Cable Temperature Sensors

Similar documents
Flush-mount room temperature sensor AQR2531ANW.

Room Temperature Sensors

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RRV934. Multi-controller. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Air damper actuators

Digital input modules

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Flush-mounted room thermostats

Digital inductive conductivity transmitter

Capteur température et humidité pour HVAC

Incubator with mechanical convection

Series description: Wilo-Yonos MAXO-D

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Series description: Wilo-Yonos MAXO

HERZ-Thermal Actuators

Electronic Control Devices The European Product Catalogue 2007

Input module, input/output module

Thermostatic Actuators

ECOCIAT. Domestic hot water heat recovery unit

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Butterfly Valves PN 6/10/16 for flanged connection

Adjustable room thermostat for heating only or cooling only systems

Material test chamber with mechanical convection

SEISMIC VELOCITY TRANSDUCER T1-40

OZW30. Central Unit SYNERGYR

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Duct Humidity Transmitter

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Electronic Control Devices The European Product Catalogue 2007

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Portable digital microprocessor thermometers with interchangeable probes

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Heating oven with mechanical convection

TX OPEN RS232/485 module

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

A99B Series Temperature Sensors

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Open channel & partially filled pipe Ultrasonic flow meters

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

How To Use A Flowmeter

Electric Rotary Actuator - On/Off or programmable control actuator

Technical Information RIA14

Self-operated Temperature Regulators Temperature Regulator Type 1u

Operating Instructions for Plastic Flow Meter. Model: KSK

HVAC Sensors Catalogue

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

2- and 3-port valves with flanged connections, PN 10

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Thermostatic element RAVV for 2-way valves

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

TARIFF CODE and updates standard

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Pressure transmitter For general industrial applications Model A-10

Test equipment for temperature and its reduction

Rosemount 333 HART Tri-Loop

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

RTD Temperature Probe for the Food/Pharmaceutical Industry

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Stainless steel process fittings

Assisted lift operated 2/2-way solenoid valves Type EV250B

Solenoid valves Type EVU

Data sheet ECC 12 and 22

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Scraper Passage Indicator. Electrical Indicator. Features

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Digital display DA 48

Climate chamber with illumination

Threaded Resistance Thermometers Model TR10-D, Miniature Design

DEVIreg 330 (+5 to +45 C)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Rosemount 333 HART Tri-Loop

Model: DC-A2IO Advanced HVAC Controller

Heating oven with mechanical control

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

ATL Fuel Level Sender Probes

ACTIV-8 PLUS Insulated Conductor Bar

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Split Controller. User Manual SM-SS-F 2009/01/04

How To Control A Korean Korean Power Plant

Hand-held thermometer Model CTH7000

Inductive sensor NI10-M18-Y1X-H1141

Transcription:

1 831 1847P01 Cable Temperature Sensors QAP... Use The sensors are used in heating, ventilation and air conditioning plants to acquire the temperature. They are for use with the corresponding accessories as: strap-on sensors for pipework strap-on sensors for solar collectors immersion sensors Changeover (from heating to cooling or vice versa) Type summary Type reference Sensor element Cable length Material connecting cable Measuring range Weight (incl. packaging) QAP2010.150 Pt 100 1,5 m silicone -30 +130 C 0,05 kg QAP2012.150 Pt 1000 1,5 m silicone -30 +130 C 0,05 kg QAP21.3 LG-Ni 1000 1,5 m silicone -30 +130 C 0,05 kg QAP21.3/8000 LG-Ni 1000 8 m silicone -30 +130 C 0,23 kg QAP22 LG-Ni 1000 2 m PVC -25 + 95 C 0,06 kg QAP1030.200 NTC 10k 2 m PVC -25 + 95 C 0,06 kg CE1N1831en 2014-07-30 Building Technologies

Accessories Name Part number/ type reference Protection pocket, Ms63, PN10, immersion length 100 mm ALT-SB100 1) Cable holder for protection pocket mounting 4 213 1416 0 Changeover mounting kit For fitting on pipes (pipes of about 13...35 mm dia.), consisting of holding piece and cable ties (2x) Aluminium bar Consisting of bar with riveted holder and rubber grommet ARG22.1 2) ARG22.2 1) For other protection pocket accessories, refer to Data Sheet N1194. 2) Suited for max. 95 C. Use cable ties made of metal for temperatures above 95 C Ordering and delivery When ordering, please give type reference of sensor and part numbers / type reference of the accessories required. Example: Cable temperature sensor QAP2010.150. The cable temperature sensor is supplied without any mounting accessories. These must be ordered separately. Equipment combinations The cable temperature sensors are suited for use with all types of controllers that can handle the sensor s passive output signal. Function The sensor acquires the temperature via its sensing element. The resistance of the sensing element changes as a function of the ambient temperature. The resistance value is used for further handling by a suitable controller. Sensing elements LG-Ni 1000 Characteristic: Accuracy: [K] 1800 1801D01 1.5 1801D02 1600 1.0 1400 0.5 1200 1000 0.5 800 1.0 600 1.5 40 30 20 10 0 10 20 30 40 50 60 70 80 40 30 20 10 0 10 20 30 40 50 60 70 80 2/6

Pt 100 (class B) Characteristic: Accuracy: 160 1847D01 0.8 [K] 1847D02 140 0.4 120 100 0.4 80 40 30 20 10 0 10 20 30 40 50 60 70 80 0.8 40 30 20 10 0 10 20 30 40 50 60 70 80 Pt 1000 (class B) Characteristic: Accuracy: [K] 1600 1400 1847D05 5.0 4.0 3.0 2.0 1.0 1847D04 1200 1.0 1000 800 40 30 20 10 0 10 20 30 40 50 60 70 80 2.0 3.0 4.0 5.0 30 20 10 0 10 20 30 40 50 60 70 80 NTC 10k Characteristic: Accuracy 1000000 100000 10000 1000 100-30 -20-10 0 10 20 30 40 50 60 70 80 1847D09 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8 [K] -30-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 1847D08 [ C] Legend R Resistance in Ohm Temperature in degrees Celsius 3/5

Mechanical design The sensor consists of sleeve (40.5 mm in length), sensing element and 2-core connecting cable. The sensing element is encapsulated in the sleeve so that it is mechanically and electrically protected. The sleeve also ensures strain relief for the connecting cable. The end of the cable carries ferrules for easy connection. Different accessories are available for fixing the sensor. Engineering notes Mounting and installation notes The permissible cable lengths are dependent on the type of controller with which the sensor is used. They are specified in the Data Sheet of the relevant controller. The connecting cable should always be connected to a conduit box. When mounted in a protection pocket, the sensor must always be fixed in the pocket by means of the cable holder. Instructions for mounting in induction or fan coil units: The sensor should be fitted in the location specified by the manufacturer of the terminal unit. If there is no such specification, it must be fitted in the return air flow where it captures the temperature of the room air drawn in. It should be fitted as high as possible to minimize the floor effect. The sensor must be protected against heat radiation from the terminal unit. Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 4/6

Technical data Functional data Degree of protection Electrical connections Environmental conditions Environmental compatibility Materials Weight Measuring range Sensing element Time constant Sensor with ARG22.1 (attached to pipe) Sensor with protection pocket Sensor with ARG22.2 in air at v = 3 m/s approx. 25 s <30 s <1 min Measurement accuracy refer to "Function" Type of measurement and output passive Protection degree of housing IP65 according to EN 60529 Protection class III according to EN 60730-1 Connecting cable Cross-sectional area Length Perm. cable lengths Permissible ambient temperature for silicone cables for PVC cables 2-core, interchangeable 2 x 0.34 mm 2 see "Type summary" refer to "Engineering notes" 30...+140 C 25...+95 C, Short-time (2 h/d) +110 C Perm. ambient humidity 95 % r. h. The product environmental declaration CE1E1701 *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Sensor sleeve stainless steel 1.4571 (V4A) Connecting cables Packaging corrugated cardboard Incl. packaging *) The documents can be downloaded from http://siemens.com/bt/download. 5/5

Internal diagram 1847G01 The internal diagram is identical for all types of cable temperature sensors covered by this Data Sheet. The connecting wires are interchangeable. Dimensions Sensor QAP Protection pocket ALT-SB100 Changeover mounting kit for fitting on pipes ARG22.1 Aluminium bar ARG22.2 12 40,5 30 13 100 13 22 130 6,5 7 x 10 10 5 5,3 ø 6 1831M06 G½ A ø 9 1832M04 22 2 2 16 1831M05 Dimension in mm 6/6 2004 2014 Siemens Switzerland Ltd Subject to change