Resistive capacitive voltage divider

Similar documents
Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

DS 600. A contact free flux gate based current measurement sensor 600A rms

Capacitor Voltage Transformer. Answers for energy.

Transformer Bushings for GIS

How To Build A Low Voltage Capacitor Lvcp

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Three-phase monitoring relay CM-PFE

Safety technique. Emergency stop module BO 5988 safemaster

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Unified requirements for systems with voltages above 1 kv up to 15 kv

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Quick Connect. quick - simple - efficient.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Medium voltage insulator

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

RM4TG20 three-phase network control relay RM4-T - range V

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Low and High Voltage Power Supplies

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Power transformers. Special transformers Railway

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Pluggable interface relays CR-P Pcb relays

Features. Picture. Specifications

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

EFC Frequency converters

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Keystone Network Isolator with ESD- and Lightning Protection

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Bourns Resistive Products

MNS is Switchgear System Technical Overview

INTERNATIONAL STANDARD

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Incubator with mechanical convection

Thermistor motor protection

Circulating Current Relay. Type IRXm

Instrument Transformers Application Guide

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Voltage Regulator SPAU 341 C. Product Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electronic overload relay EF19 and EF45

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

R.C.C.B. s two-pole LEXIC

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

User's Guide. True RMS Industrial Multimeter

Analog signal converters CC-E I/I Current / current isolators

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

F05D Meeting on Damped AC Voltage Testing

Power Capacitor Units for improved power quality

T Substation Maintenance and Commissioning Test Equipment

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

HERZ-Thermal Actuators

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electronic overload relay EF65, EF96 and EF146

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

COAX Cables Radio Frequency Cables

Adjustment functions for both span and shift have been incorporated

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

DS1 Diode-based transient-free capacitor switch

Guide to the electrical parameter classifications of IEC and IEC safety standards

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

J TB/TW Temperature limiter, temperature monitor

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

SURGE PROTECTIVE DEVICES

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Agilent 4338B Milliohm Meter

Separation of power and information technology cabling

Series 6000 Torque measured metal bellow coupling

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Testing of Power Transformers. Routine tests, Type tests and Special tests

5SV Residual Current Protective Devices

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

SMS 4 / SMS 5 safety mat Product information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Transcription:

Resistive capacitive voltage divider Outdoor operation Oil-paper insulated ROF (72 550) kv

General description Resistive capacitive voltage dividers type ROF ( RC divider ) are used in high voltage networks within the 72.5 550 kv range. They divide the primary voltage into a standardised, equivalent secondary voltage for meters, measuring and protection devices. The active part of the RC divider consists of a capacitor divider and a parallel connected resistor divider. The length of the active part extends along the entire insulator length, which results in an excellent linear voltage distribution. Both dividers are matched with each other and reflect the transient voltage signals from the high voltage side precisely on the low voltage side. Due to the internal structure, an RC divider can be used for various frequencies and to measure alternating and direct voltages. As the active part of the RC divider is hermetically sealed to the outside, an expansion bellows in the head section compensates volume changes in the impregnation oil due to temperature variations. The operating pressure can be visualised via a manometer or a bellows position indicator. To avoid field distortions, a shielding electrode is used in the divider head for voltage levels of 420 kv and above. The secondary elements are located in the generously designed terminal box. In addition to fine adjustment and fast overvoltage protection, the terminal box also includes equivalent burden parameters. The terminal box cover is opened laterally and is fixed to the terminal box. The transmission of the secondary voltage can be implemented either as analogue signal via a shielded measurement cable or as a digital signal via a fibre-optic cable. The RC dividers are normally factory calibrated and can be put directly into operation. Advantages of capacitive resistive voltage dividers n Ferroresonance-free and no saturation effects n Secondary output operates without problems under short-circuit or no-load conditions n AC accuracy class ±0.1% @ f N n Measurement of harmonics possible up to 1 MHz n Accuracy with harmonics up to 10 khz of ±0.2%

Highlights Linear voltage distribution High accuracy at frequencies up to 10 khz Simple measurement cable connection n The optimised arrangement of the R and C dividers across the entire insulator length results in excellent voltage distribution. n The RC divider shows a perfect performance under transient voltage loads and high pollution risk. n The homogeneous field distribution prevents the occurrence of external partial discharges. n The specially developed design of the active part with the resistor and capacitor components enables a very high measurement accuracy and stability up to the 200th harmonic of the rated system frequency. n At the same time, high accuracy and stability in voltage variation (linearity) is achieved, starting with just a few percent of U R up to the overvoltage factor. n The terminal box has a base with connection sockets. The specially prepared measurement cable can be connected here easily without opening the terminal box. n If the number of measurement cables is increased, an additional cable can be plugged into the next terminal. To do this, the prepared burden indicator must be switched off with a switch in the terminal box. The divider is then equalised and ready for operation again.

Design Primary connection Expansion bellows Composite insulator RC divider active part Possible options n Colour coated metal surfaces n Bellows position indicator Operating pressure indicator Terminal box with rating plate n 2 4 additional secondary side measurement outputs n Equivalent burden parameters, incl. measurement cable parameters in terminal box n Increased accuracy up to ±0.1% for DC voltages n Expanded frequency transmission range up to 10 khz Lifting lugs Main earth connection n Increased accuracy up to ±0.2% over complete frequency range n Digital measurement signal transmission via fibre-optic cable n Preparation for recalibration in case of secondary measurement system changes

Technical data 72 300 kv 362 550 kv B A E F D C Type ROF 72 123 145 170 245 362 420 550 Standard DIN / IEC / IEEE Highest voltage for equipment kv 72.5 123 145 170 245 362 420 550 Rated power-frequency withstand voltage kv 140 230 275 325 460 510 630 680 Rated lightning impulse withstand voltage kv 325 550 650 750 1050 1175 1425 1550 Frequency Hz 16.7 / 50 / 60 Accuracy class 0.1; 0.2; 0.5; 1.0; 3.0 Expanded frequency band Hz 15 10000 Burden R or R // C Burden range 100 kω Rated voltage factors VF 1.5 30 sec / 1.9 30 sec / 1.9 8 h Type ROF 72 123 145 170 245 362 420 550 Height of unit* A mm 1306 1606 1806 2006 2606 3371 3771 4571 Height to primary terminal* B mm 1186 1486 1686 1886 2486 3491 3891 4691 Depth of unit including terminal box C mm 724 724 724 724 724 724 724 724 Depth of unit base D mm 500 500 500 500 500 500 500 500 Width of unit base E mm 500 500 500 500 500 500 500 500 Distance between screw holes at base F mm 450 450 450 450 450 450 450 450 Min. creepage distance* mm 2420 3540 4280 5030 7260 9414 11720 14314 Approximate weight* kg 100 125 140 155 200 230 250 340 * with standard composite insulator, creepage distance 25 mm/kv

Global presence PFIFFNER Instrument Transformers Ltd 5042 Hirschthal Switzerland Phone +41 (0)62 7392828 Fax +41 (0)62 7392810 E-Mail sales@pmw.ch Internet www.pmw.ch PFIFFNER Transformatör A.S. 06750 Akyurt /Ankara Turkey Phone +90 (0)31 28475521 Fax +90 (0)31 28475421 E-Mail info@pfiffner.com.tr Internet www.pfiffner.com.tr PFIFFNER do Brasil Ltda 88307-740 Itajaí Brazil Phone +55 (0)47 33481700 Fax +55 (0)47 33481700 E-Mail pfiffner@pfiffner.com.br Internet www.pfiffner.com.br PFIFFNER Deutschland GmbH 25524 Itzehoe Germany Phone +49 (0)48 21408270 Fax +49 (0)48 214082729 E-Mail sales@pfiffner-messwandler.de Internet www.pfiffner-messwandler.de MGC Moser-Glaser AG 4303 Kaiseraugst Switzerland Phone +41 (0)61 4676111 Fax +41 (0)61 4676110 E-Mail info@mgc.ch Internet www.mgc.ch ALPHA Elektrotechnik AG 2560 Nidau Switzerland Phone +41 (0)32 3328700 Fax +41 (0)32 3312679 E-Mail mail@alpha-et.ch Internet www.alpha-et.ch This document has been drawn up with the utmost care. We cannot, however, guarantee that it is entirely complete, correct or up-to-date. Copyright PFIFFNER 2015.01 Subject to change without notice. HIGH VOLTAGE Manufacturer of INSTRUMENT transformers since 1927 MEDIUM VOLTAGE LOW VOLTAGE