PXG3.W100. Web interface BACnet/IP. Desigo PX

Similar documents
BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

TX OPEN RS232/485 module

Digital input modules

PCS0100en Persy Control Services B.V. Netherlands

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

PXM20-E. Operator unit DESIGO PX

HMI display Installation Guide

Air damper actuators

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

OZS Web server. For LPB/BSB plants

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Automation stations modular model

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

IntesisBox KNX Mitsubishi Heavy Industries AC

User Manual. EtherUSB

HWg-STE HWg-STE PoE MANUAL

Automation stations modular series

IntesisBox Modbus Server Fidelio IP

DCS Data and communication server

VAV compact controller KNX / PL-Link

DCS data and communication server

IntesisBox KNX Modbus TCP master

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HCR3.2/.. Chipcard reader HOTEL SOLUTION

KNX Panasonic Air Conditioners

OZW V2.0. Web server. Synco TM, Synco TM living

IntesisBox Modbus Server SAMSUNG Air Conditioners

RRV934. Multi-controller. Synco living

OZW30. Central Unit SYNERGYR

IntesisBox KNX LG Air Conditioning

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Job Aid Pre-Installation Information S8500 Media Server

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Powerline 1200 User Manual

IntesisBox KNX - LON

OZW672...V5.2. Web-Server. For LPB/BSB plants

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

IFS SP-PoE Splitter User Manual

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

User Manual. EtherUSB

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SNMP Web Management. User s Manual For SNMP Web Card/Box

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Tracer Summit Web Server

IntesisBox KNX Modbus RTU master

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

OZW V4.0. Web server. For Synco TM, Synco TM living

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

R60 USB to CAN interface Manual (1.5 EN)

Modbus Server SAMSUNG Air Conditioners

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

VAV compact controller KNX / PL-Link

HARTING mcon 1000 Introduction and features

Input module, input/output module

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AXIS T81B22 DC 30W Midspan

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Duct Humidity Transmitter

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Wireless Router Setup Manual

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

PHOENIX CONTACT Features

Moxa EtherDevice Switch

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

PD 100A. Printing data system

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Waveguide Access Point WGA631. Product Guide

Heating Controller. Building Technologies HVAC Products

Cisco Unified IP Phone Power Injector

Product and functional description

Desigo V6.0 BACnet Router PXG3.M and PXG3.L Engineering and configuration Engineering

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BACnet. bcx1 Controller/ Router Series

EIB/KNX IP Interface with Power over Ethernet (PoE)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

CP BACnet 6FL4343-1CX10-0XE0 DESIGO S7. Used with DESIGO S7, Building Solution & Building Integration

HARTING econ 3000 Introduction and features

ORION TELECOM NETWORKS INC. T1

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Introduction. Page 2 / 9

Portable BACnet /IP to MS/TP Router

is then retained absolutely without interruption.

II Intelligent PC/CAN Interface. Manual

Remote Monitoring and REC 501 Control Unit Product Guide

ABB i-bus KNX IP Router IPR/S 2.1

Transcription:

s 9 294 Desigo PX Web interface BACnet/IP PXG3.W100 Local or remote operation of one or multiple PX automation station(s) via Desigo Touch Panels (TP) and standard web browser Ethernet connection Central user interface for simultaneous access from various operator units Central management of plant graphics and other user views Offline engineering using Xworks Plus Upload/download configuration data via LAN, or Internet LED indication for Ethernet link and activity 2-port Ethernet switch for low-cost cabling (10/100baseT) Plug-in screw terminal block for supply Operating voltage AC 24 V or DC 24 V on DIN rail mounting CM1N9294en_05 2016-06-15 Building Technologies

Use Topology The PXG3.W100 web interface is the central access point for operating the automation level. The central access point allows simultaneous operation of different operator units. It also supports integration of Desigo touch panels PXM40 / PXM50 as well as access from a standard web browser. The following operating and monitoring functions are available: Login and logout. Simple plant overview without user login. Limit view to plant level. Graphical plant operation. Alarm list to monitor alarms. System-wide alarm collection and routing. List of favorites for text-based operation of freely selectable data points. Adjustable scheduler via graphical function. Visualized trend objects (offline trend). Local settings (e.g. languages). Optimized interface for Desigo touch panels PXM40 / PXM50 for local plant operation and monitoring. Desigo Xworks Plus engineers the PXG3.W100 web interface. Ordering When ordering, please specify quantity, type, and product name. Example: Number Type (ASN) Product number (SSN) Product designation 1 PXG3.W100 S55842-Z115 BACnet/IP web interface 2 / 8

Product documentation Document type Data sheet Touch Panel PXM40, Data sheet Touch Panel PXM50 Operating instructions Desigo Touch and Web Installation and commissioning instructions Desigo Touch and Web Engineering: Online help for Desigo Xworks Plus Document no. CM1N9292 CM1N9293 CM111028 CM111029 CM111006en.chm Functions Communication Web server Web browser compatibility The web interface has a 2-port Ethernet switch for low-cost cabling on a line topology. A USB port is available for service and commissioning. The device has a web server for processing data from web pages in HTML5 from multiple Desigo PX and other BACnet IP-based devices. Date and time can be viewed via web server. See Installation and commissioning instructions Desigo Touch and Web, CM111029. LED indicators 8 7 6 5 4 3 2 1 9270Z05 LED Color Activity Function RUN Green Continuous ON Device operational Continuous OFF Min. one internal feed is in an impermissible range Flashing Device starting or program stopped FLT Red Continuous OFF OK Continuous ON HW or program fault Flashing False or corrupt firmware COM1 Yellow Flashing Sends Ethernet IP packets SVC Red Continuous OFF Configures Flashing Unconfigured Ethernet 1 / 2 Green Continuous ON Continuous OFF Flashing Yellow Continuous ON Continuous OFF Link active No connection Sends 10 or 100 Mbps Ethernet IP packets Link 100 MBit/s Link 10 MB/s Service button Button Conf. Description 1 Short Physical ID on the network (Ethernet) To reset the device to factory settings: 1. Turn off device. 2. Turn on device. 3. Wait until all LEDs turn on and then off, press the SVC button. 4. Keep SVC button pressed until the green RUN LED flashes, release the SVC button. 5. Wait until the device fully starts unconfigured (RUN-LED on, SVC LED flashes. Any device passwords and other settings are lost. 3 / 8

Mechanical design 1 Plastic housing 3 2 Plug-in terminal block (operating voltage) 4 2 2 3 2-port Ethernet switch (with 2 LEDs per port for display purposes) 4 LED display for device and system status 5 1 5 Tool interface (USB) 6 6 Service button for identification on network 9294z01 7 Slider for mounting on DIN rail 7 Notes Engineering Mounting Installation Commissioning Maintenance Firmware upgrade Repair Cable length, topology, etc.: See installation manual Desigo TRA, CM111043. The web interface is designed for mounting on a standard rail as well as on walls. The supply is connected to plug-in screw terminal blocks. Note the guidelines from the mounting and installation manual (CA110396). See installation manual Desigo TRA, CM111043. Xworks Plus is used for configuration and engineering. The online help for Xworks Plus (CM111006en.chm) as well as the installation and commissioning instructions Desigo Touch and Web CM11029en contain all the information required to configure and commission the device. Each device has a unique identification number to ensure efficient commissioning. The number is also printed on the removable barcode label. To prevent equipment damage and/or personal injuries always adhere to local safety regulations and required safety standards. PXG3.W100 is maintenance-free. The firmware can be upgraded via Ethernet and USB interface using the firmware download tool Desigo SSA-DNT. The web interface cannot be repaired. The device must be replaced as a whole. Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU (WEEE) and may not be disposed of as domestic waste. Dispose of the devices via the proper channels. Adhere to all local and currently applicable laws and regulations. 4 / 8

Technical data Power supply Power consumption Operating voltage (24V,, ) Frequency Half-wave load ( = Technical ground) At AC 24 V At DC 24 V Internal fusing External supply line protection (EU) AC 24 V ±20% (SELV) AC 24 V class 2 (US) 48...63 Hz Symmetric DC 24 V ± 20 % or Max. 9 VA Max. 4 W With PTC Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 10 A Hardware information Processor Atmel ARM9 Memory 256 MB flash, 64 MB SDRAM Response to power / communication failure Energy reserve (Supercap) to support real-time clock (3 days). Data available only if stored to flash memory. Ethernet interfaces Plug 2 x RJ45, screened Interface type 100BaseTX, IEEE 802.3 compatible Bit rate 10/100 Mbps, autosensing Protocol BACnet over UDP/IP, and HTTP or HTTPs over TCP/IP USB interface Plug Type B (USB device) Data rate (USB 1.0 full speed) 12 Mbps Galvanic isolation of No Protective switch against surges and over current Yes Connection terminals, plug-in Type Cu wire or Cu strand with wire end sleeve Cu strand without wire end sleeve Screwdriver Max. tightening torque Pluggable screw terminals 1 x 0.6 mm dia. to 2.5mm 2 or 2 x 0.6 mm dia. to 1.0 mm 2 1 x 0.6 mm dia. to 2.5 mm 2 or 2 x 0.6 mm dia. to 1.5 mm 2 Slot screws Screwdriver, size 1 with shaft dia. 4.5 mm 0.6 Nm Assignment as per EN 60730 Operation of automatic controller Degree of pollution Design type Housing protection class Protection class as per EN 60529 Front parts in the DIN section Terminal part Type 1 2 Protection class III IP30 IP20 5 / 8

Ambient conditions Operation Climatic conditions Temperature Humidity Mechanical conditions Transport Climatic conditions Temperature Humidity Mechanical conditions As per IEC 60721-3-3 Class 3K5 5... 50 C 5 95 % r.h. Class 3M2 As per IEC 60721-3-2 Class 2K3-25...70 C 5 95 % r.h. Class 2M2 Standards, directives and approvals Product safety Automatic electrical controls devices for household and similar use EN 60730-1 Electromagnetic compatibility Immunity (industry & residential) Emissions (residential) CE conformity * RCM conformity (EMC) * UL approbation UL916 Environmental compatibility Product environmental declaration (contains data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) CM1E9294 *) Color Housing RAL 7035 (light-gray) Dimensions Housing as per DIN 43880, see dimensions Weight With / without packaging 286g / 332g *) The documents can be downloaded from http://siemens.com/bt/download. Connection terminals and interfaces Connection terminals 1, 2 2 x RJ45 interface for Ethernet 3 24 V ~,, Operating voltage AC / DC 24 V USB USB tool interface 6 / 8

Dimensions All dimensions in mm 7 / 8

Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2013 Delivery and technical specifications subject to change 8 / 8