Research on the combination of water and membranes as a sound insulation building material.

Similar documents
Measuring Sound Insulation using Deconvolution Techniques

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

Airborne Sound Insulation

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

Casa da Musica, a new concert hall for Porto, Portugal

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

THE ACOUSTICS OF THE "NUOVO TEATRO COMUNALE" IN CAGLIARI

Active noise control in practice: transformer station

Acoustical proprieties of light brick walls and its effects on flanking transmission

APPLYING VIRTUAL SOUND BARRIER AT A ROOM OPENING FOR TRANSFORMER NOISE CONTROL

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Lightweight Partition Design for Residential and Commercial Buildings

Acoustic Terms, Definitions and General Information

VIPAC ENGINEERS & SCIENTISTS

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

Acoustic analysis by computer simulation for building restoration

A COMPUTATIONAL METHOD FOR ANALYSIS AND DESIGN OF ACOUSTIC ABSORBERS AND LOW FREQUENCY TRANSMISSION LOSS

ROOM ACOUSTICS DESIGN. Room Acoustics Design Intent: Appropriate Articulation

Test Report. Nr dated Sound Absorption Coefficient in the Reverberation Room. Lammengatan 2 SE Lammhult Sweden

Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

ACOUSTIC DESIGN - ROOMS FOR SPEECH

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Acoustics of the Teatro Arcimboldi in Milano. Part 2: Scale model studies, final results

Direct and Reflected: Understanding the Truth with Y-S 3

VIRTUAL SPACE 4D PROJECT: THE ROOM ACOUSTICAL TOOL. J. Keränen, P. Larm, V. Hongisto

Design of an Acoustic Anechoic Chamber for Application in Hearing Aid Research

Sound Attenuation INTRODUCTION

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Sound absorption and acoustic surface impedance

Acoustical Design of a Conference Hall

sound reduction systems for commercial, educational and industrial environments

2016 IDEERS Rules for Graduate Teams. The List of Rule Revisions

Absorption mufflers in exhaust systems. Rolf Jebasinski. J. Eberspächer GmbH & Co. Abstract

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

Noise Control Solutions For Standby Power Generators

Effects of Different Diffuser Types on the Diffusivity in Reverberation Chambers

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

Sound Power Measurement

The Role of Acoustics in Curtain Wall Design:

Basic Concepts of Sound. Contents: Definitions db Conversion Sound Fields db ± db

AU 0920 Acoustic Insulation AU One-Third-Octave Band Center Frequency (Hz)

Acoustic Porous Materials and Their Characterisation

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

A simple method to compute aircraft noise inside dwellings

Characterization of acoustics in open offices - four case studies

Exhaust noise control case study for 2800 class locomotive

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

Contents BB93 Acoustic Design for Schools

Office acoustics. How to effectively design the room acoustics of offices. AN INFORMATION BROCHURE OF

Schindler 3300 / Schindler 5300 Information on noise and vibration.

LABORATORY MEASUREMENTS ON THE EFFICIENCY OF SOUND REDUCING FURNITURE PADS OF TYPE SILENT SOCKS

Noise. CIH Review PDC March 2012

Effects of Fiber Denier, Fiber Cross-Sectional Shape and Fabric Density on Acoustical Behavior of Vertically Lapped Nonwoven Fabrics

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Building Technology and Architectural Design. Program 4th lecture Case studies Room Acoustics Case studies Room Acoustics

Tools for building acoustics design and experimental performances

Relationship between Sound Pressure and Sound Power Levels

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

DAAD: A New Software for Architectural Acoustic Design

Acoustical Design Guidelines for HVAC Systems in Schools

Acoustic design according to room shape

Acoustic design with wall acoustic solutions

Vibration Isolation in Data Centers

How To Control Noise In A C7 Data Center Server Room

Colorcoat Technical Paper Acoustic performance of pre-finished steel cladding systems

NUMERICAL ANALYSIS FOR THE IMPROVEMENT OF A SPECIAL REVERBERATION TEST ROOM

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Windows are one of the most important components of a

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

Aircraft cabin noise synthesis for noise subjective analysis

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

STANDARD DEVIATIONS IN FIELD MEASUREMENTS OF IMPACT SOUND INSULATION. Mikko Kylliäinen

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Acoustics of indoor sports halls and gymnasia

TOP 10 NOISE CONTROL TECHNIQUES

December 14, 2004 Dear Valued Auralex Customer, Thank you for your interest in Auralex LENRDs. Before you review the attached test, we would like to

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

Convention Paper Presented at the 118th Convention 2005 May Barcelona, Spain

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

8. ACOUSTICS OF ROOMS AND ENCLOSURES

STENCA PIPE. High quality pipe insulation.

The Reflexion Filter. Manual. Electronics

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

RESPONSE TIME INDEX OF SPRINKLERS

AS COMPETITION PAPER 2007 SOLUTIONS

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Transcription:

28 September 2 October 2009, Universidad Politecnica de Valencia, Spain Alberto DOMINGO and Carlos LAZARO (eds.) Research on the combination of water and membranes as a sound insulation building material. *Arno PRONK, Roberto MAFFEI a, Heiko MARTIN b *Building Technology, Product Development Eindhoven University of Technology Den Dolech 2 5612 AZ Eindhoven, The Netherlands a.d.c.pronk@tue.nl a Building Environment Science & Technology/B:E:S:T: Department Politecnico di Milano Via Bonardi 3, 20133 Milano, Italy roberto.maffei@torrescalla.it b Acoustics Laboratory Eindhoven University h.j.martin@tue.nl; Abstract This research concerns a 200 mm thick panel filled with water. The airborne sound insulation of this panel was measured in accordance with standard ISO 140-3 [2]. Results show that the single number rating for the airborne sound insulation R w [3] for an average water layer thickness of 200 mm is 48 db. This value is comparable to the one of a 150 mm brick wall or 100 mm concrete panel. Predictions about sound insulation of the same system at different thickness and possible applications such as highway sound barrier or construction site sound barrier are presented in the following page Key words: membranes, distance fabric, sound insulation. 1.introduction Water has a higher mass compared to the one of air. This property can be useful to develop a sound insulating panel made by membrane and water only. It is well known that, nowadays, new developments in architectural free form shaped buildings lead to the design of filled multilayer membranes as façade construction (Wenmaekers et al [9]). The water between the membranes can collect or radiate heat or cold and transfer it to and from the

building service system (Pronk et al [6]). Moreover, as presented in the design competition Create a barrier of silence by Schiphol Airport, the design team Silent Blue proved that a water panel can also work as a sound barrier. The group proposed a noise barrier made by a multilayer membrane filled with water as a roof and wall structure [8]. In this context, a sound reduction of 20 db was required in the 31,5 Hz octave band for the attenuation of ground noise by airplanes. To understand the behaviour of water as a sound isolation material, tests were done in the Acoustics Laboratory of Eindhoven University. Results showed that water is a useful material in terms of sound insulation properties. The tests indicated that doubling the water layer, the weighted sound insulation index R w increases 3 db (Wenmaekers et al [9]). To show the sound insulation properties of a waterpanel a mock-up was designed and tested. The measurement set-up and result of this test are presented in the following pages. 2.1 The mock-up A panel (Figure 17) of 150 cm *125 cm *20 cm size was produced at Buitink Technology, The Netherlands. The size comes from the standardized size of the test opening for windows in the Acoustics Laboratory. The thickness of the panel follows from the distant fabric (Figure 18) used. This panel consists of two layers of membranes placed at a constant fixed distance of 20 cm. The total mass of the panel, when deflated, is 7,34 kilogram. Surface mass of one layer of membrane is therefore 1,95 kg/m 2. Figure 17 Figure 18 2.2 Testing The airborne sound insulation of water was measured in accordance with ISO standard 140-3 Laboratory measurements of airborne sound insulation of building elements [2]. The panel was placed into the vertical opening between two highly sound insulated concrete test rooms. In the first room (source room), random pink noise is produced by an amplifier with integrated noise generator (AE Amphion) and a loudspeaker (Meyvis type M4). Meanwhile the equivalent sound pressure level Leq is measured in source and receiving room with omnidirectional microphones (Type B&K 4165) on a rotating boom (16 seconds per rotation) and software DIRAC 4.1 [1]. The sound pressure level is averaged over two different loudspeaker positions. Also, the reverberation time T has been

measured by the impulse response method [4] using the same equipment and an exponential sweep signal generated by DIRAC 4.1. The average of 6 measurements with 2 loudspeaker positions and 3 microphone positions has been used for the determination of the average reverberation time. The equivalent absorption area in the receiving room 2 is evaluated using Sabine s reverberation formula (1). The sound reduction index R is calculated from equation (2). (1) (1) where: V = the volume of the receiving room, in m 3 ; T = the reverberation time in the receiving room, in s. where: R = L 1 = L 2 = S = A = the sound reduction index, in db; the average sound pressure level in the source room, in db re. 20 µpa; the average sound pressure level in the receiving room, in db re. 20 µpa; the area of the test object, in m²; the equivalent absorption area in the receiving room, in m². A supporting wooden structure with almost no sound insulation was built up on both sides to keep the panel in place (Figure 19 a-b). The panel was tested for leakage of sound by the use of a stethoscope. Several gaps were detected between the membrane and the edge of the opening due to the wrinkling of the inflatable. Foam strips were used to lose the gaps and successfully close the leakage of sound (Figure 20). Two different tests have been carried out. In the first test, the panel was filled with air and the surface mass for each panel was 1,95 kg/m 2. In the second test, the panel was filled with water and the surface mass of the whole element was 200 kg/m 2. (2) Figure 19 a-b Figure 20

3.1 Experimental results Figure 21 shows the sound reduction index as a function of frequency for one-third octave bands 50 to 5000 Hz for the 2 two tests. In Table 1 values are given for the airborne sound reduction index for the air and water panel. Also the single number ratings R w are given in accordance with ISO 717-1 [3]. Sound reduction index for air and water Ariborne sound reduction index [db] 60 50 40 30 20 10 0 63 125 250 500 1000 2000 4000 frequency [Hf] sound insulation water sound insulation air Figure 21 Sound reduction index R [db] Frequency [Hz] Air Water 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 11,7 19.9 13,5 14,6 14,5 11,7 10,8 13 13,5 14,3 13,3 13,3 17,2 21 24,8 29,1 39,8 26,2 35,9 35,1 38 40,2 39,5 41 42,9 45,7 48,5 48,9 43,3 49,1 48,9 48,8 48,4 47,8

2500 33,9 49,4 3150 4000 5000 Table 1 3.2 Discussion The sound insulation of a double membrane panel distant fabric of with a cavity of 200 mm thick (surface mass of 1,95 kg/m 2 ) filled with air is comparable to the one provided by two medium-density wooden panels of 3 mm thick (surface density of 2,1 kg/m 2 ), with an air chamber of 200 mm in-between (Figure 24). To compare the sound insulation of these panels to those of other materials, the software INSUL (Marshal Day acoustics) was used. The connections between the two membranes in the distant fabric were considered as pointconnections at a distance of 30 mm. (Figure 22) 35,9 37,3 37,1 49,5 52,6 52 R w 20 48 Figure 22 The sound insulation of water is much higher then that of air, as expected. The sound insulation curve of the water panel shown in the chart in Figure 21 shows a low sound insulation at high frequencies, probably because the water panel, above the valve level, was not completely filled in. To assure the maximum filling and have an homogeneous panel, the membrane was pierced with a needle in top part of the panel (Figure 23). Also there must have been sound leaks at the perimeter because the panel was moving in the test opening during the (continuous) filling. The single number rating measured in this test is higher than the one expected from extrapolation of the result of the previous tests (Wenmaekers et al [9]). A R w value of 45 db was expected and 48 db is the measurement result. The increase of 3 db could be a consequence of the presence of two layers of membrane (distant fabric) instead of the single layer of the previous test. This value of sound insulation for a 200 mm thick water panel (surface density of 200 kg/m 2 ) is comparable to the sound insulation of a 100 mm thick concrete wall (surface mass of 230 kg/m 2 ) or a 150 mm thick brick wall (surface mass of 250 kg/m 2 ) (Figure 24). However, in practice, a thinner layer of water (around 80-100 mm) should be used otherwise problems of stability would become relevant.

Figure 23 80 70 Ariborne sound reduction index [db] 60 50 40 30 20 10 200 mm distant fabric panel filled with water 200 mm distant fabric panel filled with air 2 mm mdf + 200 mm air +2 mm mdf 100 mm concrete wall 150 mm brick wall 0 63 125 250 500 1000 2000 4000 frequency [Hf] Figure 24 4. Conclusions The research proved that water can be used as structural (please have a look at the other paper) and sound insulating material for architectural application. Sound insulation tests demonstrate that water can work as a noise barrier for architectural applications. A 200 mm thick water panel could insulate as much as a 100 mm concrete wall. However, due to stability problems, thinner layers are preferable in practice. As a conclusion, we can sum up the advantages of using water in architectural applications: firstly, the large (heat) accumulating capacity; secondly, the capability to resist at compression; thirdly, sound insulation capacity. In addition we should mention the low price and the availability. These last two points are of great importance because they assure that this kinds of application could be used almost everywhere, as long as water is available in the surroundings.

Systems described before could be used for temporarily structures, such as pavilions, tents, and for exhibitions but also for free-form architecture. In addition, due to the availability of the material, applications in case of emergency are also possible. These kinds of solutions can be built rapidly, easily disassembled and re-used. Furthermore, only small storage accommodation is needed to store the whole elements. Acknowledgement Buitink Technology and Acoustics Laboratory of Eindhoven University played a key role in the success of this research. References [1] DIRAC 4.1 software, B&K / Acoustics Engineering. [2] ISO 140-3:1996 Laboratory measurements of airborne sound insulation of building elements. [3] ISO 717-1:1996 Rating of sound insulation in buildings and of building elements, part 1: Airborne sound insulation. [4] ISO 18233:2006 Application of new measurement methods in building and room acoustics. [5] Mehra, Schew-Ram, Aufblasbarer Schallschutz mit Bauteilen aus Folien und Membranen, in Bautechnik 79, H.11, S 794-797, 2002. [6] Pronk A.D.C., de Haas T., Cox M., Heat-Transmitting Membrane, in International conference on Textile Composites and Inflatable Structures, Barcelona, 2007. [7] Rodrigues and Coutinho, Master of Science Thesis Evaluation of the Sound Insulation of Liquid-Filled Panels, International conference paper for Internoise, Shanghai, China, 2008. [8] Schiphol Group Create a Barrier of Silence, book with presented designs, 2009. [9] Wenmaekers R:H:C, van der Aa B.A., A.D.C. Pronk, A. Couthinho, L.C.J. van Luxemberg, The sound insulation of Water, Proceedings of the NAG-DAGA Conference, Rotterdam, 2009.