CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.



Similar documents
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

CompactLogix Power Supplies Specifications

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Quick Connect. quick - simple - efficient.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Waveguide Access Point WGA631. Product Guide

Power Supplies 3. SDN-P DIN Rail Series

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RM4TG20 three-phase network control relay RM4-T - range V

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Safety technique. Emergency stop module BO 5988 safemaster

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Thyristor-controlled power supplies and battery chargers

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ACS-30-EU-EMDR-10-MOD

ADM1TE 5/30A DIN rail single phase two wire energy meter

38 Series - Relay interface modules A

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

E-STOP relays, safety gate monitors

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Thermistor motor protection

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MasterINTERFACE 39 Series - Relay interface modules

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

CQM1-SF200/CS1W-SF200

Model: DC-A2IO Advanced HVAC Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Relés e Contatores de Estado Sólido SIRIUS

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Problem / Solution. The problem:

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Rack mounted telephone- and leased line modem for industrial applications

Power Meter Series 700

38 Series - Relay interface modules A

Digital input modules

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

STRATO LED Drivers 70W, Single output

CONFIGURABLE SAFETY RELAYS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MasterINTERFACE 39 Series - Relay interface modules

Redundancy Module QUINT-DIODE/40

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Telephone- and leased line modem for industrial applications TD-36

R.C.C.B. s two-pole LEXIC

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

SURGE PROTECTIVE DEVICES

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Operating Manual UWAPS-TINY Series

CONFIGURABLE SAFETY RELAYS

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Rosemount 333 HART Tri-Loop

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Analog signal converters CC-E I/I Current / current isolators

NX safety stand-alone

Rosemount 333 HART Tri-Loop

User s Manual Before using the inverter, you need to read and save the safety instructions.

Voltage Regulator SPAU 341 C. Product Guide

Bulletin 150 SMC Flex Smart Motor Controller Specifications

3500/62 Process Variable Monitor

Smile. The All-In-One Heating Controller

Electronic overload relay EF19 and EF45

J TB/TW Temperature limiter, temperature monitor

Energy Management Energy Meter Type EM23 DIN

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

HERZ-Thermal Actuators

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

WD-AMX Water Detection Controllers

80 Series - Modular timers 16 A. Features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air damper actuators

SINEAX U553 Transducer for AC Voltage

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Transcription:

425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc

425 EUROCUBE A complete range of low cost solid state relays and analogue thyristor units for 15 to 125 amps and up to 500 volts. Works with many load types in single or three phase applications. 425S Solid State Relay The ideal replacement for mechanical contactors. Better temperature control - The short cycle times possible with solid state devices mean fine adjustment of the delivered power for better temperature control. No longer does the heater have to be on for almost a minute just to prolong contactor lifetime. Reduced maintenance costs - The solid state relay has no moving parts needing maintenance. Zero voltage switching means no arcing when switching, which eliminates deterioration and reduces interference to the supply. The 425S optionally detects partial load failure so maintenance can be scheduled at the best time rather than waiting for total failure and lost production. Increased element lifetime - The short power bursts from the solid state relay reduce temperature changes in the heating element; this in turn reduces thermo-mechanical stress. No longer do you need to see your elements cycle from dark to red hot and back again just to maintain a constant temperature. 425A Thyristor Unit A low cost thyristor unit with phase angle firing for inductive or variable resistance loads and burst firing for resistive loads and to improve power factor. Elimination of supply variations - The 425A senses the supply voltage delivered to the load. If the voltage varies then the unit responds immediately to prevent any temperature fluctuation. Heating element protection - With phase angle firing the 425A has an optional current limit. This is essential for elements with low cold resistance so that they can be heated without damage to elements or fuses. Designed for three phase control - A 425A and 425S connected together using slave output (425A) and 20mA or 10V input (425S) provide an option for controlling three phase loads. CE marking/safety - 425S and 425A units meet the essential requirements of the European Low Voltage Directive. No exposed parts are at a dangerous voltage. Eurotherm certifies that the 425S and 425A units when used with recommended filter have successfully passed the Electromagnetic Compatibility (EMC) tests and enables the system which incorporates them to comply with the EMC directive as far as the 425S and 425A are concerned. An EMC installation guide is available on request (part no. HA025464).

TECHNICAL SPECIFICATION 15A to 125A Voltage 120 V to 500 V (+10%, -15% of nominal voltage). 50/60 Hz. Auxiliary Supply 425A only; 100 to 240 V (+10%, -15%), 2.5VA (Plus 13VA for fan supply for 100A and 125A units) Storage Temperature -10 C to 70 C. Operating Temperature 0 C to 50 C with heat sink fins vertical. Cooling Natural convection up to 75A. Fan cooled with overtemperature sensor from 100A. Heat Dissipation 2 watts per amp including fuses. Environment 5 to 95% relative humidity, non-condensing, no conductive or corrosive dust, no explosive or flammable atmospheres. Maximum altitude 2000m. Mounting Panel, symmetrical and asymmetrical DIN rail using universal clips. Mounts on separate plate for easy removal. Fuses External fuse to protect thyristor unit only. Fuse and fuse holder are separate and fix to DIN rail. Control Terminals Cable size 0.5 to 2.5 mm 2. Terminals are detachable. Transient Protection Fitted internally Leakage Less than 30 milliamps. Enclosure Protection Rated to IP20 (IEC 529) Isolation Control signals isolated from power. Distances comply with the requirements of IEC 664. Safety 425S and 425A products comply with the Low Voltage Directive 73/23/EEC dated 19/2/73 amended by Directive 93/68/EEC dated 22/7/93. EN61010 installation category 3 (voltage transients must not exceed 4 0kV) EMC Standards Immunity EN50082-2, EN61000-4-2, EN61000-4-4, ENV 50140, ENV50141 Emissions EN50081-2, EN550011 - see individual 425S and 425A sections for filter requirements 425S Solid State Relay Load Type Load Configuration Constant resistance. Single phase line to line or line to neutral. Three phase, four wire star or six open delta - three units together. Three phase three wire star or delta - two units controlling two of the three limbs of the load. Input - Logic DC AC Input type 20mA 10V 24V 24V 48V 100 to 240V ON if greater than 5mA 8V 16V 20V 30V 90V OFF if less than 0.5mA 2V 2V 6V 10V 35V Maximum input 50mA 20V 32V 30V 55V 264V Approx input impedance 0 320R 1.6k 2k 3k 9.3k Note: each input is in series with each input is in series with 2 diodes, voltage drop less than 4 diodes, voltage drop 6.5 volts 3V at 20mA Firing Mode Zero voltage switching (synchronised to line). Partial Load Failure (PLF) Optional detection of load resistance increase of 15% to detect failure of one of up to six parallel heater elements. (DC Logic input only) The full firing current must be greater than 15% of nominal current if PLF is used. LED indication and opening or closing of alarm relay, Contact rating - 0.25 A (250 V A.C. or 30 V D.C.). EMC filters Meets IEC 1800-3 without filter. Meets EN50081-2 with internal filter (FILT option) for 75A to 125A (standard for 15A to 63A) 425A Thyristor Unit Load Type Resistive with fixed or variable resistance, short wave infra red elements, inductive. Load Configuration Single phase line to neutral or line to line with step down transformer for auxiliary supply. Three phase, four wire star or six wire open delta - three units together. Three phase, three wire star or delta - 425A and 425S in master slave configuration. Burst firing only. Input - Analogue DC voltage 0-5 V, 0-10 V, 1-5 V Input impedance >47k DC current 0-5 ma, 0-10 ma, 0-20 ma, 4-20 ma Input impedance <1k, 470R, 270R, 270R, range dependant Firing Mode Phase angle: Varies the thyristor firing angle. Fast cycle: Cycle time 320 milliseconds (at 50% power) Slow cycle: Cycle time 10 seconds (at 50% power) Single cycle: Cycle time 40 milliseconds (at 50% power) Voltage Feedback Supply voltage is sensed and firing angle or burst times are adjusted to maintain constant power. Limit Optional current limit available with phase angle firing. Adjustable threshold from 10% to 100% of nominal current. Only operates for currents above 2 amps. Manual Input 0-10 V, 330 K impedance. Unit controls to the sum of Auto and Manual Input. Input scale 0-5V or 1-5V Slave Output Suitable for driving the 20 ma input of one or two 425S slave units. EMC Filters Meets IEC 1800-3 without filter Meets EN 50081-2 when used with filters as shown below. Nominal Firing mode and Configuration current Phase angle Burst and Single cycle of the 425A Single phase Single-phase Three-phase (2 phase control) 15A to 63A External series filter, code: Internal filter Internal; filter (FILT option) FILTER/MON/63A/00 or (FILT option) 3 parallel filters, FILTER/MON/25A/00 ordering code: FILTER/PAR/TE10S/00 75A and 100A External series filter, code: Internal filter Internal filter (FILT option) FILTER/MON/100A/00 (FILT option) 3 parallel filters, 125A 2 external series filters in ordering code: parallel, filter code: FILTER/PAR/425S/00 FILTER/MON/100A/00

ORDERING CODE - 425S SOLID STATE RELAY Basic Product Voltage 425S Fan Supply Input Language Option End 00 15 amps 15A 25 amps 25A 40 amps 40A 63 amps 63A 75 amps 75A 100 amps * 100A 125 amps * 125A * Fan cooled (fan consumption 13 watts) Voltage 120 volts 120V 240 volts 240V 415 volts 415V 440 volts 440V 480 volts 480V 500 volts 500V Fan Supply No fan (up to 75 amps) 000 100 volts 100V 110V to 120 volts 110V120 200 volts 200V 220V to 240 volts 220V240 Input (Logic Signal) DC LGC AC ACL Language English ENG French FRA German GER Option Partial load failure (LGC input only) Relay open in alarm Relay closed in alarm Internal EMC filters for 75A to 125A (not required for lower currents) PLF IPF FILT Coding example: 425S solid state relay; Load current 17 A; Supply 380 V; No fan cooling; DC logic inputs; Partial load failure option (open in alarm): 425S/25A/415V/000/LGC/PLF/00 Note: External step down transformer required for fan supply when voltage is 415 V, 440 V, 480 V. ORDERING CODE- 425A ANALOGUE INPUT THYRISTOR UNIT Basic Product Voltage Auxiliary Supply Input Firing Mode Language Option End 425A 00 15 amps 15A 25 amps 25A 40 amps 40A 63 amps 63A 75 amps 75A 100 amps * 100A 125 amps * 125A * Fan cooled (fan consumption 13 watts) Voltage 120 volts 120V 240 volts 240V 440 volts 440V 480 volts 480V Input (Analogue Value) Volts 0-5 volts 0V5 1-5 volts 1V5 0-10 volts 0V10 0-5 milliamps 0mA5 0-10 milliamps 0mA10 0-20 milliamps 0mA20 4-20 milliamps 4mA20 Firing Mode Phase Angle PA Fast Cycle FC Single Cycle FC1 Slow Cycle SC Option Limit (Phase angle firing) Internal EMC filter (Burst and Single cycle firing modes) CL FILT Coding example: 425A phase angle thyristor unit; Load current 90 A; Supply 240 V; Auxiliary supply 100 V; Analogue input 0 to 10 V; limit option: 425A/100A/240V/100V/0V10/PA/CL/00 Note: External step down transformer required for auxiliary supply when voltage is 440 V, 480 V or 500V Auxiliary Supply 100 volts 100V 110V to 120 volts 110V120 200 volts 200V 220V to 240 volts 220V240 Language English French German ENG FRA GER

WIRING DETAILS Example of three-phase wiring for a 425A unit and for a 425S solid state contactor (up to 63A) L1 L2 L3 Cut-out device L1 L2 L1 L2 L1 L2 3 Parallel filters LA174935U001 FILTER/PAR/TE10S/00 Three-phase load Y or 0.5A Fuses External fuse External fuse 425A LINE LIGNE LOAD CHARGE 425S LINE LIGNE LOAD CHARGE N/L2 230V SUPPLY ALIM. 0V SLAVE INPUT ENTREE AUTO MANU 10 V Com INPUT ENTREE 20 ma = 10 V = 24 V = 600 400 400 230 425A Thyristor Unit 0 External Transformer N Auto Slave Input Output External Fuse - + Control Signal 425S Solid State Relay Common 20 ma 10V 24V External Fuse +10V Manual Input 0V Firing Circuit Firing Circuit Limit (option) PLF Supply P.L.F. (option) N/L2 230V Supply 115V Load MOUNTING AND DIMENSIONAL DETAILS PLF Alarm Output Load EUROTHERM 15A to 63A models The units are mounted by means of a base plate. Fixing clips are used when mounting on a symmetrical or asymmetrical DIN rail. Each unit is delivered with screws and a set of two fixing clips as standard (ref. EUROTHERM BD173730). Fixing clips DIN Rail Clip-on fixing Baseplate (fixing plate) M6 screw

75A to 125A models Each unit is mounted on two DIN rails by means of a base plate and three fixing clips (ref. EUROTHERM BD173730). EUROTHERM (mm) 15A 25A 40A 63A 75A 100A 125A Height 134 134 134 134 190 190 190 Width 98 98 116 116 117 117 117 Depth 94 130 155 155 190 190 190 Weight (Kg) 0.6 0.8 1.1 1.2 1.85 2.0 2.0 Max. Cable Size 6 mm 2 6 mm 2 *10 mm 2 *16 mm 2 35 mm 2 35 mm 2 35 mm 2 * Including adaptor DIN rail 85 mm ±10 12 mm±0,5 Clip-on fixing Fixing clips Baseplate (fixing plate) FUSE AND FUSEHOLDER DETAILS M6 screw Eurotherm recommended that a semi-conductor fuse be fitted with each thyristor unit or solid state relay. With the 425A and 425S these units must be ordered separately. A line protection or HRC fuse or suitably rated circuit breaker must be fitted for cable protection. The semiconductor fuse is only designed to protect the thyristor unit. Ordering codes - fuse and fuseholder Fuseholder End 00 Please note that replacement fuses are marked with a higher rating than the solid sate relays. This allows correct operation at elevated temperatures and does not imply that higher current is permissable. H a W b d c D Unit Fuseholder Spare Fuses 15 amps FU1038/16A CH260024 25 amps FU1038/25A CH260034 40 amps FU1451/40A CH330054 63 amps FU2258/63A CS173087U080 75 amps FU2258/75A CS173087U100 100 amps FU2760/100A CS173246U125 125 amps FU2760/125A CS173246U160 Fuse and fuseholder dimensions (mm) Fuseholder FU1038 FU1451 FU2258 FU2760 Height (H) 81 95 124 240 Width (W) 17.5 26 35 54 Depth (D) 68 86 90 107 a - 2 4 - b 7.5 7.5 - - c 38 45 54 71 d 36.5 40.5 42 75 EUROTHERM CONTROLS LIMITED http://www.eurotherm.co.uk UK SALES OFFICE Eurotherm Controls Ltd Faraday Close Durrington Worthing BN13 3PL United Kingdom Sales and support: Tel. +44 (0)1903 695888 Technical: Tel. +44 (0)1903 695777 Fax +44 (0)1903 695666 Sales and support in over 30 countries worldwide Enquiries/orders to: Eurotherm Controls Ltd Faraday Close Durrington Worthing BN13 3PL United Kingdom Tel. +44 (0)1903 268500 Fax +44 (0)1903 265982 Copyright Eurotherm Controls Limited 1994 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or omissions to this specification. We cannot accept responsibility for damage, injury loss or expenses resulting therefrom. Part No. HA023781 Issue 5 Printed in England 06.00