TECHNICAL GUIDANCE QUESTION CONSIDERATIONS ANSWER. page 1 of 5

Similar documents
Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Understanding BS EN 771-3: Aggregate concrete masonry units

PRODUCT GUIDE lower tolerances high quality

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Technical handbook Panel Anchoring System

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

domestic structure SBSG 2007 ANNEX C

3 Masonry and Manufactured Stone (Interior and Exterior)

EAST LYME HIGH SCHOOL

0331 Brick and block construction

Technical Notes 3B - Brick Masonry Section Properties May 1993

Solid shape molding is not desired in injection molding due to following reasons.

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

Aluminium systems profile selection

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Module 3.7. Thermal bridging

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Rockwool Flexi Insulation Application Guide

If stepping is required, step at 180mm as seen in this picture.

Dubai Municipality Standard DMS 1: Part 5: 2004

ADVANTAGES OF MODULAR LAYOUT

Installation Window Building In Details

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Section 5A: Guide to Designing with AAC

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

2.0 External and Internal Forces act on structures

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

How to Measure for Exterior Shutters

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Superform Products Ltd.

LAYING BLOCK AND BRICK

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Chapter 2 Basis of design and materials

CI/SfB (Ff3) January Masonry design guide. Showing you the way ECOBLOCK

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

rationel WINDOWS WITH VISION

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Ceramic Glazed Brick Exterior Walls

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Further Reading Monitoring cracks Contacts Historic Scotland Technical Conservation Group Conclusion

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

How to build a Pizza Oven in 4 days

PERFORMANCE GUIDELINES

INTRODUCTION TO BEAMS

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit

Squash Court Design general points

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

Wisconsin Building Products Evaluation

Garver Feed Mill Condition Evaluation

Timber Frame Construction

Physics 11 Assignment KEY Dynamics Chapters 4 & 5

Elegance SC. Solar Control

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Installation Instructions

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

Choosing the Right Mortar for the Job

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

AUTOMATIC SWINGING DOOR

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

MASONRY SUPPORT & WINDPOST SYSTEMS

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Energy efficient home design

WATERPROOFING OF WET ROOMS

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE

Detailing of Reinforcment in Concrete Structures

ISSUE 2. Installation Guide

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Chapter. Earthquake Damage: Types, Process, Categories

Glass partitions SFB 3074

Connex. Mortarless Masonry Block System

Directorate for the Built Environment Building Standards Division

Dimensioning and Estimating Brick Masonry

Agrément Certificate 06/4300 Product Sheet 1

Introduction. Welcome London Road, Mitcham

Heating Load Calculation

The BASA Guide to the ISO Classification of Sealants for Building Construction

Chapter 8 Design of Concrete Mixes

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

BLADE S-MAX Cabinet for Blade Server

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CH. 2 LOADS ON BUILDINGS

Exhaust Calculation Booklet

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Transcription:

MOVEMENT CURTAIN MARKING E WALLING OF JOINTS SAFETY FORMED IN GLASS MASONRY FROMWALLS 6.1/28 STACKED - January WINDOW 2016 ARRANGEMENTS (First Issue as Technical Guidance) 2015 QUESTION In cavity masonry walls where should vertical movement joints be located with respect to end walls, corners and window/door openings? CONSIDERATIONS Movement in masonry cavity walls can be caused by a combination of actions including expansion, contraction and the volume changes resulting from the effects of moisture within the masonry units. Movement can be reversible such as that caused by temperature variations, or one way as caused by the expansion that occurs as clay bricks age or by shrinkage that occurs as concrete blocks/bricks age. Colour, texture and the orientation of a wall to the sun can also affect the heat absorbed by the masonry and the resulting degree of movement. The size and shape of the masonry panels, whether they are square or long rectangles, as well as the distribution of openings and restraints will also influence the build up of stresses and subsequent movement. Movement joints should be provided to control expansion and contraction and avoid unsightly cracking. The joints should be properly constructed to cater for the calculated degree of movement without reducing the stability and weathertightness of the wall. ANSWER Calculating the theoretical movement of a wall is complex which is why general guidance for spacing of movement joints is usually adopted. Standards clause 6.1.3 Table 1 quotes joint widths and spacing for movement joints in the outer leaf to minimise the risk of major cracking in different types of masonry. The distances quoted, between vertical movement joints, are based on straight sections of wall. Horizontal expansion of the continuous panels of a masonry box will try to push the corners outwards (see Diagram 1). Where the length of wall exceeds the stated joint spacings, this effect can be reduced by sub-dividing the wall into shorter lengths of less than the normal spacing (see diagram 2), or by locating the first movement joint approximately half the stated joint spacing from the corner (see Diagram 3). In theory, an expansion joint could be located at the corner, but this would affect the buttressing offered by the return wall unless the masonry was suitably tied in accordance with an engineer s design. In order for a return wall to provide sufficient buttressing to the flank wall, without providing additional ties, the expansion joint should be located at least 550mm from the internal corner (see Diagram 3). page 1 of 5

6.1/28 - January 2014 2016 Some guidance suggests that the distance between movement joints, measured around a corner, should be the same as the distance between movement joints in a straight wall. This approach could lead to a requirement for movement joints in end walls particularly with concrete block/brick masonry. In practice, providing that the length of an end wall between returns is not greater than the normal spacing of movement joints for the masonry material, it should perform satisfactorily even when the first movement joint on the return wall is up to half the maximum distance for the masonry material. Straight clay brickwork walls containing short staggers with offsets less than 675mm, (see Diagram 4), should be treated as if they were a straight wall when determining movement joint spacings. Therefore if the sum of the lengths of wall on either side of the stagger exceeds the maximum length without a movement joint then a movement joint should be introduced into one of the two lengths or at the stagger as shown in Diagram 4. Staggers and movement joints in masonry walls, other than clay brickwork, should be engineer designed. Movement joints should not coincide with door or window openings due to the difficulty in continuing the movement joint between the frames and masonry and around the ends of the lintels (see Diagram 6). Vertical movement joints should therefore be located in sections of full height masonry between the openings (see Diagram 5). Where a full height masonry panel does not exist (see Diagram 7) the location and detailing of the movement joint should be designed by an engineer to avoid it passing around window and door frames. Window and door openings in effect divide the wall into a series of masonry panels. This can lead to uncontrolled cracking in narrow horizontal panels between openings on different floor levels. Where the length to height ratio of each panel is high e.g. more than 3:1, the distance between movement joints may need to be reduced. Alternatively, bed joint reinforcement may be used to control the stresses. Any reinforcement should be used in accordance with the manufacturer s recommendations. See also Technical Guidance 6.1/14 Movement joints in clay brick masonry and Technical Guidance 6.1/16 Masonry bed joint reinforcement. As a general rule movement joints in the outer leaf of external walls should be provided at not more than the following centres: Clay brickwork - 12m (15m max) Lightweight concrete block/brick (autoclaved or using lightweight aggregates gross density not exceeding 1,500kg/m 3 ) - 6m Dense concrete block and brick (using dense aggregate gross density exceeding 1,500kg/m 3 ) - 7.5-9m Calcium silicate brick - 7.5-9m Any masonry in a parapet wall (length to height ratio > 3:1) - half the above spacings and 1.5m from corners. Movement joint widths for clay bricks should be not less than 1.3mm/m i.e. 12m = 16mm and for other masonry not less than 10mm page 2 of 5

6.1/2 2014 6.1/28 - January 2016 Diagram 1 = Thermal movement forces. Movement is directly proportional to the length of wall * cracking External leaf (brick or blockwork) - wall in excess of maximum length Internal leaf (blockwork) * recommended without a movement joint. Corners pushed outwards causing vertical cracking of masonry at corners. WORST CASE Diagram 2 Movement joint in centre of wall 3 - wall divided into equal sections, each less than maximum recommended length without a movement joint. BETTER Diagram 3 = Up to half recommended length of wall without a movement joint min 550mm -central section of wall between s less than the maximum recommended length without a movement joint. BEST Movement joints provided closer to corners - Wall ties within 225mm of movement joint @ maximum 300mm centres vertically. General Note: Movement joints in internal walls are not normally necessary for single dwellings unless the walls are straight and unbroken and over 6m long, in which case the block manufacturer s recommendations should be adopted. This may include the use of bed joint reinforcement in the courses above and below window openings. page 3 of 5

6.1/2 6.1/28 - January 2014 2016 = Movement forces. Movement is directly proportional to the length of wall Internal leaf (blockwork) Tendency to crack in these positions External leaf (brickwork) WORST CASE Compressible joint BETTER Arrangement Slide by joint BEST Arrangement Diagram 4 - Short staggers in external cavity walls made from clay brickwork. page 4 of 5

6.1/28 6.1/2 - January 2014 2016 Diagram 5 - Movement joint should be in full height masonry between window and door openings. Diagram 6 - Movement joint should not pass through openings due to the difficulty in continuing the joint between the frames and masonry and around the ends of the lintels. Diagram 7 - Where there is no full height path within the masonry the movement joint should be engineer designed to avoid any door or window openings. The design may involve the introduction of a slip plane to link the staggered joint. = Consideration should be given to the provision of bed joint reinforcement to control movement in the outer leaf where length to height ratio is high i.e. greater than 3:1. Similar bed joint reinforcement is often recommended by the block manufacturer within the inner leaf both above and below openings. page 5 of 5