manual available from Transition Networks. SNMP Tech Support: M-F 7am-6pm CST (GMT -6:00) International:
21 6 Fault Isolation and Correction 1. Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated; AND/OR are the fans operating? YES The chassis is receiving power. Proceed to the next step. NO Ensure all power supply cables for proper connection. Ensure the AC receptacle on the wall is supplying power. If the fuse for the AC receptacle on the wall blows repeatedly, have the AC receptacle inspected by a qualified electrician. Contact Tech Support: , Int l: Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated; but are the fans NOT operating? YES The chassis is receiving power. Proceed to the next step. NO Contact Tech Support: , Int l: For the Management Modules (CPSMM120, CPSMM200, CPSMM210), are ANY of the POWER LEDs NOT illuminated? NO All Managment Modules are receiving power. Proceed to the next step. YES For those Management Modules where the POWER LED is NOT illuminated: Ensure the Management Module is firmly seated in the slot. Press the button on the Managment Module. Contact Tech Support: , Int l: For the remaining Slide-in-Modules, are ANY of the POWER LEDs NOT illuminated? NO All Slide-in-Modules are receiving power. Proceed to the next step. YES For those Slide-in-Modules where the POWER LED is NOT illuminated: Ensure the Slide-in-Module is firmly seated in the slot. Contact Tech Support: , Int l: To determine if a fault is due to a software problem, consult the Fault Isolation and Correction section of the SNMP software manual available from Transition Networks. 6. To determine if a fault is due to an individual Managment Module or Slide-in- Module, consult the Fault Isolation and Correction section of the User Guide for that particular Module. 7. If none of the solutions listed in this section resolves the problem, contact Technical Support: , International: troubleshooting 21
22 Technical Specifications For use with Transition Networks Model CPSMC or equivalent. Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture. Dimensions Shipping Weight Power Input 17 x 10.4 x 1.8 inches (432 x 264 x 46 mm) 8 lbs. (3.6 kg) VAC, 50/60Hz, 18-72VDC Power Consumption 60 Watts* *Refer to the power consumption data for each individual Media Converter Slide-in-Module (provided in the User s Guide shipped with the Media Converter) to determine optimum site configuration. MTBF (Mean Time Before Failure) MIL217F2 V5.0 (hrs) Bellcore7 V5.0 (hrs) without fans 43, ,896 with three (3) fans 22,972 61,715 Environment Tmra*: 0 to 40 C (32 to 104 F ) Storage Temperature: -40 to 80 C (-40 to 176 F ) Humidity 5 to 95%, non condensing Altitude 0 to 10,000 feet *Manufacturer s rated ambient temperature. Refer to the power consumption data for EACH model Media Converter Slide-in-Module (provided in User s Guide shipped with Media Converter Slide-in- Module) to determine optimum site configuration. Compliance Warranty EN Class A; EN 55024; FCC Class A; UL Listed, CE Mark Lifetime CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly With Optical Instruments. CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. DECLARATION OF CONFORMITY Name of Mfg: Transition Networks 6475 City West Parkway, Minneapolis MN USA Model: PointSystem Chassis Part Number: CPSMC , CPSMC Regulation: EMC Directive 89/336/EEC Purpose: To declare that the PointSystem Chassis to which this declaration refers is in conformity with the following standards. EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; UL 1950; 21 CFR subpart J I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Stephen Anderson, Vice-President of Engineering _April 1, 2003 Date Tech Support: M-F 7am-6pm CST (GMT -6:00) International:
23 Cable Specifications Null Modem Cable The Null Modem Cable is used for connecting a terminal or terminal emulator to the Management Module s connecdtor to access the command-line interface. The table below shows the pin assignments for the DB9 cable. Function Mnemonic Pin Carrier Detect CD 1 Receive Data D 2 Transmit Data D 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8 RJ-45 Cable Category 5: Gauge: Attenuation: Maximum Cable Distance: 24 to 22 AWG 22.0 db 100 MHz 100 meters Straight-Through OR Crossover cable may be used. Shielded Twisted-Pair(STP) OR Unshielded Twisted-Pair(UTP) may be used. All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet network. Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.) Do not use flat or silver satin wire. Tech Support: M-F 7am-6pm CST (GMT -6:00) International:
24 Contact Us Technical Support Technical support is avialable 7:00 AM - 6:00 PM CST (GMT -6:00) United States: International: Transition Now Chat live wia the Web with a Transition Networks Technical Support Specialist. Log onto and click the Transition Now link. Web-Based Seminars Transition Networks provides seminars per month via live web-based training. Log onto and click the Learning Center link. Ask a question anytime by sending an message to our technical support staff. [email protected] Address Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: toll free: fax:
25 Warranty Limited Lifetime Warranty Effective for Products Shipped May 1, 1999 and After. Every Transition Networks' labeled product purchased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. This warranty covers the original user only and is not transferable. This warranty does not cover damage from accident, acts of God, neglect, contamination, misuse or abnormal conditions of operation or handling, including overvoltage failures caused by use outside of the product's specified rating, or normal wear and tear of mechanical components. If the user is unsure about the proper means of installing or using the equipment, contact Transition Networks' free technical support services. To establish original ownership and provide date of purchase, please complete and return the registration card accompanying the product or register the product online on our product registration page. Transition Networks will, at its option: Repair the defective product to functional specification at no charge, Replace the product with an equivalent functional product, or Refund the purchase price of a defective product. To return a defective product for warranty coverage, contact Transition Networks' technical support department for a return authorization number. Transition's technical support department can be reached through any of the following means: During regular business hours Monday-Friday, 7 AM 6 PM CST (- 6:00 GMT), Contact Tech Support via: tel x 200 or x 200 fax [email protected] live web chat: Transition NOW Any Other Time: voice mail x 579 or x 579 All messages will be answered within one hour. Send the defective product postage and insurance prepaid to the following address: CSI Material Management Center c/o Transition Networks 508 Industrial Drive Waconia, MN USA Attn: RETURNS DEPT: CRA/RMA # Failure to properly protect the product during shipping may void this warranty. The return authorization number must be written on the outside of the carton to ensure its acceptance. We cannot accept delivery of any equipment that is sent to us without a CRA or RMA number. The customer must pay for the non-compliant product(s) return transportation costs to Transition Networks for evaluation of said product(s) for repair or replacement. Transition Networks will pay for the shipping of the repaired or replaced in-warran- 25
26 ty product(s) back to the customer (any and all customs charges, tariffs, or/and taxes are the customer's responsibility). Before making any non-warranty repair, Transition Networks requires a $ charge plus actual shipping costs to and from the customer. If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair. If no authorization is obtained, or the product is deemed not repairable, Transition Networks will retain the $ service charge and return the product to the customer not repaired. Non-warranted products that are repaired by Transition Networks for a fee will carry a 180-day limited warranty. All warranty claims are subject to the restrictions and conventions set forth by this document. Transition Networks reserves the right to charge for all testing and shipping incurred, if after testing, a return is classified as "No Problem Found." THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. Transition NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHO- RIZED TO EXTEND ANY DIFFERENT WARRANTY ON TRANSITION NETWORKS' BEHALF. 26
10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter
12 COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital
Transition Networks CPSMC19xx-100 19-Slot PointSystem Chassis. User s Guide (revision C) CPSMC1900-100 CPSMC1910-100
Transition Networks CPSMC19xx-1 19-Slot PointSystem Chassis User s Guide (revision C) CPSMC19-1 CPSMC191-1 Compliance Information UL Listed C-UL Listed (Canada) CISPR22/EN5522 Class A + EN5524 CE Mark
T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE
COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55204 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital
T1/E1 Copper-to-Fiber Slide-In-Module Media Converters USER S GUIDE COMPLIANCE INFORMATION C/T1E1-CF-01
COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide
POTS 2-Wire to Fiber Converter TE160A, TE161A, TE162A TE163A, TE164A, TE165A User s Guide The Black Box POTS 2-Wire to Fiber Converter (P/N TE16xA) connects centraloffice voice-grade signals to distant
T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE COMPLIANCE INFORMATION. SSDTF10xx*-100
COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital
User Guide. Introduction. Contents. Models / Part Numbers. 100-Base-FX Network Interface Cards (NICs)
User Guide 100-Base-FX Network Interface Cards (NICs) Introduction Transition Networks N-FX-xx-03 PCI 100FX NICs provide a 100Base-FX fiber port and delivers low cost, fiber optic connectivity to the desktop
Model 0400 (800) 260-1312 MODEL 0400 ETHERNET POCKET HUB SPECIFICATIONS (E-TBT-HB-0400) Standards. Physical
MODEL 000 ETHERNET POCKET HUB SPECIFICATIONS Standards IEEE 802.2, 802. Physical Dimensions.80" X 2.77" X 0.95" (122mm x 70mm x 2mm) Power Supply Adapter AC Input: PN Requirement Location 518 120 volts,
Part Number Port One - Copper Port Two - Duplex Fiber-Optic. 2 km (1.2 miles)* SCSCF3013-110 75 ohm coax (BNC) SC, 1300 nm multimode,
User s Guide SCSCF30xx-11x Standalone Device DS3, T3/E3, or STS-1 Coax (BNC) to Fiber Transition Networks SCSCF30xx-11x series stand-alone encode and decode DS3, E3/T3, or STS-1 coax copper signals over
Power Over Ethernet Adapters POE101
Power Over Ethernet Adapters POE101 Installation Guide Introduction NETGEAR POE101 Power over Ethernet adapters are designed to supply operational power to devices through an Ethernet cable. These adapters
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
FIBER OPTIC A/B/C SWITCH (Latching)
JANUARY 2008 Model# SW1004A FIBER OPTIC A/B/C SWITCH (Latching) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days
SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)
SEPTEMBER 2008 Model# SW1035A Model# SW1036A SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING) CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical
4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide
4-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS104 Installation Guide 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR E-mail: [email protected] www.netgear.com Technical
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
WARNING CANADIAN D.O.C. WARNING
Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
100 - SERIES NETWORK SWITCHES QUICK START GUIDE
100 - SERIES NETWORK SWITCHES QUICK START GUIDE Unmanaged IT Rack Network Switches FCC Warning This device has been tested and found to comply with limits for a Class A digital device, pursuant to Part
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
Technical Support. Support Information
Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM. ProSafe 24 Port Gigabit Switch Installation Guide
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM ProSafe 24 Port Gigabit Switch Installation Guide Full_IG.book Page 2 Monday, January 9, 2012 6:11 PM 2011 NETGEAR, Inc. All rights reserved. No part
About the HotWire 7900 10-Slot Standalone Shelf
TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed
USB Mini Print Server PS121. Installation Guide
USB Mini Print Server PS121 Installation Guide Introduction Thank you for purchasing a NETGEAR PS121 USB Mini Print Server. With this print server you can share your printer with all the computers in your
USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide
16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
HP R12000 and R18000 DirectFlow UPS User Guide
HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use
DVI DA2 and DVI DA 4 User Guide
DVI DA2 and DVI DA 4 User Guide This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Amplifiers. Unless stated otherwise, distribution amplifier or the unit
Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide
Start Here Congratulations on your purchase of the NETGEAR Model EN104, Model EN108, or Model EN116 Ethernet hub. The hubs deliver standards-based, plugand-play networking solutions for small businesses,
Zebra RW 420 Mobile Battery Eliminator Kits
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA Zebra RW 420 Mobile Battery Eliminator Kits Installation Instructions September, 2010 RW 420 Mobile Battery Eliminator
Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap
Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap 800-0150-001 Rev. F PUBTPCU3ZDU 8/10 Gig Zero Delay Tap PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Tap you agree
LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide
LFH4-M/LFH8-M Mini Fast Hubs Installation Guide Table of Contents CHAPTER 1. Introduction 1.1 Product Introduction............................... 2 1.2 Features.........................................
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide
M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU. 800-0045-001 Doc. PUBTPACUU Rev. 1, 12/08. In-Line
Installation Guide for 10/100 to Triple-speed Port Aggregator Model TPA-CU In-Line 800-0045-001 Doc. PUBTPACUU Rev. 1, 12/08 Contents Introduction.....................................................
Perle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
Installation & User Manual
Messager USB Installation & User Manual Note: All units support MP3 playback of up to 128Kbps @ 48KHz. Units with serial numbers starting with 15 or above will support the addition of WAV playback done
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
HP 2530 8-Port Switches Quick Setup Guide
HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
MACTek Corporation. USB HART Interface. Users Manual
MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials
User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch
User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch Rev: 1.1.0 7106503251 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark
Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.
About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown
The power module is Feature Number 8800-F2-901.
Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two
Wireless Optical Travel Mouse
Wireless Optical Travel Mouse User s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS DEVICE. Table of Contents FCC Statement Page 3 Introduction.. Page 6 Package Contents.. Page
User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October
Universal Laptop Charger
USER GUIDE Universal Laptop Charger NS-PWLC591/NS-PWLC591-C Before using your new product, please read these instructions to prevent any damage. NS-PWLC591/NS-PWLC591-C Insignia NS-PWLC591/ NS-PWLC591-C
Refer installation of power supplies to qualified service personnel.
AC Power Supply For 5-Slot Housing and 9000 Series Access Carrier Installation Instructions Document Number 9000-A2-GN17-50 August 2000 Before You Begin Both the 5-slot housing and the 9000 Series Access
Model PS-4001 Power Supply User Instructions
Model PS-4001 Power Supply User Instructions 9350-7710-000 Rev E 9/2009 PROPRIETARY NOTICE The product information and design disclosed herein were originated by and are the property of Bosch Security
User Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0 CONNECTING
Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide. 613-001352 Rev. A
Gigabit eco-friendly Ethernet Switch AT-GS900/8 Installation Guide 613-001352 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior
FriendlyNET FX4000 4-Slot Modular Switch. User s Manual
FriendlyNET FX4000 4-Slot Modular Switch User s Manual 2 Asanté FriendlyNET FX4000 Table of Contents Chapter 1. Introduction 5 Key Features 5 Package Contents 5 Chapter 2. Product Overview 7 Front Panel
AI120 AIswitch Series 120 Chassis
AI120 AIswitch Series 120 Chassis Guide INSTALLATION GUIDE Westell Technologies Part # 030-300715 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management
About the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual
High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
Powerware Relay-Serial Card User s Guide
Powerware Relay-Serial Card User s Guide Special Symbols The following are examples of symbols used on the UPS and accessories to alert you to important information: This symbol indicates that you should
IP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
USB Rover 2850. 2-port USB 1.1 40m Cat 5 Extender. User Guide
USB Rover 2850 2-port USB 1.1 40m Cat 5 Extender User Guide Thank you for purchasing the USB Rover 2850, 2-port USB 1.1 40 m (131 ft) Cat 5 Extender Please read this guide thoroughly. FCC Radio Frequency
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
FCC COMPLIANCE STATEMENT
MEDIA CONVERTER Fiber to UTP Ethernet Media Converter ET90110SC ET90110ST Instruction Guide * Actual product may vary from photo Revised: December 6, 2002 The Professionals Source For Hard-to-Find Computer
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
AT-9400Ts Stack Installation Guide
AT-9400Ts Series Gigabit Ethernet Switches Basic Layer 3 AT-9424Ts AT-9424Ts/XP AT-9448Ts/XP AT-9400Ts Stack Installation Guide 613-001191 Rev. B Copyright 2009 Allied Telesis, Inc. All rights reserved.
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company
USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
User Guide TL-SG1016/ TL-SG1024 16/24-port Gigabit Ethernet Switch
User Guide TL-SG1016/ TL-SG1024 16/24-port Gigabit Ethernet Switch Rev:2.0.0 7106500823 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: [email protected] www.olsontech.com
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions
TM 5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions Document Number 9000-A2-GN17-30 August 1998 Before You Begin Both the 5-slot housing and the FrameSaver
ES-3305P V2 / ES-3308P V2. Quick Installation Guide. 09-2013 / v1.0
ES-3305P V2 / ES-3308P V2 Quick Installation Guide 09-2013 / v1.0 1 COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances
This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved