2 in1 SOL ARTUBE SIMPLE. FLEXIBLE. FAST. SPECIFICALLY TO BE USED TO INSTALL FLOW & RETURN PIPES FROM SOLAR PANEL TO STORAGE TANK



Similar documents
Assisted lift operated 2/2-way solenoid valves Type EV250B

Solar Collector Series. Product List

SOLARE SOLAR TUBI CORRUGATI PER IMPIANTI A PANNELLI SOLARI CORRUGATED TUBES FOR SOLAR PANEL INSTALLATIONS. Set di due tubi corrugati e formabili CSST

Company and Product Presentation

Working Pressure up to 630 bar / 9135 PSI

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

Solar Hot Water Heaters

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Transport & Automotive CATALOGUE. March Customer Service Phone: Fax: sales@tubefit.com.au.

Hose and Tube Fittings Series 1-3

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

building applications copper - redefined

Installation instruction CASAFLEX - Connecting piece DN 100

Cables. Accessories. For Force, Torque and Strain Sensors

Installation Instructions for Contractors. Connection Sets. Solar Twin Tube. Inox 1/2" Inox 3/4" (2011/02) US/CA

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

Stainless steel process fittings

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Series 8146/5-V37 and Series 8150/5-V37

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Operating Instructions for Plastic Flow Meter. Model: KSK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Engineering Specifications

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

VSH Press Sprinkler Galvanized System

STENCA PIPE. High quality pipe insulation.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

kymanual or Automatic - it s your Choice

FLEXIBLE THERMAL INSULATION MADE OF SILICONE

Self-operated Temperature Regulators Temperature Regulator Type 1u

Festoon 715 P PUR cable for flexible application in festoon systems

How To Buy A Designo Grille

TARIFF CODE and updates standard

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

Air Conditioner Water Heater Model ACWH18

SOURIAU s discrete wire sealing

Physically Crosslinked Foam Insulation

Questionnaire Pure Media Systems

Master Panel 1000 R5 Roof

BRASS FITTINGS FOR THREADED PIPES

Master Panel 1000 W Wall

Metal Pressfitting Pipe Systems

Operators manual Basic water heater

Hose Clamps & Fittings

Fire retardant IEC

Rules for Classification and Construction Additional Rules and Guidelines

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Unbeatable energy efficient glass curtain wall system

FITTINGS A series Aluminium (light weight) compression fittings Ø mm tube size, BSPP and BSPT thread

stainless steel pre-assembled manifolds

Digital inductive conductivity transmitter

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Cable Plug acc. to DIN EN , Form A

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GEET Fuel Processor Plans

Commercial Electric Water Heater

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

NiroSan -Press SANHA -Press SANHA -Therm 3fit -Press 3fit -Push

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Bimetal thermometer Model 52, industrial series

ATL Fuel Level Sender Probes

Geberit Mapress Catalogue 2008 / Valid from 1 April 2008

Solenoid valves 2/2-way direct-operated Type EV210A

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

SunMor SM-V30 Solar Water Heater Installation Manual

Toroidal Conductivity Sensor

Multi-layer Insulation Blanket for Roofs

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

GK Packing System Welding Instructions

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

VIPERFLEX ELECTRIC CABLE

Plastic tubing, standard O.D.

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Product Data Sheet ROCKPANEL Rockclad

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Screw Thread Design. Rev

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

Stainless Steel Valves For the Sanitary Industries

The original heating cable just got better

Transcription:

2 in1 SOL ARTUBE SIMPLE. FLEXIBLE. FAST. Flexible stainless steel pipe Solar UV resistant protective sheath Break joint for easy separation Integrated two-core sensor cable Closed cell elastomeric foam insulation SPECIFICALLY TO BE USED TO INSTALL FLOW & RETURN PIPES FROM SOLAR PANEL TO STORAGE TANK WWW.LIVINGGREENSOLAR.COM.AU

2 in1 SOLARTUBE FEATURES & BENEFITS ADVANTAGES spaces. Two closed cell elastomeric foam tubes of high temperature resistant EPDM are reliably protected against mechanical damage by a protecting UV Resistant coating. Flow & Return pipes can easily be separated without damaging the insulation or the protective coating. 2 in1 SOLARTUBE is the way to reduce installation time whilst ensuring a leak free installation. DESIGN OF THE CORRUGATED PIPES The corrugated stainless steel pipes have a wide pitch. Therefore, they are very malleable and easy to install. Even smallest bending radii can be obtained without a kink. The welding seams are free of annealing colour and the pipes are tested for 100% leak tightness. All pipe ends are cut neatly, free of burrs and are covered with plugs. INSULATION WITH UV RESISTANT PROTECTING SHEATH The insulation consists of two insulation tubes which are joined together by a tear resistant black protecting especially in spaces where the tube is bent. The two insulated pipes can easily be separated by cutting the ligament. The compatibility of the insulation material and the corrugated stainless steel pipes is guaranteed. (R.06 includes pipe and UV solar insulation when assessed in accordance with AS/NZS 4859.1, Para 2.3.3.8.) Components: 2 in1 SOLARTUBE corrugated stainless steel pipe (Grade: 1:4404 / AISI316L) UV Resistant, High Temperature closed cell EPDM (no CFC or HCFC) 2 in1 SOLARTUBE QUICK JOINT FITTINGS after you hear the «CLACK», which guarantees that the compression ring on the pipe is in the correct position, CLIMATE ZONE DOCUMENTATION Please see website for relevant information - www.livinggreensolar.com.au

2 in1 SOLARTUBE TECHNICAL INFORMATION Description elastomeric foam (EPDM) Water vapour resistance 4.500 according DIN EN 13469 # Insulating sheath Fire reaction: B2 class (according to DIN 4102) Manufacturing process R6 Value Free of CFC, HCFC, Formaldehyde and Cadmium # When assessed in accordance with AS/NZS 4859.1 Paragraph 2.3.3.8 Max working temperature +175 C intermittent (150 C continuous) * Min working temperature - 50 C * Flexible stainless steel pipe Thermal conductivity (λ) Particular characteristic: Thickness: Material: Temperature range: Max working pressure: at 0 C: 0,038 W/(mK) at 40 C: 0,042 W/(mK) UV resistance; without CFC and HCFC 15 mm ± 1 mm Stainless steel AISI 316L - Grade 1:4404 (X2CrNiMo 17122 according to EN 10088) -200 C to +600 C DN12-2000kPa DN16-1000kPa Conductor material: E-Cu ETP (according to DIN EN 13602) Two-core sensor cables Core insulation: Silicone type El 2 (according to DIN VDE 0207) Outer diameter: 2.15 mm Width (2 cables): 4.40 mm2 Section: 2 x 50mm Max working temperature: +180 C Min working temperature: - 40 C 2 in1 Quick Joint Fittings Max Working Temperature + 280 C Max Working Pressure 16bar Material Body: DZR CW602N brass / R Series Thread # According to DIN EN ISO 10380 (100kPa = 1bar)

2in1 SOLARTUBE PRODUCT INFORMATION WARRANTY 2in1 SOLARTUBE system Life expectansy of 2in1 SOLARTUBE system 10 Years 25 Years PRODUCT CODES DN12 CODE DN16 CODE 2in1 SOLARTUBE FITTINGS 1/2 Male Adaptor 0710110 1/2 Male Adaptor 0710118 3/4 Male Adaptor 0710111 3/4 Male Adaptor 0710119 1/2 Female Adaptor 0710113 1/2 Female Adaptor 0710120 3/4 Female Adaptor 0710114 3/4 Female Adaptor 0710121 DN12 Union 0710112 DN16 Union 0710122 1/2 Female Elbow 0710116 1/2 Female Elbow 0710123 3/4 Female Elbow 0710117 3/4 Female Elbow 0710124 12.7mm Copper Union 0710115 12.7mm Copper Union 0710125 2in1 SOLARTUBE PIPE DN12 X 20m Coil 0211220 DN16 x 20m Coil 0211220

2in1 SOLARTUBE QUICK JOINT FITTINGS INSTALLATION GUIDE Posizionare la lama nella scanalatura perpendicolarmente al tubo. Place the blade in the groove perpendicularly to the pipe. Il taglio deve essere netto, senza bave. The cut must be clean and without burrs. Non smontare il raccordo: qualora succedesse accidentalmente, il piede dell anello interno va in appoggio sul corpo raccordo. Do not disassemble the fitting: should this accidentally occur, the foot of the inner ring must be rested on the fitting body. Spingere il tubo nel raccordo fino ad avvertire lo scatto CLACK (fig. 6). Push the pipe into the fitting until the CLACK sounds (fig.6). Allentare manualmente il dado di circa 1/2 giro, salvo non lo sia già (fig. 5). Manually loosen the bolt by approximately 1/2 rev, unless is not already loose (fig.5).

AUSTRALIAN STANDARDS REFERENCE ATS - 5200.489.2009 In accordance with reference: AS/NZS - 3500.4.2003 AS/NZS - 14589.1.2002 Licence WM022290 IAPMO Oceana ABN: 65 808 115 387 SALES@LIVINGGREENSOLAR.COM.AU WWW.LIVINGGREENSOLAR.COM.AU T: 03 9708 2600 F: 03 9708 2700 M: 0432 397 799 6 NETWORK DRIVE CARRUM DOWNS VIC 3201