Dew Point in Compressed Air

Similar documents
How is Dew Point Measured Reliably?

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ThermoSorb Desiccant Dryers

Kompressoren. Adsorption Dryer AD

Basic Hydraulics and Pneumatics

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Adsorption air dryers ADS 1 215

ThermoStar Refrigeration Air Dryers

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Pressure Dew Point Probe / Application Information

Validation of process gas systems

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Cooking at the Speed of light!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

THE HUMIDITY/MOISTURE HANDBOOK

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Atlas Copco Quality Air Solutions. Compressed Air Filters

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Air Eliminators and Combination Air Eliminators Strainers

Temperature and Humidity

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Desiccant Air Dryers Heatless, Heated and Heated Blower

Kompressoren. Oil Water Separators OWS

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

ETC -SV. Class 0 oil-free compressed air through catalysis

COMBIMASS. Technical Data COMBIMASS eco-bio +

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Chemistry 13: States of Matter

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

HELPFUL HINTS ON PREPARING COMPRESSED AIR

Refrigeration Basics 101. By: Eric Nelson

Rotary screw compressors kw 5,5 7, , bar MODULO

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Dryaire Desiccant System

Medical Air Systems: Scroll

Pro Dry Heatless dessiccant compressed air dryers

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Compressed Air Filters

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

How do I measure the amount of water vapor in the air?

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

Nirvana. Cycling Refrigerated Dryers

Why and How we Use Capacity Control

Centrifugal Water Chillers. Scott Meyerkord

PBX Series Quick Fit Connector Bimetallic Steam Traps

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

NITROX // safer diving

Online Infrared Flue Gas Analyzer Gasboard 3000

Technical data. Danfoss DHP-A

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Open Cycle Refrigeration System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Compressed Gas Cylinder Program

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Element D Services Plumbing

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Fundamentals of Mass Flow Control

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Glossary of Heating, Ventilation and Air Conditioning Terms

In-Line Electronic Flow Switches

A/C refrigerant system, overview

Please keep these operating instructions in a safe place.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

In-Line Electronic Flow Switches

Instruction Manual. T3111 T3111L T3111P T3111Ex

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Refrigeration Air Dryers. Catalogue

Fiscal Measurement Natural Gas

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Refrigerated Air Dryers. Catalogue

CG PTFE Diaphragm Liquid Transfer Pump

Electronic Flow Switches

ARP Food Industry, Portugal

Recommended Compressor Installation Practices

Refrigeration Compressed Air Dryer Buran Ultrapulse

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Transcription:

Frequently Asked Questions

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FI-00421 Helsinki Finland Visit our Internet pages at www.vaisala.com Vaisala 2011 No part of this document may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this document in any form without the prior written consent of Vaisala is strictly prohibited. All specifications technical included are subject to change without notice.

Frequently Asked Questions 1. What is dew point? Dew point temperature is a measure of how much water vapor there is in a gas. Water has the property of being able to exist as a liquid, solid, or gas under a wide range of conditions. To understand the behavior of water vapor, it is first useful to consider the general behavior of gases. In any mixture of gases, the total pressure of the gas is the sum of the partial pressures of the component gases. This is Dalton s law and it is represented as follows: Ptotal = P1 + P2 + P3 The quantity of any gas in a mixture can be expressed as a pressure. The major components of air are nitrogen, oxygen, and water vapor, so total atmospheric pressure is composed of the partial pressures of these three gases. While nitrogen and oxygen exist in stable concentrations, the concentration of water vapor is highly variable and must be measured to be determined. The maximum partial pressure of water vapor is strictly a function of temperature. For example, at 20 C (68 F), the maximum partial pressure of water vapor is 23.5 mbar. The value of 23.5 mbar is said to be the saturation vapor pressure at 20 C (68 F). In a 20 C (68 F), saturated environment, the addition of more water vapor results in the formation of condensation. This condensation phenomenon can be exploited to measure water vapor content. Gas of unknown water vapor concentration is passed over a temperaturecontrolled surface. The surface is cooled until condensation forms. The temperature at which condensation forms is called the dew point temperature. Because there is a unique correlation between temperature and saturation vapor pressure (remember, the maximum partial pressure of water vapor, also known as saturation vapor pressure, is strictly a function of temperature), measuring the dew point temperature of a gas is a direct measurement of the partial pressure of water vapor. Knowing the dew point temperature, the corresponding saturation vapor pressure can be calculated or looked up. Frequently Asked Questions 1. What is dew point? 2. What is the difference between dew point and pressure dew point? 3. What is the effect of pressure on dew point? 4. Why is knowledge of dew point in compressed air important? 5. What is the typical range of dew point temperatures to be found in compressed air? 6. What are the standards for quality of compressed air? 7. How is dew point in compressed air reliably measured? 8. What are the telltale signs of a malfunctioning dew point sensor? 9. How often should a dew point sensor be checked or calibrated? Table 1 - Values for temperature and the corresponding saturation vapor pressure: Temperature C ( F) Saturation vapor pressure (mbar) 20 (68) 23.3 0 (32) 6.1-10 (14) 2.8-20 (-4) 1.3-40 (-40) 0.2 Figure 1 - Hand-held Dewpoint Meter 1 B211116EN-A

2. What is the difference between dew point and pressure dew point? The term pressure dew point is encountered when measuring the dew point temperature of gases at pressures higher than atmospheric pressure. It refers to the dew point temperature of a gas under pressure. This is important because changing the pressure of a gas changes the dew point temperature of the gas. Figure 2 - Instruments with graphical displays are useful for monitoring dew point over a longer period of time. Figure 2 3. What is the effect of pressure on dew point? Increasing the pressure of a gas increases the dew point temperature of the gas. Consider an example of air at atmospheric pressure of 1013.3 mbar with a dew point temperature of -10 C (14 F). From the table above, the partial pressure of water vapor (designated by the symbol e ) is 2.8 mbar. If this air is compressed and the total pressure is doubled to 2026.6 mbar, then according to Dalton s law, the partial pressure of water vapor, e, is also doubled to the value of 5.6 mbar. The dew point temperature corresponding to 5.6 mbar is approximately -1 C (30 F), so it is clear that increasing the pressure of the air has also increased the dew point temperature of the air. Conversely, expanding a compressed gas to atmospheric pressure decreases the partial pressures of all of the component gases, including water vapor, and therefore decreases the dew point temperature of the gas. The relationship of total pressure to the partial pressure of water vapor, e, can be expressed as follows: P1/P2 = e1/e2 By converting dew point temperature to the corresponding saturation vapor pressure, it is easy to calculate the effect of changing total pressure on the saturation vapor pressure. The new saturation vapor pressure value can then be converted back to the corresponding dew point temperature. These calculations can be done manually using tables, or performed by various kinds of software. Figure 3 - A variety of sample cell hardware, including quick disconnects, cooling coil and welded compression fitting, makes it easy to install a dew point sensor in any process. Figure 3 2

4. Why is knowledge of dew point in compressed air important? The importance of dew point temperature in compressed air depends on the intended use of the air. In many cases dew point is not critical (portable compressors for pneumatic tools, gas station tire filling systems, etc.). In some cases, dew point is important only because the pipes that carry the air are exposed to freezing temperatures, where a high dew point could result in freezing and blockage of the pipes. In many modern factories, compressed air is used to operate a variety of equipment, some of which may malfunction if condensation forms on internal parts. Certain water sensitive processes (e.g. paint spraying) that require compressed air may have specific dryness specifications. Finally, medical and pharmaceutical processes may treat water vapor and other gases as contaminants, requiring a very high level of purity. 5. What is the typical range of dew point temperatures to be found in compressed air? Dew point temperatures in compressed air range from ambient down to -80 C (-112 F), sometimes lower in special cases. Compressor systems without air drying capability tend to produce compressed air that is saturated at ambient temperature. Systems with refrigerant dryers pass the compressed air through some sort of cooled heat exchanger, causing water to condense out of the air stream. These systems typically produce air with a dew point no lower than 5 C (23 F). Desiccant drying systems absorb water vapor from the air stream and can produce air with a dew point of -40 C (-40 F) and drier if required. 6. What are the standards for the quality of compressed air? ISO8573.1 is an international standard that specifies the quality of compressed air. The standard defines limits for three categories of air quality: Maximum particle size for any remaining particles Maximum allowable dew point temperature Maximum remaining oil content Each category is given a quality class number between 1 and 6 according to the reference values shown in the table below. As an example, a system that conforms to ISO8573.1 and is rated for class 1.1.1 will provide air with a dew point no higher than -70 C (-94 F). All remaining particles in the air will be 0.1 um or smaller, and the maximum oil content will be 0.01 mg/m3. There are other standards for compressed air quality, such as ANSI/ISA- 7.0.01-1996 for instrument air. Table 2 - ANSI/ISA-7.0.01-1996 for instrument air. Quality Class Particle Size (um) Dew point C Dew point F Oil Content (mg/m3) 1 0.1-70 -94 0.01 2 1-40 -40 0.1 3 5-20 -4 1 4 15 3 37 5 5 40 7 45 25 6 10 50-3

7. How is dew point in compressed air reliably measured? Some principles of dew point measurement apply to all types of instruments, regardless of manufacturer: Select an instrument with the correct measuring range: Some instruments are suitable for measuring high dew points, but not low dew points. Similarly, some instruments are suitable for very low dew points but are compromised when exposed to high dew points. Understand the pressure characteristics of the dew point instrument: Some instruments are not suitable for use at process pressure. They can be installed to measure compressed air after it is expanded to atmospheric pressure, but the measured dew point value will have to be corrected if pressure dew point is the desired measurement parameter. Install the sensor correctly: Follow instructions from the manufacturer. Do not install dew point sensors at the end of stubs or other dead end pieces of pipe where there is no airflow. In addition to the general principles given above, consider the following when selecting and installing a dew point instrument: A. The best installation for a dew point sensor isolates the sensor from the compressed air line. This is accomplished by installing the sensor in a sample cell and connecting the cell to a T in the compressed air line at the point of interest. A small amount of compressed air is then bled past the sensor. The cell should be made of stainless steel and connected to the T with tubing (¼ or 6 mm). It is useful to install an isolation valve between the cell and the air line. This enables easy installation and removal of the sensor. B. A flow-regulating device is necessary to control to airflow past the sensor. The desired flow rate is only 1 slpm (2 scfh). The regulating device can be a leak screw or a valve. To measure pressure dew point, the regulating device is installed downstream of the sensor, so that when the isolation valve is opened, the sensor is at the process pressure. To measure dew point at atmospheric pressure, the regulating device should be installed upstream of the dew point sensor. C. Do not exceed the recommended flow rate. When measuring pressure dew point, an excessive flow rate will create a local pressure drop at the sensor. Because dew point temperature is pressure sensitive, this will create an error in the measurement. D. The best tubing material is stainless steel(ss). Nonmetallic tubing can absorb and desorb water vapor, creating a lag in measurement response. If SS tubing is not available, consider using PTFE or other materials that do not absorb water. Avoid the use of clear plastic tubing or yellow rubber tubing. E. It is possible to reduce installation costs for permanent dew point instruments by installing the sensor directly in the compressed air line. In these cases it is important to choose a location where the sensor has adequate airflow and where the temperature of the compressed air is at or near ambient. 4

8. What are the telltale signs of a malfunctioning dew point sensor? Some principles of dew point measurement apply to all types of instruments, regardless of manufacturer: An instrument that displays one value all of the time, as if the output or display were locked. An instrument that is bottomed out, always reading its lowest possible value. An instrument that is erratic, changing rapidly or randomly over a wide range of values. An instrument that displays impossibly dry or wet dew point values. Figure 4 - A fully integrated sampling system expands the versatility of a dew point sensor, enabling measurement of other plant processes that might not be under positive pressure. Figure 4 9. How often should a dew point sensor be checked or calibrated? It is best to follow the manufacturer s recommendation. Vaisala suggests a one or two year calibration interval, depending on the instrument. Sometimes a simple field check against a calibrated portable instrument is sufficient to verify correct operation of other instruments. Vaisala provides detailed calibration information in the User s Guide that is shipped with each instrument. Any time that you have doubts about the performance of your dew point instruments, it is wise to check their calibration. The sampling system includes a filter to clean the dirty sample gas and a needle valve to control the sample flow rate with the flow meter. A sample pump is used to generate a sample flow from processes at ambient pressure. Measurement in gas pressure Sampling Cell for Td Probe Valve Removable flow limiter Figure 5 - Sampling System and Sampling Cells Sample gas inlet DSC74B Sample gas outlet Measurement in atmospheric pressure Removable flow limiter Valve Sampling Cell for Td Probe Sample gas outlet Sample gas inlet DSC74B DSC74C Diffusion coil The sampling cell enables the measurement of the sampled gas either in gas pressure up to 10 bar or in atmospheric pressure depending on the gas inlet and outlet. Figure 5 For more information about Vaisala dew point measurement instruments, visit www.vaisala.com/dewpoint 5

www.vaisala.com