Single and Output Programmable Solenoid Driver By now, you may have used heard about electro-hydraulic proptional solenoid driver. When dering this driver, the engineers need to determine in advance what type of input signal, output signal, and processing features they might want to have in their design. With the technology available today, we offer a programmable integrated electro-hydraulic single dual solenoid driver which gives the engineers the flexibility to set and reset what is required in their application. On top of that, we include the output display feature to eliminate any guess wk on what the actual output power level is. This feature alone will save your technician and maintenance personnel troubleshooting time. The -O is a DIN rail mounted Single Output Programmable Driver f open loop control systems. The ramp time could be disabled f maximum response time f closed loop applications. The 2-O is a DIN rail mounted Output Programmable Driver f open loop control systems, designed to drive any brand of hydraulic and pneumatic proptional valve up to 2.5A. A single input command will drive the output A and output B automatically and the ramp time could be disabled f maximum response time f closed loop applications. The -C & 2-C is a DIN rail mounted Single and Output Programmable Driver f closed loop control systems. It utilize a PID control algithm with programmable digital gain settings. (Currently in development - to be released in January 2005) Power conversion, software and cable f Palm PDA and Windows operating systems.
Pressure Control Many different proptional pressure relief valve is designed to wks in different way. To achieve the same objective, this Single Driver is designed to give the engineer the flexibility to control the pressure setting at low cost. Engineer can set reset the control features within the without actually changing the electronic amplifier. Pressure control can be set by an Command signal by Softshift Digital Input A1 A2. Flow Control This Single Driver can provide a proptional flow control to control the acceleration, speed, and the deceleration of wide range of applications. Use Program to do the followings: Select Digital Control. Set IN-A1 Output Current. Set IN-A2 Output Current. IN-A1 and IN-A2 will share the same parameter setup: Deadband; Ramp Time; Dither Freq. and Amplitude Open Loop Control System, Output is ramped by Digital Softshift Command Typical Connection OUTPUTS GND 8 Out + 10 Out - 11 Vdc Command 0-5 Vdc 1-5 Vdc 0-10 vdc 3 4 7 8 9 Prop. Connection Connection 3 +10 Vdc 4 0 Vdc 7 CMD + 8 CMD (0V) 9 GND Softshift Connection Softshift-1 Softshift-2 15 IN-A1 16 IN-A2 +10 Vdc 0 Vdc CMD + CMD (0V) GND ma Command 0-20 ma 4-20 ma 3 +10 Vdc 4 0 Vdc 6 CMD + 8 CMD (0V) 9 GND Digital Source IN-A1 IN-A2 Open Loop Control System, Output is proptional to the Input Command Closed Loop Control System, closing the loop at (Most Practical) Output Input Closed Loop Control System, closing the loop at with Option Card Built-in Output Input Option Card Primary Secondary The proptional output ramps up and down accding to the program acceleration and deceleration ramp time Flow Closed Loop Control System with Primary and Secondary Rotating Equipment RPM
By now, you may have used heard about electro-hydraulic proptional solenoid driver. When dering this driver, the engineers need to determine in advance what type of input signal, output signal, and processing features they might want to have in their design. With the technology available today, we offer a programmable integrated electro-hydraulic single dual solenoid driver which gives the engineers the flexibility to set and reset what is required in their application. On top of that, we include the output display feature to eliminate any guess wk on what the actual output power level is. This feature alone will save your technician and maintenance personnel troubleshooting time. Directional Control direction control valves control both the direction and the amount of flow in response to an electrical signal. This Driver is designed to respond to the electronic input command signal, controlling the electrical output to drive the proptional valve. Engineer and technician have a wide range of flexibility to set and reset the control features within the without actually changing the electronic amplifier. Application Using the programming tool, the engineer technician has the option to program the following parameters: Input (Select One) +/- 5 vdc +/- 10 vdc +/- 20 ma (5k Ohms) Output (Enter Value) Maximum Output Level 0.5A to 2.5A Features Accel.Ramp Time 10 msec to 10 sec.* Decel.Ramp Time 10 msec to 10 sec.* Deadband Comp: 0-10% ** Dither Amp: 0-10% ** Dither Freq: 70-350 hz Control ON/Bypass * To disable Ramp Time, set Ramp Time to 0. Minimum Ramp Time is 10 msec. ** Deadband Compensation and Dither Amplitude % setup is equal to percent from rated output Amperes Setup f Open and Closed Loop Control System Open Loop Control System, Output is proptional to the Input Command Closed Loop Control System, closing the loop at (Most Practical) Output Input Output Input Primary Secondary Flow Closed Loop Control System, closing the loop at with Option Card Closed Loop Control System with Primary and Secondary Rotating Equipment RPM
1/2004 Single and Output Programmable Solenoid Driver -O & 2-O Wiring Diagram 1 2 3 4 5 6 7 8 Power Level Output [%] Cmd. V Cmd. ma Output A Output B Term. 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 Name PWR+ COM +10 Vdc 0 Vdc -10 Vdc CMD V CMD Vref CMD A CMD Aref OUT A+ OUT A- OUT B+ OUT B- IN-A/A1 IN-B/A2 Descriptions Power Input: 10-30 Vdc Power Input 0 Vdc (COM) +10 Vdc f 0 Vdc Reference -10 Vdc f Command Vdc+ Signal Command Vdc- Signal Command ma+ Signal Command ma- Signal Output Signal A+ Output Signal A- Output Signal B+ ( Channel) Output Signal B- ( Channel) Digital Input (Enable Output) Programmable Input A/A1 Programmable Input B/A2 Pot. X Local/Remote Power Plug (Softshift) This module can be used as Power Plug as Flow Control valve Pressure Control. RS 232 Term-: Enable connection is f safety. This signal must remain high energized to turn Output on and can not be bypassed by the program. This connection could be used f soft emergency stop signal. Term-15: Digital Input IN-A Digital Input IN-A could be programmed as Softshift f Output A ( Single Output -O). When this input is energized, the Output A will be ramped to a preset current accding to the programmed Ramp Time (10 msec to 10 sec). Contact: 9 10 11 12 13 15 16 Term-16: Digital Input IN-B Digital Input IN-B could be programmed as Softshift f Output B ( Output 2-O). When this input is energized, the Output B will be ramped to a preset current accding to the programmed Ramp Time (10 msec to 10 sec). Digital Inputs IN-A and IN-B Softshift Control If both digital inputs are triggered (ON), only one output, based on first trigger first serve, will be executed. Both digital inputs must be disabled to utilize the analog command. All other programmed features, such as Dither Frequency, Dither Amplitude, Deadband Compensation will be executed accdingly.
Applications Accurate control of hydraulic and pneumatic proptional solenoid valves used in industrial and mobile equipment control system. The combination of proptional valve and this Programmable Driver offers low cost solutions to many hydraulic and pneumatic applications with Power Level Output display f ease of troubleshooting and maintenance. Closed Loop Applications The -O and 2-O can be used f closed loop applications. Loop closure could be done via micro process based units, such as PC board, Programmable Logic Controller (), and any other third party controller board which has the closed loop algithm. Currently, we are developing -C and 2-C, which is a stand alone closed loop systems, utilizing the PID algithm with digital gain adjustment. Key Features & Benefits Broad range of DC Power Input: 10-30 vdc Programmable Gain Adjustment (output/input) Programmable Ramp Time 0, 100 msec - 10 sec Programmable Dither Frequency 70-350 hz Programmable Dither Amplitude 0-10% of output Programmable Deadband Compensation Output Power Level Indicat 0-99% Built-in Local Control f troubleshooting Programmable via PDA Additional Benefits One Size Fit All design approach where the input and output(s) are programmable to fit your application. No heat sink required, sht circuit protected, and power level indicated (no guessing required). Transient Power and Reverse Polarity Protection. Control Mode Local Remote: Local f troubleshooting directly from the embedded potentiometer. Remote f controlling the output from remote analog source. Input: 0-5 vdc, 1-5 vdc, 0-10 vdc, 0-20 ma, 4-20 ma using built in CMD source +/- 5vdc, +/- 10 vdc, +/- 20 ma using built in CMD source Output: Programmable 0.5-2.5A 2-O Single -O Softshift #1 (Term.15) Single Softshift #2 (Term.16) -O Softshift Output A (Term 15) Softshift Output B (Term 16) 2-O Hardware Features Input Power: Accept 10-30 Vdc Output Power: Level display 0-99% Built in Command Power: +/- 10 Vdc Status LED Display: - Control Cmd. V - Voltage Command Cmd. ma - ma Command Output - Output to Channel A Local/Remote Switch: Local - Local Pot to control output Remote - to control output Pot - Potentiometer to control output locally RS232 Pt: Windows 98, NT, and 2000 USB Pt: PDA Programming (option) Wiring Terminal: Up to 16 AWG Softshift Inputs: Term. 15 & 16 Software Features Program & Status LED Display: - Program Control Cmd. V - Program to Voltage Cmd. Cmd. ma - Program to ma Cmd. Output - Auto Select Single Channel Programmable: Output Power: up to 2.5A Ramp Time: 100 msec to 10 sec. Dither Frequency: 70-350 hz. Dither Amplitude: 0-10% of Output Deadband Compensation Softshift #1 (Term.15) Softshift #2 (Term.16) Single -O Softshift Output A (Term 15) Softshift Output B (Term 16) 2-O Physical Dimension: 2"(W) x 4 1/4"(L) x 4 3/4" (H) Warranty All our products are thoughly inspected befe shipment. In the event of any malfunction, contact your representative. Contact: Distribut and Reseller We are the links between manufacturers and resellers, focusing on the electro-hydraulic control components