HP Embedded SATA RAID Controller

Similar documents
HP Embedded SATA RAID Controller

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

HP Thin Client Imaging Tool

RAID 1(+0): breaking mirrors and rebuilding drives

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers

USER S GUIDE ADAPTEC EMBEDDED SERIAL ATA RAID

Backup and Recovery User Guide

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

SBI-7125B-T1 Blade Module RAID Setup Procedure

This user guide describes features that are common to most models. Some features may not be available on your computer.

HP ProtectTools Embedded Security Guide

Installing Microsoft Windows

Software Update, Backup, and Recovery

Intel Matrix Storage Console

Configuring ThinkServer RAID 100 on the TS140 and TS440

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

HP RDX Continuous Data Protection Software Quickstart Guide

HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number


HP Array Configuration Utility User Guide

RAID 1(+0): breaking mirrors and rebuilding drives

Backup and Recovery User Guide

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

WHITE PAPER. HP Guide to System Recovery and Restore

How To Use A Raid

Computer Setup User Guide

Getting Started. rp5800, rp5700 and rp3000 Models

RAID Option Installation

Promise FastTrak 100-Lite RAID Controller

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

Backing up and restoring HP Systems Insight Manager 6.0 or greater data files in a Windows environment

Configuring ThinkServer RAID 100 on the Lenovo TS130

Intel Rapid Start Technology (FFS) Guide

This user guide describes features that are common to most models. Some features may not be available on your computer.

Backup and Recovery User Guide

Using ATI Array Management Software (WebPAM)

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

RAID configuration and driver installation guide

HP Smart Array B110i SATA RAID Controller User Guide

Intel Rapid Storage Technology

Using Integrated and Discrete Graphics Simultaneously

DESKTOP. Internal Drive Installation Guide

HP ProLiant ML110 Server Network Operating System Installation Guide

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

Guide to SATA Hard Disks Installation and RAID Configuration

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Intel Matrix Storage Manager 8.x

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

Secure Perfect RAID Recovery Instructions

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

Remote PC Guide Series - Volume 2b

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

HP VMware ESXi 5.0 and Updates Getting Started Guide

HP Factory-Installed Operating System Software for Microsoft Windows Small Business Server 2003 R2 User Guide

Encore SATA2 RAID PCIe Card

This user guide describes features that are common to most models. Some features may not be available on your computer.

Remote PC Guide Series - Volume 2a

RAID Technology Overview

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Serial ATA RAID PCI. User's Manual

HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7

HP Online ROM Flash. User Guide

RAID installation guide

Setting up SATA RAID on the HP xw4600, xw6600, and xw8600 Workstations

Guide to SATA Hard Disks Installation and RAID Configuration

Image Backup and Recovery Procedures

Cloning Utility for VersaView Industrial Computers

AMD RAID Installation Guide

How to use Data Protector 6.0 or 6.10 with Exchange Recovery Storage Groups to restore a single mailbox

Getting Started. HP Retail Systems

HP Device Manager 4.6

RAID EzAssist Configuration Utility Quick Configuration Guide

Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1

Aberdeen AberNAS 110 RAID Recovery Technical Brief

BrightStor ARCserve Backup for Windows

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

HP Velocity Live QoS Support

Sharing Pictures, Music, and Videos on Windows Media Center Extender

Quick Start to Evaluating. HP t5630w, HP t5730w, HP gt7720

Smart Array technology: advantages of battery-backed cache

SATARAID5 Serial ATA RAID5 Management Software

RAID 5 rebuild performance in ProLiant

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

HP ilo mobile app for Android

Using HP ProLiant Network Teaming Software with Microsoft Windows Server 2008 Hyper-V or with Microsoft Windows Server 2008 R2 Hyper-V

GPT hard Disk Drives. For HP Desktops. Abstract. Why GPT? April Table of Contents:

Guide to SATA Hard Disks Installation and RAID Configuration

HP Access Control Express Installation Guide

How To Use The Enhanced Write Filter On Windows Xp Embedded (Dota) With A Powerbook (Dot) And Powerbook 2 (Windows Xp) With An Overlay (Powerbook) With The Write Filter (Wfmgr) On A

VIA / JMicron RAID Installation Guide

Windows 7 XP Mode for HP Business PCs

Creating and Restoring Images on the HP Thin Client with Altiris Deployment Server v6.5

Transcription:

HP Embedded SATA RAID Controller User Guide Part number: 391679-002 Second Edition: August 2005

Legal notices Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Part number: 391679-002 Second Edition: August 2005 Abstract This guide provides reference information for using the HP Embedded SATA RAID Controller to configure SATA drive arrays. Audience assumptions This guide is for the person who installs, administers, and troubleshoots servers. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. 2

Contents Controller features Installing the driver... 4 Configuring an array Using the RAID Configuration Utility... 5 Creating an array... 5 Managing arrays... 6 Adding or deleting a hotspare... 7 Configuring a drive... 7 Rebuilding an array... 7 Verifying drives... 8 Controller features 3

Controller features The HP Embedded SATA RAID Controller enables you to create arrays with RAID levels 0 and 1 on SATA hard drives in specified HP ProLiant server models. For a complete list of the controller attributes and information about the compatibility of particular operating systems with the controller, refer to the HP website (http://www.hp.com). Installing the driver A link to the downloadable driver for the controller is provided on the controller-specific page of the HP website, http://www.hp.com. Installation instructions are provided with the driver. Controller features 4

Configuring an array Two utilities are provided to enable you to configure arrays on the controller: The menu-based RAID Configuration Utility, located on the controller BIOS, enables you to configure an array even before the driver or operating system is installed. However, this utility can be opened and used only while the system is rebooting, before any installed operating system is loaded. Also, you cannot change the properties of an existing array using this tool. The rest of this guide describes how to use this tool. The GUI-based HP Storage Manager is provided on the HP website as an executable file that you install after you have installed the driver and operating system. This utility enables you to create new arrays and change the properties of an existing array. You can use this utility at any convenient time after the system has booted and the operating system has loaded. For detailed information about using this tool, refer to the separate HP Storage Manager User Guide provided with the utility. Using the RAID Configuration Utility The RAID Configuration Utility is loaded on the controller ROM. To run the utility, press the Ctrl+A keys or the F8 key (depending on the version of the ROM) when prompted by the following message during system startup: or Press <Ctrl><A> for Adaptec RAID Configuration Utility Press <F8> for HP Embedded SATA Setup To select an option from any of the menus within the RAID Configuration Utility, browse with the arrow keys, and then press the Enter key. In some cases, selecting an option displays another menu. To return to the previous menu at any time, press the Esc key. The main option on the RAID Configuration Utility menu is the array configuration utility, which enables you to: Create an array Manage an array Add or delete a hotspare Configure a drive Rebuild an array Verify drives The procedures for performing each of these tasks are described in the following sections. Creating an array Before creating an array, be sure that the drives to be used for the array are installed in your system and have been configured (on page 8). If the utility displays a drive in gray, the drive does not have any usable space, and it cannot be used to create an array. CAUTION: Before adding a drive to an array, back up any data on the drive. Otherwise, the data will be lost. To create an array: 1. Power down the computer, and then restart it. 2. When the appropriate prompt appears during POST, press the Ctrl+A keys or the F8 key to access the RAID Configuration Utility. 3. From the menu, select Array Configuration Utility. 4. From the array configuration utility menu, select Create Array. 5. Highlight a drive to be used in the new array, and then press the Insert key. 6. Repeat the previous step to select a second drive. (To deselect a drive, highlight the drive and press the Delete key.) 7. Press the Enter key when both drives for the new array are selected. Configuring an array 5

The Array Properties menu appears, showing the RAID levels (types of array) that can be configured for the selected number of drives. (For this controller, RAID 0 and RAID 1 are shown. Both of these RAID levels require two drives.) 8. Select the RAID level that you want to create, and press the Enter key. 9. (Optional) Enter a label of no more than 15 characters to identify the array. 10. If you are creating a RAID 0 array, select the stripe size that you want the array to use. Available stripe sizes are 16, 32, and 64 KB (the default setting). 11. Select one of the options listed under the Create Using heading to determine the method that the controller is to use to build the array. Table 1 describes typical circumstances for which each method is appropriate. CAUTION: Do not interrupt the creation of a RAID 0 array using the Migrate method. If you do, there is no way to restart the array creation or to recover the data that was on the source drive. CAUTION: Do not use the Migrate or Build methods to create an array on Microsoft Windows dynamic disks (volumes). These methods cause data loss in this case. Table 1 Choosing a method for creating the array RAID level Method Method is appropriate for 0 No Init Creating a RAID 0 array on new drives. 0 Migrate Creating a RAID 0 array when you want to preserve data on an existing drive. If you select this option, you are asked to designate the source drive. The contents of the source drive are preserved and any data on the new drive is lost. 1 Build Creating a RAID 1 array when you want to preserve data on an existing drive. If you select this option, you are asked to designate the source drive. The contents of the source drive are preserved and any data on the new drive is lost. 1 Clear Creating a RAID 1 array on new drives, or when you want to be sure that the new array contains no existing data. 1 Quick Init Creating a RAID 1 array on new drives. This is the fastest way to create a RAID 1 array. NOTE: If you pause a Build or Clear process on a RAID 1 array, you can restart the process by pressing the Ctrl+R keys. A RAID 1 array created using the Quick Init option might return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern. You can use drives of different sizes in a RAID 1 array. However, during a Build operation, only the smaller drive can be selected as the source drive. When migrating from single volume to a RAID 0 array, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must have at least half the capacity of the source drive. 12. Click Done. Managing arrays With the Manage Arrays option, you can: View array properties Make an array bootable Delete an array Viewing array properties 1. From the main menu of the array configuration utility, select Manage Arrays, and press the Enter key. 2. From the List of Arrays dialog box, select the array whose properties you want to view, and press the Enter key. The Array Properties dialog box appears, showing detailed information about the array. The physical disks associated with the array appear here. Configuring an array 6

NOTE: A maximum of two physical drives are supported per RAID set. The controller is capable of supporting multiple RAID sets. 3. Press the Esc key to return to the previous menu. Making an array bootable 1. From the main menu of the array configuration utility, select Manage Arrays, and press the Enter key. 2. From the List of Arrays, select the array that you want to make bootable, and press the Ctrl+B keys. An asterisk appears next to the array to indicate that it is bootable. To make an array nonbootable, select the array and press the Ctrl+B keys. Deleting an array CAUTION: Before you delete an array, back up any important data on the array. Otherwise, the data will be lost. Deleted arrays cannot be restored. 1. From the main menu of the array configuration utility, select Manage Arrays, and press the Enter key. 2. Select the array that you want to delete and press the Delete key. 3. In the Array Properties dialog box, select Delete, and press the Enter key. The following prompt appears: Warning!! Deleting the array will render the array unusable. Do you want to delete the array? (Yes/No): 4. Enter Yes. The following prompt appears: To delete the partition table, choose which member: member #0, member #1, both, none 5. Select the member to be deleted. 6. Press the Esc key to return to the previous menu. Adding or deleting a hotspare 1. From the main menu of the array configuration utility, select Add/Delete Hotspares 2. Use the arrow keys to highlight the drive that you want to assign as a hotspare, and press the Insert key. 3. Press the Enter key. The following prompt appears: Do you want to create spare? (Yes/No) 4. Enter Yes. The spare that you have selected appears in the Selected Drive menu. Configuring a drive CAUTION: If you configure a drive that is already part of an array, the array might become unusable. Do not configure a drive that is part of a boot array. To determine which drives are associated with a particular array, refer to on page 5. 1. From the main menu of the array configuration utility, select Configure Drives. 2. Use the arrow keys to highlight the drive that you want to configure, and press the Insert key. 3. If you want to add another drive to be configured, repeat the previous step. 4. Press the Enter key. 5. Read the warning message, and confirm that you have selected the correct drives to configure. 6. Press the Y key to continue. Rebuilding an array If a drive in a fault-tolerant (RAID 1) array fails, you can return the array to optimal status by performing a rebuild. There are two ways to perform a rebuild: Shut down the system, replace the failed drive, and begin the rebuild at the next system restart. Add a hotspare to the array if necessary, and select the array for a manual rebuild. Configuring an array 7

System shutdown rebuild Manual rebuild 1. Power down the system. 2. Replace the failed drive with a new one of equal or greater capacity. 3. Restart the system. 4. At the appropriate prompt during POST, press the Ctrl+A keys or the F8 key to access the RAID Configuration Utility. 5. From the menu, select Array Configuration Utility. 6. From the main menu of the array configuration utility, select Add/Delete Hotspares. 7. Assign the new drive as a hotspare. This starts the Rebuild task. All the data from the good drive is copied to the new one, and the original RAID 1 array is re-created. IMPORTANT: If a hard drive in the array fails and the array does not have a hotspare, you must add a hotspare before you can rebuild the array. Refer to on page 5. 1. From the main menu of the array configuration utility, select Manage Arrays. 2. From the List of Arrays, select the array that you want to rebuild. 3. Press the Ctrl+R keys to begin the rebuild process. Verifying drives NOTE: The Verify Drives menu option is not available if the array has failed. If you are notified of a data mismatch during RAID 1 array creation by a Build operation, you can verify the drives to determine a possible cause of the mismatch. To verify the drives: 1. From the main menu of the array configuration utility, select Verify Drives. 2. Select the drives that you want to verify. 3. Press the Ctrl+S keys. When the Verify Drives operation is complete, you are notified of any errors found. Configuring an array 8