Opis zmian wprowadzonych w Adroit7 wersja 7.0.1.1



Similar documents
User Guide Win7Zilla

PowerLogic ION Enterprise 5.6

SA-9600 Surface Area Software Manual

Point of Sale 2015 Enterprise. Installation Guide

PowerLogic ION Enterprise 6.0

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

WhatsUp Gold v16.3 Installation and Configuration Guide

Pcounter Web Report 3.x Installation Guide - v Pcounter Web Report Installation Guide Version 3.4

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

User s Manual. Management Software for Inverter

@ptitude Observer. Installation Manual. Part No Revision G

FactoryTalk Gateway Getting Results Guide

PaperClip Audit System Installation Guide

StruxureWare Power Monitoring 7.0.1

File Management Utility User Guide

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

User Manual WatchPower

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

DataLogger Kepware, Inc.

CentreWare Internet Services Setup and User Guide. Version 2.0

Installation Instruction STATISTICA Enterprise Server

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Installation Instruction STATISTICA Enterprise Small Business

TRBOnet Enterprise 3.0

Viewing and Troubleshooting Perfmon Logs

JUL / 07 VERSION 3.2

NETWRIX WINDOWS SERVER CHANGE REPORTER

Using DC Agent for Transparent User Identification

VERITAS Backup Exec TM 10.0 for Windows Servers

Introduction and Overview

Iridium Extreme TM Satellite Phone. Data Services Manual

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

User Guide. Version 3.2. Copyright Snow Software AB. All rights reserved.

NETWORK PRINT MONITOR User Guide

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

How To Install Powerpoint 6 On A Windows Server With A Powerpoint 2.5 (Powerpoint) And Powerpoint On A Microsoft Powerpoint 4.5 Powerpoint (Powerpoints) And A Powerpoints 2

Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide

11.1. Performance Monitoring

Moxa EDS-SNMP OPC Server Pro User s Manual.

UNICORN 7.0. Administration and Technical Manual

IBM FileNet Image Services

RedBeam Asset Tracking User Manual

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.

Installation Guide: Delta Module Manager Launcher

AVG 8.5 Anti-Virus Network Edition

ClearSCADA. Software for Telemetry & Remote SCADA Solutions

ewon Getting Started

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Automation License Manager

ManageEngine IT360. Professional Edition Installation Guide.

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

Rapid Assessment Key User Manual

IsItUp Quick Start Manual

Sage Intelligence Financial Reporting for Sage ERP X3 Version 6.5 Installation Guide

Dream Report Version 4.5

Tool for Automated Provisioning System (TAPS) Version 1.2 (1027)

Danware introduces NetOp Remote Control in version 7.01 replacing version 7.0 as the shipping version.

VEEAM ONE 8 RELEASE NOTES

Device configurator DRC200

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

FactoryTalk View Site Edition V5.0 (CPR9) Server Redundancy Guidelines

NJ SQL Best Practices

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Samsung Drive Manager User Manual

WINDOWS PROCESSES AND SERVICES

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

EntroWatch - Software Installation Troubleshooting Guide

User s Manual. Management Software for ATS

Software Operations Manual

rev. 31 (applies to CyBro OPC Server v3.0.4 and later)

PTPhoneManager II. User guide

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

Advanced Event Viewer Manual

Xactimate v.27 Network Installation

2014 Schneider Electric Industries SAS. This computer program is protected by copyright and international treaties.

UNICORN 6.4. Administration and Technical Manual

DiskPulse DISK CHANGE MONITOR

PMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán Olomouc Czech Republic

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

Installation Guide - Client. Rev 1.5.0

Industry White Paper. Ensuring system availability in RSView Supervisory Edition applications

How To Use Safety System Software (S3)

1 Minimum system requirements

X Series Application Note 43:

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

SQL Server 2008 R2 Express Edition Installation Guide

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

Kepware Technologies Optimizing KEPServerEX V5 Projects

ODBC Client Driver Help Kepware, Inc.

SharpdeskTM R3.1. Installation Guide Version

QUANTIFY INSTALLATION GUIDE

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03

Product Description and Getting Started with Adroit

Table of Contents. Introduction...9. Installation Program Tour The Program Components...10 Main Program Features...11

System Integration Software

SysPatrol - Server Security Monitor

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

Transcription:

AT Control System Sp. z o.o. ul. Nowiny 56B, 80-020 Gdańsk tel./fax +48 58 306-53-91 www.atcontrol.pl email: handlowy@atcontrol.pl Opis zmian wprowadzonych w Adroit7 wersja 7.0.1.1 Note: Please check that your Adroit installation folder (typically C:\Adroit) does not contain any.dmp files, and if it does then delete them. Those affecting the Agent Server - Fixed the memory creep issues related to using CreateThread. - Moved the affinity code from as.exe to pool.dll so that it now applies to both the Agent Server (as.exe) and the Agent Server Service (ass.exe.). - Agent Server dump files (.DMP) are no longer created by default. These files are only created when there is a problem with a WGP file. If necessary, you can enable their creation by adding the HKEY_LOCAL_MACHINE\Software\Adroit Technologies\Adroit\Workgroup\CreateDumpFiles DWORD registry key and setting its value to 1. - The efficiency of the screen messages, displayed when loading the Agent Server, has been improved to avoid long loadup times. - The logon and logoff of the Adroit UI are now auditable events, when auditing the Agent Server. - Fixed the intermittent failure of the Agent Server to start up that was caused by the unprotected multithreaded access to internal string variables. - Potential invalid memory operations are now prevented. - Changed the GetSupergroup methodology to improve the reliability and efficiency on Agent Servers with large agent counts (more than 100000). - Improved memory allocations for public transactions. - Fixed a bug which caused XP embedded computers that do not support the mailslot functionality (used for AS window messages) to continually have 100% CPU load. Fixed a memory creep issue that is particularly noticeable when using DBAccess agents. Those affecting the following agents: - Alarm: 1) The alarm priorities now default to the agent priority setting when loading Adroit 6.0 WGP files. 2) NEW: Implemented the following DWORD registry key: HKEY_LOCAL_MACHINE\SOFTWARE\Adroit Technologies\Adroit\Workgroup\WG.INI\AcknowledgeAtStartup, whose default value is 1, which Strona 1 z 10

enables the acknowledgement of alarms at startup. Set this value to 0 to disable the acknowledgement of alarms at startup. Set this value to 0 to startup and check and acknowledge each startup alarm individually to ensure that the process is under control. - AlarmManagement: 1) Fixed issues with the queries, Pie/Bar checkbox and exporting of data. 2) NEW: Added support for the TOP(%t) constraint, which If enabled, specifies the topmost number of incidents returned by this query. For instance, when the table records are ordered by time in ascending order, the specified number of the most recent records is returned. Likewise, when the table records are ordered by time in descending order, the specified number of the oldest records is returned. 3) NEW: Added the UserKPIs table so that users can add and/or specify their own KPI target values. Some of these values parameterize certain default queries so that you can customize these queries according to your needs. 4) NEW: Added the INTEGER enginequeuesize slot, which displays the number of incidents that the AlarmManagement agent still needs to log to the database. This should always remain at 0. - Analog: 1) Improved the accuracy of ROC alarming for sub-second changes. - Audit: 1) Fixed the initialization of each tag s startup value, so that subsequent changes are properly detected. - Counter: 1) If the agent name contains the '/' character, these characters are now replaced with underscores '_' in their persistence file names, so that these files can be created. - Datalog: 1) When fetching data from SQL Server, this agent no longer uses the user regional settings and ONLY uses the SYSTEM regional settings. Therefore please ensure that the SYSTEM regional settings (and in particular that the decimal separator character) are compatible with the regional settings used by your SQL Server otherwise ALL the updates to and from SQL will fail. - DBAccess: 1) Checking whether the Agent Server is in standby mode (for an Adroit cluster) no longer relies on subscriptions to minimize delays in detecting this change in Agent Server status, which previously caused double entries to be logged as the new standby server continued to write to the database. - Device: 1) Removed a global variable to prevent the intermittent crashing of the Agent Server when Strona 2 z 10

starting a device. 2) NEW: Implemented the following DWORD registry key: HKEY_LOCAL_MACHINE\Software\Adroit Technologies\Adroit\Scanning\MarkBadOnStartup, whose default value is 1. If this value is set to 0 then all values are marked healthy on startup. Currently the Agent Server does not poll values at startup, so if you use long poll periods then you can set this value to 0 to mark your values healthy and display the values on startup that were last saved in the WGP file. 3) Imported @scan tags can now be unscanned. 4) New: In order to make the cluster mode switchover more efficient, the Device agent now performs the standby mode subscription monitoring. This provides a far less noisy and more efficient switchover especially in heavily overloaded scanning configurations that contain hundreds of scan agents. It also puts a lot less stress on the internal subscription buffer and so is less prone to agent locks and timeouts. - Digital: 1) Changed the CreateThread calls to _beginthreadex to eliminate possible memory creep. - Marshal: 1) Changed the methodology for pulsing its digital values. - MaxDemand: 1) NEW: This agent no longer requires an OEM licence to function. 2) NEW: You can now browse REAL slots into the enabletag slot. In this case if the REAL value is greater than or equal to 1 then the agent is enabled (its enable slot is set to TRUE,) otherwise if the REAL value is 0 the agent is disabled (its enable slot is set to FALSE). - Perfmon: 1) NEW: Added the \\Process(as)\\Virtual Bytes counter as a default counter. - Recipe: 1) Fixed an importing bug affecting list slots in which only the first entry in the list of strings was imported. - Scan: 1) NEW: Implemented the following DWORD registry key: HKEY_LOCAL_MACHINE\Software\Adroit Technologies\Adroit\Scanning\MarkBadIfWriteFails, whose default value is 1. If this value is set to 0 then Adroit does not mark values bad when their write fails. Typically you would set this value to 0 for devices that do not allow writes to certain registers and therefore the write fails which causes the agent to go scan bad, so that the next read will simply overwrite the value that the user wanted to write in the first place. 2) NEW: This agent no longer performs standby mode subscription monitoring, which is now handled by the device agent to make the cluster mode switchover more efficient. Strona 3 z 10

- SNMPManager: 1) Improved the agent locks and the transaction efficiency. 2) NEW: Added the STRING lastwritestatus slot, which displays a text message that informs the user whether the last value written to the device was successfully changed in the device or not. - Statistical: 1) If the agent name contains the '/' character, these characters are now replaced with underscores '_' in their persistence file names, so that these files can be created. - Stringlist: 1) Fixed an importing bug affecting list slots in which only the first entry in the list of strings was imported. Those affecting the UI: General - Fixed the file Open dialog to include recipe and wizard documents. - Changed the method of timing in the AdrSchedule() class in attempt to resolve the intermittent missing of long schedule times. - Improved support for the translation of the Alarm, Chart, Configurator and Trend windows. - Trend, Recipe, Chart, Web and Event windows now occupy the same ratio of the screen regardless of the size of the monitor on which they are opened, like Mimic and Alarm windows. In other words their position and size relative to the window size are now ratio rather than pixel specific. This MAY cause your previously saved Adroit document windows to become misaligned in their relationship to each other, in which case you need to open them on your engineering station, re-align and resave them. - When overriding monitor size settings, these overridden values are saved for your Adroit document windows and NOT the detected screen size values. - Improved support for document portability across monitors - Added the Monitor setup... button to the Advanced UI preferences dialog. This opens the Monitor dimensions dialog, which allows you to view and/or override your monitor dimensions and/or provide multi-monitor support (when the Adroit UI screen is displayed on more than one monitor). It also allows you to specify the methodology that should be used (for advanced use only) when positioning saved Adroit document windows on the screen (either Ratio (in relation to monitor dimensions, default) or Pixels (as designed/saved). - Fixed the display of the overridden monitor width and height values when opening the monitor dimensions dialog. - If your monitor and/or graphic card and/or resolution has changed since the last time an Adroit document was saved, then a message box is displayed containing the previous and current monitor sizes and resolutions. If you disagree with the new reported sizes, you are directed to the Advanced UI preferences so that you can override these values. Strona 4 z 10

Alarm windows - Fixed the disabling of the global acknowledge menu item if HIDDEN is specified as its security group. - Fixed the intermittent exception when changing column formats that caused the UI to crash. Chart windows - NEW: Each document window can now chart up to 16 pens (previously only 8 were supported). - To reduce the effect of "ghost images" from appearing when using Adroit charts (which requires that the UI is restarted), new charts are now created with the "display of series values hints" (tooltips) option DISABLED (OFF) by default. - The chart is also automatically placed into real-time trend mode when undoing zoom mode for line and strip charts. Web windows - Added menu item security for the Navigate menu. Those affecting Other components: - Adroit Datalog Backup Viewer (logviewer.exe): 1) Added support for a universal separator in CSV files. So that these CSV files are no longer limited to being delimited by commas but now can be delimited using the List separator character specified by the system. - Adroit DB Generator (dbgen.exe): 1) Fixed CSV file paths for importing CSV files when using the CSV connector. - Adroit OPC Browser (opcbrowser.exe): 1) NEW: Implemented the following DWORD registry key: HKEY_LOCAL_MACHINE \Software\Adroit Technologies\Adroit\OPC Browser\DisableItemProperties, whose default value is 0. Set this value to 1 to improve the speed of retrieving information from certain slow OPC servers. - Adroit Security Manager (adrsecurity.exe): 1) Minor fixes. - Adroit Server OLE Interface (MISSrvr.exe): 1) Fixed the local time UCT conversion when poking date/time slots. Strona 5 z 10

- Adroit Utility DLL (adrutils.dll): 1) Fixed the Visual Studio 2005 compatibility issue in ShowFileList. - Adroit WGP Inspector (wgpinspect.exe): 1) Functionality improvements. Other enhancements: Changes made to the Adroit 7.0.1 CD Setup: - A new setup option has been added to install SQL Express. Changes made to the Adroit Demonstration: - Various improvements affecting the correct display of the Adroit document windows launched by the demo. Changes made to the supported Utilities on the Adroit 7.0.1 CD: - The password for the wrapped SQL Express installation is now strong so that it will meet domain password naming rules. - Microsoft SQL Server Management Studio Express is now on the CD (\Utilities\SQL_EXPRESS\Microsoft SQL Server Management Studio Express), which allows you to manage and view instances of Microsoft SQL Server 2005 Express Edition (SQL Server 2005 Express). Drivers: IMPORTANT: Since we use Microsoft's latest compiler to produce the Adroit 7 drivers, ALL the protocol drivers from Adroit 7 onward are incompatible with protocol drivers in previous versions of Adroit. See the procedure at the top of this email on how to UPGRADE EXISTING DRIVERS. UPGRADE any existing drivers when upgrading from a prior version of Adroit to Adroit 7, as follows: Note: This procedure does NOT apply if you performed a COMPLETE uninstall of the previous version of Adroit or if you are installing Adroit 7 on a new computer. 1. Ideally, select YES when you are asked by the Adroit installation to upgrade your existing drivers. If you select NO then open the Start menu, Programs, Adroit 7 and select the Upgrade Existing Drivers shortcut. This compares any drivers in the Adroit installation folder against the Adroit 7 drivers on the Adroit installation. If you have existing drivers, then the Adroit driver install dialog is displayed, listing the currently installed drivers. 2. Select the first driver in the Available drivers list and click the Install button. 3. Once the driver is installed (and its relevant documentation is displayed), select the next driver and click the Install button. 4. Repeat this until all the listed drivers have been upgraded. The following is a list of drivers provided by Adroit 7.0.1: Note: Drivers with bold revision numbers indicate that the driver has been updated, see below Strona 6 z 10

for a description of the improvements. No. DLL name Driver Description Revision 1 ABBP214 Asea Brown Boveri Procontrol 214 Driver 77 2 ABSLC500 Allen Bradley SLC 500-DF1 Serial Driver 7 3 ABTCP Allen Bradley Ethernet Driver 18 4 ABXKF2B Allen Bradley (DH+) KF2 Driver 90 5 ADVNTECH Advntech PCL818 Series Driver 5 6 BECKER Becker M500 Relay Serial Driver 1 7 BECKHOFF Beckhoff TwinCAT ADS-DLL API Driver 8a 8 BLNDTECH Blendtech Series 20 Additive Controller Driver 0 9 CEFP2000 Centralised Electronics Fire Panel 2000 Driver 90 10 CONET Conet Card Exception-based Driver 17 11 CONETPCI Conet PCI Card Exception-based Driver 6b 12 CYPHER Cypher Base Station Driver 1 13 DIAMONSP DiaMon Serial Driver 7 14 DIGIBUS DIGIbus DPM Driver 2 15 DIMETRAP Dimetra-P TCP driver 8 16 DLRML81 DLRA MUL-T-LINK Driver 14 17 DNP3 DNP 3 Driver 49a 18 DT95SEAL DT95SEAL Exception-based Driver 8 19 DTAKER Datataker Telemetry Driver 20 EAGLE Eagle PC Card Driver 11 21 EAGLEE Eagle EDR-Enhanced (EDRE) PCI Card Driver 2 22 ELEOLV24 Electromatic Optolink V24 Dupline 128 Driver 80 23 GEM80 General Electric ESP (GEM 80) Driver 3c 24 GSM_SMS GSM SMS Driver 9e 25 GSTPROFI GST Profibus Exception-based Driver 16 26 GSTPROFS GST Profi SoftFEP Exception-based Driver 12 27 HITACHIE Hitachi Ethernet Driver 15 28 HITACHIH Hitachi H Series Driver 23 29 INTRAC Intrac 2000 Exception-based Driver 12 30 JOYSCC JOY SCC Exception-based Driver 4a 31 KDL105KS Koyo Direct Logic 105 K-Seq Driver 75 32 KDL205KS Koyo Direct Logic 205 K-Seq Driver 75 33 KDL405KS Koyo Direct Logic 405 K-Seq Driver 75 34 KMSUCOMA Klockner Moeller SUCOM-A Driver 15a 35 KOYO_ETH Koyo DirectLogic Ethernet Driver 6 36 LECOMAB Lenze LECOM A or B Serial Driver 4 Strona 7 z 10

37 LG_GLOFA LG Glofa GM Series Driver 2 38 LONWORKS LonWorks Driver 39 LOVATO Lovato RGAM Serial Driver 4 40 MITAJC24 Mitsubishi A-Series C24 Driver 17 41 MITAJE71 Mitsubishi AJ71E71 TCP (not UDP) Driver 105 42 MITFXS Mitsubishi FX Series Driver 8 43 MITQJE71 Mitsubishi Q or QnA Ethernet Driver 28 44 MOD_ETH Modbus Ethernet Driver 47 45 MODBUSI Modbus I (RTU and ASCII) Driver 57 46 MODBUSP Modbus Plus MBXAPI Driver 19 47 MODBUSR Modbus Radio Driver 14 48 MOOICI32 Moore Local Instrument Link via ICI 320 Driver 4 49 NHPMICRO NHP MicroLink (MLC14) Driver 1 50 OMR_ETH OMRON Ethernet Driver 12 51 OMRSYSMC OMRON Sysmac Driver 99 52 OMRSYSMM OMRON Sysmac Modem Driver 100 53 OPC_CL OPC Client Driver 67 54 OPTO22 Opto 22 (OPTOMUX) Driver 1 55 PAGER Pager Exception-based Driver 12 56 POLY_ETH PolyComp GTX Sign Ethernet Driver 7 57 POLYCOMP PolyComp Sign (GTX) Driver 7 58 RDC8102 RDC8102 Exception-based Driver 5 59 REMOTRON Remotronics GAR System 300 Exception-based Driver 1 60 RKC_CBXX RKC CB100-900 Serial Driver 1 61 RODAM RODAM Driver 0 62 SAMSUNG Samsung N70 or 700+ Driver 1 63 SASCOM SASCOM (RTU and ASCII) Driver 3 64 SCANRS ScanRs (RS-232 Barcode Scanner) Driver 13 65 SCH3964R Schiele SYSTRON S 800 3964 and 3964R Driver 2 66 SCHCUST1 Schiele Custom Protocol #1 Driver 9 67 SCS_SGC SCS_SGC Alarm Station Driver 1 68 SDESYMAX SQUARE D SyMax Ethernet Driver 6 69 SHIMSR SHIMDEN SR50 Series Driver 2 70 SIE3964R Siemens S5 3964 and 3964R Driver 90a 71 SIEH1 Siemens H1 Driver 27 72 SIEINAT Siemens Ethernet Driver 11 73 SIEL1 Siemens Sinec L1 Bus Exception-based Driver 3 74 SIEL2 Siemens L2 Driver 9 Strona 8 z 10

75 SIES7FN Siemens S7 Functions (SAPI) Exception-based Driver 32 76 SISTAR SiStar PCU Server Driver (Intel) 33 77 SPABUS SpaBus Driver 4 78 SPECTR Spectrum tele-ranger Driver 56 79 SPESCADA Spectrum SCADA-MUX Driver 12 80 SQDSYMAX SQUARE D SyMax Serial Driver 2 81 STKEMAX Strike ENERMAX Driver 9 82 TDC0550 TDC I 0550 Serial Driver 0 83 TI500 Texas Instruments 500 or 505 Series Driver 14 84 TITCPIP Texas Instuments TCPIP Ethernet Driver 13 85 TOSHBIN Toshiba (Binary) Driver 2 86 TOSHIBA Toshiba (RTU and ASCII) Driver 13 87 TOST2ETH Toshiba T2 Ethernet Driver 29 88 UHT4 UHT4 - Engine hot-test bay (Motorola) Driver 2 89 UNIPCOM Unitronics PCOM M-90 or M-2XX Series Driver 6 90 USERDRV User-defined Exception-based Driver 32 91 VAALCOR Vaalcor Exception-based Driver 1 92 VAMS Voest Alpine Monitoring System Driver 19a 93 VANT_PRO Vantage Pro Serial Driver 1 94 YOKOGAWA Yokogawa uxl DCS Driver 4a Driver Enhancements and Bug Fixes: DiaMon Meter Serial Protocol Driver 7 : This fixed the issue which required all 24 items to be used in order for the scan job to succeed. 6 : Removed Carriage Return in messages to create connection to modem. 5 : Implemented a check for nulls. 4 : Added check for modem echo when dialling up and also added purge of communications before each write. Mitsubishi Q/QnA Ethernet Protocol Driver 28 : Support the writing to clusters and fixed the Device Dialog, which previously did not allow you to select Secondary when creating the first device. 27 : Added String Support. 26 : Implemented multiple CPU and MC protocol and PLC cluster checking also fixed the Primary/Secondary switching. Documentation updated. Modbus Ethernet Protocol Driver 47 : Bug fix. 46 : NB FIX - fixed the memory creep injected in rev 43 45 : Removed Start/Stop from the Critical Section to allow one to easily start or stop when the device is backlogged (the over-subscription of one or more scan jobs). Strona 9 z 10

44 : Fixed issue with extension max items. 43 : Added IEC addressing functionality. Documentation updated. IMPORTANT: If you are using rev 43 of the Modbus Ethernet Driver then we HIGHLY RECOMMEND that you upgrade to the latest rev 47. Modbus I (RTU and ASCII) Protocol Driver 57 : Added 6-character Modbus Address size, same as MOSCAD for all PLC types and also added Topological Address Specification as in MOD_ETH. Also add check for DSE PLC type for it's write only registers that should be in a single job. 56 : Added Multiple Write with Deep Sea Electronics Unit and Added DSE Unit as PLC selection. 55 : Removed Start/Stop from the Critical Section to allow one to easily start or stop when the device is backlogged (the over-subscription of one or more scan jobs). Also Writes, Validate and Map Preference are now given priority over reads to improve performance when backlogged. RKC CB100-900 Serial Protocol Driver 1 : Added Moxa Cluster Aware Capability. Siemens Ethernet Protocol Driver (INAT) 11 : Added better error checking when creating connections. 10 : Fixed a bug introduced by rev 8 in the 4 byte jobs. 9 : Added optimized string support. 8 : Fixed incorrect pseudo to job mapping, fixing rare edge anomalies and unpacking errors. Documentation updated. Strike ENERMAX Protocol Driver 9 : Fixed the crash in the driver when Processing Billing Data used invalid date/time data, such as day = 90. Strona 10 z 10