DECS 2.0 Danfoss Energy Control System

Similar documents
Sage Grant Management System Requirements

YZP : SAUTER Vision Center

User Installation Guide

Molecular Devices High Content Data Management Solution Database Schema

v1 System Requirements 7/11/07

Requirements. System Requirements. System Requirements, page 1 Port Requirements, page 4 Supported Codecs, page 5

Cisco IP Communicator (Softphone) Compatibility

Read Me UNISTREAM AUTOMATION IDE

Computer Requirements

One Quality. Many Possibilities. The HMI Portfolio of Bachmann.

PVTC Technical Requirements

SERVER AND WORKSTATION MINIMUM REQUIREMENT

DUKANE Intelligent Assembly Solutions

Guide to Installing BBL Crystal MIND on Windows 7

To ensure you have the appropriate equipment and settings please review the following: Software and Hardware Recommendations.

EC-Net AX Supervisor with 0 Niagara network connections - for. EC-Net AX Supervisor with 100 Niagara network connections. Includes

LN-Builder 3.4 Installation Instructions

DCPS STUDENT OPTION HOME USE PROGRAM SIGN UP INSTRUCTIONS

Preparing the Windows version of the software for use

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Brainlab Node TM Technical Specifications

Figure 1: RotemNet Main Screen

EZ-View Network Communications Guide

WinCon Programmable Automation. Controller

Quick Start Guide. GV-Redundant Server GV-Failover Server. 1 Introduction. Packing List

System Requirements for Microsoft Dynamics GP 9.0

How To Use Safety System Software (S3)

System requirements for MuseumPlus and emuseumplus

Hardware & Software Specification i2itracks/popiq

Network Camera. Quick Operation Guide V4.0.1

Parallels Desktop 4 for Windows and Linux Read Me

Minimum Software and Hardware Requirements

WISE-4000 Series. WISE IoT Wireless I/O Modules

Facility Touch Client. SAUTER EY-TC505F110 Facility Touch Client software Commissioning. Manual D /26 D D

How To Build A Scada System

Microsoft Windows Apple Mac OS X

INSTALLATION MINIMUM REQUIREMENTS. Visit us on the Web

Schneider OS-Loader usage via Ethernet or USB.

System requirements for A+

BabyWare Imperial PC Software

Dualog Connection Suite Hardware and Software Requirements

Section 1.0 Getting Started with the Vālant EMR. Contents

Select Correct USB Driver

How To Use Exchange Reporter Plus On A Microsoft Mailbox On A Windows (Windows) On A Server Or Ipa (Windows 7) On An Ubuntu 7.6 (Windows 8) On Your Pc Or

SYSTEM SETUP FOR SPE PLATFORMS

Small Business Server Part 1

HARDWARE AND SOFTWARE REQUIREMENTS

SOFTWARE INSTALLATION INSTRUCTIONS

Prerequisites Guide. Version 4.0, Rev. 1

Adonis Technical Requirements

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Installing an Omnicast System Omnicast version 3.5

SNOW LICENSE MANAGER (7.X)... 3

CQG/LAN Technical Specifications. January 3, 2011 Version

pco.interface GigE & USB Installation Guide

MEDIA CONTROL SERVER 2.0

Receptionist-Small Business Administrator guide

SecureLinx Spider Duo Quick Start Guide

Delphi+ System Requirements

System Requirements. SuccessMaker 5

AXIS 262+ Network Video Recorder

System Requirements. 60GB free after OS and Updates, Raid 5 or Hybrid SSD array

System Environment Specifications Network, PC, Peripheral & Server Requirements

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

Patriot Hardware and Systems Software Requirements

AP ENPS ANYWHERE. Hardware and software requirements

Features. Full instrument configuration capability available via a Pocket PC. Communication with a Pocket PC using Infrared or RS485 Modbus

Priority Zoom v17: Hardware and Supporting Systems

Priority Pro v17: Hardware and Supporting Systems

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

MICROSOFT ENROLLMENT FOR EDUCATION SOLUTIONS (EES) AGREEMENT

Microsoft Windows Apple Mac OS X

Audit4 Installation Requirements

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

AXIS Camera Station Quick Installation Guide

inforouter V8.0 Server & Client Requirements

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

MYOB EXO System Requirement Guidelines. 30 April 2014 Version 2.7

Remote Deposit Capture Installation Guide

TOOLBOX. Quick Start Guide. Diagnostic Software. Introduction. TOOLBOX 12 Software Installation. TOOLBOX 12 System Requirements

s y s t e m r e q u i r e m e n t s

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Rugged and open to your applications

U90Ladder / VisiLogic /UniLogic and software utilities system requirements. Contents

Item Minimum Required Recommended Notes

Desktop Surveillance Help

Installation Guide v1.11 and Higher

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Install Guide Housatonic Project Plan for Web. Housatonic Software - Project Plan 365 App

Server Installation Procedure - Load Balanced Environment

ASTi PC ver Windows 7 Installation Guide. Document: DOC-01-PCVW7-IG-1

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

TrueAlarm Fire Alarm Systems

Network Communication rights... 2 Number of workstations Windows components... 3 Server... 3

User Manual Version p BETA III December 23rd, 2015

Access control designed simply for you

Computer Hardware and Software:

Transcription:

Data sheet DECS 2.0 Danfoss Energy Control System Description DECS 2.0 DECS 2.0: The Danfoss Energy Control System (DECS) is a web-based SCADA software solution (Supervisory Control And Data Acquisition) for district heating systems. This SCADA solution is typically installed locally at the heating utility and will automatically configure its user interface and functionality to support the application in the controller (for example Danfoss ECL Comfort 310). The user of the DECS 2.0 system is able to remote control and monitor the parameters settings in the controllers and also monitor actual, reference and historical values of sensors and meters connected to the controller. Danfoss ECL Comfort 310, OPR0010 and OPR0020 controllers are supported by the auto-configuration features of DECS 2.0, but the ECL Apex 20 controller can also be supported by manually adding graphics and programs into DECS 2.0. DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 1

User benefits The advantages of DECS 2.0 are among others: Easy installation Automatic configuration makes installation easy Advanced techniques are used for simplifying and automating the installation process. Once the controller is installed and connected to the network, the web-based user interface is generated on the DECS server with just a few mouse clicks. The DECS server software is installed at the heating plant and has no special requirements except for a reliable PC connected to the internet. Easy customization User interface and functionality suits project specific needs DECS is a visualisation platform based on the Atvise SCADA system. The user interface and functionality is easily customized by the system integrator to project specific requirements using the Engineering Tool. The scaleability of DECS ensures an optimized SCADA solution for small, large and growing district energy networks. Easy access Access to control and monitor locally and remotely Data is constantly exchanged between the controllers and the DECS Server. The server provides an intuitive user interface, which is accessible from any standard browser on a PC, laptop or smartphone connected to the internet. You can control and monitor your heating station and substation installations from everywhere. Standard System is built on standardized software and interfaces Standardized DECS Server software increases reliability, lowers hardware complexity and allows integration of other building automation systems into the heating system. The communication interfaces are based on the well-known Modbus- RTU or Modbus-TCP protocols, which provide a reliable, low complexity network. System architecture The architecture of DECS 2.0 is shown below. The central building blocks of the DECS 2.0 system are the HMI (Human Machine Interface) using the Atvise SCADA Client software from Certec, the database for storing all logged data from the controllers and the OPC UA Server software handling the data communication with the controllers. DECS 2.0 supports data communication between the server and controllers using Modbus-TCP (Ethernet), LON bus and Modbus-RS485. CENTRAL SYSTEM HMI (atvise) (Web-Browser / SCADA-System) Database OPC UA Server Ethernet (MODBUS-TCP) LON netw ork MODBUS (RS485) Bioma ss Bioma ss Biomass Bioma ss Biomass Biomass Bioma ss Biomass Bioma ss 2 VD.HX.A3.02 Danfoss 07/2013 DEN-SMT/DK

Application DECS 2.0 software automatically adapts its user interface to fit the application in the controller. The following controller applications are supported: ECL Comfort 310 controller * Please see List of application keys supported by DECS 2.0 Go to http://den.danfoss.com. In the Products menu select SCADA Solutions > Documentation > SCADA Solutions > Data sheet. OPR0020 * Firmware R4 and newer OPR0010 * Firmware v3.6 As an option the ECL Apex 20 controller can be integrated into DECS 2.0 to remote control and monitor the district heating utility or boiler house. This requires a system integrator to develop a customized application for the ECL Apex 20 controller as well as a customized HMI for the DECS 2.0 system using the OPC server software for ECL Apex 20. Below is an application example of DECS 2.0 in a biomass district heating network using Modbus-RS485 for data communication. The server, which has DECS 2.0 installed, is located in the district heating utility and a central laptop is used for operating the DECS 2.0 system. An external service provider also has access to the DECS 2.0 system using his laptop connected to the internet. The server and the ECL Comfort 310 controllers are communicating via an RS485 serial link using the Modbus protocol. j k l n p j m o j q j Private house k Boiler house for biomass l Modbus-RS485 network m Internet n DECS 2.0 server o DECS 2.0 client (external service provider) p DESC 2.0 client (central administration) q ECL Comfort 310 controller DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 3

Application Below is an application example of DECS 2.0 in biomass district heating network using Modbus-TCP (ethernet) for data communication. It is similar to the previous example except that the ECL Comfort 310 controllers are communicating with the server via standard internet connections using the Modbus protocol. These internet connections may be used also by laptops in the houses for browsing the internet and also to access the DECS 2.0 system. j k l n p j l m o j q l j Private house k Boiler house for biomass l Modbus-TPC network (internet) m Internet n DECS 2.0 server o DECS 2.0 client (external service provider) p DESC 2.0 client (central administration) q ECL Comfort 310 controller Languages The following languages are supported by the graphical user interface of DECS 2.0: English German Italian 4 VD.HX.A3.02 Danfoss 07/2013 DEN-SMT/DK

Data communication The options for data communication between controllers and server are listed below. See also the selection matrix in the next section for information on selecting the correct data communication type. Type Description Remarks Modbus-RS485 Modbus communication via RS485 serial link is supported by ECL Comfort 310 controllers. Additional network components may be needed, i.e. repeaters and gateways. Modbus-TCP Modbus communication via ethernet over internet is supported by OPR0020 and ECL Comfort 310 controllers. Additional network components may be needed, i.e. router and firewall. LON bus LON bus communication via twisted pair serial link is supported by OPR0020 and ECL Comfort 310 controllers. The ECL Comfort 310 controller must be equipped with the ECA34 LON module. Licenses for components using LON bus are needed. LON networks should not be offered in new DECS 2.0 projects. Modbus is recommended instead. Selection matrix for existing and new DECS networks This matrix shows which controllers, data communication network and SCADA software are to be used in existing DH networks in case of warranty or expansion projects. For new DH networks the ECL Comfort 310 controller must be used with a Modbus or Ethernet data network with DECS 2.0. Existing DH networks New DH networks Project type Warranty Expansion (in substation) OPR0010 OPR0020 ECL Comfort 310 (incl. LON module) ECL Comfort 310 ECL Apex 20 ECL Apex 20 (in DH utility) Data network LON (or Ethernet) Modbus-RS485 or Modbus-TCP Software DECS 1.0 (E3) DECS 2.0 DECS 2.0 OPC Server (ECL Apex 20) DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 5

Ordering To use the DECS 2.0 system a server must have the Atvise SCADA client software and DECS 2.0 software installed. A combined license for Atvise SCADA Client software and DECS 2.0 software is ordered using the code no. for DECS 2.0 Software license. Additionally a DECS 2.0 license must be ordered for each controller registered to the DECS 2.0 system. Miscellaneous data communication components and software drivers may also be needed to establish a DECS 2.0 system. The components needed depend on the size of the data communication network and type of network, i.e. Modbus or LON. If a LON network is used the ECL Comfort 310 controller must be equipped with an ECA34 LON module and the DECS 2.0 server must be equipped with the Loytec LON NIC. In order to use ECL Comfort 310 controllers in a DECS 2.0 system, each ECL Comfort 310 controller must have a supported application key installed. If the DECS 2.0 system is customized to include also remote control and monitoring of the district heating utility an ECL Apex 20 controller and ECL Apex 20 OPC Server software are needed. Type Designation Code no. Software DECS 2.0 Software license DECS 2.0 license 187B1500 187B1501 Data communication ECA34 LON module for ECL Comfort 310 1) Loytec LON NIC (PCI/Parallel/USB) 087H3204 004F9067 Application Please see List of application keys supported by DECS 2.0 Go to http://den.danfoss.com. In the Products menu select SCADA Solutions > Documentation > SCADA Solutions > Data sheet. 3) ECL Comfort 310 2) OPR0020 2) ECL Apex 20 087H3040 004F9021 087B2506 Other accessory hardware and software for DECS 2.0 projects are to be purchased locally or outsourced to local partners/suppliers. 1) No separate data sheet exists for this product. To be used only when expanding existing OPR0020/LON bus based DH networks with ECL310 controllers 2) See separate data sheet for this component for ordering details 3) Max. 1200 controller 6 VD.HX.A3.02 Danfoss 07/2013 DEN-SMT/DK

Technical data Modbus-RS485 data communication: Data format 1 start bit 8 data bits even parity 1 stop bit Communication protocol Modbus RTU Electrical interface RS485 Cable type Twisted pair + Modbus reference (signal ground) Max. bus cable length 1200 m (dependent on cable type and installation) Communication speed 38.4 Kbit/s half duplex (default) 19.2 Kbit/s half duplex 9.6 Kbit/s half duplex Network According to the standard Modbus Serial Line Implementation Guide V1.0 Max. number of Modbus masters 30 Max. number of controllers per Modbus master 247 Modbus-TCP data communication: Communication protocol Modbus TCP Electrical interface Ethernet, RJ45 connector Cable type Standard Ethernet cable (CAT 5) Max. bus cable length According to Ethernet standard Communication speed 10 Mbit/s 100 Mbit/s TCP Port number 502 (default for Modbus TCP protocol) Network Star network according to the standard Ethernet implementation guidelines LON data communication: Communication protocol LonWorks Electrical interface RS485 Cable type Twisted pair with shield Max. bus cable length 500 m (dependent on cable type, termination and installation) Communication speed 78.1 Kbit/s Network Serial line, star or loop network according to the LonWorks implementation guidelines by Echelon Max. number of controllers per NIC-interface 500 DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 7

DECS 2.0 system requirements DECS 2.0 server: Operating system Microsoft Windows XP (SP3 with latest updates installed) (32-bit) Microsoft Windows 7 (SP1 with latest updates installed) (32-bit) CPU Intel or AMD processor (>= 1,6 GHz) RAM Minimum: 4 GB RAM Free disc space 500 GB (depending on the number of controllers connected to DECS 2.0 and archieving frequency) Video A windows certified graphics card and driver. Minimum resolution is 1280*1024 pixel 3 rd party software Atvise server V2.1.18 (Certec) Loytec network interface software 4.1.x for LON networks Microsoft.NET Framework 3.5 and compatible versions Web browser SVG capable internet browser: Mozilla Firefox Internet Explorer Google Chrome Web browser must comply with requirements of Atvise SCADA Client software. For details about specific browser versions compatible with Atvise please visit http://www. atvise.com/en/vendors/compatibilitylist Backup recommendations RAID Level 1 or RAID Level 5 Data communication interface on DECS 2.0 server: Modbus-RS485 Modbus-TCP LON bus RS485 port compatible with MOXA UPort 1130 MOXA NPort 5150 Phoenix Contact FL COM SERVER RS485 Ethernet compatible interface Loytec LON NIC (LonWorks/EIA 709) using PCI, Parallel or USB for LON networks DECS 2.0 client: Operating system Microsoft Windows XP (SP3 with latest updates installed) Microsoft Windows 7 (SP1 with latest updates installed) CPU Intel or AMD processor (>= 1,6 GHz) RAM Minimum: 2 GB RAM Free disk space 1 GB Video A windows certified graphics card and driver. Minimum resolution is 1280*1024 pixel Web browser SVG capable internet browser: Mozilla Firefox Internet Explorer Google Chrome Web browser must comply with requirements of Atvise SCADA Client software. For details about specific browser versions compatible with Atvise please visit http://www. atvise.com/en/vendors/compatibilitylist 8 VD.HX.A3.02 Danfoss 07/2013 DEN-SMT/DK

Technical literature and additional information Type Description Literature no. Installation guide, DECS 2.0 Installation guide for DECS 2.0 software on VI.HX.C servers incl. Atvise SCADA client, HMI and database including instructions on how to configure DECS 2.0 User guide, DECS 2.0 User guide on how to use the features of DECS 2.0 at district heating networks VI.HX.A Quick guide, DECS 2.0 User guide on how to use the features of DECS 2.0 in homes VI.HX.B For further information on supported application keys please visit http://den.danfoss.com. In the Products menu select SCADA Solutions > Documentation > SCADA Solutions > Instruction. DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 9

10 VD.HX.A3.02 Danfoss 07/2013 DEN-SMT/DK

DEN-SMT/DK VD.HX.A3.02 Danfoss 07/2013 11

12 VD.HX.A3.02 Produced by Danfoss A/S 07/2013