Operation Guide 3M-30

Similar documents
NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Mode Switch. Fan Switch Menu button Program button

Operation Guide 3M-22

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

HEAT PUMP PROGRAMMABLE THERMOSTAT

Carrier Thermostat Quick Reference Guide

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

T-100-R Installation Guide

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Professional Contractor INSTALLATION GUIDE

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

EK908FHL - Thermostat for floor heating

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

HEAT HEAT COOL HEAT PUMP COOL

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Drayton Digistat +2RF

Installation and Operation Manual Environ TM Smart Thermostat

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Owner s Guide. ca6554

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

Mini Timer Owner's Manual. Model MT13A

ACONT900AC43UA Communicating, Programmable Comfort Control

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Video Baby Monitor System. User Guide

Smart Touch. Owners Manual. By INNOVATIVE POOL PRODUCTS LLC. For more information look us up on the web at

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

How To Control A Thermostat

SCORPION. micron security products

Variable Air Volume - VAV

QUICK INSTALLATION GUIDE

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

MAGICAR M871A. Car alarm with two-way remote User s guide

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

tattletale User Guide Consumer unit version P a g e

Install Guide 3M-50. Caution. Caution

INSTALLER S & OWNER S MANUAL

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Workshop 7 PC Software - Tracker

Bright House Networks Home Security and Automation Mobile Application. Quick Start Guide

HOMEOWNER S MANUAL. icomfort Wi Fi Thermostat CONTROLS /12. General. Touch Screen Programmable Communicating Thermostat

Weather Capture Software Guide Version 1.4 Revision: June

Single Zone LCD Thermostat Operating Instructions

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

HOTRONIX AIR FUSION. Table of Contents. Safety Instructions. Machine View. Touch Screen Guide Operating Instructions.

RETAINS STEERING WHEEL CONTROLS, SYNC MEDIA PLAYER, SYNC BLUETOOTH AND MORE!

RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Home Monitoring and Control service provided by Verizon Online LLC

Sensi TM. Wi-Fi Programmable Thermostat SCHEDULING GUIDE. Version: March Emerson Electric Co. All rights reserved.

How To Set Off An Alarm On A Car With A Car Alarm On It

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

HEAT SIPHON ANSWERBOOK

Installation Instructions

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

General Information. Do programmable thermostats really save energy?

1 For All Non-Programmable Digital Thermostat

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Midco SmartHOME. Professionally Monitored Service: User Guide. Touchscreen Key Fob Keychain Remote Web Access Device Access for ios and Android

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

EZ DUPE DVD/CD Duplicator

Set Top Box User Guide. Global Reach with a Local Touch

Bright House Networks Home Security and Control Mobile Application

Dash 18X / Dash 18 Data Acquisition Recorder

How To Use An Easypad On A Pc Or Macbook Or Ipad (For Pc)

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Smart Thermostat page 1

PR-2500 Portable Receiver. Owner s Manual

Smart Home Monitoring Powered by Honeywell Total TM Connect Remote Services Basic User Guide

TC --- PHP, TC --- PAC Comfort Series Programmable Thermostat. Owner s Manual

About Your System NOTE: What is included: Options and Accessories:

Operational Overview and Controls Guide

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

Using Time-of-Day Scheduling To Save Energy

To use your Brother machine in an ad hoc network, complete the steps listed below:

WHITE-RODGERS COMFORT-SET 90 SERIES

Nexus FS Point of Use Installation Guide

Navigator. Welcome 1 pg.3. Router Setup 2 pg.5. Send Expedition Data to Ventus Navigator 3 pg.6. Using Ventus Navigator 4 pg.8

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

The Parts of the System

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

Install Guide CT101. Caution. Caution

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

RETAINS STEERING WHEEL CONTROLS, SYNC MEDIA PLAYER, SYNC BLUETOOTH AND MORE!

RF 1. Contents: Connecting diagram. Detailed information:

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Welcome to a whole new level of interactive home security

Transcription:

PG 1 Operation Guide 3M-30 The 3M-30 programmable communicating thermostat operates via a high-quality, easyto-use touch screen. To program or adjust your 3M-30, simply touch your finger firmly to the screen. The screen will automatically light up and you will hear a beep. The screen will respond differently to different types of touches, so you may want to experiment by touching it different ways, finger, fingernail, etc. Do not use a sharp or metallic device; it will scratch the screen. Statement of use: 100% Compatible with all popular residential HVAC systems; 24VAC single, two stage conventional heating systems (gas/oil/electric), heat pumps, single stage or with auxilliary heat (electric or fossil), zoned forced air and zoned hot water (2 or 3 wire), millivolt systems (with 24VAC adapter), one or two stage cooling, and hybrid systems. Save Energy button Power Grid status indicator Reset button HVAC selections switches top cover bottom cover RADIO 1 LINK TARGET TEMP PM DAY AUTO F COOL Touch screen Wire terminals Mode switch Fan switch MENU button PROG button 1005-002-001 ENGLISH

PG 2 Control Screens Before you operate the 3M-30 please get familiar with these basic control screens. All the 3M-30 functions are accessed through these screens. HOME, MENU, PROGRAM and MANUAL. The 3M-30 touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows. HOME Screen The HOME screen is displayed when the unit is operating. Touching the HOME icon on the screen will always return you to this screen. To set a Mode: Set the mode switch on the side to the desired mode COOL or HEAT. FAN MODE - HEAT-OFF-COOL Time of day TARGET TEMP PM Current Room Temperature DAY HEAT Lock indicator Target Temperature Day Thermostat Mode

MENU Screen The MENU screen is the gateway to many functions or settings of the 3M-30. It is displayed when you press the MENU button. [See page 9 for details] Set Time Touch this area to set the time of day. Left arrow goes back, right arrow goes forward. Filter Timer set Differential set for 2nd Stage Temperature Swing set Set Day Touch this area to set the day of the week Calibration control Use this to calibrate your LCD display match to another thermometer. Set o C - o F Touch this to set temperature display. DIFF PM FILTER SWING CALIBRATE HVAC SETUP Touch this to configure the 3M30 to work with your HVAC system. Chirp set Touch this to turn the audible chirp on or off. F C HVAC SETUP HOME Lock Program Touch to Touch for 5 sec return to to lock or unlock. HOME screen. PG 3

PROGRAM Screen The PROGRAM screen sets the 3M-30 control for your home HVAC system. It is displayed when you press the PROG button. [See page 7 for details] PG 4 Set Time Slot Touch this area to set the Time Slot you want to program. Set Program Time Touch this area to set the time of day you want each time period to start. Left arrow goes back, right arrow goes forward. [Touch and hold for fast set] Copy Touch this area to copy current day s program to the next day. AM PROGRAM COPY DAY Set Program Day Touch this area to set the day of the week you want to program TargetTemps for. Return HOME When programming is complete touch this to run your program and return to the HOME screen. MORN F HEAT Temp Up / Temp Down Touch these to raise and lower each Target Temp. [Touch and hold for fast set]

MANUAL Screen The Manual Screen control screen is where you can make temporary changes to your 3M-30 s operation. Touch the main temperature display to use this screen. [See page 12 for details] Manual Override indicator Shows TEMPORARY when you have modified the Target. F Target Temperature Temp Up / Temp Down arrows Touch these to raise and lower the manual override Target Temp. TEMPORARY TEMP Room Temperature HOLD HOLIDAY HEAT Return HOME HOLIDAY Touch this to invoke a single program that repeats day after day until you turn it off. HOLD Touch this area to operate the thermostat as a manual thermostat. It will keep the temperature you set until you change it or cancel HOLD. PG 5

PG 6 Initial Settings Press MENU to prepare the thermostat (from HOME screen). Set day of the week - Touch the Day of the week area to cycle through the days of the week to select the current day. Set time of day - Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting. Set o F- o C display - Touch the o F and it will toggle to o C. Backward Forward Set audible chirp - Touch the musical note icon to select the chirp or no chirp. Return HOME by touching the icon.

Auto-run Program The 3M-30 comes pre-programmed with an EPA approved program. This program is recommended by the EPA for energy efficiency. We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program. To run the EPA program, set the mode switch to HEAT or COOL. Press the MENU button and use the arrows by the time display to set the time. Touch the DAY area and advance it to select the present day. Touch HOME. The unit is now running the program.t EPA HEAT MORN 6:00am DAY 8:00am EVEN 6:00pm NITE 10:00pm All Days 70 o F 62 o F 70 o 62 o F COOL MORN 6:00am DAY 8:00am EVEN 6:00pm NITE 10:00pm All Days 78 o F 85 o F 78 o F 82 o F TO CHANGE THE PROGRAM: Make sure the 3M-30 mode switch is set to either HEAT or COOL, then press the PROGRAM button. This puts you at the PROGRAM screen [see page 4]. The programmed start time is diplayed in the upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY, EVEN, NITE]. The programmed Target Temperature is shown on main display. The HEAT program and the COOL programs are separate. PG 7

PG 8 Select the day you want to program. The day of the week starts at SU - Sunday and can be advanced to the day you want to program. Touch the day of the week area to cycle through the days of the week to the desired day. Select the time slot (period) you want to program (MORN,DAY, EVEN, NITE). Touch the time slot area to cycle through to the desired period. Select the desired start time of that time slot. Touch the time arrows to select the desired period s starting time. Hold arrow down for fast time scrolling. Select the desired target temperature for that time slot. Touch the +/- arrows to select the desired period s temperature. To COPY one day s programming to the next day, touch COPY DAY once. The information for the current day will be copied to the next day which will appear on the screen. Holding down COPY for over 3 seconds will copy to all 7 days. Touch HOME to return to the Home screen.

MENU Screen Functions Press MENU to bring up MENU screen. TIME of DAY Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per touch). Touch and hold the arrow for fast time set (15 minute jumps). DAY of Week Touch DAY area to select present day. SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature between the 3M-30 setting and the room temperature required before the heating or cooling system will turn on from 0.5 to 2.0 F (.25 to 1 C). For example, if SWING is set to 2.0 F and the 3M- 30 is set to 70 F Target Temperature, the heat cycle will start when room temperature drops to 68 F. Similarly, the cooling system will start when the room temperature increases to 72 F. The HVAC then runs and will shut off at the Target Temperature. To set SWING: Touch SWING. Touch the left/right arrows to set the SWING from 0.5 to 2.0 F. The HVAC will run more frequently at.5 F and less at 2 F. Default is 1 F. Touch HOME to return to the MENU screen. PG 9

PG 10 F C Chirp set - Touch this to turn the audible chirp sound on or off. Set - Touch this to switch the temperature display scale from o F to o C. FILTER - AIR FILTER ALERT - The 3M-30 can be programmed to remind you when the air filter needs changing. Touch FILTER. The display will show the usage to date. Touch FILTER for over 3 seconds and the display will change to LIMIT. Touch arrows to set desired usage limit before filter alert comes on home screen. When this limit is reached, FILTER will be on home screen. Limit may be set from 0 to 999 days; default is 90 days. To reset, the usage back to 0, touch usage number; touching it again restores the displayed usage. Touch HOME to return to the MENU screen. LOCK (The 3M-30 has 2 lock modes) Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily override the 3M-30 Target Temperature with the +/- buttons only. (1 bar) For FULL lock : Touch the icon again for 5 seconds to go to full lock. No changes can be made. Full lock shows (2 bars). Once locked, the 3M-30 will respond just to MODE and MENU.

To UNLOCK, Press MENU. Touch and hold icon for 5 seconds for 2 bars (if not there already). Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate. Return HOME by touching the CALIBRATE icon. Your thermostat was accurately calibrated at the factory to ±1 F of actual ambient temperature. You do have the option, however, to change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -6 F to +6 F or -3 C to +3 C. To change your Thermostat Calibration, touch MENU and then touch CALIBRATE. Use the + / - to adjust the displayed temperature up or down, as desired. The DELTA FACTOR that appears on the screen will also automatically increase or decrease for each 0.5 (F or C) adjustment so you can see your change. The large display will show the modified temperature reading that will be displayed on the HOME screen and used as the new room temperature. Press HOME to return to the Home screen. DIFF (Used for 2 stage normal or heat pump with auxillary only, not on screen for single stage). The differential is the number of degrees between the room temperature and the Target Temperature at which the 2nd stage will be used. Default is 2 F. Touch MENU and then DIFF. use the arrows to set the DIFF. Recommend DIFF be set to 2 F for very cold climates and to 4 F for warm climates. PG 11

PG 12 MANUAL Screen Functions The 3M-30 has 4 manual override commands. The manual screen is accessed by touching the large current temperature display on the middle of the HOME screen. IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen. TEMPORARY override Touch the + / - arrows to select your desired temporary Target Temperature. Touch HOME to return to operation. The TEMPORARY icon will display indicating you have modified the Target Temperature for the current Time Slot only. It goes back to the program target at the next period. Also once in temporary, if the target is set the same as the programmed target for that period, the word TEMPORARY will go out. HOLD This will hold the target temperature you set indefinitely, until you turn HOLD off. HOLD will allow you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until you change it or cancel hold. Take care using the HOLD function as the program is now bypassed. To set a hold target temperature, touch HOLD and use the +/- icons to select your hold temperature. The HOLD icon will display on the HOME screen indicating you have changed the Target Temperature. The system will HOLD this temperature until you return to the manual screen and de-select HOLD by touching it. Hold is also canceled when you set the mode to OFF. HOLIDAY This is a single program that repeats day after day until you turn it off. It supersedes the weekly program. To use it touch HOLIDAY on the temporary screen. The default holiday program is shown below. To modify this program, touch the PROGRAM button and then touch the DAY area until

HOLIDAY appears (after SAT). The default HOLIDAY program is set as 2 time slots; all day (same target MORN, DAY and EVEN) and a different target for NITE. [Default program: HEAT 70 o F all day and 62 o F at night. COOL 78 o F all day and 82 o F at night.] EMER (in HEAT PUMP type) If you setup your 3M-30 for HEAT PUMP with auxiliary heat, EMER function is available with a switch under the top cover on the right. If you switch EMER to ON, your heat pump is disabled and auxiliary heat is your sole source of heat. This manual override stays active until you switch EMER off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is defective. Other Functions Save Energy Button The Save Energy feature on the 3M-30 provides a simple, easy-to-use way to help you manage your energy use. SAVE ENERGY automatically adjusts your Target Temperature up in COOL or down in HEAT by 4 o F. To use Save Energy, press the Save Energy button in the upper left corner of the unit. The screen will now read Save Energy. To return to normal operation, press the Save Energy button again. This is useful to save energy if you are gone for a short time. PG 13

PG 14 FAN Switch AUTO: The fan control is normally in AUTO mode, meaning that the fan operates automatically with the HVAC system and the thermostat. When the fan switch is in ON, the fan will run continuously until switched back to AUTO. [NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.] Simple Screen This display mode limits the amount of information on screen and limits the functions to just the +/- arrows. To access the limited display Simple Sceen, hold down the PROGRAM button for 12 seconds. Hold down the PROGRAM button for 12 seconds to leave the limited display screen. RESET button The RESET button re-boots the 3M-30 processor. It does not effect the user programs that have been stored in permanent memory. Compressor Protection The 3M-30 has a minimum cycle time of 4 minutes to protect your compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and A/C during this time and the compressor will not come on until the 4 minute delay is over.

Communicating Thermostat The 3M-30 has 2 RTM-1 radio ports. These allow your thermostat to communicate with other systems. Depending on your area power company, programs may be available to connect your thermostat to power grid status information. This can make it easy for you to moderate your energy use at peak hours and use power when it is less expensive. Using USNAP Radios - The USNAP ports allow you to connect your 3M-30 to your home WiFi network. This can give you access to your home s HVAC system even when you are away [with additional web service]. It can also give you access to web based efficient energy management sites that can help you save money and protect the environment.you can connect your 3M- 30 to an AMI network for In Home Display of electric grid status or connect to a Home Automation network for HA functionality with remote access to your HVAC system and home conditions. To Insert a USNAP radio module: Power off the 3M-30. Insert the radio module in either slot on the back of the 3M-30. Power up 3M-30. To connect to a network follow the instructions that came with the USNAP module. USNAP radio Caution USNAP port DO NOT INSERT or REMOVE USNAP radio modules if power is ON. This can damage the thermostat or radio modules. Customer support: filtrete@radiothermostat.com 888-607-5824 or www.radiothermostat.com/filtrete PG 15