For In Vitro Diagnostic Use

Similar documents
For In Vitro Diagnostic Use

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

How To Test For Creatinine

Biochemistry Validation Form

Laboratory Procedure Manual

Intact PTH. system. Intact PTH /R5. Key to symbols used 8K25

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

TOTAL PROTEIN FIBRINOGEN

Validation and Calibration. Definitions and Terminology

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

How to Verify Performance Specifications

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

510(K) SUMMARY FEB Submitter: Name of the device: * Common Name: Clinical Chemistry Analyzer (with optional ISE Module) Attachment #2

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

HEMATOCRIT/HCT AND CALCULATED HEMOGLOBIN/HB

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Laboratory Procedure Manual

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Cold Agglutination Titer detecting Cold Reacting Antibodies

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Lab 2. Spectrophotometric Measurement of Glucose

Vitamin B12. ADVIA Centaur System

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

UNIT: Total and Direct Bilirubin

UNIT: Minerals (Calcium, Magnesium and Phosphorus) 9mine.wpd

Malondialdehyde (MDA) ELISA

Calcium. Table 1: Difference between method means in percent

A Potentiometric Analysis of Fluoride Ion in Toothpaste

TBA-FX8 Automated Clinical Chemistry Analyzer with Flexibility to Respond to Demands of Large-Scale Clinical Laboratories

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Human Free Testosterone(F-TESTO) ELISA Kit

Measurement by Ion Selective Electrodes

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

Hepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY

6 Characterization of Casein and Bovine Serum Albumin

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Bovine Vitamin B12 (VB12) ELISA Kit

Carolina s Solution Preparation Manual

ph Alkalinity of Water

Quaternary Ammonium Compounds DOC

Human Parathyroid Hormone (PTH) ELISA Kit

Determination of calcium by Standardized EDTA Solution

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

This package insert contains information to run the Creatine Kinase assay on the ARCHITECT c Systems and the AEROSET System.

Reference Range: mmol/l (arterial) mmol/l (venous) CPT Code: 83605

Med TechNet Online Services East Amherst, NY November 1997

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

URINE DIPSTICK Multistix 10SG

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Inferred ph in Steam Plant Water Chemistry Monitoring

Albumin ELISA Kit. Albumin ELISA Kit. Zur in vitro Bestimmung des Albumin in Urin und Stuhl

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Chapter 16: Tests for ions and gases

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Basic Lessons in Laboratory Quality Control

Precipitation Titration: Determination of Chloride by the Mohr Method by Dr. Deniz Korkmaz

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Tutorial 4 SOLUTION STOICHIOMETRY. Solution stoichiometry calculations involve chemical reactions taking place in solution.

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

Carcinoembryonic Antigen (CEA)

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Cancer Antigen CA 125

LIAISON XL HBsAg Quant

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY DEVICE AND INSTRUMENT TEMPLATE

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

Validation of measurement procedures

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

Chemical Reactions in Water Ron Robertson

Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

ALKALINE PHOSPHATASE

Content Sheet 5-1: Overview of Sample Management

In vitro diagnostic reagent, calibrator and control material stability

3.4 TEST FOR BACTERIAL ENDOTOXINS. Final text for revision of The International Pharmacopoeia

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

Cancer Antigen CA125 Human ELISA Kit

Standardization, Calibration and Quality Control

ph: Measurement and Uses

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

Toxoplasma gondii IgM ELISA Kit Protocol

Transcription:

SYNCHRON System(s) Chemistry Information Sheet Calcium REF & 467915 467935 REF & A28945 A28937 For In Vitro Diagnostic Use ANNUAL REVIEW Reviewed by: Reviewed by: Date Refer to coversheet in front of method PRINCIPLE INTENDED USE ISE Electrolyte Buffer reagent and ISE Electrolyte Reference reagent, when used in conjunction with SYNCHRON LX System(s), UniCel DxC 600/800 System(s) and SYNCHRON Systems AQUA CAL 1 and 2, are intended for the quantitative determination of calcium concentration in human serum, plasma or urine. CLINICAL SIGNIFICANCE Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms). Urinary calcium measurement is used in the differential diagnosis of absorptive hypercalciuria and hypercalciuria caused by hyperparathyroidism, hyperthyroidism, Paget's disease or "renal leak" type of calciuria as seen in renal tubular acidosis. METHODOLOGY The SYNCHRON System(s) determines total calcium concentration by indirect potentiometry utilizing a calcium ion selective electrode in conjunction with a sodium reference electrode. In principle, a calcium ion selective electrode measures un-bound free calcium ions in solution. Total calcium can only be calculated from free calcium when the molar ratio between free and total calcium concentrations is constant. This constant molar ratio is achieved by the buffered solution which contains strong calcium complexing agents. A precise volume of sample (40 microliters) is mixed with the buffered solution. The ratio used is one part sample to 33 parts buffered solution. The high molar strength buffer is used to establish a constant activity coefficient for calcium ions, calibrating the electrode to concentration values. 1,2 CHEMICAL REACTION SCHEME The calcium ion selective electrode consists of a calcium ionophore membrane cast on a solid support. When sample buffer mixture contacts the electrode, changes in electrode potential occur as calcium ions react with the ionophore. These changes in potential are referenced to the sodium reference electrode. The "referenced potential" follows the Nernst equation and allows the calculation of calcium concentration: 10/19/2011 1 / 12

For more accurate measurement, the reference reagent containing calcium ions is introduced into the flow cell following the sample cycle, and the same reaction scheme takes place. The differential potential (voltage) between sample and reference reagent cycles is used for the calculation. Under ideal conditions, the electrode imparts a selectivity of 1000:1 over sodium and potassium and is insensitive to hydrogen ions in solution buffered from ph 4 to 10. SPECIMEN TYPE OF SPECIMEN Biological fluid samples should be collected in the same manner routinely used for any laboratory test. 3 Freshly drawn serum, plasma or properly collected urine (random/timed) are the specimens of choice. Acceptable anticoagulants are listed in the PROCEDURAL NOTES section of this chemistry information sheet. Whole blood is not recommended for use as a sample. SPECIMEN STORAGE AND STABILITY 1. Tubes of blood are to be kept closed at all times and in a vertical position. It is recommended that the serum or plasma be physically separated from contact with cells within two hours from the time of collection. 4 2. Separated serum or plasma should not remain at room temperature longer than 8 hours. If assays are not completed within 8 hours, serum or plasma should be stored at +2 C to +8 C. If assays are not completed within 48 hours, or the separated sample is to be stored beyond 48 hours, samples should be frozen at -15 C to -20 C. Frozen samples should be thawed only once. Analyte deterioration may occur in samples that are repeatedly frozen and thawed. 4 3. It is recommended that urine assays be performed within 2 hours of collection. For timed specimens, the collection container is to be kept in the refrigerator or on ice during the timed period. 5 Urine should be acidified with 10 ml of 6N HCl added to the container before collection begins. 6 ADDITIONAL SPECIMEN STORAGE AND STABILITY CONDITIONS AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual SAMPLE VOLUME A filled 0.5 ml sample cup is the optimum volume. For optimum primary sample tube volumes in primary tube samples and minimum volumes, refer to the Primary Tube Sample Template for your system. CRITERIA FOR UNACCEPTABLE SPECIMENS Refer to the PROCEDURAL NOTES section of this chemistry information sheet for information on unacceptable specimens. 10/19/2011 2 / 12

CRITERIA FOR SAMPLE REJECTION AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual PATIENT PREPARATION SPECIAL INSTRUCTIONS FOR PATIENT PREPARATION AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual SPECIMEN HANDLING SPECIAL INSTRUCTIONS FOR SPECIMEN HANDLING AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual REAGENTS CONTENTS Each kit contains the following items: ISE ELECTROLYTE BUFFER REAGENT: Two Electrolyte Buffer Reagent Bottles (2 x 2 L) ISE ELECTROLYTE REFERENCE REAGENT: Two Electrolyte Reference Reagent Bottles (2 x 2 L) VOLUMES PER TEST Sample Volume 40 µl Reagent Volume ISE Electrolyte Buffer ISE Electrolyte Reference 1.27 ml 3.23 ml (not part of sample dilution) REACTIVE INGREDIENTS REAGENT CONSTITUENTS ISE ELECTROLYTE BUFFER REAGENT: Tris ISE ELECTROLYTE REFERENCE REAGENT: Sodium Potassium Chloride 230 mmol/l 7 mmol/l 0.2 mmol/l 5 mmol/l 10/19/2011 3 / 12

REAGENT CONSTITUENTS Carbon Dioxide 1.5 mmol/l Calcium 0.1 mmol/l Also non-reactive chemicals necessary for optimal system performance. Avoid skin contact with reagent. Use water to wash reagent from skin. MATERIALS NEEDED BUT NOT SUPPLIED WITH REAGENT KIT SYNCHRON Systems AQUA CAL 1 and 2 At least two levels of control material REAGENT PREPARATION No preparation is required. ACCEPTABLE REAGENT PERFORMANCE The acceptability of a reagent is determined by successful calibration and by ensuring that quality control results are within your facility's acceptance criteria. REAGENT STORAGE AND STABILITY 1. ISE Electrolyte Reference reagent stored unopened at room temperature is stable until the expiration date printed on the bottle label. Once opened, the reagent is stable at room temperature for 30 days, unless the expiration date is exceeded. 2. ISE Electrolyte Buffer reagent stored unopened at room temperature is stable until the expiration date printed on the bottle label. Once opened, the reagent is stable at room temperature for 30 days, unless the expiration date is exceeded. 3. For any electrolyte reagents frozen in transit, completely warm to room temperature and mix thoroughly by gently inverting bottle at least 20 times to redissolve salts into solution. ISE ELECTROLYTE BUFFER REAGENT AND ISE ELECTROLYTE REFERENCE REAGENT STORAGE LOCATION: Chemistry department, room L568. Stored on open shelves kept at room temperature monitored daily. CALIBRATION CALIBRATOR REQUIRED SYNCHRON Systems AQUA CAL 1 and 2 CALIBRATOR PREPARATION No preparation is required. CALIBRATOR STORAGE AND STABILITY 1. Unopened calibrators should be stored at +2 C to +8 C until the expiration date printed on the calibrator bottle. Once opened, the calibrators are stable at room temperature for 30 days. 2. Repetitive refrigeration of the aqueous calibrators may facilitate crystal formation. Once removed from refrigerated storage, these calibrators should remain at room temperature. 10/19/2011 4 / 12

CALIBRATOR STORAGE LOCATION: Opened Aqua Cal bottles kept at room temperature (monitored daily) in Chemistry department room L568. Unopened Aqua Cal bottles kept in Chemistry refrigerator #6 in Chemistry department room L568. CALIBRATION INFORMATION 1. The system must have a valid calibration in memory before controls or patient samples can be run. 2. Under typical operating conditions the assay must be calibrated every 24 hours or with each new bottle of reagent and also with certain parts replacement or maintenance procedures, as defined in the SYNCHRON LX Maintenance Manual and Instrument Log, or the UniCel DxC 600/800 System Instructions for Use (IFU) manual. 3. For detailed calibration instructions, refer to the SYNCHRON LX Operations Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. 4. The system will automatically perform checks on the calibration and produce data at the end of calibration. In the event of a failed calibration, the data will be printed with error codes and the system will alert the operator of the failure. For information on error codes, refer to the SYNCHRON LX Diagnostics and Troubleshooting Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. TRACEABILITY For Traceability information refer to the Calibrator instructions for use. QUALITY CONTROL At least two levels of control material should be analyzed daily. In addition, these controls should be run with each new calibration, with each new bottle of reagent, and after specific maintenance or troubleshooting procedures as detailed in the appropriate system manual. More frequent use of controls or the use of additional controls is left to the discretion of the user based on good laboratory practices or laboratory accreditation requirements and applicable laws. The following controls should be prepared and used in accordance with the package inserts. Discrepant quality control results should be evaluated by your facility. NOTICE Do not use controls containing diethylamine HCl. TABLE 1 QUALITY CONTROL MATERIAL CONTROL NAME SAMPLE TYPE STORAGE Monitrol levels 1 and 2 vials in use kept refrigerated after thawing. Unopened Monitrol kept frozen until just before use. Refer to DXC 800 Control Analysis in DXC 800 procedure manual for other control material used and storage. Control preparations and acceptance of QC results are in Policies and Procedures manual TESTING PROCEDURE(S) 1. If necessary, load the reagent onto the system. 2. After reagent load is completed, calibration is required. 10/19/2011 5 / 12

3. Program samples and controls for analysis. 4. After loading samples and controls onto the system, follow the protocols for system operations. ULATIONS The SYNCHRON System(s) performs all calculations internally to produce the final reported result. The system will calculate the final result for sample dilutions made by the operator when the dilution factor is entered into the system during sample programming. REPORTING RESULTS Equivalency between the SYNCHRON LX and UniCel DxC 600/800 Systems has been established. Chemistry results between these systems are in agreement and data from representative systems may be shown. REFERENCE INTERVALS Each laboratory should establish its own reference intervals based upon its patient population. The following reference intervals were taken from literature and a study performed on SYNCHRON Systems. 6 TABLE 2 REFERENCE INTERVALS RANGE SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Literature Serum or Plasma 8.6 10.0 mg/dl 2.15 2.50 mmol/l Urine (timed) 100 300 mg/24 hrs 2.50 7.50 mmol/24 hrs SYNCHRON Serum or Plasma 8.9 10.3 mg/dl 2.23 2.58 mmol/l RANGE SAMPLE TYPE AGE CONVENTIONAL UNITS Laboratory Serum or Plasma 0 <1 years 9.0 10.9 mg/dl >1 year - adult 8.8 10.3 mg/dl Refer to References (7,8,9) for guidelines on establishing laboratory-specific reference intervals. Note: 1. Normal range for children 0-1 year adopted from Beckman Coulter s Pediatric Reference Range Guidelines for Synchron Systems Bulletin 9345 2. Normal range for adults used for children >1 year. Beckman Coulter s Pediatric Reference Range Guidelines for Synchron Systems Bulletin 9345 for 1-3 year olds and Tietz, Fundamentals of Clinical Chemistry 5 th ed, 2001, for 2-12 year olds showed reference intervals comparable to adult range. 3. Normal range for adults was determined by testing 270 male and female healthy blood donors at UCSF. ADDITIONAL REPORTING INFORMATION AS DESIGNATED BY THIS LABORATORY: Refer to DXC800 Linearity and Reportable Range chart in Technical notes section of DXC800 Procedure manual PROCEDURAL NOTES ANTICOAGULANT TEST RESULTS If plasma is the sample of choice, the following anticoagulants were found to be compatible with this method based on a study of 20 healthy volunteers: 10/19/2011 6 / 12

TABLE 3 COMPATIBLE ANTICOAGULANTS ANTICOAGULANT LEVEL TESTED FOR IN VITRO INTERFERENCE Ammonium Heparin 14 Units/mL NSI a AVERAGE PLASMA-SERUM BIAS (mg/dl) Lithium Heparin 14 Units/mL NSI Sodium Heparin 14 Units/mL NSI LIMITATIONS 1. If urine samples are cloudy or turbid, it is recommended that they be centrifuged before transfer to a sample cup. 2. For each serum calcium measurement, the sodium concentration is used in the calculation. If sodium is not calibrated or the result is suppressed, a nominal value for sodium is used. 3. For each urine calcium measurement, the sodium and potassium concentrations are used in the calculation of the calcium concentration. If the sodium or potassium chemistries are not calibrated or the sodium or potassium results are suppressed, the calcium value will be suppressed when a urine sample is analyzed. 4. Recovery of aqueous calibrators or linearity standards, may exhibit a recovery bias since the calcium algorithms have been optimized to compute recovery of patient samples. 5. Urine Proficiency Survey samples should not be acidified. INTERFERENCES 1. The following substances were tested for interference with this methodology: TABLE 4 INTERFERENCES SUBSTANCE SOURCE LEVEL TESTED OBSERVED EFFECT b Bilirubin (unconjugated) Bovine 30 mg/dl NSI c Hemoglobin RBC hemolysate 500 mg/dl NSI Lipemia Intralipid d 500 mg/dl NSI Aluminum Aluminum Nitrate 20 mg/dl -0.2 mg/dl Bromide Lithium bromide 1 mmol/l +1.5 mg/dl Methicillin NA e 10,000 µg/ml -0.2 mg/dl Methylbenzethonium NA 0.2 mg/dl -0.2 mg/dl 2. Serum or plasma from patients receiving EDTA therapy may yield depressed calcium values. 3. Flint glass containers contain calcium and should not be used to store samples. 4. Lipemic samples with visual turbidity >3+, or with a Lipemia Serum Index >10, should be ultracentrifuged and the analysis performed on the infranate. 5. Refer to References (10,11,12) for other interferences caused by drugs, disease and preanalytical variables. 10/19/2011 7 / 12

PERFORMANCE CHARACTERISTICS Analytic Range The SYNCHRON analytical ranges: System(s) method for the determination of this analyte provides the following TABLE 5 ANALYTICAL RANGE SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Serum or Plasma 2.0 20.0 mg/dl 0.5 5.0 mmol/l Urine 2.0 30.0 mg/dl 0.5 7.5 mmol/l Samples with concentrations exceeding the high end of the analytical range should be diluted with deionized water and reanalyzed. REPORTABLE RANGE (as determined on site): TABLE 6 REPORTABLE RANGE SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Serum or Plasma 2.0 20.0 mg/dl n/a Urine 2.0 30.0 mg/dl n/a SENSITIVITY Sensitivity is defined as the lowest measurable concentration which can be distinguished from zero with 95% confidence. Sensitivity for determination is 2.0 mg/dl (0.5 mmol/l). EQUIVALENCY Equivalency was assessed by Deming regression analysis of patient samples to accepted clinical methods. Serum or Plasma (in the range of 2.19 to 20.29 mg/dl): Y (SYNCHRON LX Systems) = 0.981X + 0.17 N = 92 MEAN (SYNCHRON LX Systems) = 9.50 MEAN (SYNCHRON CX Systems) = 9.51 CORRELATION COEFFICIENT (r) = 0.996 Urine (in the range of 1.34 to 31.00 mg/dl): Y (SYNCHRON LX Systems) = 0.982X + 0.60 N = 97 MEAN (SYNCHRON LX Systems) = 13.18 MEAN (SYNCHRON CX Systems) = 12.80 CORRELATION COEFFICIENT (r) = 0.998 10/19/2011 8 / 12

Serum or Plasma (in the range of 2.0 to 19.3 mg/dl): Y (UniCel DxC Systems) = 1.007X - 0.03 N = 184 MEAN (UniCel DxC Systems) = 9.6 MEAN (SYNCHRON LX Systems) = 9.6 Correlation Coefficient (r) = 0.999 Urine (in the range of 2.1 to 30 mg/dl): Y (UniCel DxC Systems) = 0.983X + 0.09 N = 103 MEAN (UniCel DxC Systems) = 9.9 MEAN (SYNCHRON LX Systems) = 10.0 Correlation Coefficient (r) = 0.999 Refer to References (13) for guidelines on performing equivalency testing. PRECISION A properly operating SYNCHRON System(s) should exhibit imprecision values less than or equal to the maximum performance limits in the table below. Maximum performance limits were derived by an examination of the imprecision of various methods, proficiency test summaries, and literature sources. TABLE 7 MAXIMUM PERFORMANCE LIMITS TYPE OF SAMPLE TYPE 1 SD CHANGEOVER VALUE f % CV PRECISION mg/dl mmol/l mg/dl mmol/l Within-run Serum/Plasma 0.2 0.05 10.0 2.5 2.0 Urine 0.3 0.08 10.0 2.5 3.0 Total Serum/Plasma 0.3 0.08 10.0 2.5 3.0 Urine 0.45 0.11 10.0 2.5 4.5 Comparative performance data for the SYNCHRON LX System evaluated using the NCCLS Approved Guideline EP5-A appears in the table below. 14 Each laboratory should characterize their own instrument performance for comparison purposes. TABLE 8 NCCLS EP5-A PRECISION ESTIMATE METHOD TYPE OF SAMPLE TYPE No. No. Data Test Mean EP5-A Calculated IMPRECISION Systems Points g Value Point Estimates (mg/dl) SD %CV Within-run Serum Control 1 1 80 7.69 0.16 2.0 Serum Control 2 1 80 13.45 0.11 0.9 Urine Control 1 1 80 8.59 0.18 2.1 Urine Control 2 1 80 11.05 0.12 1.1 Total Serum Control 1 1 80 7.69 0.17 2.2 Serum Control 2 1 80 13.45 0.13 1.0 Urine Control 1 1 80 8.59 0.20 2.3 Urine Control 2 1 80 11.05 0.16 1.5 10/19/2011 9 / 12

NOTICE These degrees of precision and equivalency were obtained in typical testing procedures on a SYNCHRON LX System and are not intended to represent the performance specifications for this reagent. ADDITIONAL INFORMATION For more detailed information on SYNCHRON LX Systems or UniCel DxC Systems, refer to the appropriate system manual. SHIPPING DAMAGE If damaged product is received, notify your Beckman Coulter Clinical Support Center. 10/19/2011 10 / 12

REFERENCES 1. Anker, P., Wieland, E., Ammand, D., Dohner, R. E., Asper, R., Simon, W., "Neutral Carrier Based Ion-Selective Electrode for the Determination of Total Calcium in Blood Serum", Anal. Chem, 53:1970, 4 (1981). 2. Perrin, D. D., Dempsey, B., Buffers for ph and Metal Ion Control, Chapman and Hall, London (1984). 3. Tietz, N. W., "Specimen Collection and Processing; Sources of Biological Variation", Textbook of Clinical Chemistry, 2nd Edition, W. B. Saunders, Philadelphia, PA (1994). 4. National Committee for Clinical Laboratory Standards, Procedures for the Handling and Processing of Blood Specimens, Approved Guideline, NCCLS publication H18-A, Villanova, PA (1990). 5. National Committee for Clinical Laboratory Standards, Routine Urinalysis and Collection, Transportation and Preservation of Urine Specimens, Tentative Guideline, NCCLS publication GP16-T, Villanova, PA (1992). 6. Tietz, N. W., Clinical Guide to Laboratory Tests, 3rd Edition, W. B. Saunders, Philadelphia, PA (1995). 7. National Committee for Clinical Laboratory Standards, How to Define, Determine, and Utilize Reference Intervals in the Clinical Laboratory, Approved Guideline, NCCLS publication C28-A, Villanova, PA (1995). 8. Tietz, N. W., ed., Fundamentals of Clinical Chemistry, 3rd Edition, W. B. Saunders, Philadelphia, PA (1987). 9. Henry, J. B., Clinical Diagnosis and Management by Laboratory Methods, 18th Edition, W. B. Saunders Company, Philadelphia, PA (1991). 10. Young, D. S., Effects of Drugs on Clinical Laboratory Tests, 4th Edition, AACC Press, Washington, D. C. (1995). 11. Friedman, R. B., Young, D. S.,Effects of Disease on Clinical Laboratory Tests, 3rd Edition, AACC Press, Washington, D.C. (1997). 12. Young, D. S., Effects of Preanalytical Variables on Clinical Laboratory Tests, 2nd Edition, AACC Press, Washington, D. C. (1997). 13. National Committee for Clinical Laboratory Standards, Method Comparison and Bias Estimation Using Patient Samples, Approved Guideline, NCCLS publication EP9-A, Villanova, PA (1995). 14. National Committee for Clinical Laboratory Standards, Evaluation of Precision Performance of Clinical Chemistry Devices, Approved Guideline, Vol. 19, No. 2, NCCLS publication EP5-A, Villanova, PA (1999). Beckman Coulter, Inc., 250 South Kraemer Blvd., Brea, CA 92821 10/19/2011 11 / 12

ENDNOTES a NSI = No Significant Interference (within ±0.4 mg/dl or 4%). b Plus (+) or minus (-) signs in this column signify positive or negative interference. c NSI = No Significant Interference (within ±0.4 mg/dl or 4%). d Intralipid is a registered trademark of KabiVitrum, Inc., Clayton, NC 27250. e f g NA = Not applicable. When the mean of the test precision data is less than or equal to the changeover value, compare the test SD to the SD guideline given above to determine the acceptability of the precision testing. When the mean of the test precision data is greater than the changeover value, compare the test % CV to the guideline given above to determine acceptability. Changeover value = (SD guideline/cv guideline) x 100. The point estimate is based on the pooled data from one system, run for twenty days, two runs per day, two observations per run on an instrument operated and maintained according to the manufacturer's instructions. 10/19/2011 12 / 12