TW W-30 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

Similar documents
TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

! WARNING. Before using product, read and understand instructions.

Multistage high-pressure multistage centrifugal pumps

Installation Manual DIAPHRAGM WELL TANK

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

300 Series PA Pump and Cooler Assemblies

Oil and Coolant Circulating Heating System. Model - OCSM

Horizontal Jet Pumps 1/3-1-1/2 HP

32VFD Variable Frequency Drives for Centrifugal Chillers

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Installation Manual DIAPHRAGM WELL TANK

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Installation & Operation Manual for Energenics Air-Flow Optimizer

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Goulds Water Technology

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Axial and Mixed Flow Pumps for Large Volume Pumping

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Design & Construction Standards, Revised January

MAC-120HE-01 Air-Cooled Chiller

Utility Distribution Systems

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Heavy Duty Industrial Air Compressors

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Fire Pump Plan Review March 2010

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Ceiling Mount Air Handler Manual

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

FAIRBANKS NIJHUIS FIRE PUMPS.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Commercial Electric Water Heater

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

CRN A-F-G-E-HQQE 3x400D 50 HZ

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TECHNICAL INFORMATION Bulletin

Heating, air-conditioning, cooling

Model 1210C Battery Powered Pump Shown. Description

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Electric Water Heater

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Centro-Matic Automatic Lubrication Systems System Controls

The conditions below apply to the curves shown on the following pages.

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Pump Maintenance - Repair

SECTION VARIABLE FREQUENCY DRIVES

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

, User s Manual

MODEL INSTALLATION INSTRUCTIONS

Energy Recovery Device isave 21-40

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Light Duty Commercial Electric Water Heater

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

GLACIER POOL COOLERS, LLC OPERATOR INSTRUCTIONS, INSTALLATION AND SERVICE MANUAL

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

Installation Manual Version 7.3 IMPORTANT:

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Operational Overview and Controls Guide

Centrifugal Fans and Pumps are sized to meet the maximum

CRK A-W-A-BUBV

INSTANT HOT WATER RECIRCULATING SYSTEM

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Medical Air Systems: Scroll

ICQ Series - square centrifugal

Pumps SELECTION OF A PUMP

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

TROUBLESHOOTING GUIDE

BLADDER SURGE CONTROL SYSTEM

Horizontal Split Case Fire Pumpset Diesel Engine Driven

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

About Your NetBotz 4-20mA Sensor Pod

ASME Packaged Indirect Fired Water Heater

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators

8146/5 Series Breaker Panelboards

Basic Nameplate Information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SPP Pumps Inc. Atlanta

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Conlift1, Conlift2, Conlift2 ph+

Model 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Transcription:

TW1000-15W-30 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

TW1000-15W-30 FLAG FRAME The TW1000-15W-30 Flag Frame Booster System is equipped with a centrifugal pump regulated by a variable frequency drive that controls pump operation to maintain constant pressure regardless of varying demand or fluctuation in incoming pressure. This system will supply 15 GPM with a 30 PSI overboost. This system is built for a Quick assembly and Optimum operation. Features and Benefits: - Residential & Commercial application - Quiet, Compact & Powerful - Variable Frequency Drive controlled pump - Energy efficient operation - Prewired & Factory Tested Lead-Free* (Wetted) components: Centrifugal Pump: SS and Cast Iron Relief valve: Lead Free Brass Pressure Gauge: Lead Free Brass Transducer: SS TEE Lead Free Brass Check valve Lead Free Brass Fittings: Lead Free Copper Nipples: SS or Lead Free Brass *All lead-free brass shall contain <.25% Pb All parts shown are included in the system Actual system components may vary Some assembly required Pump performance curve Technical Specifications: Pump: Walrus (TEFC) [2T-3K] Controller: Emerson or equal Flow Rate: 15 GPM Boost: 30 PSI Overboost Horse Power: 1/2 HP Suction: 1 inch Discharge: 1 inch Tank: 2 Gallon Frame Size: 17 W x 17 H x 17 D Decibel rating: <70 db @ 3500 RPM Power Options: Independent circuit required 208-220V/1-3PH, 360-480V/3PH 115V [Non-GFCI Plug-in]

BOOSTER SYSTEM DIMENSIONS 5 17 17 17 TW1000-50W-35 FLAG FRAME BOOSTER SYSTEM Variable Speed Booster Pump System 50W-35 FLAG

GENERAL WIRING DIAGRAM VARIABLE FREQUENCY DRIVE T1 T2 T3 T4 T5 T6 TRANSDUCER NEGATIVE TERMINAL POSITIVE TERMINAL B1 B2 B3 B4 B5 B6 B7 POWER SUPPLY L1 L2 L3 U V W 3 PHASE TEFC MOTOR

GENERAL SPECIFICATIONS Assembled Units: Supply as shown on the engineering drawing a Variable speed system Model # TW1000-15W-30 Flag Frame Booster System as built by Towle Whitney or approved equal. System shall be capable of delivering a combined 15 GPM at 30 PSI boost over existing pressure. All wetted surfaces shall be lead free (<.25% Pb) in conformance with the 1/4/14 federal law Suction shall be 1 inch threaded [with spring loaded check valve] and discharge shall be 1 inch brass tank tee with appropriate adaptors to install a pressure transducer, pressure gauge & pressure relief valve. The pump control system shall include, as a minimum, a separate and independent variable frequency drive (VFD) for each pump and a manifold / Tee mounted 4-20 ma pressure transducer, pressure gauge, and relief valve The piping and frame shall not interfere with access to the controls Each system shall have a properly sized air charged pneumatic expansion tank Pump shall be connected to a separate and independent disconnect box [supplied by others] Variable frequency drive (VFD) shall: Be specified for either 115V, 208-220/1-3, or 360-480/3. The drive efficiency shall be 98% or better at full speed and load Have UL approval with all factory installed options Have all factory preset values and/or last saved data values must remain available to the operator in the event of a complete power outage Have at least NEMA 1 rated conduit enclosure. Operate to a program that protects the pumps against damaging hydraulic conditions such as: - Motor overload - Pump overflow surges - Loss of prime due to incoming water supply interruption - Hunting - Protection from overload through frequency/current optimization - Protection from hydraulic damage by restricting the pumps to operate beyond their published end of curve Automatically restart after an over-current, over-voltage, under-voltage or loss of input signal protective trip Have an operator control panel [keypad] for customization of parameters Include a feature to upload / download parameters into an external device to be used with another drive or the same drive Have a removable non-volatile memory device Be capable of accepting individual analog inputs from transducer. All transducer inputs must be wired to the variable frequency drive for continuous scan and comparison function Utilize a proportional ladder logic program - integral - derivative control function Display the following values: - Pump running/standby - Pump speed in Hz - User adjustable parameters such as PID set points - Motor frequency - Motor current - Threshold set points for PID error, Min operating frequency - Troubleshooting and diagnostics of faults

Pressure sensor / transducer: A pressure transducer shall be provided to supply all pressure signals to the variable frequency drive The transducer shall be rated for 100 PSI with a maximum pressure of 200 PSI and shall be 4-20 ma analog Separate transducers shall be supplied for each variable frequency drive to ensure redundancy GENERAL SPECIFICATIONS Centrifugal pump: The pump shall have a cast iron casing with 304 stainless steel impellers. The pump shall have a 316 stainless steel shaft sleeve and a replaceable tungsten carbide + HNBR mechanical seal. The pump mechanical seal shall be rated to withstand pressure of up to 142 PSI. The pump motor shall be manufactured in compliance with CE, RoHS and CSA. The pump motor shall be totally enclosed fan cooled with a JM shaft. Pneumatic expansion tank: Pneumatic expansion tank shall be rated for use with potable water with an operating pressure of a maximum 125 PSI Tank shall be pre-charged to a pressure of 10 PSI below system operating pressure Valves and fittings: Fittings on suction and discharge of centrifugal pump shall be sized appropriately to allow water velocity not exceeding 10 ft/sec, in order to minimize cavitation and turbulence Check valve shall be spring-loaded and silent Installation: Equipment shall be installed in accordance with applicable local building, electrical and plumbing codes The contractor shall assign the booster system assembly to within Towle Whitney s recommended tolerances prior to system start-up

Motors: The pump is coupled with a totally enclosed, fan-cooled, squirrel-cage motor (TEFC). Nominal speed: 3500 rpm at 60Hz Standard voltages: 3 phase : 230 / 460V Protection class: IP54 Insulation class: F Pumps: Horizontal multi-stage centrifugal pump, non self-priming, close coupled design, impellers mounted on extended motor shaft. Operating Limits: Ambient temperature: Max. 104 F (40 C ) Liquid temperature range: 32 F (0 C) to 194 F (90 C) Operating pressure: Max. 142 psi Inlet pressure: Max. 85 psi Suitable liquids: Clean or other non-corrosive liquids

BOOSTER SYSTEM WARRANTY Booster Pump Systems Three Year Limited Warranty This warranty applies to booster pump systems built by Towle Whitney LLC, and shall: Exist 36 months from the date of shipment. Be in effect only after installation photographs are received by Towle-Whitney LLC. Towle-Whitney LLC liability under this warranty shall be limited to the repair or replacement of any part or parts found to be defective (material or workmanship) within the warranty period. Towle-Whitney LLC shall determine whether the part needs to be returned, or field scrapped. The warranty excludes: Any water damage or consequential damage. Systems not installed in accordance with Installation and Maintenance Instructions. Labor, transportation, and related costs incurred by the customer. Misuse, negligence, inappropriate chemicals or additives in water. Inadequate protection from freezing. Lightning, high voltage spikes, accidents, floods, or acts of God. Re-Installation costs of repaired or replacement equipment. Re-Imbursement for the loss caused by interruption of service. This warranty applies to all states and territories of the United States and Canada only. There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. 800-807-9827 towle-whitney.com info@towle-whitney.com

VARIABLE FREQUENCY DRIVE SPECIFICATION * Drive selection for centrifugal pump is based on amperage [not on HP or KW]

PNEUMATIC EXPANSION TANK SPECIFICATIONS