Hazard Monitors. Hazard Monitor How monitor works Limitations. Acids turn paper red.

Similar documents
How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

The photoionization detector (PID) utilizes ultraviolet

Application Requirement

Lecture 35: Atmosphere in Furnaces

Mechanical Systems Competency 1.20

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Gamma and X-Ray Detection

Chapter 16: Tests for ions and gases

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

ABSTRACT INTRODUCTION

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

Introduction to Geiger Counters

Structure and Properties of Atoms

ph Measurement and Control

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

2. John Dalton did his research work in which of the following countries? a. France b. Greece c. Russia d. England

Coating Technology: Evaporation Vs Sputtering

3 - Atomic Absorption Spectroscopy

Hazmat Materials Training Fact Sheet Module 2 Classification. The classification of hazardous materials is based on three key factors:

Molar Mass of Butane

Elements, Atoms & Ions

Nitrogen Blanketing for Methanol Storage and Transportation

Selecting Gas Detectors For Confined Space Entry By H. Ross Humphry Canadian Safety Equipment Inc.

Measurement by Ion Selective Electrodes

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Noble Gases. Outline Nobel Gas Elements Radon and Health Chemistry Homework

Operating principle and construction of zirconium dioxide oxygen sensors of the XYA series

Inferred ph in Steam Plant Water Chemistry Monitoring

Fractional Distillation and Gas Chromatography

Coimisiún na Scrúduithe Stáit State Examinations Commission

A n = 2 to n = 1. B n = 3 to n = 1. C n = 4 to n = 2. D n = 5 to n = 2

TABLE OF CONTENT

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

EXAMPLE EXERCISE 4.1 Change of Physical State

User Guide Dissolved Oxygen Probes

This article provides a basic primer on an

Natural Gas Emergencies

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

The Electrical Control of Chemical Reactions E3-1

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Chapter 7: Chemical Energy

ATOMS AND BONDS. Bonds

DOT 126F Hazardous Material Awareness. Oregon State University Environmental Health and Safety

Chapter 5 - Aircraft Welding

Untitled Document. 1. Which of the following best describes an atom? 4. Which statement best describes the density of an atom s nucleus?

Question Bank Electrolysis

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Leak detection of systems

ALTAIR 5X Multigas Detector Bid Specification

A Potentiometric Analysis of Fluoride Ion in Toothpaste

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Paper Chromatography: Separation and Identification of Five Metal Cations

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

Santa Monica College Chemistry 11

Desalination of Sea Water E7-1

Properties and Classifications of Matter

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

ALS TRIBOLOGY Engine Coolant Reference Guide

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Experiment 12- Classification of Matter Experiment

Balancing chemical reaction equations (stoichiometry)

General Confined Space Awareness

The selection and use of flammable gas detectors

7.4. Using the Bohr Theory KNOW? Using the Bohr Theory to Describe Atoms and Ions

Generation of Vapor-Phase Hydrogen Peroxide Test Atmospheres for the Evaluation of Respirator Cartridges and Air Samplers

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

PortaSens ll G AS DETECTOR

Safety data sheet for product

The following document contains information on Cypress products.

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Electron Beam and Sputter Deposition Choosing Process Parameters

Handling and Storage of Flammable Materials at the Work Site

FIRST GRADE CHEMISTRY

Compressed Gas Cylinder Safety

Certain specific properties of compressed gases make them highly useful in various research activities.

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

BUSINESS LICENSE (2014) CHARTER TOWNSHIP OF FLINT 1490 S. DYE ROAD, FLINT Ml (810) OR FAX (810)

Fire Event Electronic and Mechanical System Damage Mechanisms Is Acid Gas for Real?

Reaction of Potassium Permanganate and Glycerin.

2014 Spring CHEM101 Ch1-2 Review Worksheet Modified by Dr. Cheng-Yu Lai,

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Technical Guidance. Application of Portable Gas Detectors in the Petrochemical Industry. Made simple. Introduction

Chapter 5 TEST: The Periodic Table name

Hydrogen Detection in Oil Refineries

Research on the Transport and Chemistry of Fission Products in Primary Circuit and Containment Conditions at VTT

Compressed Gas Cylinder Storage and Handling Guide

Process gases for analytical applications

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

THE DETECTION OF GREENHOUSE GASES

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Application Note AN1

Specimen Paper. Chemistry 1F. Time allowed! 60 minutes

23 The Thermal Conductivity Detector

Chapter 2: Forms of Energy

Chapter 13: Electrochemistry. Electrochemistry. The study of the interchange of chemical and electrical energy.

Handling and Storage of Flammable Materials at the Work Site

Vincenzo Esposito. Università di Roma Tor Vergata

Transcription:

Hazard Monitors Hazard Monitor How monitor works Limitations Corrosivity ph paper Dip pre-moistened ph paper into the sample. Use requires good color perception. Acids turn paper red. Contamination with oil, mud, or some other opaque material Bases turn paper blue. is possible. ph paper does NOT tell the specific concentration of the material. Use requires close contact with the material being sampled. Reading the paper is difficult when sampling highly concentrated acids or bases, unless solutions are diluted. ph meter Insert the probe into the material. Oils, temperature, or other contaminants may affect readings. Flammability ph is displayed on the meter s display. %LEL CGI Monitor has a catalytic filament sensor. Meter reading is the difference between the temperatures of the two filaments. %GAS CGI Monitor has a thermal conductivity (TC) filament sensor. Meter reading shows how cool the TC filament gets compared to the hot compensating filament. ppm-range CGI Monitor measures gas concentration in parts per million (ppm). Readings are read relative to the calibrant gas. Response curves or conversion factors may be required. A minimum concentration of oxygen is required. Monitor may be susceptible to catalyst poisons. Concentrations exceeding the UEL may create false readings. Sensors may be affected by chlorinated hydrocarbons. Sensors may become explosion hazards with oxygenacetylene mixtures. Meters made by different manufacturers and of different ages may act differently. Gases which cool the filament BETTER than the calibrant will indicate a higher %gas reading than is actually present. Gases which cool the filament WORSE than the calibrant will indicate a lower %gas reading than is actually present. All gases that cool the filament will create a meter response, even if they are not flammable. Sensitivity to detect and reliably measure ppm concentrations depends on the type of sensor employed and the calibrant. Long warm-up times are required. Page 1 of 5

Flammability All CGIs All CGI s depend upon a battery supply. Corrosive gases can deteriorate filaments. Hot vapors and gases may condense onto the inner surface of the cooler hose. Recommended operating temperatures are typically between 32 and 104 F (0 to 40 C). Magnetic fields, high voltage wires, static electricity, radios, and cellular telephones can interfere with readouts. Oxygen deficiency Radioactivity Oxygen monitor Monitor operates by diffusion. The air sample is drawn in by either a passive sensor or a battery-operated or bulb-operated pump. Oxygen reacts with electrolytes on the sensor, which generates a current flow to the meter. This current is amplified and displayed as percent-by-volume oxygen between 0% and 25%. Gas-filled detector Contains a gas such as air, nitrogen, helium, or argon. Radiation interacts with the gas and produces ions. A positively charged electrode or anode collects negatively charged ions, while the negatively charged cathode collects positive ions. Geiger-Mueller counter Monitor responds to X rays, gamma rays, and beta radiation. Liquids and particulates may disable the sensors. There is no indication of what type of gas may be displacing the oxygen. There is no indication of the toxicity of the gas displacing the oxygen. High concentrations of acid gases can quickly neutralize the electrolyte, causing rapid sensor failure. Strong oxidants will indicate a high or normal level of oxygen (false positive). Sensing units deteriorate over time and must be changed. Changes in humidity, temperature, and atmospheric pressure affect the monitor. Extreme cold may result in sluggish, delayed movement of the meter. Monitor requires a recovery time of 10-4 or 10-3 seconds after each pulse or ionization event. Over time, the counter may become saturated and no counts will be recorded. The meter will then display a zero-reading no matter what amount of radiation is present. Monitor is designed for nuclear attack emergencies, which pose radiological hazards much different from those of transportation or fixed site accidents. Alpha or low-energy beta radiation cannot be detected. Page 2 of 5

Radioactivity Ionization chamber Measures the ionization current flow in air between two electrodes. Monitor responds to beta rays, X rays, and gamma radiation. Those detectors with a thin covering over the chamber may also detect alpha radiation. Proportional counter Light-emitting detector Scintillation detector Luminescent detector A gas-filled chamber has a central wire that acts as a high-voltage anode. The inner conducting surface of the chamber acts as the cathode. The amplitude of the pulse peak equals the amount of energy absorbed by the gas. Monitor can be used to measure alpha and neutron radiation, as well as to identify specific radionuclides. Detector contains solid, liquid, or gas phosphors such as zinc sulfide, sodium iodide, or cesium iodide crystals. The light created when radiation strikes the phosphors is proportional to the radiation energy absorbed. Detector uses solids such as metaphosphate glass, calcium fluoride, and lithium fluoride that store radiation energy. When processed, these solids emit a quantity of light proportional to the original amount of radiation energy. Radiation dosimeter Film badge Badge consists of a small piece of photographic film wrapped in a light-tight cover and supported with a metal backing. Radiation interacts with silver ions on the film. The more radiation the badge is exposed to, the darker the film becomes. Pocket dosimeter Dosimeter measures X rays and gamma radiation. The unit consists of a quartz fiber, a scale, a lens to observe fiber movement across the scale, and an ionization chamber. Monitor requires that the voltage is carefully maintained. Frequent charging is required. Some dosimeters display a reading as soon as the unit is removed from the charger. The unit leaks small amounts of stored charge, causing the quartz fiber to drift and show a radiation reading. Page 3 of 5

Radioactivity Personal alarm The unit has visible and audible alarms and responds to any radiation over a preset level, usually between 1.0 and 2.5 mr/hr. The unit can respond to alpha, beta, X ray, and Toxic levels Photoionization detector (PID) Flame ionization detector (FID) gamma radiation. Instrument is effective for measuring low concentrations of materials. Monitor uses a hydrogen-fed flame to burn organic materials present in the air. The flame has enough energy to ionize any organic material with an IP of 15.4 or less. To be detected, the organic material must have multiple carbon-hydrogen bonds or multiple carboncarbon bonds. Some FIDs have an additional mode, called the gas chromatography (GC) mode. In this case: The sample is drawn into a column containing a carrier gas, usually a high-purity inert gas such as nitrogen or helium. Within the column, the individual components of the sample are separated. These separated components are represented as peaks on the recorder. Page 4 of 5 Detector s ability to work depends entirely upon the transmission of UV light. Many factors can alter light and thus affect the PID s ability to do its job: water vapor (humidity) non-ionizable gases and vapors lamp condition dust and particulates heated atmospheres corrosive gases high concentrations of gases and vapors A meter reading of 0 ppm does NOT necessarily mean that no contaminant is present PIDs cannot detect all potential contaminants present. The meter reading is NOT the actual concentration of contaminants present in ppm. PIDs do not respond to methane; however, methane will significantly decrease meter response to other ionizable contaminants. Meter readings may change when gases are mixed. Monitor requires oxygen in order to burn. Some FIDs do not have flame-out alerts to notify the user that the flame has gone out. Not all FIDs are intrinsically safe. Non-intrinsically safe FIDs are a source of ignition when flammable gases or vapors are present. Large concentrations of flammable gases may also: serve as an additional fuel source for the hydrogen flame, causing an increase in flame size and ion production, followed by an automatic, momentary shutoff of the hydrogen supply; this results in a meter reading of 0 produce oxygen deficiency The recommended minimum operating temperatures range from 40 to 50 F (5 to 10 C).

Toxic levels Colorimetric indicator tubes, (detector tubes) Electrochemical sensor chemical monitor Test strips and papers Each tube is a hermetically sealed glass tube containing an inert material, such as silica gel, alumina, resin, pumice, or ground glass. The inert material is mixed with one or more reagents. Reagents are usually specific to a particular type or class of chemical. Detector tubes, filled with reactive chemicals, are affected by any condition that would affect a chemical reaction, including: temperature humidity atmospheric pressure light time interfering gases or vapors There is a potential for cross-reactivity and false positives. Detector tubes have a margin of error of up to 35%. Response times may vary greatly from chemical to chemical. Responders with impaired color vision should NOT use detector tubes. Monitor measures a variety of specific toxic gases. If a chemical monitor uses a single toxic sensor, it will not indicate oxygen deficiency/enrichment or flammability. Test strips are available for specific hazards. They are usually part of a HazMat identification system. Page 5 of 5