SLFE. Ex de. Side view for lamp replacement

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Nightscape High performance floodlights and spotlights for discharge lamps

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Terminal Boxes Series 8146

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Compact pressure switch Flameproof enclosure Ex d Model PCA

Nightspot High performance floodlights for discharge lamps and LEDs

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

Superlight Compact Nano

SEISMIC VELOCITY TRANSDUCER T1-40

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Floodlight Range Installation Guide

Abtech Custom Solutions

Industrial Luminaires

Terminal Box. Specifications TNCN

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Fluxa Area floodlights for high pressure discharge lamps and LEDs

2.12. page Products for Explosion hazardous Environment

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

DuroSite TM High Bay Lighting

Plug and Socket Devices SolConeX 16 A Series 8570

Explosion proof enclosures

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Series 8146/5-V37 and Series 8150/5-V37

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Plug and Socket Devices CES 63 A Series 8579

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

Electric Rotary Actuator - On/Off or programmable control actuator

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Guide to enclosures for potentially explosive atmospheres

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Operating Instructions

8146/5 Series Breaker Panelboards

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

Digital input modules

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Operating Instructions

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

400 Series - Mini USB Buccaneer

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Instructions for Safe Use

Technical Information RIA14

A good connection. International approvals.

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Digital inductive conductivity transmitter

Technical Data. Dimensions

Flameproof Audible Signal 115 db (A) Series YA90

Superlight Compact LED LED floodlights

R.C.C.B. s two-pole LEXIC

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

7000 Series Buccaneer

nano led THE GREEN LIGHT

Standard Buccaneer - USB

distributing & controlling system solutions

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

IVIOS LED III. LUM Technical Information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Linkeo 19" freestanding cabinets

Transformer oil cooler ALFA A02

SITRANS F flowmeters SITRANS F M

Scraper Passage Indicator. Electrical Indicator. Features

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RUBBER SLEEVE KNIFE GATE VALVE

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

3/2-way Solenoid Valve, direct-acting, NC or NO

STB Series Enclosures

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

BSE Geluid en Licht Pagina 1 van 5. Description

Standard Buccaneer - Ethernet

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Technical Data. Dimensions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

CAPACITIVE LEVEL METERS CLM 36

Urban lighting luminaire ECOLO. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Nightspot LED High performance floodlights for LEDs

SOURIAU s discrete wire sealing

RM4TG20 three-phase network control relay RM4-T - range V

Transcription:

Electrical components compartment SLFE - Suitable for high (+55 C) and low (-50 C) temperatures - Easy side access for replacement lamps - Optimal performance at low temperatures (-50 C) - Zones 1, 2, 21, 22 Shock resistant tempered glass Lamp up to 600 W Side view for lamp replacement B.73 ED.2016

Rectangular vertical floodlights New generation SLFE series floodlights have been specially designed to provide the symmetrical, powerful distribution of light in all those areas where an intense, concentrated illumination is needed. The symmetrical reflector makes sure that the light is spread symmetrically in all directions to provide uniform lighting. Their rectangular design is both unique and innovative with the benefit of facilitating maintenance work. Lamps replacement is greatly simplified thanks to access through a side panel and there is no need for the glass to be removed. SLFE floodlights have a built in Ex e terminal board housing that allows to enter the lighting fixture through a cable gland with a Ex O-ring (non barrier) as specified in the installation specification standards (EN/IEC 60079.14). The electrical components (ballast, capacitor, igniter) are thermally separated from the lamp compartment thus ensuring a long and efficient working life. SLFE floodlights can be fitted with lamps of up to a maximum of 600 Watt. SLFE series floodlights also comply with anti light pollution standards (Regional Law date 27 March 2000 N 17 Article 6). Application sectors: Oil Chemical and refineries petrochemical plants Onshore plants Offshore plants Perimeter lighting Anti light pollution Oil loading/ unloading jetties 100% Cortem product CERTIFICATION DATA Group II Category 2GD zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Classification: Installation: EN 60079.14 II 2GD IIB T2/T3 - Ex td A21 IP 66 Marking: Certification: ATEX TR CU Standards: Class temperature: Ambient temperature: Degree of protection: ED.2016 CESI 09 ATEX 009 AVAILABLE All TR CU certification data can be downloaded at www.cortemgroup.com CENELEC EN 60079-0: 2006, EN 60079-1: 2007, EN 60079-7: 2007, EN 61241-0: 2006, EN 61241-1: 2004, EN 60598-1:2008+A11:2009, EN 60598-2-1_1989, EN 61547: 2009 and EUROPEAN DIRECTIVE 2014/34/UE IEC 60079-0:2004, IEC 60079-1:2007, IEC 60079-7:2006, IEC 61241-0:2004, IEC 61241-1: 2004 European Directive 2006/95 Low voltage European Directive 2004/108 Electromagnetic compatibility European Directive 2003/108 WEEE Waste electrical and electronic equipment European Directive 2011/64 RoHS 300 C (T2) Standard -20 C +55 C 200 C (T3) Special -50 C +55 C IP66 B.74 SLFE series

SLFE series Rectangular vertical floodlights MECHANICAL FEATURES Body: Glass face: Gaskets: Internal reflector: Supporting bracket Mounting: Bolts and screws: Entries: Coating: ORIGINAL PRODUCT Low copper content aluminium alloy Shock and high temperature resistant tempered glass Acid, hydrocarbon and high temperature resistant silicone Anodised aluminium Galvanised steel, thickness 5mm 3 x Ø15mm holes Stainless steel 1 x ISO M25 entry. Floodlight complete with REV2IB cable gland for non-armoured cable Epoxy coating Ral 7035 (Light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests) ELECTRICAL FEATURES Lamp holder: E40 ceramic Rated voltage: 230 V AC Rated frequency: 50 Hz Connection: Direct connection to the terminal board L, N, Pe. Section 4 mm 2 Wiring: Silicone rubber cables with glass braid insulation for high temperatures Power factor: 0.96 ACCESSORIES AVAILABLE / SPECIAL REQUESTS Discharge lamp Swivelling base for 360 rotation Different rated voltages Reinforced supporting bracket for mounting on mobile structures Frame for mounting floodlight on pole B.75 ED.2016

SLFE series selection chart Code Type of lamp Lamp holder Watt Class Max surface temp Weight T.a. +55 C C Kg mm SLFE-40IM5 metal halide E40 250 T3 163 36 660x500x270 SLFE-40IM6 metal halide E40 400 T3 193 37 660x500x270 SLFE-40N5 sodium vapour E40 250 T3 163 36 660x500x270 SLFE-40N6 sodium vapour E40 400 T3 193 37 660x500x270 SLFE-40N7 sodium vapour E40 600 T2 221 38 660x500x270 DIMENSIONAL DRAWING Cable gland REV2IB Dimensions in mm Example: Floodlight model SLFE-40N5 DON T FORGET TO ORDER THE ACCESSORIES + Discharge lamp LAMPNAVT250W + + other... see key ED.2016 B.76

SLFE series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY 250 W (ST250W) LAMPNAVT250WPLU High pressure sodium vapour lamp E40 400 W (ST400W) LAMPNAVT400WPLU 600 W (ST600W) LAMPNAVT600WPLU 250 W (MT250W) LAMP250WJMT Metal halide lamp E40 400 W (MT400W) LAMP400WJMT 600 W (MT600W) LAMP600WJMT Front ring with glass In copper free aluminium with tempered glass front G-0494 Supporting bracket galvanised steel G-558 Reinforced supporting bracket for mounting on mobile structures galvanised steel G-558/1 Cable gland for nonarmoured cable ISO M25 (std. range cable 12-17) REV2IB B.77 ED.2016

SLFE series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Reflector anodised aluminium G-555 Ceramic lamp holder E40 750W 16A PORT E-40 Sodium vapour and metal halide ballast 250W R-250 NA 230V 50 Hz 400 W R-400 NA Metal capacitor for mercury vapour and metal halide 250W 20 µf 250V F-30 400W 40 µf 250V F-40 250W 35 µf 250V F-35 Metal capacitor for sodium vapour 400W 50 µf 250V F-50 600W 65 µf 250V F-65 Igniter 250W 400W 600W 700W R 100 R 1000 Frame for mounting floodlight on pole galvanised steel G-0534 Swivelling base for 360 rotation aluminium coating RAL 7035 G-326 + G-327 ED.2016 B.78

Construction features Front ring with glass Sealed cable gland Cable gland REV2IB Close up of terminal board Electrical components (ballast, igniter, capacitor) installated in separate housing. Terminals The floodlight is fitted with an Ex e terminal board housing that allows the floodlight to be positioned in ZONE 1 with an Ex non sealed cable gland. Cover Lamp Removing the side panel gives direct access to the inner compartment of the floodlight thus greatly facilitating lamp replacement. B.79 ED.2016

Photometric diagrams SLFE-40 250W halide SLFE-40 400W sodium SLFE-40 250W sodium SLFE-40 400W halide On Cortem Group web site you can download.ldt and.ies lighting data files for the design and simulation of lighting levels in 2D and 3D, rendering and ray tracing. = plane 90270 = plane C 0180 ED.2016 B.80