LAMCO LFL FLOOR JOIST & RAFTER DESIGN GUIDE

Similar documents
POST AND FRAME STRUCTURES (Pole Barns)

Featuring TJ Rim Board and TimberStrand LSL

Chapter 6 ROOF-CEILING SYSTEMS

Residential Deck Safety, Construction, and Repair

CITY OF LOS ANGELES CALIFORNIA

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Formwork for Concrete

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

STANDARD OPEN PATIO COVER

Section A Roof Truss

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Residential Decks. Planning and Development Services Department

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Post and Beam Construction

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Uncovered Decks & Porches

PART 1 GENERAL 1.1 SECTION INCLUDES

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

BEAMCHEK EXAMPLES. RIDGE BEAM SIMPLE SPAN EXAMPLE No. 1 ACTUAL MATERIALS, LOADS AND CODE REQUIREMENTS MAY VARY. THIS IS AN ILLUSTRATION ONLY.

Structural Design for Residential Construction

NORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC JOISTTM FSC-CERTIFIED PRODUCTS AVAILABLE

INTRODUCTION STRUCTURAL DESIGN

Nanping Weishi LVL Scaffold Plank Brochure

LP OSB Sheathing & Structural 1 Sheathing

Mark Cramer Inspection Services, Inc.

Page & Turnbull imagining change in historic environments through design, research, and technology

Regional and Site Assumptions This document is based on the following regional and site assumptions:

CH. 2 LOADS ON BUILDINGS

B. Related categories: The following categories contain requirements that relate to this section:

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Common Errors in Truss Design

PERFORMANCE RATED I-JOISTS

Typical Deck Details

Patio Covers / Carports

March 14, Installation of Bay, Bow and Garden Windows

Breakaway Walls

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Bracing Webs in Trusses that have Dissimilar Configurations

TYPICAL PATIO COVERS 111

ICC-ES Evaluation Report

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Code of Standard Practice for Timber Frame Structures

6 RETROFITTING POST & PIER HOUSES

Owner s Guide to Understanding Checks in Glued Laminated Timber

Building Construction. Lightweight construction. Conventional Construction

December J-Ply Roofing, Flooring and Decking

Connection Solutions

Technical Assignment 2 TABLE OF CONTENTS

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Discipline: Structural Issued

Green Thread Product Data

CHAPTER 6 CONSTRUCTION TYPES

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Chapter 3 Pre-Installation, Foundations and Piers

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

The Analysis of Open Web Steel Joists in Existing Buildings

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Superform Products Ltd.

Guidelines for Earthquake Bracing Residential Water Heaters

6.0 Implementation: Retrofitting Gable End Walls with L-Bent Straps

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Asphalt Shingle Application Requirements

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Chapter 10 - Scaffolding Systems

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Perforated Shearwall Design Method 1

Section 5A: Guide to Designing with AAC

Ceiling Mounted Folding Attic Ladders Installation Instructions

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

HORIZONTAL INSTALLATION

Timber Frame Construction

PANELIZED HOME INSTALLATION GUIDELINE

AMERICAN GOTHIC PLAYHOUSE

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

How to secure your property after a disaster

Guidelines for Earthquake Bracing of Residential Water Heaters

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Eurocode 5: Design of timber structures

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

Transcription:

LAMCO LFL FLOOR JOIST & RAFTER DESIGN GUIDE

LAMCO-LFL GREENER EWP STRUCTURAL In any depth from 2½"-16", lengths PET d from 5-8"- 32-1 @ 1/16" increments & available in 1¼"-1½" thickness - TRUSS / FLOOR / ROOF / WALL COMPONENTS - TALLWALL STUDS (12 to... 32 ) - STRUCTURAL RIMBOARD - JOIST (Can be Toe-Nailed = less hangers req d) DESIGN SOFTWARE: CSD - istruct. MiTek version 7.2.2 & higher, ALPINE version 10.01 & higher, WoodWorks, Keymark, and soon Simpson Strong-Tie FEATURES & BENEFITS: 100% USABLE with WANE FREE EDGES Ecessive wane & large knots removed during process. LOWER MOISTURE CONTENT <14% BETTER DIMENSIONAL STABILITY Less twisting, cracking and warping. LIGHTER than regular lumber. STRONGER Design Values can substitute for 1&2, MSR & LVL to 2.0E. FLEXIBILITY for HEIGHT RESTRICTED designs. LONGER SPANS than regular lumber. EASY TO USE no special tools req d. PRE-DRILLED (available) according to user s specifications. REDUCED site WASTE, LABOR & COST. FIRE RATED ASSEMBLY LAMCO LFL is approved as a direct substitute for dimensional lumber. Made with HRA - Heat Resistant Adhesive & is a LEED certifiable product. Sold by: www.lamcoewp.com

Grade Bending, Fb (psi) Beam 6,10 Tension, Ft (psi) Compression, Fc (psi) Parallel- Parallel- Perpendicularto-Grain to-grain to-grain Design Properties Horizontal Shear, Fv (psi) Beam True 5 Modulus of Elasticity, E (10 6 psi) Modulus of Elasticity for Beam & Column Stability, Emin (10 6 psi) 1.6E 1200 1300 7 1600 425 135 1.6 0.793 1.7E 1800 1585 8 1925 595 180 1.7 0.862 1.9E 2300 1800 8 2190 675 205 1.9 0.968 2.1E 2300 2175 9 2660 675 250 2.1 1.039 1. 1 psi = 0.00689 MPa or 1 MPa = 145 psi. 2. The reference design values in this table are applicable for the product used in dry, well-ventilated interior applications, in which the equivalent moisture content of sawn lumber is less than 16%. See Section 9.3.1 of this report. 3. The reference design values in this table are for normal load duration. Loads of longer or shorter duration shall be adjusted in accordance with the applicable code. Duration of load adjustments shall not be applied to Fc, E or Emin. 4. Orientation nomenclature for Lamco LFL. y L Beam y L Plank 5. Using True (shear free) E, deflection is calculated as follows for uniformly loaded simple span beams: D = [5WL 4 /(32Ebh 3 )] + [12WL 2 /(5Ebh)] where: D = deflection in inches (mm) W = uniform load in lbs/in (N/mm) L = span in inches (mm) E = modulus of elasticity in psi (MPa) b = width of beam in inches (mm) h = depth of beam in inches (mm) 6. The bending values in these tables are based on a reference depth of 12" (305 mm). For other depths, the bending value for 1.6E grade shall be adjusted by a size factor adjustment of (12/d) 0.34, where d is measured in inches with a minimum depth of 2.5" (64 mm). For other depths of the 1.7E, 1.9E and 2.1E grades, the bending values shall be adjusted by a size factor adjustment of (12/d) 0.25 where d is measured in inches with a minimum depth of 2.5" (64 mm). Bending values are further limited to 2455 psi for 1.9E and 2795 psi for 2.1E grades. 7. The tension, Ft value for the 1.6E grade is based on a reference length of 24". For lengths up to 24', multiply Ft by KL. KL= (24/L) 0.15, where L is the length in inches. 8. The tension, Ft values for 1.7E and 1.9E grades are based on a reference length of 88" (7'4"). For lengths greater than 88", multiply Ft by KL. KL= (88/L) 0.1335, where L is the length in inches. 9. The tension, Ft value for the 2.1E grade is based on a reference length of 88" (7'4"). For lengths greater than 88", multiply Ft by KL. KL= (88/L) 0.125, where L is the length in inches. 10. When structural members qualify as repetitive members in accordance with the applicable code, a 4% increase is permitted to Fb. Assembly Detail (See Figure 1) Connection Requirements for Side - Loaded Allowable Load for Connection of Beams Loaded from One Side Only 2 Rows of 10d 3 Rows of 10d 2 Rows of (0.148" 3") (0.148" 3") ½" Bolts Nails Nails at 12" o.c. 3,7,8 at 12" o.c. at 12" o.c. Allowable Load (per side) for Connection of Beams Loaded from Both Sides 10 2 Rows of 10d 3 Rows of 10d 2 Rows of (0.148" 3") (0.148" 3") ½" Bolts Nails Nails at 12" o.c. 3,7,8 at 12" o.c. at 12" o.c. A 415 625 650 210 310 325 B 9 310 465 485 210 310 325 C 430 325 D 6 405 325 1. Multiply the appropriate table value by: a. 1.5 for nails or bolts spaced at 8" o.c. per row b. 2 for nails or bolts spaced at 6" o.c. per row c. 3 for nails or bolts spaced at 4" o.c. per row d. 0.5 for bolts spaced at 24" o.c. per row 2. Determine the appropriate beam size required to support the load before determining the connection requirements. 3. Screws can be used in place of bolts, provided additional fasteners are used such that the sum of the screw capacities is equal to or greater than that of the ½"-diameter bolts. Refer to the screw manufacturer's literature. 4. Tabulated values assume adequate end distance, edge distance and spacing per Chapter 11 of NDS. 5. Tabulated values are for normal load duration. Adjustment of the design stresses for duration of load shall be in accordance with the applicable code or NDS, as applicable. 6. For beams greater than 4-plies wide, consult a Registered Design Professional for the attachment requirements. 7. A standard cut steel washer of minimum 0.118" thickness, with a minimum outside dimension of 1⅜", is required on each side of the beam between the wood and bolt head and nut. 8. Bolted connections assume full diameter bolts with bending yield strength (Fyb) of 45,000 psi and a SG of 0.44 9. Nailing is required from both sides for 3-ply beams. 10.The allowable loads provided above for connection of beams loaded from both sides are the maimum that can be applied to each side of the beam.

F L O O R S P A N S Floor Joists 40 psf Live Load, 10 psf Dead Load, l/360 Deflection Floor Joists 40 psf Live Load, 15 psf Dead Load, l/360 Deflection Size Grade 12" 16" 19.2" 24" 12" 16" 19.2" 24" 1.6E 15-2 13-8 12-6 11-2 15-0 13-0 11-11 10-8 1.7E 15-6 14-4 13-8 12-11 15-6 14-4 13-8 12-9 1.9E 15-11 14-9 14-1 13-4 15-11 14-9 14-1 13-4 7 1 /4" 9 1 /4" 9 1 /2" 11 1 /4" 11 7 /8" 14" 16" 2.1E 16-3 15-1 14-4 13-7 16-3 15-1 14-4 13-7 1.6E 18-11 16-9 15-3 13-8 18-5 15-11 14-7 13-0 1.7E 19-4 17-11 17-1 16-1 19-4 17-11 17-1 15-9 1.9E 20-0 18-6 17-7 16-7 20-0 18-6 17-7 16-7 2.1E 20-5 18-10 17-11 16-11 20-5 18-10 17-11 16-11 1.6E 19-5 17-1 15-7 13-11 18-10 16-4 14-11 13-4 1.7E 19-10 18-4 17-6 16-6 19-10 18-4 17-6 16-2 1.9E 20-6 18-11 18-1 17-0 20-6 18-11 18-1 17-0 2.1E 20-11 19-4 18-5 17-4 20-11 19-4 18-5 17-4 1.6E 22-9 19-8 17-11 16-1 21-8 18-9 17-1 15-4 1.7E 23-3 21-6 20-5 19-3 23-3 21-6 20-5 18-8 1.9E 24-1 22-2 21-1 19-10 24-1 22-2 21-1 19-10 2.1E 24-6 22-7 21-6 20-3 24-6 22-7 21-6 20-3 1.6E 23-9 20-7 18-9 16-10 22-8 19-7 17-11 16-0 1.7E 24-6 22-7 21-6 20-3 24-6 22-7 21-6 19-7 1.9E 25-4 23-4 22-2 20-11 25-4 23-4 22-2 20-11 2.1E 25-10 23-10 22-7 21-3 25-10 23-10 22-7 21-3 1.6E 27-3 23-7 21-6 19-3 26-0 22-6 20-6 18-4 1.7E 28-7 26-4 25-1 23-7 28-7 26-4 25-1 22-8 1.9E 29-7 27-3 25-11 24-4 29-7 27-3 25-11 24-4 2.1E 30-3 27-10 26-5 24-10 30-3 27-10 26-5 24-10 1.6E 30-5 26-4 24-1 21-6 29-0 25-1 22-11 20-6 1.7E 31-8 29-11 28-5 26-8 31-8 29-11 28-5 25-5 1.9E 31-8 30-11 29-4 27-7 31-8 30-11 29-4 27-7 2.1E 31-8 31-7 29-11 28-1 31-8 31-7 29-11 28-1 SPANS The spans provided in these tables are calculated using the same as those given in the code-recognized Span Tables for Joists and Rafters and Wood Structural Design Data, both published by AF&PA. Maimum spans were computed using Allowable Stress Design (ASD) and standard engineering design formulas for simple span beams with uniformly distributed gravity loads. The calculated spans assume fully supported members, properly sheathed and nailed on the top edge of the joist. Floor applications for joists consider the effect of partial composite action with minimum of 23/32 (48/24 or 24 o.c.) glue-nailed sheathing as specified by manufacturer using 1/4 bead of 100 PSI adhesive or better meeting ASTM D 3498 applied to top of clean and dry surface of joists. If adhesive is not used: Reduce spans for 7-¼ - 9½ by 1-0 and for 11-7/8-16 by 1-6. Listed spans do not include checks for concentrated or partition loads that may be required by building codes for specific occupancy or use categories. Spans in the tables are given in feet and inches and are the maimum allowable horizontal span of the member from inside to inside of bearings. BENDING Bending design values assume a fully supported member, properly sheathed and nailed on the top edge of the joist or rafter. The repetitive member factor, Cr, of 1.04 was included due to the assumption of the installation of at least three (3) joists or rafters spaced not more than 24" on-center. The load duration factor, CD, has also been applied as appropriate. DEFLECTION Deflection may be the controlling factor in determining the member size required when appearance or rigidity is important. Control of floor vibration is another important reason to limit deflection. Deflection limits are epressed as a fraction of the span length in inches (l), and consider only live load in accordance with established engineering practice for the design of joists and rafters. COMPRESSION PERPENDICULAR-TO-GRAIN The compression perpendicular-to-grain check used to develop these span tables assumes a 2.0" bearing length to account for the end of the joist or rafter bearing on a 24 wall with a 11/2" rim board applied along the outside edge of the wall. An additional check is required for shorter bearing lengths, such as for 1.5" ledgers. SHEAR PARALLEL-TO-GRAIN (HORIZONTAL SHEAR) All uniformly distributed loads within a distance from the inside face of each support equal to the depth of the member have been ignored for determining the maimum allowable span based on horizontal shear.

F L O O R S P A N S Floor Joists 40 psf Live Load, 10 psf Dead Load, l/480 Deflection Floor Joists 40 psf Live Load, 15 psf Dead Load, l/480 Deflection Size Grade 12" 16" 19.2" 24" 12" 16" 19.2" 24" 7 1 /4" 9 1 /4" 9 1 /2" 11 1 /4" 11 7 /8" 14" 16" 1.6E 13-9 12-9 12-2 11-2 13-9 12-9 11-11 10-8 1.7E 14-1 13-0 12-5 11-9 14-1 13-0 12-5 11-9 1.9E 14-6 13-5 12-10 12-1 14-6 13-5 12-10 12-1 2.1E 14-9 13-8 13-1 12-4 14-9 13-8 13-1 12-4 1.6E 17-2 15-11 15-2 13-8 17-2 15-11 14-7 13-0 1.7E 17-7 16-3 15-6 14-8 17-7 16-3 15-6 14-8 1.9E 18-2 16-10 16-0 15-1 18-2 16-10 16-0 15-1 2.1E 18-6 17-1 16-4 15-4 18-6 17-1 16-4 15-4 1.6E 17-8 16-4 15-7 13-11 17-8 16-4 14-11 13-4 1.7E 18-1 16-8 15-11 15-0 18-1 16-8 15-11 15-0 1.9E 18-8 17-3 16-5 15-5 18-8 17-3 16-5 15-5 2.1E 19-0 17-7 16-8 15-9 19-0 17-7 16-8 15-9 1.6E 20-8 19-1 17-11 16-1 20-8 18-9 17-1 15-4 1.7E 21-2 19-6 18-7 17-6 21-2 19-6 18-7 17-6 1.9E 21-10 20-2 19-2 18-1 21-10 20-2 19-2 18-1 2.1E 22-3 20-7 19-7 18-5 22-3 20-7 19-7 18-5 1.6E 21-9 20-1 18-9 16-10 21-9 19-7 17-11 16-0 1.7E 22-3 20-6 19-6 18-5 22-3 20-6 19-6 18-5 1.9E 23-0 21-2 20-2 19-0 23-0 21-2 20-2 19-0 2.1E 23-6 21-7 20-7 19-4 23-6 21-7 20-7 19-4 1.6E 25-5 23-5 21-6 19-3 25-5 22-6 20-6 18-4 1.7E 26-0 23-11 22-9 21-5 26-0 23-11 22-9 21-5 1.9E 26-11 24-9 23-6 22-1 26-11 24-9 23-6 22-1 2.1E 27-5 25-3 24-0 22-7 27-5 25-3 24-0 22-7 1.6E 28-10 26-4 24-1 21-6 28-10 25-1 22-11 20-6 1.7E 29-6 27-2 25-10 24-3 29-6 27-2 25-10 24-3 1.9E 30-7 28-1 26-8 25-1 30-7 28-1 26-8 25-1 2.1E 31-2 28-8 27-2 25-7 31-2 28-8 27-2 25-7 Chart based upon uniform loads stated. Joist ends shall be adequately restrained to prevent rotation. Responsibility Statement The information contained herein is a product, engineering or building code evaluation performed in accordance with the referenced building code, testing and/or analysis using generally accepted engineering practices. Product, design and code compliance quality control is the responsibility of the referenced company. Consult the referenced company for the proper detailing and application for the intended purpose. Consult your local jurisdiction or design professional to assure compliance with the local building code. Qualtim, Inc. (www.qualtim.com) and SBC Research Institute (www.sbcri.info) do not make any warranty, epress or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions, or recommendations included in this report. SBCRI is very careful to maintain the confidentiality of our clients' proprietary information and testing. SBCRI's doors are locked at all times. Qualtim staff must get clearance from Qualtim's President, Vice President or Director of R&D and Industry Projects before entering or taking any visitors into the SBCRI testing facility.

ROOF RAFTER SPANS Rafters 20 psf Live Load, 10 psf Dead Load, l/240 Deflection, CD = 1.15 Size Grade 12" 16" 19.2" 24" 7 1 /4" 9¼" 9 1 /2" 11 1 /4" 11 7 /8" 14" 16" 1.6E 19-8 17-10 16-10 15-5 1.7E 20-3 18-4 17-3 16-1 1.9E 21-0 19-1 18-0 16-8 2.1E 21-6 19-7 18-5 17-1 1.6E 25-1 22-10 21-2 18-11 1.7E 25-10 23-5 22-1 20-6 1.9E 26-10 24-4 22-11 21-3 2.1E 27-5 24-11 23-6 21-10 1.6E 25-9 23-5 21-7 19-4 1.7E 26-6 24-1 22-8 21-0 1.9E 27-7 25-0 23-7 21-10 2.1E 28-2 25-7 24-1 22-5 1.6E 30-6 27-3 24-10 22-3 1.7E 31-5 28-6 26-10 24-11 1.9E 31-8 29-8 27-11 25-11 2.1E 31-8 30-4 28-7 26-6 1.6E 31-8 28-6 26-0 23-3 1.7E 31-8 30-1 28-4 26-3 1.9E 31-8 31-3 29-5 27-4 2.1E 31-8 31-8 30-2 28-0 1.6E 31-8 31-8 29-10 26-8 1.7E 31-8 31-8 31-8 31-0 1.6E 31-8 31-8 31-8 29-9 1.7E 31-8 31-8 31-8 31-8 Rafters 20 psf Live Load, 15 psf Dead Load, l/240 Deflection, CD = 1.15 Grade 12" 16" 19.2" 24" 1.6E 19-8 17-6 16-0 14-4 1.7E 20-3 18-4 17-3 16-1 1.9E 21-0 19-1 18-0 16-8 2.1E 21-6 19-7 18-5 17-1 1.6E 24-9 21-5 19-7 17-6 1.7E 25-10 23-5 22-1 20-6 1.9E 26-10 24-4 22-11 21-3 2.1E 27-5 24-11 23-6 21-10 1.6E 25-4 21-11 20-0 17-11 1.7E 26-6 24-1 22-8 21-0 1.9E 27-7 25-0 23-7 21-10 2.1E 28-2 25-7 24-1 22-5 1.6E 29-1 25-3 23-0 20-7 1.7E 31-5 28-6 26-10 24-11 1.9E 31-8 29-8 27-11 25-11 2.1E 31-8 30-4 28-7 26-6 1.6E 30-5 26-4 24-1 21-6 1.7E 31-8 30-1 28-4 26-3 1.9E 31-8 31-3 29-5 27-4 2.1E 31-8 31-8 30-2 28-0 1.6E 31-8 30-3 27-7 24-8 1.7E 31-8 31-8 31-8 30-5 1.6E 31-8 31-8 30-10 27-7 1.7E 31-8 31-8 31-8 31-8 SUPPORT REQUIREMENTS Rafters must have adequate support. Ridge beams must be installed at roof peaks with rafters bearing directly on the ridge beam or supported by hangers or framing anchors. Ceiling joists are not required when properly designed ridge beams are used. A Ridge Board may be substituted for a ridge beam when the roof slope equals or eceeds 3 in 12, ecept that ridge beams are required for cathedral ceilings. Ridge boards must be at least 1" nominal in thickness and not less than the depth of the cut end of the rafter. Rafters must be placed directly opposite each other, and ceiling joists must be installed parallel to the rafters to provide a continuous tie between eterior walls or alternatively, standard building code approved Ridge Board and Collar-Tie framing is acceptable. SPANS The spans provided in these tables were determined on the same basis as those given in the code-recognized Span Tables for Joists and Rafters and Wood Structural Design Data, both published by AF&PA. Maimum spans were computed using Allowable Stress Design (ASD) and standard engineering design formulas for simple span beams with uniformly distributed gravity loads. The calculated spans assume fully supported members, properly sheathed and nailed on the top edge of the rafter. Rafter spans do not include composite action of adhesive and sheathing. Uplift loads caused by wind also have not been considered. Spans in the tables are given in feet and inches and are the maimum allowable horizontal span of the member from inside to inside of bearings. For sloping rafters, the span is also measured along the horizontal projection. LOAD DURATION FACTOR, CD Wood has the ability to carry substantially greater maimum loads for short durations than for long durations. For rafters, the load duration factor, CD, is typically either 1.15 for two-month snow loads or 1.25 for seven-day construction loads, or 1.6 for wind load. All rafter tables are labeled to indicate the load duration factor used. Rafter spans have been evaluated for wind loads up to and including Vasd = 110 mph (Eposure B, Mean Roof Height of 30') to determine that wind does not control design. For wind greater than Vasd = 110 mph, engineered design is required.

ROOF RAFTER SPANS Rafters 30 psf Live Load, 10 psf Dead Load, l/240 Deflection, CD = 1.15 Size Grade 12" 16" 19.2" 24" 7 1 /4" 9 1 /4" 9 1 /2" 11 1 /4" 11 7 /8" 14" 16" 1.6E 17-2 15-7 14-8 13-4 1.7E 17-8 16-1 15-1 14-0 1.9E 18-4 16-8 15-8 14-7 2.1E 18-10 17-1 16-1 14-11 1.6E 21-11 19-11 18-4 16-4 1.7E 22-6 20-6 19-3 17-11 1.9E 23-5 21-3 20-0 18-7 2.1E 24-0 21-10 20-6 19-0 1.6E 22-6 20-5 18-8 16-9 1.7E 23-2 21-0 19-9 18-4 1.9E 24-1 21-10 20-7 19-1 2.1E 24-8 22-5 21-1 19-7 1.6E 26-8 23-7 21-6 19-3 1.7E 27-5 24-11 23-5 21-9 1.9E 28-6 25-11 24-4 22-7 2.1E 29-2 26-6 24-11 23-2 1.6E 28-2 24-8 22-6 20-2 1.7E 28-11 26-3 24-9 23-0 1.9E 30-1 27-4 25-9 23-10 2.1E 30-10 28-0 26-4 24-5 1.6E 31-8 28-3 25-10 23-1 1.7E 31-8 31-0 29-2 27-1 1.9E 31-8 31-8 30-4 28-2 2.1E 31-8 31-8 31-0 28-10 1.6E 31-8 31-7 28-10 25-9 1.7E 31-8 31-8 31-8 30-11 Rafters 30 psf Live Load, 15 psf Dead Load, l/240 Deflection, CD = 1.15 Grade 12" 16" 19.2" 24" 1.6E 17-2 15-5 14-1 12-7 1.7E 17-8 16-1 15-1 14-0 1.9E 18-4 16-8 15-8 14-7 2.1E 18-10 17-1 16-1 14-11 1.6E 21-10 18-11 17-3 15-5 1.7E 22-6 20-6 19-3 17-11 1.9E 23-5 21-3 20-0 18-7 2.1E 24-0 21-10 20-6 19-0 1.6E 22-4 19-4 17-8 15-9 1.7E 23-2 21-0 19-9 18-4 1.9E 24-1 21-10 20-7 19-1 2.1E 24-8 22-5 21-1 19-7 1.6E 25-8 22-3 20-4 18-2 1.7E 27-5 24-11 23-5 21-9 1.9E 28-6 25-11 24-4 22-7 2.1E 29-2 26-6 24-11 23-2 1.6E 26-10 23-3 21-3 19-0 1.7E 28-11 26-3 24-9 23-0 1.9E 30-1 27-4 25-9 23-10 2.1E 30-10 28-0 26-4 24-5 1.6E 30-9 26-8 24-4 21-9 1.7E 31-8 31-0 29-2 26-10 1.9E 31-8 31-8 30-4 28-2 2.1E 31-8 31-8 31-0 28-10 1.6E 31-8 29-9 27-2 24-4 1.7E 31-8 31-8 31-8 30-2 Chart based upon uniform loads stated. Joist ends shall be adequately restrained to prevent rotation.

TALL WALLS & TRUSSES LAMCO LFL SOLD THE JOB! A contractor came to us with plans. Originally, due to the long spans, he had planned to use Lamco LFL for rafters. The more we looked at the plan, the more we realized that we could use trusses for this project using relam in the bottom cord of the truss and accomplish what the customer wanted. The plan called for a 32-0 room, which cannot be designed using dimensional lumber. It was also cost prohibitive to use LVL material. LAMCO s 2.1E LFL sold the job, and the contractor is very pleased. He also ended up using the LFL for headers on all the porches, which again, was more cost effective than using LVL s for the beams. The contractor is sold on the product, and has already ordered it for headers on another job that is starting net week! Picture & Testimonial provided by Sam Yoder & Son of Delaware. LAMCO products distributed by: For more information: www.lamcoewp.com St-Félicien (QC) Canada Certified by: PFS Corporation - 2402 Daniels Street, Madison, WI 53718 Telephone: (608) 221-3361 Fa: (608) 221-0180