TRIAXIAL COMPRESSION TEST FOR UNDISTURBED SOILS

Similar documents
KWANG SING ENGINEERING PTE LTD

Drained and Undrained Conditions. Undrained and Drained Shear Strength

SOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

Soil Mechanics SOIL STRENGTH page 1

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

Soil Mechanics. Outline. Shear Strength of Soils. Shear Failure Soil Strength. Laboratory Shear Strength Test. Stress Path Pore Pressure Parameters

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Figure CPT Equipment

LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO

Tex-421-A, Splitting Tensile Strength of Cylindrical Concrete Specimens

Procedure for the Determination of the Permeability of Clayey Soils in a Triaxial Cell Using the Accelerated Permeability Test

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

Program COLANY Stone Columns Settlement Analysis. User Manual

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.

ALLOWABLE LOADS ON A SINGLE PILE

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

4.3 Results Drained Conditions Undrained Conditions References Data Files Undrained Analysis of

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Solid Mechanics. Stress. What you ll learn: Motivation

DryWeight BulkVolume

Impact testing ACTIVITY BRIEF

Soil Mechanics. Soil Mechanics

PILE FOUNDATIONS FM 5-134

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

COMPACTING BITUMINOUS SPECIMENS USING THE SUPERPAVE GYRATORY COMPACTOR (SGC)

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

EXPERIMENT 10 CONSTANT HEAD METHOD

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Geotechnical Testing Methods II

ANALYTICAL AND EXPERIMENTAL EVALUATION OF SPRING BACK EFFECTS IN A TYPICAL COLD ROLLED SHEET

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

8.2 Elastic Strain Energy

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

Stress Strain Relationships

Barometric Effects on Transducer Data and Groundwater Levels in Monitoring Wells D.A. Wardwell, October 2007

When to Use Immediate Settlement in Settle 3D

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

High Strain Dynamic Load Testing of Drilled Shafts

METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND

Lab 1 Concrete Proportioning, Mixing, and Testing

Introduction. ε 1 θ=55 ε 2. Localized necking Because ν=0.5 in plasticity, ε 1 =-2ε 2 =-2ε 3. ε 3,ε 2

The advantages and disadvantages of dynamic load testing and statnamic load testing

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

Standard Test Procedures Manual

Step 11 Static Load Testing

HAMBURG WHEEL-TRACKING TEST

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Proceedings 2005 Rapid Excavation & Tunneling Conference, Seattle

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

SURFACE TREATMENT BOND TEST

How To Design A Foundation

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

Dr John J M Powell Geolabs Ltd

Hollow Cylinder Apparatus (GDS SS-HCA)

Unit 24: Applications of Pneumatics and Hydraulics

The University of Toledo Soil Mechanics Laboratory

Specification Guidelines: Allan Block Modular Retaining Wall Systems

DIRECT PUSH DRILLING.

Load Frames

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles

GEOTECHNICAL DESIGN MANUAL

Module 5 Couplings. Version 2 ME, IIT Kharagpur

Cane Creek Double Barrel Instructions

Tensile Testing Laboratory

How to Design Helical Piles per the 2009 International Building Code

Stress Analysis, Strain Analysis, and Shearing of Soils

THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF MATERIALS USING THE VIBRATORY HAMMER COMPACTION

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES

Benchmarking Multi-Dimensional Large Strain Consolidation Analyses D. Priestley 1, M.D. Fredlund 2 and D. van Zyl 3

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

Standard Test Procedures Manual

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Rebuild Instructions for and Transmission

By D. P. StewarP and M. F. Randolph z

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

product manual H-4210A PORTABLE STATIC CONE PENETROMETER

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

testing equipment for quality management Programme summary. METROLOGY Tensile and Pressure Testing Machines Measuring Devices Display Devices

Technical feasibility of the reconfiguration of 8-m class telescopes

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

The University of Toledo Soil Mechanics Laboratory

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

Transcription:

Test Procedure for TRIAXIAL COMPRESSION TEST FOR UNDISTURBED SOILS TxDOT Designation: Tex-118-E Effective Date: August 1999 1. SCOPE 1.1 This method determines the unconsolidated, undrained, compressive strength of cylindrical specimens of cohesive soils in an undisturbed condition, using a straincontrolled application of the axial compression-test load where the specimen is subjected to a confining fluid pressure in a triaxial chamber. 1.2 The method provides for the measurement of the total stresses applied to the specimen, uncorrected for pore pressure. 1.3 The test provides data for determining strength properties and stress-strain relations for soils. 1.4 The values given in parentheses (if provided) are not standard and may not be exact mathematical conversions. Use each system of units separately. Combining values from the two systems may result in nonconformance with the standard. 2. DEFINITIONS 2.1 Triaxial Compression Test the triaxial compression test a test in which a cylindrical specimen of soil or rock encased in an impervious membrane is subjected to a confining pressure and then loaded axially to failure in compression. 2.2 Deviator Stress (Principal Stress Difference) Deviator stress is the difference between the major and minor principal stresses in a triaxial test, which is equal to the axial load applied to the specimen divided by the cross-sectional area of the specimen, as prescribed in the section on calculations. The major principal stress in the specimen is equal to the deviator stress plus the chamber pressure, and the minor principal stress in the specimen is equal to the chamber pressure. 2.3 Failure Stress Failure stress is the stress in the specimen corresponding to the maximum deviator stress (principal stress difference) attained, or by the deviator stress (principal stress difference) at 15% axial strain, whichever is obtained first during the performance of a test. CONSTRUCTION DIVISION 1 9 LAST REVIEWED: SEPTEMBER 2014

2.4 Unconsolidated, Undrained Compressive Strength Unconsolidated, undrained compressive strength is the value of the maximum deviator stress (principal stress difference) during the test. 3. SIGNIFICANCE AND USE 3.1 Since the shear strength of a soil is determined in terms of the total stress in this test (the total stress being equal to the effective stress plus the pore pressure), the strength depends on the pressure developed in the pore fluid during loading. 3.1.1 This method does not permit fluid flow from or into the soil specimen as the load is applied; therefore, the resulting pore pressure, and hence strength, differs from that developed in the case where drainage can occur. 3.1.2 Since this method does not permit drainage across the boundaries of the specimen, the strength measured in terms of total stress will not generally be applicable to field conditions where drainage occurs. 3.1.3 Further, the strengths determined using triaxial compression tests may not apply in cases where the strain conditions in the field differ significantly from those in the test. 4. APPARATUS 4.1 Axial-loading (compression) device, driven by either a screw jack or an electric motor through a geared transmission, plus: a platform weighing scale equipped with a screw-jack activated-load yoke; a deadweight load apparatus; a hydraulic or pneumatic loading device; or any other compression device with sufficient capacity and control to provide the rate of loading prescribed in Section 6. 4.2 Axial-load measuring device, either load ring, electronic load cell, hydraulic load cell, or any other load-measuring device capable of the accuracy prescribed in this paragraph, and may be a part of the axial loading device. 4.2.1 For soil with a deviator stress at failure of less than 96 kpa (1 ton/sq. ft.), device must be capable of measuring the unit axial load to an accuracy of 1 kpa (0.01 ton/sq. ft.) or 1% of the axial load at failure for soil with a deviator stress at failure of 96 kpa (1 ton/sq. ft.) or greater. 4.3 Chamber pressure maintaining and measurement device, capable of applying and controlling the chamber pressure to within 1 kpa (0.01 ton/sq. ft.) for chamber pressures less than 192 kpa (2 ton/sq. ft.) and to within ± 1% for chamber pressures greater than 192 kpa (2 ton/sq. ft.). 4.3.1 This device may consist of a reservoir connected to the triaxial chamber and partially filled with the chamber fluid (usually water), with the upper part of the reservoir CONSTRUCTION DIVISION 2 9 LAST REVIEWED: SEPTEMBER 2014

connected to a compressed gas supply, the gas pressure being controlled by a pressure regulator and measured by a pressure gauge, electronic pressure transducer, or any other device capable of measuring to the prescribed tolerance. 4.3.2 However, a hydraulic system pressurized by deadweight acting on a piston or any other pressure maintaining and measurement device capable of applying and controlling the chamber pressure to the tolerance prescribed in this paragraph may be used. 4.4 Triaxial compression chamber, in which the cylindrical specimen, enclosed by a membrane sealed to the specimen cap and base, may be placed and subjected to a constant hydrostatic fluid pressure. 4.4.1 The apparatus shall include a bushing and piston, aligned with the axis of the loading device. 4.4.2 The apparatus shall include a bushing and piston, aligned with the axis of the loading device. 4.4.3 The bushing and piston must be designed to minimize friction. 4.5 Impermeable rigid specimen cap and base, to prevent drainage of the specimen, constructed of a non-corrosive, impermeable material. 4.5.1 Each device shall have a circular plane surface of contact with the specimen and a circular cross section. 4.5.2 The weight of the specimen cap must be less than 0.5% of the applied axial load at failure. 4.5.3 The diameter of the cap and base must equal the initial diameter of the specimen. 4.5.4 The specimen base should be coupled to the triaxial compression chamber to prevent lateral motion or tilting. 4.5.5 The specimen cap should receive the piston so that the piston-to-cap contact area is concentric with the cap. 4.5.6 The cylindrical surface of the specimen base and cap that contacts the membrane to form a seal must be smooth and free of scratches. 4.6 Deformation indicator, a dial indicator able to measure to within 0.03% of the specimen height, with a travel range of at least 20% of the initial height of the test specimen, or other measuring device meeting these requirements for precision and range. 4.7 Rubber membrane, to encase the specimen; should provide reliable protection against leakage. 4.7.1 Discard the membrane if flaws or pinholes are evident. CONSTRUCTION DIVISION 3 9 LAST REVIEWED: SEPTEMBER 2014

4.7.2 To offer minimum restraint to the specimen, the unstretched membrane diameter should be between 75% and 90% of that of the specimen, and the thickness should not exceed 1% of the diameter. 4.7.3 The membrane must be sealed to the specimen and cap with rubber O-rings, whose unstressed inside diameter is less than 75% of the diameter of the base and cap, or by other methods that will produce a positive seal. 4.7.4 An equation for correcting the deviator stress (principal stress difference) for the effect of the strength of the membrane is given in Section 7. 4.8 Sample extruder, capable of pushing the soil core from the sampling tube with minimum disturbance. If the soil core is not extruded vertically, take care to avoid any bending. 4.9 Devices to measure the height and diameter of the specimen, capable of measuring to the nearest 0.3 mm (0.01 in.), constructed so their use will not disturb the specimen. 4.10 Timing device, indicating the elapsed testing time to the nearest 1 second, to establish the rate of strain application prescribed in Section 6. 4.11 Balance Class G1 in accordance with Tex-901-K for soil specimens less than 100 g Class G2 in accordance with Tex-901-K for specimens 100 g or heavier. 4.12 Miscellaneous apparatus, including: specimen trimming and carving tools membrane expander remolding apparatus moisture (water) content cans data sheets. 5. TEST SPECIMENS 5.1 Specimens should have a minimum diameter of 70 mm (2.8 in.) 5.1.1 The largest particle contained within the test specimen must be smaller than one sixth of the specimen diameter. 5.1.2 If oversize particles are present, indicate this information in the test data report, under remarks. 5.1.3 The height to diameter ratio should be between two and three, measured to the nearest 0.3 mm (0.01 in.) 5.2 Prepare undisturbed specimens from samples obtained from thin walled sampling tubes or other acceptable undisturbed tube sampling procedures. CONSTRUCTION DIVISION 4 9 LAST REVIEWED: SEPTEMBER 2014

5.2.1 Specimens obtained by tube sampling may be tested without trimming, except for squaring ends, provided soil characteristics are such that no significant disturbance results from sampling. 5.2.2 Handle specimens carefully to minimize disturbance, changes in cross section, or loss of moisture content. 5.2.3 If compression or any type of noticeable disturbance would be caused by the extrusion device, split the sample length-wise, or cut it off in small sections to facilitate removal of the specimen with minimum disturbance. 5.2.4 Specimens should be of uniform circular cross section, with ends perpendicular to the axis. 5.2.5 If pebbles or crumbling result in excessive irregularity at the ends, pack soil from the trimmings in the irregularities to produce the desired surface, or cap the specimens with a thin layer of plaster of Paris, hydrostone, or similar material. 5.2.6 Determine weight and dimensions of specimen, enclose in the rubber membrane, and immediately seal it to the specimen base and cap. 6. PROCEDURE 6.1 Position the specimen in the chamber and assemble the triaxial chamber 6.2 Bring the axial load piston into contact with the specimen cap several times to permit proper seating and alignment of the piston with the cap. 6.2.1 During this procedure, take care not to apply a deviator stress to the specimen exceeding 0.5% of the estimated compressive strength. 6.2.2 If the weight of the piston is sufficient to apply a deviator stress to the specimen exceeding 0.5% of the estimated compressive strength: the piston should be locked in place above the specimen cap after checking the seating and alignment; and left locked until application of the chamber pressure. 6.3 Place the chamber in position in the axial loading device. 6.4 Carefully align the axial loading device, the axial load-measuring device, and the triaxial chamber to prevent the application of a lateral force to the piston during testing. 6.5 Attach the pressure-maintaining and measurement device. 6.6 Fill the chamber with the confining fluid to a predetermined level. 6.7 Adjust the pressure-maintaining and measurement device to the desired chamber pressure and apply pressure to the chamber fluid. 6.7.1 If the axial load-measuring device is located outside the triaxial chamber, the chamber will produce an upward force on the piston that will react against the axial loading CONSTRUCTION DIVISION 5 9 LAST REVIEWED: SEPTEMBER 2014

device. In this case, start the test with piston slightly above the specimen cap, and before the piston comes in contact with the specimen cap, measure and record the initial piston friction and upward thrust of the piston produced by the chamber pressure. Later correct the measured axial load, or adjust the axial load-measuring device to compensate for the friction and thrust. 6.7.2 If the axial load-measuring device is located inside the chamber, it will not be necessary to correct or compensate for the uplift force acting on the axial loading device or for piston friction. 6.7.3 In either case, record the initial reading on the deformation indicator when the piston contacts the specimen cap. 6.8 Approximately 10 minutes after the application of chamber pressure (see Note 1) begin to apply the axial load to produce axial strain at a rate of approximately: 1%/minute for plastic materials 0.3%/minute for brittle materials that achieve maximum deviator stress at approximately 3 6% strain. 6.8.1 At these rates, the elapsed time to reach maximum deviator stress will be approximately 15 20 minutes. Note 1 The purpose of this time interval is to allow the specimen to stabilize under the chamber pressure prior to application of the load. 6.9 Record load and deformation values at approximately 0.1, 0.2, 0.3, 0.4, and 0.5% strain, and at increments of about 0.5% strain, then to 3%; and thereafter at every 1%, except that the load and deformation may be recorded at 2% increments of strain for strains greater than 10%. Take sufficient readings to define the stress-strain curve; hence, more frequent readings may be required in the early stages of the test and as failure is approached. 6.10 Continue the loading to 15% strain except: Loading may be stopped when the deviator stress has peaked and dropped 20% or When 5% axial strain occurs after a peak in deviator stress. 7. CALCULATIONS 7.1 Calculate Axial Strain ( ): = ΔL / L 0 Where: ΔL = change in length of specimen as read from deformation indicator, mm (in.) L 0 = initial length of specimen minus any change in length prior to loading, mm (in.) CONSTRUCTION DIVISION 6 9 LAST REVIEWED: SEPTEMBER 2014

7.2 Calculate the average cross-sectional area for a given applied axial load (A p ): Ap = A /( ) 0 1 7.3 Determine the principal stresses at failure: 7.3.1 Minor principal stress (σ 3 ): σ = Chamber Pr essure σ 3 And 7.3.2 Major principle stress (σ 1 ): σ 1 = Deviator Stress at Failure plus Chamber 7.4 Calculate the deviator stress for a given applied load: ( σ 1 σ 3) = P / A p Pr essure Where: A p = initial average cross-sectional area of the specimen, m 2 (in. 2 ) P = given applied axial load (corrected for uplift and piston friction, if required), kpa (psi). Note 2 If the ratio of height to diameter of the specimen is less than two, make allowance for the ratio of height to diameter by multiplying the compressive strength by the applicable correction factor listed in Table 1. Note 3 Correction of Strength Due to Stiffness of Rubber Membrane For most soils tested using membranes as prescribed in Section 4, the correction is insignificant and can be ignored; however, for the very soft soils, the membrane effect may be significant and corrections may be necessary. If making the correction, follow the procedure described in ASTM D 2850, Sections 8.5 and 8.5.1. 7.5 Graph the relationship between deviator stress (principal stress difference) and axial strain, plotting deviator stress as ordinate and axial strain as abscissa. When testing a large number of samples, failure occurs when the same stresses are obtained for three or more consecutive strain readings. 7.6 Graph the circle of stress as shown in Figure 1. CONSTRUCTION DIVISION 7 9 LAST REVIEWED: SEPTEMBER 2014

Table 1 Interpolated Specimen Strength Correction Factors H/D Factor H/D Factor H/D Factor H/D Factor 1.00 1.01 0.910 1.25 0.940 1.50 0.970 1.75 0.990 1.02 0.911 1.26 0.941 1.51 0.971 1.76 0.991 1.03 0.912 1.27 0.942 1.52 0.972 1.77 0.991 1.04 0.914 1.28 0.944 1.53 0.974 1.78 0.992 1.05 0.915 1.29 0.945 1.54 0.975 1.79 0.992 1.06 0.916 1.30.0945 1.55 0.975 1.80 0.993 1.07 0.917 1.31 0.947 1.56 0.976 1.81 0.993 1.08 0.918 1.32 0.948 1.57 0.977 1.82 0.994 1.09 0.920 1.33 0.950 1.58 0.978 1.83 0.994 1.10 0.921 1.34 0.951 1.59 0.979 1.84 0.995 1.11 0.922 1.35 0.952 1.60 0.979 1.85 0.995 1.12 0.923 1.36 0.953 1.61 0.980 1.86 0.996 1.13 0.924 1.37 0.954 1.62 0.981 1.87 0.996 1.14 0.926 1.38 0.956 1.63 0.982 1.88 0.996 1.15 0.927 1.39 0.957 1.64 0.983 1.89 0.997 1.16 0.928 1.40 0.958 1.65 0.983 1.90 0.997 1.17 0.929 1.41 0.959 1.66 0.984 1.91 0.997 1.18 0.930 1.42 0.960 1.67 0.985 1.92 0.998 1.19 0.932 1.43 0.962 1.68 0.986 1.93 0.998 1.20 0.933 1.44 0.963 1.69 0.986 1.94 0.998 1.21 0.934 1.45 0.964 1.70 0.987 1.95 0.999 1.22 0.935 1.46 0.965 1.71 0.988 1.96 0.999 1.23 0.936 1.47 0.966 1.72 0.988 1.97 0.999 1.24 0.938 1.48 0.968 1.73 0.989 1.98 0.999 0.939 1.49 0.969 1.74 0.989 1.99 1.000 2.00 1.000 CONSTRUCTION DIVISION 8 9 LAST REVIEWED: SEPTEMBER 2014

Figure 1 Mohr s Diagram 8. REPORT 8.1 Sample identification 8.2 Moisture content, wet unit weight and degree of saturation (if soaked, note degree of saturation attained). 8.3 The value of the compressive strength 8.4 Remarks Note any unusual conditions or other information that would be considered necessary to properly interpret the results obtained. CONSTRUCTION DIVISION 9 9 LAST REVIEWED: SEPTEMBER 2014