About us j a c o b - t h e s p e c i a l i s t f o r c a b l e g l a n d s a n d m e a s u r i n g t e c h n o l o g y The success story begins in 9. Wilhelm Jacob founds a small family business in Stuttgart, which turns into a successful industrial company in the south of Germany. Since those days, the main focus has always been on the production of high quality products for industrial customers and electro wholesalers. Over the years Jacob developed from the original small business to a branch leader. Our products are being used worldwide in the electro technical industry, for panel building, machine building or at your nearby electro wholesaler. Jacob is not only one of the leading manufacturers of cable glands but also a specialist in measuring technology and individual solutions for specific applications. Flexibility and velocity is important for the satisfaction of our customers. We take care that our orders are being delivered quickly and punctually. Our new logistic and production centre in Kernen built in the year 009 enables us to give the best delivery service to our customers. This is important to us. Investment in modern production technology is a must at Jacob for the development of our company and for continuous innovation. Our products are part of complex machinery and plant equipment and though small nevertheless important for the function of the equipment. Therefore our goal is 00% customer satisfaction. Jacob is your competent partner offering extensive customer service and support with a background of more than 85 years experience in product development and production. Together with our partners and customers we develop high quality solutions for their applications. Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Strasse 794 Kernen Fon 075 40-0 Fax 075 40-49 email: jacob@jacob-gmbh.de
Optical s Jacob Typ LO the applications The optical sensors are suitable to use in high pressure applications for level detection of liquids in Tanks, containers, vessels, Heating- climate- and cooling Installations, Refrigeration compressors and Engines. important characteristics Available in plastics and stainless steel Setting of sensitivity by factory adjustment Application with high pressure ranges max. 0...40 bar (plastic), max. 40...60 bar (stainless steel) The body material is glass-fiber reinforced polysulfone (PSU) or stainless steel with sensor dome of glass Transistor exit for the direct connection to a SPC Time delay can be adjusted over a SPC or optionally over the intgrated timer ex factory LED displays for operating and switching status (Type LO 4 + LO 44) Simple operational principle for a large application scope No moving parts Small installation dimensions, installation position arbitrary The PSU type is FDA conformal, applicable in the food industry Available with an 4-0 ma temperature output signal field of applications Mechanical Engineering Chemical industry Pharmaceutical industry Energy industry Food and beverage industry Water economy the measuring principle The optical sensors work with infrared ray emitter and an optical receiver. In air (liquid not present), all the light is reflected - internally - by the dome and then redirected to the receiver. When the liquid reaches the sensor dome, a big amount of the light emitted is lost in the liquid and the sensor senses its presence. The switching function is alternatively selectable as NC or NO contacts with liquid contact. The delay time for the switching signal can be adjusted over a SPC, or optionally by an integrated timer, ex works preset. Receiver Emitter By the dome reflected LED-Light Receiver Emitter LED-Light is adsorbed by the fluid Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Straße 794 Kernen Fon 075 40-0 Fax 075 40-49 E-Mail: jacob@jacob-gmbh.de
Optical infrared sensors from Jacob Type LO xx Body LO, LO 4 LO 4, LO 44 polysulfone glas-fiber reinforced polysulfone glas-fiber reinforced Cable PVC PVC Nut Nylon 6.6 ---- LED ---- Green / Red Torque Tighten 5 Nm 5 Nm Weight g 40 50 Protection grade IP54 Repeatability ± mm Output Type NPN open collector, PNP at -8 VDC Version Special design 4 VAC, AC-Output or NPN Electronic Protections reverse polarity, output short circuits Scope of supply meter PVC-cable, special lengths are possible on request Type Processconnection Function Output Power supply Output current (depending on Temperature range) LO Mx NO in air NPN open collector PN max. Temperature range -8 VDC max. 00mA 0 bar 0 C to +60 C LO 4 Mx NC in air PNP -8 VDC max. 00mA 0 bar 0 C to +60 C LO 4 G /8 NO in air NPN open collector -8 VDC max. 00mA 40 bar -40 C to +85 C* LO 44 G /8 NC in air PNP -8 VDC max. 00mA 40 bar -40 C to +85 C* * Temperature range by using in water is 0 C to 60 C. ~ AC OUT ~ = Brown = Black = Blue + + NPN OUT - PNP OUT - Type A L L SW SW H Da LO /4 Mx 6,5 7,0 9 5 6 0,5 LO 4/44 G /8 5 0 -- 47,5 4 Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Straße 794 Kernen Fon 075 40-0 Fax 075 40-49 E-Mail: jacob@jacob-gmbh.de
Optical infrared sensors from Jacob Type LO xx Body.405 (AISI 0) Dome Cable Torque Tighten Glass PVC 5 Nm Weight g 00 Protection grade Repeatability Output Type Special design Electronic Protections Scope of supply IP54 ± mm NPN open collector, PNP at -8 VDC Version 4 VAC, AC-Output or NPN reverse polarity, output short-cuicuits meter PVC-cable, special lengths are possible on request or with M, 5-pole Industrial Plug (IP67) Type LO G /" LO 4 ½" NPT LO 6 G /" LO 8 ½" NPT Function Output Power supply NO in air LO G / NO in air NPN open collector Output current (depending on Temperature range) PN max. Temperature range -8 VDC max. 00mA 60 bar -40 C to +5 C NC in air PNP -8 VDC max. 00mA 60 bar -40 C to +5 C NPN open collector -8 VDC max. 00mA 60 bar -40 C to +5 C Processconnection* Electricalconnection Cable PVC Cable PVC Connector M LO 6 G / NC in air PNP -8 VDC max. 00mA 60 bar -40 C to +5 C Connector M * metric threads on request side view AC ~ OUT ~ = Brown = Black = Blue : V+ : 4-0mA+ : GND 4: OUT 5: 4-0mA- Connecting side view + + OUT OUT NPN - PNP - Type A L L SW H LO / LO6 G /", /" NPT 4 8 7 59 Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Straße 794 Kernen Fon 075 40-0 Fax 075 40-49 E-Mail: jacob@jacob-gmbh.de
Optical infrared sensors from Jacob Type LO xx with analogue 4-0mA Temperature output signal Body.457 (AISI 6L) Dome Torque Tighten Glass 5 Nm Weight g 00 Protection grade Repeatability Electronic Protections Scope of supply IP67 ± mm reverse polarity, output short-circuits M, 5-pole Industrial plug Type Processconnection Function Output Temperature output* LO G /" NO in air NPN open collector Power supply Output current (depending on Temperature range) PN max. Temperature range 4-0mA -8 VDC max. 00mA 40 bar -40 C to +5 C LO 4 G /" NC in air PNP 4-0mA -8 VDC max. 00mA 40 bar -40 C to +5 C * according to the fixed Temperature range from -40 C (4mA) to 0 C (0mA) side view : V+ : 4-0mA+ : GND 4: OUT 5: 4-0mA- Connector side view Type A B L L L SW H LO / LO4 G /" Mx 56 5 7 8,5 Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Straße 794 Kernen Fon 075 40-0 Fax 075 40-49 E-Mail: jacob@jacob-gmbh.de
PSU-Resistivity vs Chemicals The polysulphone is a tough rigid, amorphous thermoplastic material. It is hydrolytically stable and has demonstrated long-term resistance to steam. Electrical properties are maintained over a wide temperature (-40ºC + 60ºC) and after immersion in water. The polysulphone is highly resistant to mineral acids, alkali, salt solutions, detergents, hydrocarbon oils. The polysulphone has FDA, USP, -A and NSF approvals, which allow food contact use and medical equipment use. Chemical Resistance + = resistent; 0 = partially resistent; - = not resistent; II = soluble Substance (concentration) Resistance Substance (concentration) Resistance Acetic Acid (80-0%) + Hydrogen Peroxide (0.5%) + Acetone (00%) - Hydrogen Peroxide (%) + Alcoholic Calcium Chloride (0%) 0 Hydrogen Peroxide (%) + Alkaline Solution 0.% CL Active - Hydrogen Peroxide (0%) + Aluminium Chloride (0%) + Hydrogen Peroxide (0%) + Aluminium Sulphur (0%) + Iodine and Potassium Solution - Ammonia (0%) + Iodine Tincture (-) - Ammonium Chloride (0%) + Lactic Acid (0%) + Benzene (00%) - Liquid Freon (00%) + Boric Acid (0%) + Magnesium Chloride (0%) + Butanol (00%) 0 Manganese Sulphur (0%) + Butyl acetat (00%) - Mercury (00%) + Calzium Hypochlorite (0%) + Mercury (5%) + Calzium Sulphur (00%) - Methanol (98%) 0 Carbon Tetrachloride (00%) - Methyl Chloride (00%) 0 Caustic Potash (0%) + Mineral Oil (00%) + Caustic Potash (50%) + Nitric Acid (0%) + Caustic Soda (0%) + Nitric Acid Conc. (65%) - Caustic Soda (50%) + Oleic Acid Conc. (40%) + Chloride Gas (00%) + Ozone (-) - Chorine Water (-) + Petroleum (00%) + Cholorbenzene (00%) II Phenol (0%) - Chloroform (00%) II Phosphoric Acid (0%) + Chorme Alum + Phosphoric Acid Conc. + Citric Acid (0%) + Potassium Bichromate (5%) + Cold Water (00%) + Potassium Nitrate (0%) + Cromic Acid (0%) - Potassium Permanganate (%) + Cyclohexane (00%) 0 Pyridine (00%) - Dibutylphthalate (00%) + Sea Water (00%) + Diesel (00%) + Soap Solution + Dioctylphthalate (00%) + Soda (0%) + Ethanol (96%) + Sodium bisulphite (0%) + Ethyl Acetate (00%) + Sodium Chloride (0%) + Ethyl Ether (00%) + Sodium Solfur (0%) + Ethylene Chloride (00%) II Sulphuric Acid (0%) + Formaldehyde (0%) + Sulphuric Acid (98%) - Formic Acid (85%) + Tallow (00%) + Fuel (00%) 0 Transformers Oil (00%) + Furfural (00) + Urea (0%) + Glycerine (90%) + Wax (00%) + Heptane (00%) + Xilene (00%) - Hexane (00%) + Zinc Choride (0%) 0 Hydrochloric Acid (-0%) + Hydrofluoric Acid (40%) - The approximate values with 0 C, specified here, are not transferable to all operation conditions. The chemical stability of plastics is dependently of the temperature, concentration, radiation effect, mechanical/dynamic stress and not least of the careful production of the work piece (shatter crack danger). Therefore warranty and requirements for compensation cannot be recognized. For specific applications it is essential to make for the operating conditions appropriate attempts. Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Strasse 794 Kernen Fon 075 40-0 Fax 075 40-49 email: jacob@jacob-gmbh.de
Further information about our representatives abroad is available at www.jacob-gmbh.de Jacob GmbH Elektrotechnische Fabrik Gottlieb-Daimler-Straße 794 Kernen GERMANY Phone +49 75 40-0 Fax +49 75 40-49 jacob@jacob-gmbh.de www.jacob-gmbh.de 0/00