Assessment of Wastewater Treatment Plant s Performance in Amol Industrial Park

Similar documents
OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

WASTEWATER TREATMENT OBJECTIVES

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Phosphorus Removal. Wastewater Treatment

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

Sewerage Management System for Reduction of River Pollution

Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

PROPAK AquaBio Complete Water Restoration Systems

Wastewater Nutrient Removal

Biological Phosphorus Removal Activated Sludge Process in Warm Climates

Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and

Planning, Designing, Monitoring and Inspection of Wastewater Treatment Systems of Industries

GUIDELINES FOR LEACHATE CONTROL

POTW PHOSPHORUS REMOVAL PROCESSES

Saudi Aramco Project Development

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Module 17: The Activated Sludge Process Part III

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

Appendix 2-1. Sewage Treatment Process Options

Choosing an Effluent Treatment Plant

Example Calculations Evaluation for Fine Bubble Aeration System. Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA

Biological Wastewater Treatment

Engineers Edge, LLC PDH & Professional Training

aquateam Aquateam - Norwegian Water Technology Centre A/S Report no: Project no: O Project manager: Dr. Bjørn Rusten.

Glossary of Wastewater Terms

Best Practice Guide NO. BPGCS002. Wastewater Treatment Activated Sludge Process

WEFTEC.06. *Corresponding author Department of Civil and Environmental Engineering, The University of Western Ontario

ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT

TABLE OF CONTENTS 2. PHOSPHORUS AND NITROGEN IN WASTEWATER 3. PHOSPHORUS AND NITROGEN REMOVAL MECHANISM 4. PROCESS REQUIREMENT AND CONTROL FACTOR

Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

HUBER Vacuum Rotation Membrane VRM Bioreactor

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

Appendix F Use of spill basin to further reduce final effluent variability - report

Small Wastewater Treatment Systems

1 Environmental Leverage Inc Dogwood Dr. Suite A, North Aurora, IL EnvironmentalLeverage.com

SECONDARY TREATMENT ACTIVATED SLUDGE

City of Lakeland s Wetlands Treatment System An Overview

Operation and Maintenance of Onsite Waster Systems in Maryland. A growing challenge for the industry and regulators

Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD

WASTEWATER TREATMENT

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

Removing Heavy Metals from Wastewater

Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence

Phosphorus Removal. P.F. Strom, 2006; do not copy without written permission.

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

On-site Treatmentt for Domestic Wastewater in Thailand Suwanna. K. Boontanon Mahidol Univ. 2

ANAEROBIC/ANOXIC TANKS

Advanced Wastewater Treatment Process

Treatment of dairy wastewater by natural coagulants

Town of New Castle Utility Department Introduction

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Alternative Options to Large Scales of Domestic Wastewater Treatment Facilities Management in Thailand

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Application Form 2E. Facilities Which Do Not Discharge Process Wastewater

COD/BOD 5 Reduction with ROTAMAT Fine and Micro Screens

Water and Wastewater. Sample Collection and Analysis

REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS

MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC

Phosphorus Removal in Wastewater Treatment

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB

Recycle treated effluent to meet looi of the facility's non-potable water needs. nutrient removal and activated carbon adsorption.

Enhancing Nitrification in an Oil Refinery WWTP with IFAS

ENGINEERING REPORT Sewage Treatment System

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Unit 1. Physical, chemical and biological Characteristics of Wastewater

UASB reactor for domestic wastewater treatment at low temperatures: a comparison between a classical UASB and hybrid UASB-filter reactor

CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS

Bioremediation. Introduction

ACTIFLO Process For Wet Weather and Wastewater Treatment


Chemistry at Work. How Chemistry is used in the Water Service

BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

Energy Consumption in Wastewater Treatment Plants in China Xie Tao, 1 Wang Chengwen, 1

NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

Ion Exchange Softening

Facility Classification Standards

1.3 Wastewater and Ambient Water Quality

Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection

William E. Dunn Water Reclamation Facility. Facility Overview & Information

Aeration Efficiency Guide

Cambridge Wastewater Treatment Facility

Virginia Street Tree Box Filters Demonstration Project

Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009

Research Article. Removal of nitrogen and phosphorus from municipal wastewater using intermittent cycle moving bed biofilm reactor (ICMBBR)

Florida Department of Environmental Protection

Sewage Discharge in Estuaries: The case for Trapping.

Orange County Sanitation District

NAJAFGARH DRAIN-SAMPLING AND ANALYSIS

ANAEROBIC TREATMENT FOR SANA'A WASTEWATER USING UASB REACTOR PILOT PLANT

ADDENDUM TO THE FACT SHEET FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. WA June 25, 2010

Transcription:

American-Eurasian J. Agric. & Environ. Sci., 5 (5): 707-711, 2009 ISSN 1818-6769 IDOSI Publications, 2009 Assessment of Wastewater Treatment Plant s Performance in Amol Industrial Park 1 2 3 aedeh Sadeghpoor, Bahar Hosseini and Ghasem D. Najafpour 1 Faculty of Engineering, Islamic Azad University of Qaemshahr, Iran 2 Environmental Engineering, Faculty of Civil Engineering, Noshirvani University of Technology, Babol, Iran 3 School of Chemical Engineering, Noshirvani University of Technology, Babol, Iran Abstract: Amol's industrial wastewater treatment plant (WWTP) was monitored over a period of (July 2005 and February 2006). Also the operating conditions were optimized for 1 month to enhance the process efficiency. The problems associated with WWTP were chemical shock (strong acidic influent), bulking and rising of sludge, low ratio and ratio, inadequate mixing in the equalization tank and F LVSS inappropriate C/N/P ratio in anaerobic and aerobic tanks. Based on diagnosis of the anaerobic process, for the revival of anaerobic microbial consortium in the anaerobic digestion tank, fresh manure was added and F ratio was adjusted and then a 15% increase in removal efficiency was resulted. Addition of urea and phosphate into the aerobic tank has slightly improved on total removal efficiency (about 5%). The effluent COD concentration was reduced by 50%. Activated sludge and sludge volume indices were enhanced by 15% and 30%, respectively. Key words:industrial wastewater Activated sludge Biological treatment icrobial consortium Dissolved oxygen Abbreviations: SVI = Sludge Volume Index LVSS = ixed Liquor Volatile Suspended Solids = ixed Liquor Suspended Solids C/N/P = Carbon/Nitrogen/Phosphorous INTRODUCTION ph has to be maintained at a fixed value by addition of acid and alkali solutions. Precise control of the ph is then It has been projected that in near future, the number required, and for this purpose the use of an automated of small-scale treatment plants such as the one presently control system is essential [3]. operates in Amol (Iran), may gradually increase and a Amol industrial zone collecting all the wastewater large demand for information on appropriate procedures from several industrial plants such as poultry processing and technologies has to develop. The technical plant, meat and fruit juice processing plant, paperboard alternatives ranging from mechanical and simple biological factory, dairy farm products, glass factory, tomato low rate systems such as ponds, sand filters and reed cannery and many more small plants which are located in beds to complex high-rate suspended and fixed film 20 hectares of pasture land, generating a discharge flow biomass reactors have to be evaluated according to their 3 rate of 350 to 400 m per day. plant size, operation safety, reliability, demand for skilled The wastewater selected for the present research personnel, investment and operation costs [1]. was obtained from Amol industrial-zone treatment any small-scale municipal treatment plants are in plant. This plant is located at a distance of 10 km operation in European communities but a great number from Amol, Iran. Beside the plant, a small research lab of them are not working with high performance [2]. In was assigned to monitor the performance of the plant. general, process design should aim to optimize the This plant site was selected because of the short distance reaction kinetics so that the desired reaction is completed and also it was more convenient for sampling and analysis with in minimum time. This often requires that the reaction of samples. Corresponding Author: Dr. Ghasem D. Najafpour, School of Chemical Engineering, Noshirvani University of Technology, Babol, Iran 707

Fig. 1: Schematic diagram of Amol's wastewater treatment plant Significant variations in the composition of the such as enhancing the process efficiency of the aerobic wastewater arising from a cluster of industries have and anaerobic processes. The work was focused on created difficulties in ensuring the efficiency and operation of the activated sludge process for the removal effectiveness of the WWTP. Other factors that contribute of the pollutants from Amol industrial wastewater plant. in affecting the efficiency are temperature, flow of wastewater, PH and presence of different components [4]. ATERIALS AND ETHODS The wastes consist of solid and liquid parts. The solids were removed from wastewater by screening and grit Industrial wastewater for the present research removal chamber. Wastewater was sent to degreasing was selected from Amol industrial zone. The process unit to remove oil and grease and then pumped to an parameters were dissolved oxygen (DO), chemical oxygen equalization tank to regulate the ph level of the demand (COD), turbidity, optical cell density at a wastewater. Then, wastewater was channeled to a wavelength of 520 nm, total solids, total suspended solids biological unit operation. This unit consisted of two (TSS), settle able solids, oil and grease, ph value, total anaerobic tanks including plastic media and two aerobic alkalinity and total Kjedahl nitrogen (TKN). All of the tanks. Biofilm processes have proved to be reliable for testing materials and methods used in this research is organic carbon and nutrient removal and are without based on Standard ethods for the Examination of Water some of the problems associated with activated sludge and Wastewater by APHA and AWWA unless is stated processes [5]. otherwise [6]. The plant is using extended aeration system in aeration part. Conventional activated sludge and extended RESULTS AND DISCUSSION aeration had higher removal efficiencies for ammonia, TSS, COD and BOD 5 and produced good quality final effluents This plant was sometimes suffered from high organic for ultimate disposal in accordance with the discharge load and chemical shocks. The mixers in equalization tank standard [6]. After biological treatment, biological mixture were not performed well. The ph for influent was varies, is discharged to a sedimentation tank. Sludge is settled it was in the range of 4-8. The treatment plant s effluent and the treated effluent is discharged to the chlorination normally had ph of 6.5. The ph of equalization tank was tank and then to a branch of Haraz river near the plant. 5-7. In addition, there was no ph control, such as addition A simplified scheme of the plant is presented in Figure 1. of basic material like NaOH to increase ph value if acid The present investigation was conducted in order industrial influent was introduced as intake. Often, the to enhance the efficiency of the treatment plant. The inlet wastewater was almost acidic, even sometimes the purpose of this research was to achieve certain objectives ph value in the equalization tank was detected as low 708

Fig. 4: The stability of the LVSS ratio for the duration of Fig. 2: onitored ph values for the duration of Fig. 5: The F ratio observation for the duration of Fig. 3: onitored COD removal for the duration of The high ratio of LVSS in activated sludge system may as 4. Inlet equalization tank and outlet ph values for cause bulking. According to recommendation suggested duration of are presented in Figure 2. That was by Arsivala for wastewater treatment, at ambient due to anaerobic bacteria death and the microbial film was conditions similar to Amol waste treatment plant, the F detached from the media. It should be understood that ratio should be in the range of 0.1 to 0.2 [9]. anaerobic bacteria activities decreased at low ph value Figure 5 depicts that the food and microbe ratio at (any ph lower than 6) [7, 8]. most of the time was lower than 0.1, even number of data The C/N/P ratio in anaerobic processes should be points showed zero value. That means the system held on 300-400/5/1. But measurements showed that the sometime suffered from limited amount food and the ratio was not sustained in Amol WWTP. Total Nitrogen organisms have decayed. The SVI values which are in anaerobic inlet was about 1.7 mg/l and phosphorus shown in Figure 6 are in the range of 100-45. The SVI amount was about 3 mg/l. The anaerobic removal value above 150 ml/g is associated with bulking [10]. The efficiency of the plant was low, an averaged value of average SVI was about 250. The SVI shows that at most 40%. The removal efficiency for aerobic process was of the time, the process was not efficiently operated. about 80%. The COD removal of aerobic and anaerobic Bulking is a wide phenomenon in activated sludge processes is shown in Figure 3. treatment plants. It is related to fats and oil content and In the aerobic tank, the LVSS ratio was also low and operational aspects such as sludge retention time (sludge it resembled that the microorganisms were not truly active, ages), low F ratio as well as dissolved oxygen. Bulking and also the cell retention time was high. The stability of LVSS occurred seasonally and periodically, which bring serious ratio is shown in Figure 4. The ratio of active sludge in operating problems and take a relating long time to restore total sludge ( ) had variation in the range of 0.2-0.7. [10, 11]. In Amol s treatment plant, the degreasing unit LVSS 709

Fig. 6: The SVI values for the duration of COD Removal (%) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 Anaerobic COD Removal Aerobic COD Removal 0.10 0.00 0 5 10 15 20 25 30 35 Time (Days) Fig. 8: onitored COD removal for duration of 1 month Fig. 7: onitored TSS removal for the duration of did not work well so oil and fats were conducted to the other units such as sedimentation tanks undesirably. At the most of the time, aerobic inlet TSS value was higher than its value in the anaerobic inlet. Two of the most common reasons for this problem are: low ph values (less than 4) and high organic loading rates [12]. Because of the presence of hustle conditions, the microorganisms may die and detach from the surface of the media. Therefore, increasing in TSS value was also reported in the literatures [13, 14]. The percentages of TSS removal from Amol plant are presented in Figure 7. The average percentages of TSS removal for the anaerobic and aerobic processes were 25 and 75%, respectively. There was an attempt for the full duration of one month to operate the plant at optimum condition. The processes were improved by addition of 10 kg/day manure into the anaerobic tank, urea and phosphate into the aerobic tank. Dosage of urea and phosphate was 10 kg/day and continued for the entire period of 30 days. The reformation was achieved. The data for COD removal in the anaerobic and aerobic tanks for one month of the treatment are presented in Figure 8. An increase in DO SVI 250 200 150 100 50 0 0 5 10 15 20 25 30 35 Time (Days) Fig. 10: onitored SVI for duration of 1 month concentration in the effluent was a good indication of Fig. 11: The stability of the LVSS ratio for the duration improvement in efficiency of COD and BOD removal [3]. of 1 month 5 Fig. 9: DO concentration for duration of 1 month 710

DO levels always were kept constant (about 2 mg/l), the 3. Zeybek, Z., S. Yuce Cetinkaya, F. Alioglu and DO level is shown in Figure 9.. Alphaz, 2007. Determination of optimum After process optimization, SVI values became operating conditions for industrial dye more desirable. Values for SVI are presented in Figure 10. wastewater treatment using adaptive heuristic The activated part of the sludge the ratio of ( LVSS ) criticism ph control. Environmental anagement has increased by15%. The improvement of Journal, 85: 404-414. activated sludge ratio is shown in Figure 11. The 4. oosvi, S. and D. adamwar, 2007. An integrated average value of the active sludge to total sludge process for the treatment of CETP wastewater ratio is about 0.5. using coagulation, anaerobic and aerobic process. Bioresource Technology Journal, 98: 3384-3392. CONCLUSION 5. Falletti, L. and L. Conte, 2007. Upgrading of activated sludge wastewater treatment plants with The biological treatment processes in Amol's hybrid moving-bed biofilm reactors. Industrial & industrial wastewater treatment plant were certainly Engineering Chemistry Research, 46(21): 6656-6660. improved. It was concluded that, by induction of microbial 6. APHA- AWWA-WEF (American Public Health consortium of animal manure into anaerobic tank, there Association, American Water Works Association, was a 15% increase in removal efficiency. Also by Water Environment Federation), 2005. Standard addition of urea and phosphate in to aerobic tank, methods for the examination of water and wastewater. there was a 5% increase in total removal efficiency. st 21 Ed., Washington DC: APHA-AWWA-WEF. Effluent COD was decreased by 50%. Active sludge and 7. Gray, N.F., 2004. Biology of wastewater treatment. sludge volume indices were increased by 15 and 30%, nd Vol. 4, 2 Ed., Imperial College Press, London. respectively. 8. Arceivala, J.S., 1998. Wastewater treatment for pollution control, 2nd Ed., Tata cgraw-hill ACKNOWLEDGEENTS Publishing Company, Delhi. 9. etcalf and Eddy, 2003. Wastewater engineering, The authors wish to acknowledge the staff, operation th reuse and disposal, 4 Ed., cgraw-hill, New York. and process engineers in Amol Industrial Park Treatment 10. Xie, B., X.C. Dai and Y.T. Xu, 2007. Cause and Plant for their suitable cooperation. pre-alarm control of bulking and foaming by icrothrix parvicella -A case study in triple oxidation REFERENCES ditch at a waste water treatment plant. Journal of Hazardous aterial, 143: 184-191. 1. Colmenarejo,.F., A. Rubio, E. Sanchez, J. Vicente, 11. Richard,., S. Brown and F. Collins, 2003. Activated.G. Garcia and R. Borja, 2006. Evaluation of sludge microbiology problems and their control. In municipal wastewater treatment plants with th the proceedings of The 20 Annual USEPA National different technologies at Las Rozas, adrid operator Trainers Conference, Buffalo, New York. (Spain). Environmental anagement Journal, 12. Eckenfelder, W.W. Jr., 2000. Industrial Water 81: 399-404. rd Pollution Control, 3 Ed., cgraw-hill, New York. 2. Lee, D.S., C.O. Jeon and J.. Park, 2001. 13. Orhon, D., F.G. Babuna and O. Karahan, 2009. Biological nitrogen removal with enhanced Industrial wastewater treatment by activated phosphate uptake in a sequencing batch reactor sludge, International Water Association (IWA) using single sludge system. Water Research Journal, Publishing, London. 35: 3968-3976. 14. Corbitt, R.A., 1999. Standard handbook of nd environmental Engineering, 2 Ed., cgraw-hill, New York. 711