PRT-1553 Installation (ZT )

Similar documents
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D , D

GENERAL RUBBER LINING PRINCIPLES

3M Scotchcast Mine and Portable Cable Splice Kit

INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX

CYGNAL Application Note

DASH KIT INSTALLATION

SMD Rework Station TABLE OF CONTENTS

Reasons for reissue are in Section 6, REVISION SUMMARY.

Written By: Walter Galan

LED Wiring and Connections

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Assembly Guide FOR LED NEON FLEX

GENUINE PARTS INSTALLATION INSTRUCTIONS

Written By: Walter Galan

Written By: Walter Galan

Written By: Walter Galan

RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions

CamSplice Assembly Manual

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Written By: Sam Lionheart

DVD-60C The Seven Sins of Wire Harness Assembly

HVAC Blower Motor Only Operates On High

AMPSEAL* Automotive Plug Connector and Header Assembly

A better way to install PL-259 connectors on RG-8X type coax Dan Richardson, K6MHE

Computer Lane Monitor HOW TO MAKE A TAPE AND HOW TO READ A TAPE

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

Wall Mount Installation and Use

ipad 2 GSM Headphone Jack & SIM Slot Replacement

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

AN114. Scope. Safety. Materials H AND SOLDERING TUTORIAL FOR FINE PITCH QFP DEVICES. Optional. Required. 5. Solder flux - liquid type in dispenser

Kemlite Transportation Products

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear

MOUNTING STRAIN GAGES TO THE LOAD CELL BODY

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Electronics and Soldering Notes

Weatherproofing Coaxial Cable Connections

Weatherproofing Kit for Connectors and Antennas

Soldering Techniques N I A G A R A C O L L E G E T E C H N O L O G Y D E P T.

Caring for Your PleurX Pleural Catheter

Rubber Lining Application Manual Revision Date: September 1, Section 10: Pipe Lining Procedures Page: 10-1

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

COATING & WRAPPING OF UNDERGROUND PIPING

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Alfa Romeo 147 On board instruments installation guide

DIY Advanced Dry Bags

Gear PEPSI CAN STOVE INSTRUCTIONS

4 Installation Requirements

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

MICRO-COAX Space Grade Cable Assembly Integration Manual

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Bill Conkling July 2012

All About Your Peripherally Inserted Central Catheter (PICC)

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

Sun Windows General Information Sun New Construction Window Installation Instructions

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Waxing guide for recreational and fitness skiers

HGS620 Shielded Outlet Termination Instructions

Nintendo 64 Power Supply Power Cord Replacement Guide Page 1 of 10. Nintendo 64 Power Supply Power Cord Replacement Guide

LASER PRINTING PROBLEM SOLVER

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

Application Note. Soldering Methods and Procedures for 1st and 2nd Generation Power Modules. Overview. Analysis of a Good Solder Joint

Floriani Embroidery Project PATCH PERFECTION

RS232/DB9 An RS232 to TTL Level Converter

TrūShine Gel Enamel FAQs

How to Build a Cosmic-Ray Cloud Chamber

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x mm)

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

NELSON HEAT TRACING SYSTEMS

THE 7 SINS OF WIRE HARNESS ASSEMBLY TRAINING CERTIFICATION TEST (DVD-60C)

New Printhead. Properly Maintained Printhead Over 1 Million Inches

Heated throw User manual

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

staple gun with 5/16 Long staples

Basic Bread. Equipment: Ingredients:

Central Venous Catheter (CVC) Sterile Dressing Change - The James

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0

Minor Cracks in Horizontal Surfaces

Basic soldering is a skill that's easy to learn and not too hard to master. It just takes practice.

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

How to become an Operation Christmas Child Shoe Box Character

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

Termination Procedure. FCUPC One Piece Connector

Ignition Coil Sealing Instructions Revision 1.0

Paper Chromatography: Separation and Identification of Five Metal Cations

Science and Technology of Everyday Life Hope College, GEMS 151. Electrodyanamic Speaker

DVD-111C Advanced Hand Soldering Techniques

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

Teaching Time: One 25-minute period. Lesson Summary Students use iron filings to observe the 2 and 3- D field lines around a magnet.

How To Make a Broomball Stick:

Transcription:

Background PRT-1553 Installation (ZT04-98-001) The PRT-1553 is a shielded cable repair kit designed to repair Mil-Std-1553 and other shielded cable which have minor insulation and shield braid damage. These repair kits are not splice kits and any cable exhibiting damage that affects primary wire insulation below the shield is not repairable using this kit alone! Never attempt to use this kit to repair cables with damaged primary wires unless an approved primary wire repair device has been installed prior to utilizing this kit. Each PRT-1553 kit contains a length of Z- 3250 EMI Shielding Tape and a piece of PRT-ES Tubing. The EMI tape will be utilized to repair the shield damage and the tubing will create an environmentally sealed and electrically insulated repair of the cable jacket. The Problem Photograph #1 illustrates a classic example of a shielded electrical cable that has suffered insulation and shield damage. The damage level is severe enough to cause EMI leakage in addition to exposing the shield braid to corrosion. However, the primary wire insulation is still intact and cutting the wire in half to install a wire splice is typically undesirable as this type of repair may affect the wires overall electrical resistance and would create a very stiff area that may lead to future failure. The PRT-1553 kit was developed to create a quick, reliable repair of both the shield and outer jacket insulation that is virtually as good as the original cable. The advantage of using a PRT-1553 kit on minor insulation and shield damage is that it can be installed quickly with minimal harness and connector disassembly and is far more rugged and reliable than a temporary tape wrap repair. A PRT-1553 repaired cable will provide many years of service assuming it s installed correctly. Photo 1: Cable Jacket and Shield braid damage 1

Installation 1) Measure the outside diameter of the damaged cable at a location away from the defect using a caliper. Use Table 1 and find the measured cable diameter in column 1. Select the correct PRT-1553 repair kit size and part number from column 2. Table 1 PRT-1553 Sizing Chart Cable Diameter Inches (mm) PRT-1553 P/N: ZT04-KT-001-(xx) Cable Diameter Inches (mm) PRT-1553 P/N: ZT04-KT-001-(xx) 0.075 0.125 (2 3.2) 0.126-0.174 (3.2 4.5) 0.175 0.249 (4.5 6.3) -01 0.50 0.62 (13 16) -03 0.63 0.74 (16 19) -05 0.75 0.87 (19 22) -11-13 -15 0.25-0.37 (6.3 9.5) -07 0.88 0.99 (22 25) -17 0.38 0.49 (9.5 13) -09 2) Clean the cable jacket surface around the damaged area and at least 2.0 inches on either side. Use Isopropyl Alcohol (IPA) and a clean cloth to remove all dirt, grease and oil residue from the cable jacket. 3) Trim away any loose jacket material as necessary. (Photo 2 & 3) 2

Photo 2: Typical cable jacket damage. Photo 3: Damaged insulation removed. 4) Determine if the cable damage has caused any broken or severely distorted shield braid strands (Photo 1). If no shield braid damage is evident proceed to step 8. If the shield braid is damaged, carefully inspect the primary wire insulation and determine if it is damaged. If the primary wire insulation is damaged, STOP! Primary wire damage is not repairable using this kit alone. If the primary wire insulation is not damaged proceed to Step 5. 5) Remove the jacket insulation back 1.0 inches from each side of the central damaged area (Photo 4). 6) Fold and dress any broken shield braid strands back over the undamaged braid area. Insure that all broken strands are facing away from the primary wire insulation so they cannot cause a puncture and short circuit. (Photo 5) 3

Photo 4: Insulation removed around braid damage Photo 5. Broken shield strands dressed back smoothly. 7) Use the piece of Z-3250 Tape supplied in the kit to repair the damaged EMI shield. Peel back the paper release liner from the adhesive side of the Z-3250 Tape approximately 1-inch. Apply the adhesive side of the tape directly to the metal shield braid, beginning where the jacket insulation stops. Spirally wrap the tape over the entire shield braid area using a 50% overlap technique. (Photo 6 & 7) 8) Using the PRT-1553 insulation tubing supplied in the kit, wrap the tubing around the cable so the amber colored hot melt adhesive material faces the cable. In all cases, the PRT-1553 tubing should extend beyond the shield repair area by at least 1/2-inch on each end. Peel back the paper release liner covering the adhesive strip on the outside of the tubing about half way. Overlap the tubing so the edge without the adhesive just covers all of the exposed adhesive, but no more! Peel back the remaining release liner and finish sealing the tubing. (Photo 8) 4

Note: For small damage areas you can cut the repair tubing and shielding tape to an appropriate length using a pair of scissors. Insure the tubing overlaps each end of the original cable jacket a minimum of 1/2 inch. Photo 6: Wrap damaged shield braid with Z-3250 Tape. Photo 7: Finished shield braid repair. Photo 8: PRT-1553 Tubing sealed around cable 5

9) Center the PRT-1553 tubing over the damaged cable area and orientate so the overlap seam covers the defect area. 10) PRT-1553 tubing requires a hot air type of heat gun with a temperature setting of approximately 150-160ºC to shrink the tubing and allow the hot melt adhesive to flow. For best results, use a heat gun with a small reducer nozzle that will localize the heat stream. (Photo 9) Caution: When shrinking PRT-1553 do not use a heat reflector designed to spread the heat evenly around the tubing. Photo 9: Reducer nozzle on heat gun. 11) Begin shrinking the PRT-1553 tubing by directing the heat source at the adhesive overlap area near the center of the repair tubing. (Photo 9) Apply heat to the adhesive overlap area only! The overlap area will tend to curl up into a U shape as it is heated. Continue applying heat in short bursts to this area until the surrounding tubing begins to pull the U shape back down flat. Do not be afraid to apply extra heat to the overlap area, as it will take extra dwell time for the inside layer of the overlap to begin to shrink. Do not be alarmed if the outer layer of the overlap flap tends to lift off the adhesive and curl back slightly during initial heat exposure. With continued heating, this lifted area will generally lay back down on its own, if not, lightly tap the lifted edge as necessary with a wooden Popsicle stick. Do not squeeze the PRT-ES when tapping the lifted lip down. Use extreme caution when touching the tubing as it will be hot and sticky. Shrink the overlap seam area over it s entire length before attempting to recover the remaining tubing. (Photo 10) 6

Photo 10: Overlap seams curled up prior to full shrinkage. 12) Once the overlap seam area has fully shrunk you may apply heat to any remaining areas of the tubing that have not yet shrunk. Continue to apply heat until the hot melt adhesive begins to ooze out and creates a fillet around the cable circumference at each end. (Photo 11) Heat the remaining tubing slowly and evenly. Too much heat, applied too quickly in one location will cause the hot melt adhesive to expand unevenly and possibly rupture the overlap seam. 13) Once complete and while the assembly is just warm to the touch, use your thumb to rub the tubing overlap seam area and remove any exposed closure adhesive. The excess adhesive will ball up ahead of your thumb. Discard any residue. Caution: DO NOT attempt to remove excess adhesive using solvents. 14) Allow the assembly to fully cool to room temperature before placing assembly back in service. Photo 11: Finished PRT-1553 jacket with good adhesive fillet 7

Repair Kit Unavailable If PRT-1553 repair kits are unavailable it is possible to create a similar repair using the materials shown in Table 2. This type of repair is limited to cable diameter larger than 1-inch (25mm). The difference is that the PRT Tubing, Z-3250 Tape and Z-Block (135) Tape must be procured separately. 1) Use Table 2 to find the measured cable diameter in column 1 and select the sizes of each material listed in columns 2, 3 and 4. 2) Prepare the cable as described in the Standard Installation steps 1 to 6. 3) Cut a strip of Z-3250 Tape from the roll long enough to wrap the shield defect area on the cable using a 50% overlap technique (see Standard Installation step 7). 4) If necessary, cut the Z-Block hot melt tape (P/N: ZT02-03-002) to the width shown in Table 2 using a pair of scissors. Insure that the paper release liner has been removed from the amber colored hot melt tape prior to wrapping the cable. Helically wrap the tape over the previously installed shielding tape and overlap the original cable jacket a minimum of 1-inch at both ends. Use a soldering iron or the hot tip of the heat gun to melt the last tape wrap so the tape sticks to itself. (Photo 12) Caution: Keep the Z-Block tape wrap buildup to a minimum. Too much tape may cause a seam rupture in the PRT Tubing. 5) Install the PRT tubing around the cable as described in the Standard Installation step 8 and follow steps 9 thru 14 to complete the installation. Photo 12: Z-Block Tape wrapped around cable. 8

Table 2 Raw Material Part Numbers & Sizes Cable Diameter inch (mm) PRT Tubing p/n: ZT98-04-016-# Z-3250 Tape p/n: ZT93-03-003-* (width, in.) Z-Block (135) Tape¹ p/n: ZT02-03-002 (width, in.) 1.0 to 1.12 (25 29) 1.13 to 1.24 (29-32) 1.25 to 1.37 (32-35) 1.38 to 1.49 (35 38) 1.50 to 1.62 (38 41) 1.63 to 1.74 (41 44) 1.75 to 1.87 (44 48) #9 1.0 1.0 #10 1.0 1.0 #11 1.0 1.0 #12 1.0 1.0 #13 1.0 2.0 #14 1.0 2.0 #15 1.0 2.0 ¹ Z-Block Tape is available in two melt temperature ratings. Z-Block (100) will melt and flow around 110ºC while Z-Block (135) flow at around 140ºC. Standard PRT-ES materials use the Z-Block (135) material but either can be used and is dependant on operating temperature of the system being repaired. All Z-Block tapes are provided in 2.0 inch wide rolls and may be cut to the desired width using a pair of scissors. Revised 05/11 9