Areamaster LED Flood/High Bay Luminaires 250 W, 400 W, 750 W HID Light Level Equivalent

Similar documents
HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Linear Luminaire with LED Series EXLUX 6402/2

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

8146/5 Series Breaker Panelboards

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

2.12. page Products for Explosion hazardous Environment

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Terminal Box. Specifications TNCN

DuroSite TM High Bay Lighting

Floodlight Range Installation Guide

Terminal Boxes Series 8146

SEISMIC VELOCITY TRANSDUCER T1-40

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

Explosion proof enclosures

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

STB Series Enclosures

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Control and Distribution Boxes made of Stainless Steel Series 8150

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Data. Dimensions

Flow switches Series AD/VH

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Series 8146/5-V37 and Series 8150/5-V37

B-Series Temperature Switches

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

Dialight LED Lighting Fixture Catalog. for Indoor and Outdoor Industrial and Hazardous Locations

Power Supplies 3. SDN-P DIN Rail Series

GUE, GUB Junction Boxes

Plug and Socket Devices CES 63 A Series 8579

Invue ECM/EMM EPIC MEDIUM W

CompactLogix Power Supplies Specifications

Technical Data. Dimensions

Champ VMV Series. 3,000 to 25,000 lumen LED high bay luminaires. LED luminaires for hazardous areas

C2D LowBay: All the power, none of the bulk. C2D Advantage

Explosion-Proof Electric Unit Heaters

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Technical Information RIA14

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

4 Posiflow Proportional Solenoid Valves

IPS HIGH-BAY / LOW-BAY LIGHTING

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

DuroSite LED End-to-End Linear Fixture - NSF. for Indoor and Outdoor Industrial Applications

TITAN TITAN THE HIGH BAY SERIES

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

ALARI LED PARKING, ROADWAY & AREA LIGHTING

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EDS / EFS Series Control Stations

B-Series Switches Pressure, Differential Pressure & Hydraulic

Differential-Hall-Effect based Sensors Series A5S Overview

A good connection. International approvals.

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

1756 ControlLogix Chassis Specifications

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Compact pressure switch Flameproof enclosure Ex d Model PCA

Mini USB and USB 2.0-IP67 Connector System

Inductive sensor NI10-M18-Y1X-H1141

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

EDS / EFS Series Control Stations

SITRANS F flowmeters SITRANS F M

Plug and Socket Devices SolConeX 16 A Series 8570

Worcester DS/DM Series UltraSwitch Switch box

AMERBRITE UNDERWATER WHITE LED POOL LAMP

LED High Bay Light 100W

Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Product Line DUST. The family of hermetic luminaires

Instructions for Safe Use

Abtech Custom Solutions

Plastic tube flowmeters Series PT/PS

Operating Instructions

FLB Series Circuit Breakers and Enclosures

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

gesis IP + Heavy Duty Class I, Zone 2

Electronic, Digital and Mechanical Vibration Switches

Transcription:

/67 Applications Typical applications include: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Food processing plants Storage areas Waste and sewage treatment Parking garages Other areas where water, dirt and rough usage are a problem Features Compact in size, attractively styled contemporary design, rugged and dependable. Easy to install and service. One-piece housing. One-piece lens in hinged cover. Secured by four M6 captive stainless steel slotted hex-head bolts. Thermal shock- and impact-resistant glass lens standard. Diffused polycarbonate lens available as an option. Heavy duty, high temperature silicone rubber gasket, mechanically secured. Universal design for flood and high bay mounting. Floodlight Mounting: Yoke mount, zinc plated steel yoke with architectural bronze polyester finish. High Bay Mounting: (1) Conduit entry on back of luminaire with locking set screw. Rotate yoke up or remove. Chain Mounting: Mounts via eyebolts threaded into the corners of the fixture. Available with chain mounting, or as an accessory. Rotate yoke up or remove. Cool operating temperatures translate into long luminaire life. versions available with a total of three (3) 3/4" NPT entries with integral bushings. ATEX version provided with one (1) 3/4" NPT/M20 adapter and two (2) close up plugs. Two (2) 3/4" NPT aluminum close up plugs provided. Electrical: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz.; 250 Vdc available on AMLED67YBC and AMLED77YBC. 220-240 Vac, 50/60 Hz. Terminal block (screw type for secure connection) can accept UL/CSA 24-10AWG and IEC 0.2-4 mm 2. Standard Materials Housing and lens door: copperfree (4/10 of 1% max.) aluminum Gasket: silicone rubber Reflector: metallized high reflectance finish Yoke mount: zinc plated steel Bolts: stainless steel Close up plugs: (2) aluminum provided Standard Finishes Housing, lens cover and yoke mount: architectural bronze polyester Floodlight High Bay Certifications and Compliances UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 UL Listed: E10794 CSA Standards: C22.2 No. 250.0, C22.2 No. 137 Certifications and Compliances Gas Conforming to ATEX 94/9/EC: ATEX Protection: Ex na IIC T Rating: T4 (Ta < +40 ºC) (Ta < +104 ºF) Ambient Temperature: -25 ºC < Ta < 40 ºC (-13 ºF < Ta < 104 ºF) ATEX Certificate: DEMKO 12 ATEX 1225382 Index of Protection: CE Declaration of Conformity: 12-01 Ex Standards: EN / IEC 60079-0 2009; 60079-15:2010 Product Standards: EN / IEC 60598-1; 60598-2-22 EMC Standards: EN / IEC 55015; 61547 Other Standards: EN / IEC 60529; 1991/A1 2000 (IP) LIGHTING: ENCLOSED AND GASKETED FLOODLIGHT 1149 Lighting

/67 Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog ing Guide AMLED 7 7 Y BU1 FN AMLED: Areamaster LED Series Certified HID Light Level Equivalent: 6-250 Watt 7-400 Watt 8-750 Watt Light Pattern Mounting: Y - Yoke Mount C - Chain Mount Voltage: BU1-120-277 Vac, 50/60 Hz BH - 347-480 Vac, 50/60 Hz BC - 250 Vdc BK - 220-240 Vac, 50/60 Hz Options: FN - Fuse for BU1 or BH Voltages D - Diffused Polycarbonate Lens Not available for use on the 750 Watt equivalent. 220-240 Vac, 50/60 Hz voltage is only available for use on the 400 Watt equivalent fixture. Canadian Electrical Code does NOT allow fusing in hazardous locations V. Fuse not CEC rated. 1150

/67 Technical Data Catalog Lamp Line Voltage Type Ambient Temperature C ( F) Supply Wire Temperature C ( F) Class I, Division 2 Gas Dust Gas Groups ExnA IIC AExnA IIC Class II, Division 1 Groups E,F,G ExII3G ExnA Subdivision 40 (104) 75 (167) T4 A,B,C,D T4 AMLED67YBU1 120-277 Vac LED 55 (131) 90 (194) T3C A,B,C,D T3 65 (149) 90 (194) T3C A,B,C,D T3 AMLED67YBH 347-480 Vac LED 40 (104) 75 (167) T4 A,B,C,D T4 AMLED67YBC 250 Vdc LED 40 (104) 75 (167) T4A A,B,C,D T4 40 (104) 75 (167) T4 A,B,C,D T4 AMLED77YBU1 120-277 Vac LED 55 (131) 90 (194) T3C A,B,C,D T3 65 (149) 90 (194) T3C A,B,C,D T3 AMLED77YBH 347-480 Vac LED 40 (104) 75 (167) T4 A,B,C,D T4 AMLED77YBK 220-240 Vac LED 40 (104) 60 (140) T4 A,B,C,D T4 T4 IIC AMLED77YBC 250 Vdc LED 40 (104) 75 (167) T4A A,B,C,D T4 AMLED87YBU1 120-277 Vac LED 40 (104) 75 (167) T3C A,B,C,D T3 55 (131) 90 (194) T3A A,B,C,D T3 T s Represent the Maximum Internal Temperature or Maximum Surface Temperature T ( C) ( F) T ( C) ( F) T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 351-450 664-842 326-350 619-662 301-325 574-617 281-300 538-572 261-280 502-536 231-260 448-500 216-230 421-446 201-215 394-419 181-200 358-392 T1 T2 T3 T4 T5 T6 301-450 201-300 136-200 101-135 86-100 85 547-842 394-572 277-392 214-275 166-180 331-356 161-165 322-329 136-160 277-320 121-135 250-275 101-120 214-248 86-100 187-12 187-212 85 185 185 LIGHTING: ENCLOSED AND GASKETED FLOODLIGHT T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC. T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and Class I, Zone 2 as designated by the NEC or Zone 2 (Gas) and 22 (Dust) locations as designated by the IEC. 1151 Lighting

/67 Electrical Specifications Flood Mount Catalog Voltage Frequency (Hz) Watts Input Power (Nom.) Input Amps (Max.) Total Harmonic Distortion Power Factor AMLED67YBU1 120-277 Vac 50/60 76/74 0.64-0.32 0.5 > 0.98 AMLED67YBH 347-480 Vac 50/60 76/76 0.22-0.16 0.5 > 0.96 AMLED67YBC 250 Vdc 76 0.30 0.5 > 0.98 AMLED77YBU1 120-277 Vac 50/60 125/121 1.10 -.047 0.5 > 0.98 AMLED77YBH 347-480 Vac 50/60 120/119 0.35-0.25 0.5 > 0.96 AMLED77YBK 220-240 Vac 50/60 117 0.53-0.48 0.5 > 0.98 AMLED77YBC 250 Vdc 118 0.47 0.5 > 0.98 AMLED87YBU1 120-277 Vac 50/60 174/169 1.60-0.70 0.5 > 0.98 Line Voltage Catalog Fixture is not certified. 1152 120-277 Vac, 50/60 Hz AMLED67YBU1 120-277 Vac, 50/60 Hz AMLED77YBU1 120-277 Vac, 50/60 Hz AMLED87YBU1 347-480 Vac, 50/60 Hz AMLED67YBH 347-480 Vac, 50/60 Hz AMLED77YBH 250 Vdc AMLED77YBC 250 Vdc AMLED67YBC 220-240 Vac, 50/60 Hz AMLED77YBK

Dimensions in Millimeters (Inches) 388.6 mm (15.30 in) Floodlight 93.9 mm (3.70 in) 1/4-20 U.N.C. (4) corner 358.1 mm (14.10 in) 4645.2 mm 2 (7.20 in 2 ) Conduit Entry (Pendant Mount) 391.2 mm (15.40 in) (4) Yoke Bolts 57.2 mm (2.25 in) Conduit Entry 44.45 mm (1.75") 88.9 mm (3.50 in) Yoke 3.64 Turning Radius 180 Rotation (3) Mounting Holes 14 mm (0.56 in) Dia. Set Screw 144.78 mm (5.70 in) 122.7 mm (4.83 in) 88.9 mm (3.50 in) (3) hubs for 3/4" NPT Conduit 3/4" to M20 reducer bushing High Bay Pendant Mount Recommended Minimum Mounting Distance 304.8 mm (12 in) 3/4" NPT/M20 adapter supplied for ATEX version. Ceiling Juction Box Set Screw Rotate Yoke Up or Remove 152.4 mm (6 in) 1154