7EM Temperature Controllers

Similar documents
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

WD-AMX Water Detection Controllers

Panel Meters and Controllers Modular Panel Meter Type EDM 35

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

38 Series - Relay interface modules A

TC-9102 Series Surface Mount Temperature Controllers

650W Single Output Power Supply

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Controller Automation, Model II+

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Electronic Control Devices The European Product Catalogue 2007

IO-DIM6 6-Channel, Digital to Analogue Converters

38 Series - Relay interface modules A

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Digital Pressure Measuring Instrument MDR480

ACS-30-EU-EMDR-10-MOD

Model: DC-A2IO Advanced HVAC Controller

User Manual Auto Tuning PID Temperature Controller

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Energy Management Energy Meter Type EM23 DIN

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

48 SERIES Relay interface modules 10 A

IO-RM3 3-Stage Relay Module

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

+ A B V B NO NC V COM PV PV

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Meter Series 700

Thyristor-controlled power supplies and battery chargers

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Contents. Document information

T0118 T2118 T3118. Instruction Manual

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Radiant Temperature Sensor TY7321

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

DLP-PU/E Instruction Manual

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Water Leak Detection System

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Power Supplies 3. SDN-P DIN Rail Series

PRODUCT PROFILE FEATURES

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Solid State Timers Type F

Digital Keypad Use s Manual

Delta Temperature Controller User Manual

CQM1-SF200/CS1W-SF200

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

SMART SENSOR COLLECTION

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

T7079A,B Solid State Remote Temperature Controllers

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

RM4TG20 three-phase network control relay RM4-T - range V

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

49 Series - Relay interface modules A. Features

FIREDEX Conventional Fire Panels

Problem / Solution. The problem:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Adjustment functions for both span and shift have been incorporated

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TC 1818a. Operating Guide. Control Module SWM-015.5

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Switch Mode Power Supply S8VS

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

PIEZOMETER AIRFLOW MEASURING RING

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Emergency lighting units EM powerled

System 350 A350R Electronic Temperature Reset Control (with Relay)

Temperature Controller USER S MANUAL

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Transcription:

p 7EM Temperature ontrollers ADVANTAGE EZ Series 7EM 1/8 DIN Temperature ontroller ontrollers Dual 3 Digit LED Display Input (T/, RTD) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol Up to 3 Outputs Up to 2 Independent Alarms onfigurable with Automatic or Manual Reset ontrol Output Disable Function The Advantage EZ 7EM 1/8 DIN ontrollers are configurable autotuning controllers for applications where input ranges do not exceed 999. Optional Features 24 Vac/Vdc Supply Heater Breakdown Input Two Temperature Alarms Heater Breakdown Alarm and Load urrent Display in Engineering Units Introduction The Barber-olman Series 7 establishes a new class of microprocessor based temperature controllers. As part of the Series 7 family, the 7EM offers outstanding performance features in a cost effective package. Designed specifically for equipment manufacturers who demand tight process control, the 7EM has a variety of standard features commonly found as options on our competitors controllers. NEMA 4X faceplates allow these units to be used in severe conditions. The 3 digit display offers complete coverage for extrusion and environmental chamber applications without excess cost for unused digits. The 7EM is easy to configure and use. Even operators without skills in temperature process control or knowledge of PID control parameters can obtain perfect control. For best results in control stability, simply: wire the instrument configure the setpoint and alarm thresholds initiate the autotune function

7EM Temperature ontrollers Specifications ontrollers ase: ABS black. Self-extinguishing degree V-0 according to UL, VDE and SA. Front Protection: Designed and tested for IP54 according to IE 529 and EI 70-1. Installation: Panel mounting by means of brackets. Rear Terminal Block: Up to 21 screw terminals, with safety rear cover. Dimensions: 48 x 96 mm (1.890 x 3.780 in.) according to DIN 43700; 89 mm (3.504 in.) deep. Weight: 400 grams maximum (1 pound). Power Supply (Switch Mode): - 100 to 240 Vac. 50/60 Hz (10% to -15% of the nominal value). - 24 Vac/Vdc. (±10% of the nominal value). Power onsumption: 11 VA. Insulation Resistance: Greater than 2 GΩ for 500 Vdc according to IE 348. Isolation Voltage: 1500 Vrms according to IE 348. D/A onversion: Dual slope integration. Noise Immunity: a)electrical fast transient/burst requirements: Severity Level 3 (according to IE 801-4). b)electric discharge requirements: Severity Level 8 (according to IE 801-2). Sampling Time: 500 ms. Accuracy: ±0.2% full scale span or ±1, @ 25 and nominal power supply voltage. ommon Mode Rejection Ratio: 120 db @ 50/60 Hz. Normal Mode Rejection Ratio: 60 db @ 50/60 Hz. Operating Temperature: From 0 to 50. Storage Temperature: From -20 to 70. Humidity: From 20% to 85% RH non-condensing. Protection: Internal jumper for configuration and calibration parameters. ontrol Action On/Off, PID or Smart AT Autotuning Special Function: Standby alarm sequence. Inputs (All inputs are factory calibrated and selectable from the keyboard.) Types: Thermocouples (J, K, L, N, T) or RTD Pt 100, keyboard configurable. Engineering Units: and F keyboard configurable. Reference Junction: Automatic compensation for an ambient temperature between 0 and 50. Line Impedance: 100 Ω maximum for T input. 20 Ω/wire maximum for RTD input. Reference Junction Drift: 0.1 /. Input Impedance: Greater than 1 MΩ. Sensor Break: Downscale or upscale programmable. On RTD inputs, an OVERRANGE is indicated when input resistance is less than 15 Ω (short circuit sensor detection.) alibration: According to IE 584-1 and DIN 43710-1977.

Specifications (continued) 7EM Temperature ontrollers Standard Ranges Input L J K N RTD Pt RTD Pt 100 100 Ranges 0 to 800 DIN 43710-1977 0 to 800 IE 584-1 0 to 999 IE 584-1 0 to 999 IE 584-1 -19.9 to 99.9 DIN 43760-199 to 500-199 to 999 F DIN 43760 ontrollers urrent Transformer Input for OUT 1 Heater Breakdown Detection (Optional) This feature allows measurement of the load current by means of a current transformer and signals an alarm condition when the current is below a pre-programmed threshold value. Input Range: Scaling: Resolution: Active Period: Minimum On Time to perform the measurement: 50 ms. Outputs 50 maac. onfigurable from 10 Amps to 100 Amps (with a 1 Amp step). - for full scale up to 20 Amps: 0.1 Amp. - for full scale from 21 Amps to 100 Amps: 1 Amp. - for relay output: or N configurable. - for SSR output: logic level 1 or 0 configurable. Main Output: (Heating) Relay or SSR (jumper selectable) - Relay SPDT, contact rating 3 Amps @ 250 Vac on resistive load. - Logic output for SSR, 700 Ω maximum load, short circuit protected. Logic Level 1: 14 Vdc ±20% @ 20 ma max. 24 Vdc ±20% @ 1 ma max. Logic Level 0: Less than 0.5 Vdc Output 2 (ooling or Alarm 1) Relay or SSR (jumper selectable) - Relay SPST, contact rating 2 Amp @ 250 Vac on resistive load. - Logic output for SSR, 700 Ω maximum load, short circuit protected. Logic Level 1: 14 Vdc ±20% @ 20 ma max. 24 Vdc ±20% @ 1 ma max. Logic Level 0: Less than 0.5 Vdc Output 3 (Alarm 2 or Heater breakdown) - Relay SPST, contact rating 2 Amp @ 250 Vac on resistive load. (normally open contact only)

7EM Temperature ontrollers Specifications (continued) ontrollers Alarms Alarm Functions: Type of Alarm: Alarm Hysteresis: Alarm Output: Process Alarm Deviation Alarm Band Alarm - High/Low (Outside/Inside for band alarm) - Direct/Reverse - Standby Sequence/No Standby Sequence 0.1 to 10.0% of input span or 1 least significant digit. Relay SPST 2 Amp @ 250 Vac resistive load. Display haracteristics Upper Display: Lower Display: Indicators: 3 digit 7 segment green LED display; 10 mm high. 3 digit 7 segment orange LED display; 7.6 mm high. 1 red LED when main (heating) output is ON. 1 red LED when cooling (or alarm 1) output is ON. 1 red LED when alarm 2 (or hbd alarm) output is ON. 1 red LED when Smart AT is enabled. Operator Interface Upper Display Shows the actual measured value or (during configuration) the value of the selected parameter. Lower Display Shows the operating setpoint; the heater current (in Amps); and the abbreviated name of the selected parameter. Keyboard Description Decreases the selected parameter. Increases the selected parameter. PV SV MAIN AL1 OOL AL2 HB AT Indicators MAIN Lit during the ON period of the heating cycle. AL1 OOL Lit when Alarm 1 is ON or during the ON period of the cooling cycle. AL2 HB AT Lit when Alarm 2 is in ON or when the heater breakdown alarm is ON. Flashes during startup autotuning. Lit steadily during adaptive autotuning. FUN Displays in sequence all parameters and saves new settings or displays the output level and heater current. FUN + Starts the default parameter loading procedure. AT + FUN Enables/disables the output power OFF function.

7EM Temperature ontrollers Wiring Rear Terminal Block 12 13 14 15 PWR LINE 100/240Vac 24 Vac/Vdc - SSR AL1/ + RTD 1 T 3 4 ontrollers 16 17 18 19 AL1/ - SSR MAIN + IN-T 5 6 7 8 20 21 MAIN AL2/HB 9 10 22 N 11 ontroller Wiring Power Line Wiring 12 13 6 Power Supply 100 to 240 Vac RMS or 24 Vac/Vdc TE: onnect neutral to terminal 12. Before connecting power to the instrument, make certain the line voltage corresponds to the model number. To avoid electric shock, connect the power line at the end of the wiring procedure. 24 Vdc supplies are not polarity sensitive. 7 urrent transformer Heater

7EM Temperature ontrollers Wiring (continued) Input Wiring Thermocouple Input Wiring ontrollers TE: Do not run input wires together with power cables. For T wiring use proper compensating cable, preferably shielded. If shielded cable is used, it should be grounded at one point only. 3 1 Shield Do not run RTD wires together with power cables. If shielded cable is used, it should be grounded at one point only. Use copper wires of the appropriate size (see "Specifications"). The resistance of the 3 wires must be the same. 3 1 Shield RTD RTD 4 3 1 4 3 1 RTD Input Wiring TE: Any external components (like zener diodes etc.) connected between sensor and input terminals may cause errors in measurement due to excessive or unbalanced line resistance, or possible leakage currents. Voltage Output for SSR Drive Logic voltage for SSR drive. Logic status 1: 24V +20% @ 1 ma 14 V +20% @ 20 ma Logic status 0: Less than 0.5 V OUT 1 (Main) 18 19 Solid State Relay TE: This output is not isolated. Isolation between instrument output and power supply must be assured by the external solid state relay. OUT 2 (Al 1/ool) 14 15 Solid State Relay

7EM Temperature ontrollers Wiring (continued) Relay Output Wiring The relay outputs are protected by a varistor. Refer to the specifications for contact ratings of individual relays. - OUT 1 20 OUT 1 (Main) OUT 2 (Al 1/ool) 21 22 16 17 - OUT 1 N - OUT 1 R LOAD R Power Line External Switch in Series with the Internal ontact ontrollers OUT 3 (Al 2/Hbd) 11 10 Inductive Loads High voltage transients may occur when switching inductive loads. These transients may introduce disturbances which can affect the performance of the instrument. The internal varistor assures protection up to 0.5 Amp of inductive component of the load. The same problem may occur when a switch is used in series with the internal contacts. In this case, it is recommended to install an additional R network across the external contact as shown. The value of capacitor () and resistor (R) are shown in the following table. Load urrent Less than 150 ma Less than 0.5 Amp Less than 1 Amp (uf) 0.1 0.33 0.47 R (W) 22 47 47 Resistor Power (W) 2 2 2 Resistor and apacitor Voltage 260 260 260 Relay output wiring must be as far away as possible from input or communication cables. See ontroller Mounting Dimensions at the end of this section.