RHINO VALVES WORLDWIDE

Similar documents
Tyco PremiAir Pneumatic Actuators

Pneumatic actuators The Original! Technics of the top class.

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

RUBBER SLEEVE KNIFE GATE VALVE

Pneumatic Actuators. Crafted without compromise, to make your life easier. The Leader in Actuator Technology

Valv-Powr Series VPVL Stainless Steel Model D Double-Acting and Spring-Return Rack-and-Pinion Compact Pneumatic Actuators

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Experience In Motion. Valtek Spring Cylinder Linear Actuators

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

1 Important Safety Procedures. Qualified maintenance personnel should read and follow these straightforward instructions.

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Richter Twin Piston Quarter-turn Actuators

2/2 and 3/2 Way Size 6 Seat Valves

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

PVM Piston Pumps Service Manual

Fisher 657 and 667 Diaphragm Actuators

MP-4V Heavy Duty Riveter / 39048

Extruded Body Cylinders, ISO 6431, ISO compliant Series 62

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

HYDRAULIC LIFT TABLE CART 2200-LB.

Single sub-base valve

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

A descriptive definition of valve actuators

3097 en / e. This manual is to be given to the end user POULIBLOC Shaft mount reducer. Installation

V&A PROCONTROL. Rotary Valve Actuators Pneumatic & Hydraulic On-Off / Control / ESD Double Acting Spring Return All Steel SIL 3

HOPPER SHAPE KNIFE GATE VALVE

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Fuel Injection Pump, Rotary ( )

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Introduction to Process Control Actuators

Pipe Cutting and Beveling Clamshells

Unit 24: Applications of Pneumatics and Hydraulics

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Electric Rotary Actuator - On/Off or programmable control actuator

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

FLANGED END BALL VALVE

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Control blocks for two-hand start ZSB

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

STEERING SYSTEM - POWER

Hydraulic multidisc Brake H420

PRESSURE REDUCING CONTROL VALVE

MANTA Piston Distributor for Oil and Fluid Grease

Hydraulic Control Solutions

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

DeZURIK 3" (75MM) & LARGER ECCENTRIC PLUG VALVES

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Many Products...One Source

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Control- and feedback head for integrated mounting on Robolux valves Type 2036

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Selecting and Sizing Ball Screw Drives

Example. Fluid Power. Circuits

Plastic Injection Molding

3/2-way Solenoid Valve, direct-acting, NC or NO

Rebuild Instructions for and Transmission

Rexroth Hydraulic Pump A10VO Series User Manual

ANGLgear. right angle drives Inch and Metric Series. The Original Right Angle Gear Drive Made in the U.S.A.

SOLENOID VALVES AND PNEUMATIC VALVES

DPE Parallel Gripper- Electric Gripper Series

Basic Hydraulics and Pneumatics

Unit 24: Applications of Pneumatics and Hydraulics

Machine needle shut-off nozzle type HP

Proportional pressure regulators VPPE

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

2100 AD Mirror Elevator Ball Nut Replacement Procedure

Fisher 377 Trip Valve

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Universal Adjustable Fuel Pressure Regulator

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Mercedes

LINEAR MOTION CONTROL

DYNA RIDER FOOTBOARD KIT

AMG Antrieb und Mechanik GmbH

POWERS Controls No. 4 Pneumatic Damper Actuator

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Oregon Fuel Injection

Fisher 377 Trip Valve

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE Part #: HT-1

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

ZF 301 A. Marine Propulsion Systems

Transcription:

RHINO VALVES WORLDWIDE Pneumatic Actuators Robust, reliable, rapids. Suitable to any 90 degrees rotation valves In different configurations for any application and adaptation of other automation devices.

The double pneumatic actuator Rack and Pinion of RHINO is one of the best designs in the market. Available as Double Action (Air-air) or Spring Return with torque outputs for small to large flanged valves. Both actuators have twin cylinders, horizontally opposed incorporated piston guides to assure the correct contact between the Rack and Pinion facilitating that the kinetic energy is transformed directly in a turn room that will provide a soft and constant torque. Prepared with bores and threads that meet the international standards NAMUR and ISO. Built in aluminum extrude robust, but light and resistant to the environmental corrosion. PRINCIPLE OF OPERATION OF THE ACTUATOR ISO5211 WITH SPRING RETURN. A pressure applied to the Port A will cause the internal cavities to pressurize, forcing the pistons to move toward the end, compressing the springs. The axis rotates in a counter clockwise motion. When stopping the application of pressure in port A the springs will exercise pressure to close the pistons and to rotate the axis quickly in a clockwise motion. This action is frequently used to close a valve of a turn room in a way usually closed. The axis will rotate in counter clockwise motion when pressure is applied in Port A, it forces the pistons to separate. During this operation, the air of the external cavity is expelled through port B. The turn of the axis in a clockwise motion is achieved previously with the action contrary to the previously described applying pressure in port B. C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/2

CONSUMPTION OF AIR MODEL AP1 DA/SR AP2 DA/SR AP3 DA/SR AP3.5 DA/SR AP4 DA/SR AP5 DA/SR AP6 DA/SR AP8 DA/SR SENSE CONTRARY TO THE LITERS 0.08 0.12 0.24 0.48 0.68 1.4 3.2 5.3 POINTERS OF THE CLOCK FEET³ 0.003 0.004 0.008 0.017 0.049 0.049 0.11 0.18 SENSE CONTRARY TO THE POINTERS OF THE CLOCK LITERS 0.1 0.16 0.44 0.56 0.96 2.16 4 8.6 (ONLY DA) FEET³ 0.0035 0.005 0.015 0.02 0.034 0.076 0.014 0.3 MODEL AP1 AP2 AP3 AP3.5 AP4 AP5 AP6 AP8 DOUBLE SMALLER SMALLER SMALLER SMALLER SMALLER SMALLER 1.5 ~ 2 3 ~ 4 EFFECT THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. THAN 1.25 SEG. SECONDS SECONDS RETURN FOR SMALLER SMALLER SMALLER SMALLER SMALLER 1.5 ~ 2 2 ~ 3 4 ~ 6 SPRING THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. THAN 1 SEG. SECONDS SECONDS SECONDS WEIGHT MODEL AP1 DA AP2 DA AP3 DA AP3.5 DA AP4 DA AP5 DA AP6 DA AP8 DA KILOGRAMS 0.85 1.62 2.92 4.18 5.86 11.18 21.20 43.00 LIBRAS 1.87 3.57 6.44 9.22 12.92 24.65 46.75 94.82 WEIGHT MODEL AP1 SR AP2 SR AP3 SR AP3.5 SR AP4 SR AP5 SR AP6 SR AP8 SR KILOGRAMS 1.08 1.74 3.16 4.66 6.34 13.1 24.60 54.50 LIBRAS 2.38 3.84 6.97 10.28 13.98 28.89 54.20 120.20 C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 2/2

SPECIFICATIONS Range of pressure: Double Acting: 2 bar (29 psi) to 8 bar (116 psi) Spring return: 3 bar (44 psi) to 8 bar (116 psi) Maximum pressure of operation 10 bar (145 psi). Environment: lubricated dry-air, do not use corrosive gas, water or hydraulic oil. Range of temperature: Standard : -4ºF (-20ºC) to + 175ºF (80ºC) Optional : -68ºF (-120ºC) to 302ºF (+150ºC ) Recommended: -58ºF (-50ºC) to 175ºF (+80ºC ) Rotation: counterclockwise when pressure is applied to the Port "A". Clockwise when pressure is applied to the Port B and spring Return operation (see operation principle). Opening : 90 degrees adjustable of 3 degrees to 3 degrees. Lubrication: All the parts are lubricated for longer life. Construction: Appropriate for interior or external facilities. Connections: Inferior connection according to the standard ISO5211/DIN 3337, interfaces with solenoid valve and superior connection for compatibility of accessories with the international standard VDI/VDE 3845 NAMUR. Inspection: Each unit is proven hydraulically and certified. C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/1

We offer double acting and spring return units whit torque outputs from small to larger flanged valves. Mounting pads are drilled and tapped to international NAMUR and ISO standards. Rhino offers a full array of solenoids, limit switches, positiones and other accessoies to meet customer needs. Double acting and Spring return actuators are the same size. Item DESCRIPTION Q.ty 1 ACTUATOR BODY 1 2 PISTON 2 3 END CAP 2 4 PINON 1 5 PISTON GUIDE 2 6 PINION GUIDE RING 1 7 O-ring 1 8 PINION GUIDE RING 1 9 O-ring 1 10 CIRCLIP 1 11 THRUST WASHER 1 12 PLUG 2 13 LOADED SPRINGS 4-12 14 SCREW EXTERNAL STROKE 2 15 O-ring 2 16 PLAIN WASHER 2 17 STOP NUT 2 18 END CAP BOLTS 8 19 O-ring 2 20 PISTON GUIDE RING 2 21 O-ring 2 22 CIRCLIP ANTI-BLOW OUT 1 DESCRIPTION MATERIAL FINISH Actuator Body Extruded Aluminium Alloy Gold Anodized End Cap Pressure die casting Aluminium Alloy Black Epoxic Coated Pinion Carbon Steel E.N.P. Piston Pressure die casting Aluminium Alloy Natural Guide Acetal Resin Natural "O" Rings Buna N 60 IRHD Springs Spring Steel Epoxic-Coated or Dacromet320 Screws and Nuts Stanley Steel Natural C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/1

They are only as reference and they are subject to changes without previous notice. Dimension in inches. MODEL A B C D E F G H K L M N P Q R S T U V W X AP1 DA/SR 5.39 2.64 2.36 3.43 0.79 1.65 1.61 0.47 0.31 - - - 3.15 1.18 0.98 0.39 0.08 0.35 1.42 - - - (M5) - - - 1/8" F03 - - - AP2 DA/SR 5.91 3.27 2.87 4.06 0.79 1.65 1.75 0.47 0.31 - - - 3.15 1.18 1.38 0.47 0.08 0.43 1.65 1.97 (M5) (M6) 1/4" F04 F05 AP3 DA/SR 8.03 3.94 3.35 4.72 0.79 1.97 1.95 0.55 0.39 - - - 3.15 1.18 1.38 0.63 0.12 0.55 1.97 2.75 (M6) (M8) 1/4" F05 F07 AP3.5 DA/SR 9.06 4.33 3.86 5.12 0.79 1.97 2.09 0.75 0.55 - - - 3.15 1.18 2.17 0.79 0.14 0.67 2.75 - - - (M8) - - - 1/4" F07 - - - AP4 DA/SR 10.67 4.92 4.33 5.71 0.79 1.97 2.28 0.75 0.55 - - - 3.15 1.18 2.17 0.79 0.14 0.67 2.75 4.02 (M8) (M10) 1/4" F07 F10 AP5 DA/SR 14.17 6.10 5.51 7.28 1.18 - - - - - - 1.10 0.79 5.12 3.15 1.18 2.76 0.94 0.14 0.87 4.02 - - - (M10) - - - 1/4" F10 - - - AP6 AD/SR 18.19 7.87 6.89 9.06 1.18 - - - - - - 1.42 1.10 5.12 3.15 1.18 3.35 1.14 0.14 1.06 4.92 - - - (M12) - - - 1/4" F12 - - - AP8 AD/SR 21.85 9.48 8.46 11.81 1.97 - - - - - - 1.89 1.26 5.12 - - - 1.18 3.94 1.50 0.20 1.42 5.51 - - - (M16) - - - - - - F14 - - - ISO5211 C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/1

TORQUES DOUBLE ACTION. To size a double acting actuator please follow the follow these instructions: Determine the torque required by the valve, including the recommended security factor of 25% and the minimum pressure of air of available operation. Find it in the following chart and select the column of the minimum pressure of applicable air. find it in the column going down, until finding a torque not smaller than the one required (do not forget the security factor). Next, on that same line, look for the first column on the left and read the number from the pattern to be ordered. Example, torque of the valve (to the operating pressure and the flow media) 80 Nm + 25%=100 Nm Suppose a minimum pressure of air of operation of 5 bar. Looking for it down in the column of 5 bar a value not smaller than 100 Nm, we find 119 Nm. Model's number indicated in the first column on the left of that line is AP4 DA. WORKING PRESSURE BAR/PS1 bar 2 3 4 5 6 7 8 MODEL psi 29 44 58 73 87 102 116 Nm 5.9 8.9 11.8 14.8 17.7 21.7 24.8 AP1 DA lbf.in 52.6 79.3 105.2 132.0 157.8 193.5 221.1 Nm 9.4 14.1 18.8 23.5 28.2 32.9 37.6 AP2 DA lbf.in 83.8 125.7 167.7 209.6 251.5 393.5 335.4 Nm 20.0 30.0 40.0 50.0 60.0 70.0 80.0 AP3 DA lbf.in 178.4 267.6 356.8 446.0 535.2 624.4 713.6 Nm 34.0 51.0 68.0 85.0 102.0 119.0 136.0 AP4 DA lbf.in 303.3 454.9 606.5 758.2 909.0 1061.5 1213.2 Nm 48.0 71.0 95.0 119.0 142.0 168.0 192.0 AP5 DA lbf.in 428.2 633.3 847.4 1061.0 1266.6 1498.5 1712.6 Nm 111.0 167.0 222.0 278.0 333.0 388.5 444.0 AP6 DA lbf.in 990.1 1489.6 1980.2 2479.7 2970.4 3465.4 3960.5 Nm 227.0 340.0 454.0 567.0 680.0 794.5 908.0 AP7 DA lbf.in 2024.8 3009.0 4049.6 5057.6 6065.6 7087.0 8099.4 Nm 426.0 638.0 851.0 1064.0 1276.0 1491.0 1704.0 AP8 DA lbf.in 3800.0 5691.0 7591.0 9491.0 11382.0 13299.0 15200.0 FOR SPRING RETURN. To size a SPRING RETURN actuator follow these instructions: Determine the torque required by the valve, including the recommended security factor of 25% and the minimum pressure of air of available for operation. Select in the following chart the column of SPRING TORQUE /0º and look for it going down until finding a torque value not smaller than the one required (Please do not forget the security factor). Next, on that same line, look toward the left column of the minimum applicable air and 0º degrees. The opposing value will also be bigger than the required torque (otherwise look for a bigger actuator). Look for the first column on the left and read the number from the pattern to be ordered. Example: Torque of the valve (to the operation pressure and the driven means) 60Nm + 25%=75Nm Suppose a minimum air pressure of operation of 5 bar. Looking down in the column of breakaway TORQUE / 0º a value not smaller than 75 Nm, we will find 108 Nm. Looking for it to the left in the column of 5 bar and 0º you will find 108 Nm, as well as it is bigger than the one required, the Model number indicated in the first column on the left of the line is AP5 SR5. C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/2

C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 2/2

INSTRUCTIONS OF INSTALLATION AND MAINTENANCE INSTALLATION 1. Lubrication: the mobile parts are lubricated in the warehouse and they don't usually require maintenance. However, under extreme conditions of operation, these parts might require re-lubrication. 2. Air supply: the actuator can be supplied with dry or lubricated filtered air. Water or slight oil can also be used. To use with non corrosive gases, please consult our office or distributors 3. Manual operation : when the actuator is totally depressurized, it can be operated with lever or gearbox in the event of an emergency. 4. Adjustment: the actuators have a 90 degrees stopping point which can be adjusted +/-3 degrees through a screw inside the cover by using a screwdriver. MAINTENANCE IMPORTANT: BEFORE DISMANTLING MAKE SURE THAT ALL THE AIR AND ELECTRIC CONNECTIONS HAVE BEEN DISCONNECTED. A Remove the screws (18) from the ends (3). B Removes the ends (3). C Rotate the gear (4) counter clockwise to allow the piston to come out from de body. D Remove the safety washer (10) from the gear (4). E Remove the gear (4) from the lower part of the body by pressing with the fingers from the top. F Replace the following parts if necessary: Pistons (2): O-rings (21) of the piston, nylon guides (20). Body ends (3): O-rings (19) the body ends Piston: Ring guides (superior and inferior) (6 and 8), Or-rings (7 and 9). Note: Internal parts as the cylinder, gear and ring guides should be lubricated with LITHIUM 2 (Bradford Oil Co.). To reassemble, follow the previous procedure in the inverse order. C.P. 09819 Sales phone 01 (52) 5670-51-55 / 5670-7101 Page 1/1