MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Similar documents
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Pressure switches for gas and air Pressure sensors

Assisted lift operated 2/2-way solenoid valves Type EV250B

Pressure Switch for gas and air

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

3/2-way Solenoid Valve, direct-acting, NC or NO

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Compact pressure switch Flameproof enclosure Ex d Model PCA

Fluxi 2000/TZ Turbine Gas Meter

HERZ-Thermal Actuators

4/2-Way Pneumatic Solenoid Valve

Digital inductive conductivity transmitter

Solenoid valves Type EVU

How To Use A Flowmeter

Solenoid valves 2/2-way direct-operated Type EV210A

How To Use A Corona Mdi 110

System 8. ü ( System 8

Proportional pressure regulators VPPE

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Electric Rotary Actuator - On/Off or programmable control actuator

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Plastic tube flowmeters Series PT/PS

Solenoid Valve Island Type 3965

Type 3353 Angle Seat Valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Butterfly Valves PN 6/10/16 for flanged connection

2/2 and 3/2 Way Size 6 Seat Valves

Butterfly valves BVG, BVGF, BVA, BVAF, BVH, BVHS, BVHM

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Vacuum drying oven for non-flammable solvents

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

VDL 53 - Vacuum drying oven for flammable solvents

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Pressure transmitter For general industrial applications Model A-10

4 Posiflow Proportional Solenoid Valves

Control- and feedback head for integrated mounting on Robolux valves Type 2036

VR46../VR86.. series COMPACT AUTOMATIC COMBINATION GAS CONTROLS APPLICATION. Contents PRODUCT HANDBOOK

T U R B I N E G A S M E T E R

Series description: Wilo-Star-Z

type V46, solenoid or pneumatic operated

Cable Plug acc. to DIN EN , Form A

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Liquid Level Limit Switch liquiphant T FTL 20

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

3/2-way pneumatic cartridge solenoid valve

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

RY2 miniature industrial relays

Flow switches Series AD/VH

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Centro-Matic Automatic Lubrication Systems System Controls

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

OPTIMASS 6000 Technical Datasheet

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

PRESSURE REDUCING VALVES

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

3/2-way Mini Solenoid Valve

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

J TB/TW Temperature limiter, temperature monitor

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Hydraulic Control Solutions

Electro-pneumatic control valves

Refrigeration Compressed Air Dryer Buran Ultrapulse

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Pluggable interface relays CR-P Pcb relays

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Load-sensing control block in mono and sandwich plate design

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

G1/4 Q8. Standard with biased position

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Series description: Wilo-Drain TC 40

On-off valves MS-EM/EE, MS series, NPT

Kompressoren. Adsorption Dryer AD

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Instruction Manual Differential Pressure Transmitter

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

MFP14, MFP14S and MFP14SS Automatic Pumps

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Mounting Instructions. Torque Transducer. A en

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

Transcription:

GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N 7.01 Max. operating pressure 3 mbar (36 kpa) Compact design High flow rates Low weight Low power consumption Modulating mode Adjustable outlet pressure up to 300 mbar (30 kpa) Other servo pressure regulator variants: - zero pressure - constant pressure Printed in Germany Edition 11.16 Nr. 240 417 1 8 Mountable accessories - Pressure switch - VPS Technical Description The DUNGS multiple actuator MBC...SE integrates filter, valves and servo pressure regulator in one compact unit: - Dirt trap: Microfilter - 2 Solenoid valves up to 3 mbar (36 kpa) to DIN EN 161 Class A Group 2, fast opening - Servo pressure regulator unit to DIN EN 88 Class A Group 2 - Outlet pressure: 0-300 mbar (0-30 kpa) - Precision regulation of outlet pressure - For optimal outlet pressure stability - Flanged joints with pipe threads to ISO 7/1 or NPT - Easy to install - Low weight The modular system permits individual solutions with valve proving system, min./ max. pressure switches and pressure limiters. High flow rates at low pressure differences. Application The servo pressure regulator permits optimal mixture formation in forced air burners and premix burners in conjunction with mechanical or electronic integrated gas-air regulation units; this applies to modulating and multi-stage floating operating mode. Suitable for gases of gas families 1,2,3 and other inert gaseous media. Approvals EC type test approval as per EC Gas Appliance Directive: MBC...SE CE-0085 BM 0345 EC type test approval as per EC Pressure Equipment Directive: MBC...SE CE0036 Approvals in other important gas consuming countries.

Functional Description Gas flow 1. If valves V1 and V2 are closed, chamber a is subjected to inlet pressure. 2. The min. pressure switch (option) is connected to chamber a via a boring. If the inlet pressure drops below the desired value set on the pressure switch, the switch opens in the direction of the gas burner control system. 3. After they are enabled by the gas burner control system, valves V1 and V2 open. Gas flow is released through chambers a and b. Functional description of the combined valve-regulator unit Valves V1 and V2 can be controlled electrically and separately. Each valve preloads its own compression spring when the plunger opens. When the two valves are open, a pressure pulse runs below the working diaphragm. The size of the pressure pulse changes as a factor of the variable restrictor position D. The outlet pressure p Br acts against the setting spring force via the servo diaphragm until a force equilibrium is attained. The opposite side of the servo diaphragm is subjected to ambient pressure p amb. Changes in the equilibrium of forces lead to a change in flow cross-section. The pressure under the working diaphragm re-adjusts itself. The regulator unit adapts the free valve cross-section to the new flow requirement. Schematic diagram MBC...SE/N M D S E R Working diaphragm Restrictor Servo diaphragm Setting spring for outlet pressure p Br Regulator disc 11 10 7 6 5 4 3 1 2 a p 1 R p Br M S b E a, b Pressure chambers in flow direction p 1 Inlet pressure p Br Burner pressure, outlet pressure Ambient pressure p amb D p Br intern Standard p amb p Br extern Option 16 13 9 8 15 14 12 17 Closing function If there is an interruption in power supply to the solenoids of valves V1 and V2, they are closed by the compression springs within <1s. 1 Pressure regulator unit 2 Regulator spring 3 Connecting flange 4 Micro-filter 5 Valve V1 6 Closing spring V1 7 Housing 8 Plunger V1 9 Solenoid V1 10 PCB 11 Electrical connection 12 Valve V2 13 Closing spring V2 14 Plunger V2 15 Solenoid V2 16 Solenoid housing 17 Adjustment: - Gas pressure p Br Pressure taps, gas train diagram MBC...SE/N 2 3 4 1 5 1, 2, 3, 4, 5 Screw plug G 1/8 2 8

Technical Data Nominal widths Flanges with pipe threads to ISO 7/1 (DIN 2999) Max. operating pressure Inlet pressure ranges Burner pressure ranges Media Ambient temperature Dirt trap device Pressure switch Servo pressure regulator Solenoid valve V1, V2 Measuring gas connection Voltage/frequency Electrical connection Rating/power consumption Switch-on duration Switching cycles Degree of protection Radio interference suppression MBC-300-SE MBC-700-SE MBC-1200-SE Rp 1/2, 3/4, 1, 1 1/4 Rp 1, 1 1/4, 1 1/2, 2 Rp 1, 1 1/4, 1 1/2, 2 and their combinations and their combinations and their combinations 3 mbar (36 kpa) S22/S82: p e = 15-3 mbar (1.5-36 kpa) S302: p e = 35-3 mbar (3.5-36 kpa) S02/N: p e = 15-100 mbar (1.5-10 kpa) S22: p Br : 4-20 mbar (0.4-2 kpa) S82: p Br : 5 - mbar (0.5-8 kpa) S302: p Br : 30-300 mbar (3-30 kpa) S02/N: p Br : 0 ± 2 mbar (0 ± 0.2 kpa) Gases of gas families 1, 2, 3 and other inert gaseous media -15 C up to +70 C (in LPG plants, do not operate MBC...SE below 0 C. Only suitable for gaseous LPG, liquid hydrocarbons destroy the seal materials) Micro-filter made of chopped-strand nonwoven fabric. Filter replaceable without removing fitting Types GW A5, NB A2, ÜB A2 as per DIN EN 1854 retrofitable. For further information refer to Data Sheets Pressure switch for DUNGS multiple actuators 5.03 and 5.12 Servo pressure regulator with adjustable burner pressure, as per DIN EN 88 Class A, Group 2 Versions for constant pressure and zero pressure available Valves as per DIN EN 161 Class A Group 2, fast-closing, fast-opening G 1/8 DIN ISO 228, at inlet and outlet flanges, on both sides downstream of filter, between V1 and V2, downstream of V2 (fitting pressure switch may partially exclude measuring gas connection) ~(AC) 50 - Hz 230 V -15 % +10 %, other voltages on request. Standard voltages: ~(AC) 100 V - 120 V, =(DC) 24 V - 28 V Plug-in connection as per DIN EN 175301-3 at ~ (AC) 230 V; +20 C: see type summary 100 % ED per hour (30 s on/off) IP 54 as per IEC 529 (EN 529) Interference level N Materials of gas-conveying parts Housing Diaphragms, seals Solenoid drive die-cast aluminium on NBR base steel, aluminium Installation position S22/S82/S302: Vertical with upright solenoid or horizontal with horizontal solenoid, as well as their spacers. S02/N: Vertical with upright solenoid 3 8

Mounting dimensions [mm] MBC-300/700-... c d c d g g e e a a f f b b MBC-1200-... e = space requirement for solenoid replacement 4 8

Type Version Order No. 230 VAC DN Rp Opening time Mounting dimensions [mm] a b c d e f g Solenoid No. Switching ops/h Weight [kg] MBC-300-SE S22 261 645 1/2-11/4 95 143 61 175 297 87 236 032/2P 3.6 MBC-300-SE S82 261 644 1/2-11/4 95 143 61 175 297 87 236 032/2P 3.6 MBC-300-SE S302 261 647 1/2-11/4 95 143 61 175 297 87 236 032/2P 3.6 MBC-300-N on request 1/2-11/4 95 143 61 175 297 87 236 032/2P 3.6 MBC-700-SE S22 261 646 126 176 187 310 114 267 042/2P 5.1 MBC-700-SE S82 261 652 126 176 187 310 114 267 042/2P 5.1 MBC-700-SE S302 261 648 126 176 187 310 114 267 042/2P 5.1 MBC-700-N on request 126 176 187 310 114 267 042/2P 5.1 MBC-1200-SE S22 245 623 204 281 96 328 530 161 424 052/P 16.8 MBC-1200-SE S82 243 408 204 281 96 328 530 161 424 052/P 16.8 MBC-1200-SE S302 243 409 204 281 96 328 530 161 424 052/P 16.8 MBC-700-... MBC-1200-... P max. [VA] for t = 3 s 120 1 200 P max. [VA] Operation 15 20 30 Flange for Rp/NPT Order No. Order No. Rp 1/2 Rp 3/4 Rp 1 Rp 1 1/4 222 341 222 342 222 001 240 506 Line socket 3 pole + PE 210 319 Rp 1 Rp 1 1/4 Rp 1 1/2 Rp 2 222 343 222 344 221 884 221 926 Adapter, pressure gauge flange set G1/2 Adapter GW A with G1/4 Adapter p Br Adapter GW A on flange 216 675 222 982 214 975 221 630 NPT 1/2 NPT 3/4 NPT 1 NPT 1 1/4 222 371 222 368 221 999 231 718 Flanges, plug-in connection and system accessories must be ordered separately. NPT 1 NPT 1 1/4 NPT 1 1/2 NPT 2 222 369 222 370 222 003 221 997 5 8

Volume flow pressure difference characteristics in steady state with microfilter. 3 300 200 150 100 50 40 30 Recommended operating range (Rp 3/4) (Rp 1/2) (Rp 1 & 1 1/4) 20 10 8 6 5 4 3 2 1 Basis + 15 C, 1013 mbar, trocken Based on + 15 C, 1013 mbar, dry Base + 15 C, 1013 mbar, sec Base + 15 C, 1013 mbar, secco 2 3 4 5 6 7 8 910 20 30 40 100 200 Vn [m 3/h] Luft / Air / Aria dv = 1,00 2 3 4 5 6 7 8 910 20 30 40 100 200 Vn [m 3/h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,65 6 8

Volume flow pressure difference characteristics in steady state with microfilter. MBC-700-... 3 300 200 150 100 50 40 30 20 Recommended operating range MBC-700-... (Rp 1 1/4) MBC-700-... (Rp 1) MBC-700-... (Rp 1 1/2 & 2) 10 8 6 5 4 3 2 1 Basis + 15 C, 1013 mbar, trocken Based on + 15 C, 1013 mbar, dry Base + 15 C, 1013 mbar, sec Base + 15 C, 1013 mbar, secco 2 3 4 5 6 7 8 910 20 30 40 100 200 Vn [m 3/h] Luft / Air / Aria dv = 1,00 300 350 2 3 4 5 6 7 8 910 20 30 40 100 200 Vn [m 3/h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,65 7 8

GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N Volume flow pressure difference characteristics in steady state with microfilter. MBC-1200-... Recommended operating range Basis + 15 C, 1013 mbar, trocken Based on + 15 C, 1013 mbar, dry Base + 15 C, 1013 mbar, sec Base + 15 C, 1013 mbar, secco f = V gas used = Air density Density of gas used V air x f Gas type Natural gas Town gas Liquid gas Air Density [kg/m 3 ] 0.81 0.58 2.08 1.24 dv 0.65 0.47 1.67 1.00 f 1.24 1.46 0.77 1.00 We reserve the right to make any changes in the interests of technical progress. Head Offices & Factory Karl Dungs GmbH & Co. KG Siemensstraße 6-10 D-736 Urbach, Germany Phone +49 (0)7181-4-0 Fax +49 (0)7181-4-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-732 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 8 8