Bluelab Combo Meter TM Instruction Manual. combo metertm.

Similar documents
Care and use guide. Contents. page

Bluelab Soil ph Meter Instruction Manual

Care and use guide. Contents. a handy solution made easy. page

Care and use guide. Contents. a handy solution made easy. page

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

ExStik TM ph Waterproof Meters

Instruction Manual Temp 4/5/6 Temperature Meter Series

Milwaukee USER MANUAL

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

SINGLE RANGE DS METERS Operation Instructions

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Instruction Manual HI Refractometer for Sucrose Measurements

Optical Power Meter. Specification & User Manual

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

el-720 Carbon Dioxide Gas Leak Detector User s Guide

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Refer to page 6 to page 19 for detailed instructions.

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Always Moving Forward. Operating Manual. Please Read Before Operating Unit. Models DSP1, DSP2 & DSP3 Stripping Pots

digital fever alert ear thermometer suitable from birth instruction manual

PR 50 Frymaster Universal Holding Cabinet (UHC)

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Please read and keep these instructions. Run water through your machine before first use

RT-1261A Ear and Forehead Thermometer Owner s Manual

DISSOLVED OXYGEN PROBE

AIRMoN, ph and Conductivity Field Measurement

Pro1030 USER MANUAL. English

Thermistor Thermometer MODEL NO

Instant Ear Thermometer

Thermocouple Thermometer Models

User manual TAB-10C

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

DISSOLVED OXYGEN METER Model : DO-5509

Tympanic Thermometer

Touchless Forehead Thermometer

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Dissolved Oxygen Sensors

AutoRanging Digital MultiMeter

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

MAINTENANCE & TROUBLESHOOTING

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Manual Ranging MultiMeter

UltraBasic Benchtop ph Meter Operation Manual

Operator Quick Guide EC SENSOR

INSTRUCTION MANUAL. Handy Polaris

Wireless Body Scale - ibf5

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

PART 1 - INTRODUCTION...

HEART RATE + CALORIE MONITOR

Digital Photo Picture Frame. Operation Manual

Owner s Manual

Hygro-Thermometer + InfraRed Thermometer Model RH101

INTELLIHEAT HEATED UNDERBLANKET

Ground Resistance Clamp On Tester

Measuring the Conductivity of Pure Water Using USP<645>

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Portable Waterproof ph/dissolved Oxygen Meter

Soil Sensor Reader PRODUCT MANUAL

SC, FC and ST * Hot Melt Fiber Optic Connectors

Periodic Verification System Model 775PVS

Contents. Introduction... A Note About Heatsinks... Precautions...

INSTRUCTION MANUAL DTH Fax: (503)

Tassimo The Art of the Perfect Cup

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

PetSafe Spray Bark Control Collar

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

McDonald s Kitchen Cleaning Instructions. Prepared for: Employees of McDonald s

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

SCION tc DASH APPLIQUE Preparation

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Instructions and care

EK908FHL - Thermostat for floor heating

Underwater Housing for Sony RX100 III, RX100 IV

Compact Water Quality Meter B-700 series

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

Use and Care Manual. Model CPA12KH AIR CONDITIONER

OxyGuard. Dissolved Oxygen Probe

Troubleshooting Salt Generators

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Portable Air Conditioner

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Contents. Introduction... A Note About Heatsinks... Precautions...

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K

Transcription:

TM Instruction Manual combo metertm www.getbluelab.com

Table of Contents 1.0 Introduction to Bluelab Combo Meter 2 1.1 Button Functions 2 1.2 Meter Calibration 2 1.3 Storage of Meter 2 1.4 ppm Scale 2 2.0 Preparing Bluelab Combo Meter for Use 3 3.0 Measuring Hydroponic Values 4 3.1 Measure Nutrient/Conductivity 4 3.2 Measure Temperature 4 3.3 Measure ph Value 4 4.0 Changing Nutrient or Temperature Display Units 5 4.1 Change Nutrient Display Units 5 4.2 Change Temperature Display Units 5 5.0 Cleaning Probes and Meter Maintenance 6 5.1 Clean ph Probe 6 5.2 Clean Nutrient/Temperature Probe 6 5.3 Replacing Batteries 6 5.4 ph Calibration 7 6.0 Error Messages 8 7.0 Trouble Shooting Guide 9 8.0 Technical Specifications 10 Copyright, all rights reserved 1 Version 1 : 011107

1.0 Introduction to Bluelab Combo Meter The battery operated Combo Meter measures nutrient, temperature and ph levels by use of one or the other of the two probes connected to an electronic meter. The meter has a liquid crystal display (LCD) digital readout. 1.1 Button Functions 1 The function panel has three press buttons; ph/calibrate, Nutrient/Cal7.0 and Temp/Cal4/10. A short press of any button turns the meter on. The meter turns off automatically when no further buttons are pressed for a period of 4 minutes. Another short press starts it again. The meter can be manually turned off by holding the ph button down until the display starts flashing. The ph button is pressed again while the display is flashing. The buttons have a short press and long press function. A short press means a button is released in about one second. The long press is a button being pressed for at least three seconds and released when the display starts flashing. Nutrient/ Temperature Probe ph/calibrate Button Nutrient Cal 7.0 Button Reading Display Temp/Cal 4/10 Button ph Probe Figure 1. Bluelab Combo Meter 1.2 Meter Calibration 1 The ph of the meter is calibrated after each probe clean to ensure reading accuracy. Solutions used for calibration are carefully stored and replaced occasionally because ph reading accuracy is dependant on the accurracy of the calibration solutions used. If measuring a ph below 7.0 is normal, the meter is calibrated using ph7.0 and ph4.0 calibration solutions. If measuring a ph above 7.0 is normal, ph7.0 and ph10.0 solutions are used for calibration. 1.3 Storage of Meter 1 The meter is kept out of direct sunlight to prevent irreparable damage to the LCD screen; this includes storing in a cool, dry and clean place when not in use. The meter unit is not waterproof but will withstand occasional water splashes. If the meter does get splashed, it is wiped dry as soon as possible. Batteries are removed if the unit is to be stored for a prolonged period. 1.4 ppm Scale 1 In relation to the ppm scale, 500 ppm = 1.0 EC = 10 CF. Copyright, all rights reserved 2 Version 1 : 011107

2.0 Preparing Bluelab Combo Meter for Use Preparing the Bluelab Combo Meter for use involves hydrating the ph probe, inserting 2 x AAA batteries, connecting the ph probe and calibrating the ph. These tasks are performed before the meter is used for the first time. 1 Hydrate ph Probe Remove ph probe tip protective cap. Soak tip in fresh water for at least one hour. Soaking tip for 24 hours will improve the probe's activity and is recommended if the probe tip has been allowed to dry. CAUTION: Do not use de-ionized or distilled water. When probe is not in use, put some fresh water into the protective cap and place back onto probe. 2 Insert Batteries Open battery compartment by sliding back cover down and insert 2 x AAA batteries. CAUTION: Rechargeable batteries are not used as they will cause problems. OPEN Figure 2. Battery Cover 3 Replace Cover Slide cover back on. 4 Connect ph Probe Connect ph probe to meter by lining up the meter lugs and probe connector. Fasten securely by pushing probe connector on and twisting one quarter turn. Inserting Twisting Attached Figure 3. Probe Attachments 5 Clean Probes and Calibrate Cleaning of the probes is described in Section 5.1 and 5.2 of this document. Calibrating the ph is described in Section 5.4 of this document. Copyright, all rights reserved 3 Version 1 : 011107

3.0 Measuring Hydroponic Values The values measured within hydroponics by the Combo meter include nutrient (conductivity), temperature and ph levels. 3.1 Measure Nutrient/Conductivity 1 Obtain Conductivity Value Insert white nutrient/temperature probe into solution where there is strong movement of the solution, or stir the solution with the probe. Press NUTRIENT button once with a short press. Wait 1-2 minutes for probe to reach solution temperature and then read the nutrient conductivity value. NOTE: The nutrient/temperature probe is cleaned at least once a month to ensure accurate readings. If oily additives are being used the probe is cleaned after each use. Button Solution Figure 4. Nutrient Conductivity 2 Clean Probe Cleaning of the measuring probes is described in Section 5.0 of this document. 3.2 Measure Temperature 1 Obtain Temperature Value Insert white nutrient/temperature probe into solution and press TEMP button once with a short press. Wait 1-2 minutes for probe to reach solution temperature and then read temperature value. NOTE: For a change to very cold or very hot temperatures it will take 4-5 minutes for probe to reach solution temperature. To help decrease time taken to reach the solution temperature, place probe in an area where there is strong movement of solution, or stir solution with the probe. 3.3 Measure ph Value 1 Obtain ph Value Place 2 to 3cm of ph probe tip into solution and press ph button once with a short press. Wait 1-2 minutes for value to stabilize and then read ph value. NOTE: If taking readings of more than one solution, rinse the probe thoroughly in fresh water between solutions to avoid cross contamination. To decrease time taken to reach the solution temperature, place probe in an area where there is strong movement of solution, or stir solution with the probe. 2 Store Probe Store ph probe tip in a container of fresh water between uses or replace storage cap with a small amount of water in it. The ph probe is never stored in de-ionized or distilled water as this will permanently damage it. Copyright, all rights reserved 4 Version 1 : 011107

4.0 Changing Nutrient or Temperature Display Units Nutrient and temperature can be displayed in different units. The units available are shown in the tables below. 4.1 Change Nutrient Display Units 1 Set Unit Press and hold the NUTRIENT button until the display starts flashing, then release the button. 2 Select Values While display is flashing, each short button press changes units between EC, CF and ppm. The display flashes four times after the last button press and then returns back to a normal display, showing the value in the units selected. Display Nutrient Units E C EC (electrical conductivity) C F CF (conductivity factor) P ppm (parts per million) TDS (total dissolved solids) 4.2 Change Temperature Display Units 1 Set Unit Press and hold the TEMP button until the display starts flashing, then release the button. 2 Change Units Displays While display is flashing, each short button press changes units between C and F (Celsius and Fahrenheit). The display flashes four times after the last button press and then returns back to a normal display. Display Temperature Units C C (degrees Celsius) F F (degrees Fahrenheit) Copyright, all rights reserved 5 Version 1 : 011107

5.0 Cleaning Probes and Meter Maintenance Cleaning the Bluelab Combo Meter probes periodically ensures accurate readings. Cleaning includes using 'Jif', a trade name for a liquid scourer cream used in home bathrooms and kitchens. Similar products are called 'Liquid Vim' and 'Soft Scrub'. Scented varieties are never used as they affect the probe functions. Perform the following tasks to clean ph and nutrient/temperature probes. 5.1 Clean ph Probe 1 Rinse Probe Rinse off the ph probe tip and place 1-2 drops of 'Jif' onto the glassware of the probe. Do not use scented 'Jif' varieties. 2 Clean Glassware Gently scrub glassware using a clean soft toothbrush, then rinse thoroughly under running water to remove all traces of 'Jif' / cleaner. CAUTION: Do not touch probe glassware with fingers, this will contaminate the probe. 5.2 Clean Nutrient/Temperature Probe 1 Remove Shroud Dismantle by holding the body and pulling away the shroud. Figure 5 shows the shroud removed. 2 Clean Probe Face Using unscented liquid scourer such as 'Jif' or 'Soft Scrub', place one or two drops onto probe face and using a finger or Bluelab Chamois, rub firmly and vigorously to clean the probe face. Hold Figure 5. Shroud Removed Pull 3 Rinse Probe Place probe under running water. Using the same finger or other side of Bluelab Chamois, completely remove all traces of cleaner. 4 Check Probe Cleanliness Check that water forms a film on the probe face, without beads of water. If beading is present, repeat the cleaning process until the face retains a water film without beading. 5 Replace Shroud Refit the shroud firmly onto the probe face. 5.3 Replacing Batteries 1 Batteries are replaced in the unit when the message 'LO BAT' appears in top left-hand corner of LCD display. Section 2.2 in this document explains battery replacement. NOTE: Batteries are checked at least once every six months for signs of deterioration, rusting or swelling. If signs of deterioration are found, battery holder contacts are cleaned and batteries replaced. Copyright, all rights reserved 6 Version 1 : 011107

5.0 Cleaning Probes and Meter Maintenance cont. 5.4 ph Calibration For accurate meter readings the ph probe is cleaned and recalibrated frequently. The ph calibration involves cleaning the ph probe and then calibrating in two solutions. If a ph below 7.0 is being measured, use ph7.0 and ph4.0 calibration solutions. If ph above 7.0 is being measured, use ph7.0 and ph10.0 calibration solutions. If a message appears during the calibration process, such as 'e2: ph' then calibration was unreliable. Description of errors and causes are described in Section 6.0 of this document, titled 'Error Messages'. Follow these steps for meter ph calibration. 1 Clean ph Probe Clean the probe as described in Section 5.1 of this document. 2 ph7.0 Calibration Rinse probe thoroughly in fresh water, shake off excess water and place probe in a ph7.0 calibration solution for one minute or more. Once meter reading is stable, press and hold CALIBRATE button until display starts flashing. Release button and press CAL 7.0 button once. The display stops flashing when '7.0pH' is displayed. Display Flashing ph7.0 Calibration Solution Figure 6. Typical Calibration Display 3 ph4.0/ph10.0 Calibration Rinse the ph probe thoroughly in fresh water, shake off excess water and place the probe in either ph4.0 or ph10.0 calibration solution. Wait for a period of at least one minute for reading to stabilize. Press and hold CALIBRATE button until display starts flashing. Release button and press CAL 4/10 button once. The display will stop flashing with '4.0pH' or '10.0pH' displayed, depending on the solution used. The meter is now calibrated and ready for use. Copyright, all rights reserved 7 Version 1 : 011107

6.0 Error Messages Error messages can appear during calibration or when the probe or meter is damaged. The following table describes error messages, the reason and cause for an error message. To clear a calibration error message press any button once. The meter will reset to the factory set calibration and will need to be recalibrated successfully before use. Error display Indicates Possible causes E1: PH Not enough difference between ph7.0 and ph4.0 readings. ph4.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly attached, worn out or damaged. E2 : PH Not enough difference between ph7.0 and ph10.0 readings. ph10.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly attached, worn out or damaged. E3 : PH Not enough difference between the readings. Calibrate to ph7.0 FIRST, then to ph4.0/10.0. E4 : PH ph7.0 calibration unreliable. Calibrate ph7.0 calibration solution contaminated or wrong solution used. Probe contaminated, not properly attached, worn out or damaged. Copyright, all rights reserved 8 Version 1 : 011107

7.0 Troubleshooting Guide Trouble Possible reason Possible solution Nutrient readings inaccurate Contaminated probe. Clean probe as described in Section 5.0 of this document. Wait 5 to 10 minutes for reading to stabilize. Temperature readings inaccurate Temperature of probe different to solution temperature. Wait 5 to 10 minutes for probe to reach solution temperature. ph readings inaccurate Contaminated probe. Incorrect calibration. Clean ph probe as described in Section 5.0 of this document. Ensure calibration solutions are accurate. Replace if in doubt. Wait longer for readings to stabilize before calibrating. Display shows LO BAT in top left hand corner Insufficient power to take a reliable reading. Replace the batteries. DO NOT use rechargeable batteries. Meter will not turn on Batteries dead or inserted incorrectly. Check batteries are inserted correctly. Replace if necessary. Display shows E2 : PH or similar Problem with ph calibration or the meter is damaged. See error message descriptions Section 6.0 of this document. orph urph Over range ph Under range ph Solution > 14.0pH Solution < 0.0pH Check ph probe connection. ph probe could be faulty. Meter could be wet inside. or C/or F/ ur C/ ur F Over range temp Under range temp Solution >51 C/122 F Solution <0 C/32 F Conductivity probe or meter faulty. orec/orcf/or P Over range conductivity/nutrient Over range conductivity >9.9 EC, 99 CF, 1990 ppm Conductivity probe or meter faulty Copyright, all rights reserved 9 Version 1 : 011107

8.0 Technical Specifications ph Nutrient Temperature Range 0-14 ph 0-9.9 EC 0-99 CF 0-1990 ppm 0-50 C 32-122 F Resolution 0.1 ph 0.1 EC 1 CF 10 ppm 1 C 1 F Accuracy (at 25 C) + - 0.1 ph + - 0.1 EC + - 1 CF + - 50 ppm + - 1 C + - 2 F Calibration Manual Calibration Factory Calibrated Factory Calibrated Temperature Compensation Not applicable Automatic temperature compensation Not applicable Operating Temperature Range 0-45 C 32-113 F Power Source 2 x AAA Alkaline Batteries Other Features Auto turn off function Contact Details, 43 Burrows Street, PO Box 949, Tauranga, New Zealand Ph +64 7 578 0849 Fax +64 7 578 0847 Email support@getbluelab.com www.getbluelab.com Limitation of Liability: Under no circumstances shall be liable for any claims, losses, costs and damages of any nature whatsoever (including any consequential loss) that result from the use of, or the inability to use, these instructions. Copyright, all rights reserved 10 Version 1 : 011107

The instrument is only as accurate as the probe is clean! Bluelab cleaning kits Probe cleaning is one of the most important parts of owning and operating any Bluelab Truncheon, meter, monitor or controller. If the probe is contaminated (dirty), it affects the accuracy of the reading displayed. The probe surface is where the instrument takes the reading of the solution. The information is sent back from the probe to the electronic brain of the instrument. A calculation is then done in the instruments brain or micro computer and a reading is then displayed. If the information sent back from the probe is inaccurate due to probe surface contamination then the reading will be inaccurate. Cleaning the probes is a very easy task and prolongs the life of the probes. The Bluelab cleaning kits have it all there for you: ph cleaning and calibration kit: full colour instructions calibration solutions decanter vessels Bluelab probe cleaner Bluelab ph probe cleaning tool toothbrush conductivity probe cleaning kit full colour instructions conductivity standard solution decanter vessel Bluelab probe cleaner Bluelab chamois (probe cleaning instrument) Copyright, all rights reserved 11 Version 1 : 011107