ADVANCED GEOTECHNICAL SOIL STABILIZATION (AGSS) Consulting Engineers

Similar documents
Lighthouse Engineering, L.L.C.

SECTION EARTH MOVING

SECTION 1 GENERAL REQUIREMENTS

Proposed Minimum Subterranean Termite Treatment Standards

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Designed and Engineered to Perform

TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL

PILE FOUNDATIONS FM 5-134

DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS

Settlement of Foundations on Expansive Clays Due to Moisture Demand of Trees CIGMAT 2008

Chapter 9 Remedial Measures

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

ALLOWABLE LOADS ON A SINGLE PILE

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Lighthouse Engineering, L.L.C.

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

Chapter 4 SUBSURFACE INVESTIGATION GUIDELINES

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Specification Guidelines: Allan Block Modular Retaining Wall Systems

DESIGNING STRUCTURES IN EXPANSIVE CLAY

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

REMEDIAL STRATEGIES FOR SHRINK SWELL SOILS: TEXAS EXPERIENCE

GOOD NEWS BUT NOT ALWAYS

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Name: PLSOIL 105 & 106 First Hour Exam February 27, Part A. Place answers on bubble sheet. 2 pts. each.

Elevating Your House. Introduction CHAPTER 5

Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures

C. Section TESTING LABORATORY SERVICE.

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION MATERIALS CONSTRUCTION REQUIREMENTS

Moisture and Resilient Floor Covering

Chapter 3 Pre-Installation, Foundations and Piers

SECTION SHEETING, SHORING AND BRACING

CHAPTER 11 STORM DRAINAGE

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

Design and Construction of Auger Cast Piles

EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND

6 RETROFITTING POST & PIER HOUSES

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Cold Weather Concrete Practices

Storm Drain Inlet Protection - IP

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

STATE OF VERMONT AGENCY OF NATURAL RESOURCES DEPARTMENT OF ENVIRONMENTAL CONSERVATION WASTE MANAGEMENT DIVISION SOLID WASTE MANAGEMENT PROGRAM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT RESOURCE REGULATION TRAINING MEMORANDUM

Residential Deck Safety, Construction, and Repair

Breakaway Walls

Coexisting with Expansive Soil. An Informational Guide for Homeowners

Rehabilitation Strategies for Bonded Concrete Overlays of Asphalt Pavements

DUDERSTADT FOUNDATION & CONSTRUCTION, LLC.

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

APPENDIX B. I. Background Information

3 Masonry and Manufactured Stone (Interior and Exterior)

GEOTECH ENGINEERING and TESTING

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Section EXCAVATION AND BACKFILL FOR UTILITIES

Chapter 2 Basis of design and materials

Current as of 11/10/08 1 of 1

Oil Spill Clean-up by Homeowner in Ohio *

STANDARD SPECIFICATIONS SECTION SEWER MAIN AND LATERAL CONNECTION SEALING BY CHEMICAL GROUT

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

How to Identify, Evaluate & Repair Shrinkage Cracks in Poured Concrete

USE OF A DIGITAL SURVEY VEHICLE FOR PAVEMENT CONDITION SURVEYS AT AIRPORTS. Paul W. Wilke, P.E. Applied Research Associates, Inc.

5006 Cherry Ridge Road Richmond, Texas LIMITATIONS AND DISCLAIMERS

How to Estimate the Cost of Support of Excavation for Foundation Installation. CPE Candidate No May 15, 2013

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

SUBSURFACE INVESTIGATION and FOUNDATION RECOMMENDATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

STRUCTURAL ASSESSMENT

Installation PowerPoint for Grasscrete Formers

CIVL451. Soil Exploration and Characterization

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

Washington ,

CID STREET INFRASTRUCTURE ASSESSMENT

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Inspection, Maintenance, and Repair of PaCT Canadian Pacific Rogers Pass Tunnels British Columbia, Canada

EARTHWORKS COMPLETION REPORT ELLEN STIRLING PARADE, ELLENBROOK. Ellenbrook, W.A. Georgiou Group Pty Ltd

Bernie Nimer, Dave Seton Mayfair Hotel Development Corporation

National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Section 2100-Trenching and Tunneling

Transcription:

ADVANCED GEOTECHNICAL SOIL STABILIZATION (AGSS) Consulting Engineers AGSS-ICS IONIC CHEMICAL SOLUTION SPECIFICATIONS AND APPLICATION METHODOLOGY FOR REMEDIATION OF DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS (photographs included) Clayey soils with swell potentials are stabilized using an ionic chemical solution called AGSS- ICS. Existing structures that have been distressed due to swelling subgrade soils can be remediated by treating the soils with the AGSS-ICS ionic chemical solution. The results of the application of the AGSS-ICS chemical solution to the subgrade soils will reduce the swell and shrinkage potential of the soil, reduce the soil suction, and increase the strength of the clayey soils through the processes of isomorphic substitution within the clay lattice and cation exchange around the sides of the clay lattice particles. These physio-chemical processes reduce the negative charge of the clay particles (isomorphic substitution in the clay lattice) and also reduce the negative surface charge of the clay particles (cation exchange and increased cation density on the surface of the clay lattice). Reducing the negative charge within the clay lattice and on the surface of the clay lattice results in a clay structure that has more flocculent characteristics and less dispersed characteristics; and subsequently less swell potential, greater strength, and less soil suction. The AGSS-ICS chemical solution is generally prepared by mixing (1) part concentrated AGSS- ICS ionic chemical with (300) parts water, producing a very diluted and safe ionic chemical solution. The resultant ionic chemical solution is injected into the soil subgrade at a rate such that (1) gallon of concentrated AGSS ionic chemical treats 11 cu.yds. of subgrade soil. This is equivalent to treating 11 cu.yds. of subgrade soils with (300) gallons of the diluted AGSS-ICS solution. The methodology used to remediate (stabilize) swelling soils beneath existing structures is to inject the chemical solution to depths ranging from 7 feet to 11 feet in depth unless refusal is encountered. The determination of the injection depth will be dependent on factors such as the depth of swelling clay soils and also the swell potential and swell pressure of these clay soils. The chemical solution is injected into the subgrade clays beneath the distressed house using hydraulic jetting methods. The hydraulic jetting method uses a ½ inch steel wand emitting the AGSS-ICS solution into the soil at a pressure of 800 to 1000 psi. For the injection of the chemical solution around the perimeter of the structure the injection points are placed 3 feet apart along each row. The first row of injection points will be placed 9-inches outside the exterior of the foundation, the second row of injection points will be placed 21-inches outside the exterior of the foundation, and if a third row of injection points are required they will be placed 36-inches outside the exterior of the foundation. The injection points in each row will be offset or staggered relative to the adjacent rows. See Figure 1A in the Attachments for a design detail of the injection methodology and specifications for the chemical injection around the perimeter of a structure. Figure 1B presents a second injection option around the perimeter of the house. In this option there are only two rows of injection points with injection points in each row spaced 2 feet apart instead of 3 feet. The first row of injection points will be placed 9-inches outside the exterior of the foundation, the second row of injection points will be placed 21-inches outside the exterior of the foundation as illustrated in Figure 1B in the Attachments. The injection points in each row will be off-set or staggered relative to the adjacent rows. Photographs 1 and 2 in the Attachments shows the injection rig that is used for remediating existing structures. Photographs 3 and 4 shows the injection process around the perimeter of existing structures. 5945 N. Grand Canyon Dr., Las Vegas, Nevada 89149-702-645-9916 or 702-275-8153

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 2 The injection pattern on the inside of the structure will be developed by spacing vertical injection points 3 feet apart along each row. Each row of injection points will be spaced 1.5 feet apart or less and off-set or staggered with respect to the adjacent rows injection points by 1.5 feet. The resultant spacing of the injection points will be approximately 2.1 feet or less. See Figure 2 in the Attachments to this document for a design detail of the injection methodology and specifications for the perimeter and interior of a structure. Photographs 5 and 6 shows the interior injection process through the concrete floor slab of the structure. When injecting penetrate 1 foot at a time and continue injecting at each foot for a period that may vary between 50 seconds to 60 seconds. Total injection time per hole will be a minimum of 6 minutes for a 7 foot deep injection and a minimum 9 minutes for an 11 foot deep injection. Stop watches will also be required to ensure accurate time increments for each injection depth. Use 7 foot or 10 foot long vertical pole stands with 1 foot increments marked on the poles placed adjacent to the injection wands to ensure accuracy of injection depth increments. The spacing and location of the injection points can be adjusted if conditions warrant it. Typical justification for adjusting the injection locations will be an excessively wide footing below the ground surface, surface obstructions, large rocks or caliche, and excessive saturation. If adjustments to the injection spacing or location is desired, contact the engineer before adjusting the spacing. If there is center lift on the slab or there is excessive heave of the slab then the interior injections are recommended. If the interior injections are performed then only inject two rows around the exterior of the structure. If there is no center lift and only edge lift then it may be possible to remediate the structure without injecting the interior of the structure and only inject around the exterior perimeter of the structure. In this case it will be necessary to inject three rows around the exterior perimeter of the structure. In this case the floor slab and exterior elevation brackets should be monitored every 6 months to determine if just injecting the perimeter was enough to stabilize the swelling clayey soils and to stop the movement of the structure. The reduction in shrink/swell characteristics of the on-site clays will be an ongoing continuous process as the solution migrates in the soil through the process of soil suction and osmosis. The performance of the clay stabilization methodology using the AGSS-ICS injection is best evaluated by performing manometer surveys of the interior floor slab and exterior foundation surveys of the house on regular 6 month intervals for 2 years. These elevations surveys should be performed before the subgrade soils are injected. The objective of the chemical injection treatment process is to significantly reduce the swell potential of the clayey soils in the injected soil horizon. If post-injection swell testing is performed on undisturbed samples of treated soils, they must be performed using ASTM D 4546, Method B at the moisture content of the undisturbed sample (no dry back). Do not perform swell tests on disturbed treated samples since the disturbance adversely affects the structure and swell potential of the treated soil. When performing swell tests on untreated and treated samples, this comparative testing must be performed at the same sample density and moisture content. The moisture content of the untreated and treated swell test samples should both be at the in-situ moisture content of the soil after injection. This will require the untreated swell test samples to be remolded at the same moisture content and dry density as the undisturbed treated swell test samples. Do not perform any testing until at least three months after the injection of the chemical solution; however, waiting for longer periods will provide for further migration of the ionic chemical solution in the soil due to soil suction and osmosis. After injection of the ionic chemical ADVANCED GEOTECHNICAL SOIL STABILIZATION 2

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 3 solution to stabilize the subgrade clays there will be a slight adjustment to the structure as the moisture and cation concentrations in the injected subgrade will mobilize and become more uniform throughout the site due to the processes of osmosis and soil suction. Due to the hydrophobic characteristics of the chemically treated subgrade, the potential or tendency for the subgrade soil to suck or attract moisture from outside the injection zone of the subgrade will be significantly reduced resulting in less volume changes (swelling or shrinking) with time. The AGSS-ICS ionic chemical solution can also be used in new construction to stabilize swelling clays. In this instance the chemical is mixed with water in either water pulls or water trucks in a ratio of (1) part chemical to (300) parts water. The soil is overexcavated to the depth recommended by the Geotechnical Engineer and then the same soil is used as fill in lifts that are no larger than 6 to 8 inch loose lifts. The chemical solution is applied to the loose lift with a water pull or water truck. Subsequent to this the chemical solution and soil is processed (mixed) using either a disk or reclaimer. The loose soil lift is then compacted with a wide rubber tired vehicle such as a scraper, water pull, or front end loader. The reason for using the large rubber tired vehicle to compact the loose soil is to achieve more of a flocculent clay structure instead of a dispersed clay structure. The chemical treatment of the clay will also produce a more flocculent clay structure with less swell potential, greater strength, and less soil suction. Illustrations of the application of the ionic chemical solution for the remediation of existing structures are shown in the Attached Photographs. Photographs 1 through 2 shows the injection rig used to apply AGSS-ICS including pumps and tanks. Photographs 3 through 4 shows exterior injection around perimeter of building. Photographs 5 through 6 shows injection in interior of building. Photographs 7 through 8 shows injection process using a concrete vibrator attached to the top of the injection wand. These photographs also show a measurement stand with one foot markings. ADVANCED GEOTECHNICAL SOIL STABILIZATION William R. Sublette, Ph.D., P.E. Principal Engineer Attachments: 1. Figures 2. Photographs ADVANCED GEOTECHNICAL SOIL STABILIZATION 3

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 4 ATTACHMENTS Figure (drawings) and Photographs ADVANCED GEOTECHNICAL SOIL STABILIZATION 4

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 5 Figure 1A: Chemical Injection Detail Illustrating AGSS-ICS Injection Methodology and Specifications for Structure Perimeter (Option 1 - three rows of injections around perimeter). ADVANCED GEOTECHNICAL SOIL STABILIZATION 5

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 6 Figure 1B: Chemical Injection Detail Illustrating AGSS-ICS Injection Methodology and Specifications for Structure Perimeter (Option 2 - two rows of injections around perimeter). ADVANCED GEOTECHNICAL SOIL STABILIZATION 6

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 7 Figure 2: Chemical Injection Detail Illustrating AGSS-ICS Injection Methodology and Specifications for Structure Perimeter and Interior (Option 3 perimeter and interior injections). ADVANCED GEOTECHNICAL SOIL STABILIZATION 7

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 8 Photograph 1: AGSS-ICS chemical injection rig. Four pumps and (2) 500 gallon tanks. Photograph 2: AGSS-ICS chemical injection rig. Four pumps and (2) 500 gallon tanks. ADVANCED GEOTECHNICAL SOIL STABILIZATION 8

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 9 Photograph 3: Injection of AGSS-ICS beneath perimeter of structure with steel wand. Photograph 4: Injection of AGSS-ICS beneath perimeter of structure with steel wand. ADVANCED GEOTECHNICAL SOIL STABILIZATION 9

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 10 Photograph 5: Injection of AGSS-ICS beneath interior floor slab using steel wand. Photograph 6: Injection of AGSS-ICS beneath interior floor slab using steel wand. ADVANCED GEOTECHNICAL SOIL STABILIZATION 10

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 11 Photograph 7: Injection into hard ground adjacent to wall using both hydrojetting and vibration. A concrete viberator is duct taped to the top of an injection wand in areas that are hard to penetrate. ADVANCED GEOTECHNICAL SOIL STABILIZATION 11

DISTRESSED STRUCTURES OVERLYING SWELLING CLAYS Page 12 Photograph 8: Quality control of the injection process is very important. The wand penetrates the soil at a rate of approximately 50 seconds/foot and injects the chemical solution at a rate of 4.5 gallons/minute. The technician uses a stop watch and the white pole with the 1 foot blue tape intervals to control the injection process. ADVANCED GEOTECHNICAL SOIL STABILIZATION 12