Residential Fire Sprinklers and their Impact to the Fire Service System In Washington State

Similar documents
Table of Contents Introduction Page 3. Definitions Page 3. District Description Page 4. Legal existence of the fire district Page 4

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Use Of Residential Fire Sprinklers In New Housing Projects

WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

Fire Safety Risk Assessment Checklist for Residential Care Premises

10. Matters referred from the Fire Fighter Advisory Committee (FFAC), including but not limited to:

An inventory of hazardous materials used in your workplace will prove useful.

Fire and Rescue Department

Fire Code Inspector II

National Fallen Firefighter Foundation (NFFF) 16 Firefighter Life Safety Initiatives

Al-Balqa Applied University

FIRE SPRINKLER TALKING POINTS

UFF Position Statement: Fire and Smoke as a Weapon

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

NFPA Fire Fighter II

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?

STATE FIRE MARSHAL'S OFFICE

SURVIVE INSIDE: Employee Safety in Confined Spaces

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

Recommended Best Practices For Fire Department Training Programs

FREDERICK-FIRESTONE FIRE PROTECTION DISTRICT STANDARD OPERATING GUIDELINES

Implementation Date: May 5, Table of Contents. Section Description Page. 1.0 Description Initial Response 2

FIRE SERVICE PERFORMANCE MEASURES

FLA S FIRE SAFETY INITIATIVE

Fire Sprinkler Fact Sheet

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Smoke Alarm Performance in Residential Structure Fires

Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions

ACADEMIC CREDIT CLASSES

Testimony of Rhode Island Builders Association Rhode Island Building Code Standards Committee RISBC-2 State One & Two Family Code March 4, 2010

Structure Fires in Laboratories. Marty Ahrens Fire Analysis and Research Division National Fire Protection Association

notes Video User s s Guide Accident Involving Radioactive Material

FIRE INVESTIGATOR LEAD EVALUATOR HANDBOOK

United States Department of Labor Occupational Safety and Health Administration Fire Fighters' Two-in/Two-out Regulation

Fire Fighter Survival

Town of Lakeshore Fire Master Plan Final Report

Surrey Fire & Rescue Service Report of Fire

ESCAMBIA COUNTY FIRE-RESCUE

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Agenda Item # Page f BILL 141 -THE HOME FIRE SPRINKLER ACT, 2004 RECOMMENDATION

MARKETING HOMES PROTECTED BY FIRE SPRINKLER SYSTEMS

IAFC NFPA 72 Proposal Fact Sheet: Focus on Reduction of False Alarms and Support of Effective and Efficient Response

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

(2) The minimum number of members who are required to perform each function or evolution and the manner in which the function is to be performed.

Roland Garcia Pearland Fire Department

Fire Sprinkler Incentive Act of 2003

Fire and Emergency Services Guide

OCCUPATIONAL SAFETY AND HEALTH PROGRAM

MAJOR PLANNING CONSIDERATIONS CHECKLIST

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

FY 2012 PERFORMANCE PLAN Fire and Emergency Medical Services Department

Decree of the Ministry of the Environment. on fire safety of garages

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Decontamination of the victim. Protection of medical personnel. Disposing of contaminated protective equipment and wash solutions.

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

AMBULANCE STUDY COMMITTEE QUARTERLY REPORT

A Call for Fire Sprinklers in Chicago s Existing Residential High-Rises

Daycare Center Fires

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

Fire Response Plan - Code Red

Planning & Response Considerations for Mass Shooting Incidents

Dallas Fire-Rescue. FY Proposed Budget Presented to the Dallas City Council September 7, 2011

TOWN OF WAYLAND POSITION DESCRIPTION

PRE-DESIGNATED DISPATCHING. Presented by The MCCC ROG Committee

CITY OF KENT, WASHINGTON COMPREHENSIVE EMERGENCY MANAGEMENT PLAN APPENDIX 3 REFERENCES

Section 9 Major Urban Fire

PROBATIONARY FIREFIGHTER HANDBOOK

C u r r i c u l u m V i t a e Lee K. McCarthy, P.E., IAAI-CFI, CFEI Fire Protection Engineer. Professional Practice. Employment History

Chapter Fire safety 5.8.3

OPERATIONS POLICY AND PROCEDURE

FIRE SCIENCE Associate of Applied Science and Certificates

LINCOLNSHIRE FIRE AND RESCUE

Workers Compensation and Rehabilitation and other Legislation Amendment Bill 2015

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

OAKPARK SECURITY SYSTEMS LIMITED. Health & Safety Policy. Requests or suggestions for amendment to this procedure

Maryland Emergency Operations Plan

To protect the lives and property of citizens, by providing professional fire and life safety services to people in need.

FIRE SAFETY ONLINE TRAINING

Child Care Emergency Preparedness Training. Participant Manual

Elgin Fire Department

Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

The Challenges of Firefighter Training in Pennsylvania

Pinole Fire Department

How To Handle A Train Accident In Whitefish

In 1980, the National Fire Protection Association (NFPA)

SAFETY AND HEALTH PROGRAM

MSC/Circ June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Fire Following Earthquake:

Submitted By Dutchess County Emergency Response Coordinator John Murphy Date:

CODING QUESTIONS MANUAL

Title REPORTING AND FILING OF INJURIES AND DEATHS CLASSIFICATION POLICY STATEMENT

RONALD F. GRONEMEYER

CURRICULUM VITAE DENNIS E. FIELD, CFI

H O M E F I R E S P R I N K L E R S S A V E L I V E S, M O N E Y A N D W A T E R A G U I D E F O R W A T E R P U R V E Y O R S

FIRE CHIEF / ADMINISTRATOR

SECTION 903 AUTOMATIC SPRINKLER SYSTEMS

Flashover. Newsletter by Vincent Dunn-July 2000

Transcription:

Residential Fire Sprinklers and their Impact to the Fire Service System In Washington State Declaration Of Larry Rabel Captain, Strategic Planning Unit, Kent Fire Department President, Deployment Dynamics Group 9/24/2009 This white paper is prepared for the Washington Building Code Council as testimony in opposition of the amendments offered by the Washington Building Industry that would alter the residential sprinkler requirements of the 2009 International Residential Code.

Table of Contents Table of Figures... 2 Introduction... 3 Situation of Washington s Fire Service... 3 Fire Service System Concept... 4 The Problem... 5 Mitigation; the Solution... 6 Summary... 6 Closing Statement... 8 Table of Figures Figure 1 NFPA 550 Figure 4.3 Top gate of Fire Safety Concepts Tree... 5 Figure 2 Time verse Products of Combustion & Restriction of Fire Growth by Automatic Fire Sprinklers.. 7 2

Introduction Fire sprinklers are a necessary mitigation tool for Washington s fire departments. Statewide, fire departments are expected to provide adequate levels of service as called out by the State Legislature in the Growth Management Act (GMA) RCW 36.70A, the State Subdivision Code RCW 58.17, State Codes regulating cities RCW 35.103 and 35A.92, and in the State Code regulating fire districts RCW 52.33. State guidelines for fire service performance and adequacy of service utilizes benchmarks established by the National Fire Protection Association (NFPA) for fire protection. Time is the benchmark, free burning fires will double in size every minute they are allowed to burn unchecked. As a fire is allowed to burn, it gives off smoke and toxic gases and reaches a point in fire development called Flashover. Flashover is an almost explosive transition in a structure fire where all of the contents within a room instantly burst into flame and survival in the fire compartment is no longer possible even for fully protected firefighters. The time portion of adequate fire services is the race to intervene in the development of fire prior to flashover. RCW 35.103, 35A.92 and 52.33 all state that predominantly career fire departments shall establish level of service objectives that are meaningful to flashover. These same fire departments are also guided by a national set of standards established by the National Fire Protection Association (NFPA). NFPA s Standard 1710 establish level of service standards for career fire departments and NFPA 1720 establishes level of service standards for volunteer fire departments. The US Census Bureau lists Washington State as the ninth fastest growing state and projects a 46% growth rate between 2005 and 2030 1. As this period of rapid growth occurs, fire departments in Washington State will be bound to maintain levels of service. At the same time, these fire departments will see their public service role continue to expand. Today s post September 11 th 2001 Washington State firefighter is called upon to be an all hazards expert for any emergency faced by our communities. In addition to firefighting, Washington s firefighters are called upon to provide emergency medical services, auto accident extrication, hazardous materials response, homeland security planning and response, emergency management planning and response, rope rescue, water rescue, confined space rescue, and any multitudes of services that are not specifically performed by other public agencies. Today, if you need help that does not fall into the category of police response, and you call 9 1 1, it is likely that you will be sent a fire department crew to help. As a result of the public demand for these services, the burden placed upon Washington s fire service is placing an enormous strain on resources. Situation of Washington s Fire Service The US Fire Administration (USFA) published a needs assessment for fire services in the State of Washington in January of 2007 titled Washington: Four Years Later, A Second Needs Assessment of the US Fire Service. While the service burden of Washington s fire departments is increasing, the USFA report reveals the following short comings 2. 1 U.S. Census Bureau, Population Division, Interim State Population Projections, 2005. Internet Release Date: April 21, 2005 2 From Pg 4 of the USFA Assessment; 3

Shortcomings 46% of all fire stations in Washington are more than 40 years old 50% of all Washington fire engines are more than 15 years old and 74% of those are over 20 years old. 41% of all Washington fire departments cannot afford enough portable radios to equip all emergency responders. 36% of Washington s fire departments cannot afford to equip each of their on duty emergency responders with self contained breathing apparatus. 22% of Washington s fire departments cannot afford to equip each of their on duty emergency responders wearing self contained breathing apparatus with personal alert systems (PASS) devices a requirement of WAC 296 305 02017 59% of Washington s fire departments have not been able to formally train all involved firefighters, in rural areas this number goes to 89% 77% of Washington s fire departments cannot meet the health and fitness standards for firefighters established by the National Fire Protection Associations standard #1500 60% of Washington s fire stations do not have backup power. 75% of Washington s fire departments report that the risk of Wildland/Urban Interface fires falls within their jurisdictions. 20% too few firefighters, one additional fire fighter is needed for every five paid firefighters currently employed. The shortcomings cited above are symptoms of the condition of Washington s fire service. Budget weakness is the primary reason that departments have not been able to achieve the type of resources needed to comply with State WISHA and Federal OSHA laws. These shortcomings are further exacerbated by the expanding workload expectations that Washington s firefighters are now responding to. Now with the budget issues created by the nationwide economic recession, demand for service continues to rise while budget dollars decrease. If growth were to actually pay for growth, than certainly the vibrant growth in Washington State over that past several years would have yielded a better prepared fire service. Fire Service System Concept According to the Washington State Fire Marshal, Washington fire departments responded to an emergency incident every 53 seconds. Every 22 minutes a fire of some kind was responded to and every hour and a half, a structure fire was reported. Most astonishingly of the statistics is that every 3.9 hours, a deliberately set fire is reported. To handle this kind of workload with aging resources and too few firefighters in Washington State, a multi focused system must be utilized. The delivery of effective fire services can be accomplished in a number of ways but regardless of how the system is implemented, it utilized three main components; fire prevention, public education, and emergency response. The whole of the Fire Service System is only as strong as its weakest part. Like a three legged stool, if any leg supporting the weight of the load is too weak, it will fail. If emergency response resources cannot meet the demand local risk places upon them, risk must be mitigated. 4

The National Fire Protection Association s Standard 550 (NFPA 550) establishes a Fire Safety Concept Tree Figure 4.3, which shows relationships of fire prevention and fire suppression. The logic of the tree is directed toward the achievement of specific objectives and the strategies are divided into two categories: Prevent Fire Ignition and Manage Fire Impact. Following the tree and its logic, fire safety objectives can be accomplished by preventing a fire from starting or by managing the impact of fire. In theory, either prevention or management could be followed to achieve the fire safety objective. Unfortunately it is not possible to achieve perfect prevention or fire management and the principles of prevention and management are applied together to form the Fire Service System. Fire Safety Objectives Prevent fire ignition Manage Fire Impact Control heat energy sources Control source fuel interaction Control fuel Manage fire Manage exposed Control combustion process Suppress fire Control fire by construction Limit amount exposed Safeguard esposed Figure 1 NFPA 550 Figure 4.3 Top gate of Fire Safety Concepts Tree NFPA 550 goes on to describe the limitation of the Fire Safety Concepts Tree such as the inability for the tree to deal simultaneously with multiple objectives; this is found in Chapter 6 of the Standard. Chapter 6 also identifies time as an element that is not included in the Fire Safety Concepts Tree as inserted above. 6.3.1 One of the major limitations of fire safety trees is the lack of chronological sequences. Fire safety depends on the elimination of combustion products and people coexisting in the same place at the same time. That is, avoidance of fire casualties depends on the avoidance of exposure in both space and time. One can either endure a fire or escape it. To escape a fire means to move faster than the fire and its products of combustion. The temporal aspect of fire development is not represented in the Fire Safety Concepts Tree. The Problem NFPA defines two specific time objectives for fire responses; time of the first unit on scene (speed of fire attack) and time for the arrival of an effective response force (force of attack). First units on scene can 5

begin establishing a command presence, relaying information to incoming units and request additional help as needed. They may also be capable of performing an emergency rescue if the crew is large enough to conform to the requirements of WAC 296 305 for back up teams. Homeland Securities assessment of the Washington State fire service reveals3 that more than 83% of Washington fire departments cannot meet the rule for two firefighters inside a structure on fire and two outside as backup with the first arriving unit. Effective response forces for a residential structure fire, is defined by the NFPA as 15 personnel. These 15 personnel fill roles for critical tasks that must be performed to keep the fire in check and provide a reasonable chance for firefighters to affect rescue and to operate on the fire ground with a reasonable degree of safety. Assembling an effective response force is the largest problem facing Washington s fire service today. There are two reasons for this. First there are too few resources and personnel available to meet the recommendations of the NFPA and Washington State Law as identified in the Homeland Security assessment mentioned earlier. Second, the increased burden placed on today s fire departments to respond to all hazards is taxing available resources. The same problem occurs be it from problem one, too few resources or problem two, resources are busy with other incidents. In either situation, fires burn unchecked for longer periods of time until adequate resources can arrive. This further exacerbates the emergency response problem because the longer a fire has time to burn, the longer emergency units will be out of service to mitigate the problem. When these units are out of service, there are no resources to answer the next emergency. Mitigation; the Solution Where timely arrival cannot be achieved in cases of structure fires, fire prevention techniques can help mitigate the growth and spread of fire. From 2002 to 2005 the U.S. Fire Administration reported 4 a 100% decrease in fire fatalities, 57% fewer civilian injuries and 32% less property loss in single family dwelling unit s equipped with automatic fire sprinklers. Fire sprinklers automatically manage fire impact by restraining fire growth thereby allowing occupants to exit structures. The limitation of fire growth and fire spread allows for later arrival of fire suppression forces and more time to protect against the deadly consequence of flashover. In addition, fewer fire suppression forces are needed and more can remain ready to answer the next 9 1 1 call. Fire prevention tools such as automatic fire sprinkler systems and smoke alarms working together with fire safety education, and timely arrival of emergency response forces, all work together to support the fire service system and the three legged stool upon which lays the local fire department s mission of protecting life. Today s Washington State fire service is in need of help to maintain service into the future. Summary Washington s fire service cannot support the continued impacts of growth and still meet the burden of performing to the requirements of State and National standards for response performance. The aging resources and lack of personnel of Washington s fire service is clearly documented in the Homeland Security report titled, Washington; Four Years Later and the shortcomings identified in this report exist across the State in urban suburban and rural areas. Washington s fire service system needs a 3 Washington; Four Years Later, Table 3 4 National Institute of Standards and Technology report #7451, pg ES1 6

stronger presence of fire prevention to support its weakening emergency response system to protect the people of Washington State from declining levels of service. Automatic fire sprinkler systems in residential properties have proven to be effective at saving lives of both home occupants and firefighters. They have also proven to be an effective fire prevention tool capable of supporting the weak leg of emergency response. Because the behavior of fire is so different in a sprinklered occupancy as compared to a non sprinklered occupancy, far fewer emergency response resources are needed. As Washington State continues to develop faster than emergency response forces can keep up with the increased service demand, level of service will continue to degrade. The shortcomings of our current system will never be overcome without some kind of fire prevention relief on the emergency response leg of the fire service system stool. Sprinklers must be a component of the fire protection system if development is allowed to continually build faster than essential resources can be provided. Sprinkler systems in residential properties reduce the burden of emergency response on local fire department resources and assist local fire departments in meeting the requirements of Washington s level of service codes found in: o RCW 35A.92, RCW 35.103 and RCW 52.33 intent The arrival of first responders with automatic external defibrillator capability before the onset of brain death, and the arrival of adequate fire suppression resources before flash over is a critical event during the mitigation of an emergency, and is in the public's best interest. Figure 2 Time verse Products of Combustion & Restriction of Fire Growth by Automatic Fire Sprinklers 7

Sprinkler systems in residential properties support Washington s Growth Management Act (GMA) by building in fire protection that reduces the level of service drain on public facilities and services : o RCW 36.70A.020 (12) Public facilities and services. Ensure that those public facilities and services necessary to support development shall be adequate to serve the development at the time the development is available for occupancy and use without decreasing current service levels below locally established minimum standards. Sprinkler systems in residential properties support Washington s State Environmental Policy Act (SEPA): o RCW 43.21C.020 (1) The legislature, recognizing that man depends on his biological and physical surroundings for food, shelter, and other needs, and for cultural enrichment as well; and recognizing further the profound impact of man's activity on the interrelations of all components of the natural environment, particularly the profound influences of population growth, high-density urbanization, industrial expansion, resource utilization and exploitation, and new and expanding technological advances and recognizing further the critical importance of restoring and maintaining environmental quality to the overall welfare and development of man, declares that it is the continuing policy of the state of Washington, in cooperation with federal and local governments, and other concerned public and private organizations, to use all practicable means and measures, including financial and technical assistance, in a manner calculated to: (a) Foster and promote the general welfare; Sprinkler systems in residential properties support Washington s Subdivision Code: o RCW 58.17.110 (2) A proposed subdivision and dedication shall not be approved unless the city, town, or county legislative body makes written findings that: (a) Appropriate provisions are made for the public health, safety, and general welfare Closing Statement The inclusion of a requirement for automatic sprinkler systems in residential structures is the safest and most cost effective method to immediately reduce risk to the public, bolster the current deficient emergency response leg of the fire service system and appropriately protect the public health, safety and general welfare. Failure to reduce risk has a direct impact upon costs to building occupants, to the fire service community and to the taxpaying public who is ultimately responsible for funding the fire service to an adequate level of service. Reducing risk will help stop the continued level of fire service erosion happening across the State of Washington. Please support passages of the 2006 International Residential Code as submitted by the International Code Council and reject the amendments offered that would change sprinkler requirements. 8