Summary of Significant Changes at this Revision. Items Required

Similar documents
STANDARD OPERATING PROCEDURE FOR NOVA STAT STRIP CONNECTIVITY BLOOD GLUCOSE METERS FOR USE IN LEEDS NHS TRUST

PD-UserHbk-01. Pages printed from this document are uncontrolled - For latest versions please refer to electronic laboratory handbook

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Blood Glucose & Ketone Monitoring System. User s Manual

Title: Fingerstick Glucose by Accu-Chek Inform

Caution! Please read complete Owner s Booklet and all product Instructions for Use.

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

FLASH GLUCOSE MONITORING SYSTEM. User s Manual

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

PROCEDURE FOR BLOOD GLUCOSE MONITORING

Preface. Preface. A Healthcare professional should be contacted when Customer Service is not available.

Blood Glucose Monitoring System USER GUIDE

Blood Glucose Monitoring System USER GUIDE. Replaces Owner s Booklet

SD CodeFree BLOOD GLUCOSE MONITORING SYSTEM

Key Features in the AgaMatrix Jazz

Blood Glucose Monitoring. Eileen Whitehead 2010 East Lancashire HC NHS Trust

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

Nova Max Blood Glucose Monitor Owner s Guide

The OmniPod Insulin Management System

QUALITY ASSURANCE AND QUALITY CONTROL REFERENCE GUIDE FOR MULTI-PATIENT USE FACILITIES

QUALITY ASSURANCE AND QUALITY CONTROL REFERENCE GUIDE FOR MULTI-PATIENT USE FACILITIES

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Biochemistry Validation Form

Guideline for the Administration of Insulin by Nursing Staff

Suggested BiliChek Usage Protocol

The FreeStyle Lite Meter and How It Works

Medications or therapeutic solutions may be injected directly into the bloodstream

ClikSTAR - Important facts about your new insulin delivery device.

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE

Blood Glucose Monitoring System Owner s Booklet Instructions for use

THE DISPOSAL OF HEALTHCARE WASTE BY NHS GRAMPIAN FROM ACUTE HOSPITAL WARDS

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

Blood Glucose - How to test

In-Service Plan for Blood Glucose Testing.

Textbook: Chapter 12 pages , Chapter 13 pages

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material)

Self-Monitoring of Blood Glucose

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

Accutrend Plus. User s Manual

CoaguChek System. XS Plus. User Manual

Blood Sugar Monitoring

CDDFT - Health Call INR Monitoring Service. Health Call INR Monitoring Service. Patient Training

PROCEDURE FOR CATHETER AFTERCARE

Wireless Blood Glucose Monitoring System

ph Measurements of Common Substances

Buyers guide. Blood glucose systems CEP 08008

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Hemoglobin Testing using the Data Management HemoCue Analyzer

School Year 20 / 20. Diabetes Health Care Plan for Southgate Schools

Safe Work Procedure Sharps and Bio-hazardous waste handling and disposal

Section 10. Guidelines for the Safe Handling and Disposal of Needles and Sharps

Standard Operating Procedure

URINE DIPSTICK Multistix 10SG

THE SAFE DISPOSAL OF CLINICAL/DOMESTIC WASTE

Introduction A JP Drain is a soft tube and container used to drain fluids that build up under the skin after surgery.

CoaguChek System. User Manual. This is a CLIA waived system.

MANITOBA PATIENT SERVICE CENTRE STANDARDS

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

INFM22AGB. IMM Rev CUSTOMER CARE LINE:

Instructions for Use. Components of the GENOTROPIN PEN 12

User Manual. Read this user manual carefully before you start testing

Guidelines for the Management of Spillage of Cytotoxic Drugs. No changes have been made as evidence base remains current.

INSTRUCTIONS FOR USE. Read this information before you start. Important things to know about your SmartJect autoinjector. Important things to remember

ADMINISTRATIVE MANUAL Policy and Procedure

Hazardous Drugs Spill Kit

Laboratory Biosafty In Molecular Biology and its levels

Administration of Medications & Fluids via a Peripheral Intravenous Cannula

X-Plain Foley Catheter Male Reference Summary

How To Use An Easypad On A Pc Or Macbook Or Ipad (For Pc)

BLOOD GLUCOSE METER / GLYCOMÈTRE. User s Manual Manuel de l'utilisateur

General. What is a laboratory test? What is a waived test?

Inform II Glucose Meter

BLOOD GLUCOSE METER. Standard Owner s Booklet for Single Patient Use Only

INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section:

blood glucose monitoring

Insulin pump: advice for schools

Introduction BIOMEDICAL WASTE

2.3. The management in each HCF shall be responsible for ensuring good waste management practices in their premises.

Health Protection Agency INFECTION PREVENTION AND CONTROL GUIDELINES FOR BLOOD GLUCOSE MONITORING IN CARE HOMES

BLOOD GLUCOSE METER. Getting Started Guide for Single Patient Use Only

Cytotoxic and Biotherapies Credentialing Programme Module 6

Accu-Chek Inform II system. Professional glucose testing for the wireless age

STANDARD OPERATING PROCEDURE

Diabetes Insulin Pump Health Care Plan District Nurse Phone: District Nurse Fax:

CYTOTOXIC PRECAUTIONS A GUIDE FOR PATIENTS & FAMILIES

Medical or Biological Waste: Storage, Treatment, Disposal and Transportation Plan

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

BIO MEDICAL WASTE MANAGEMENT

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

Black Hills Healthcare System

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Blood Glucose Meter recommendations for GP practices

HED\ED:NS-BL 037-3rd

PATIENT URINARY CATHETER PASSPORT

Ketones and Ketoacidosis

Transcription:

Summary of Significant Changes at this Revision Update RUH logo Purpose and Scope Items Required 1. The Abbott FreeStyle Optium H meter is a battery-powered device designed for the measurement of blood glucose in a Point of Care setting. 2. The meter uses single-use test strips to measure the concentration of glucose. 1. Abbott FreeStyle Optium H Meter(community) 2. Abbott FreeStyle Optium H Blood Glucose Test Strips (Community) 3. MediSense Glucose & Ketone Control Solutions 4. WEQAS External glucose EQA sample 5. Lancing Devices 6. Abbott Quality Control record book Definitions and Abbreviations Grade / Qualifications Required POCT = Point of Care Testing NPT = Near Patient Testing IQC = Internal Quality Control QC=Quality Control EQA = External Quality Assurance NMC = Nursing and Midwifery Council MHRA = Medicines and Healthcare products Regulatory Agency. Nursing Staff: All Trained operators Health Care Assistants: All trained operators Biomedical Scientists Supervised Trainee BMS Staff Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 1 of 8

Contents 1. Abbott FreeStyle Optium H Glucose meter Page 3 2. Principle Page 3 3. Calibration Page 3 4. Internal Quality Control (IQC) Page 4 5. Patient Preparation Page 5 6. Patient Testing Page 5 7. External Quality Control Page 5 8. Limitations of the FreeStyle Optium H Meter Page 6 9. Limitations of Procedure Page 6 10. Maintenance Page 7 11. Supplies Page 7 12. COSHH and Health and Safety Page 8 13. Adverse Incidents Page 8 14. Operators Page 8 15. References Page 8 Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 2 of 8

1. Abbott FreeStyle Optium H Glucose meter FreeStyle Optium H meter This meter is for use within the RUH Hospital and Community Hospitals, and should only be used with FreeStyle Optium H test strips (see pictures below). The FreeStyle Optium H meter requires calibration (see section 3 Calibration page 4). FreeStyle Optium H meter FreeStyle Optium H Glucose test strips 2. Principle Glucose measurement: Bioamperometry Glucose in the blood reacts with the enzyme NAD-glucose dehydrogenase on the test strip. The chemical reaction releases NADH, which then reduces Phenanthroline quinine. A voltage is applied across the test strip. The current generated from the sample is proportional to the concentration of glucose in the sample and is expressed in mmol/l. 3. Calibration The Freestyle Optium H meter must be used with FreeStyle Optium H strips only. The meter requires calibrating for every new box of test strips using the calibrator strip supplied in box. Failure to calibrate properly will cause incorrect results. 1) With the lot number facing upward, insert the contact bars of the calibrator into the monitor. The monitor will turn on automatically. 2) The lot number of the calibrator strip and test strip foil package will appear in the display window Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 3 of 8

3) Check that the lot number matches on all the items; Meter display window, test strip calibrator, test strip instructions for use, test strip foil packet. If the Lot # on all these items matches, calibration is complete 4) Use only the calibrator supplied with the test strips. Keep the calibrator until all the test strips in the box have been used then discard the calibration strip. 4. Internal Quality Control (IQC) Lo and Hi controls must be assayed. IQC ranges are located on the package insert of Test strips. Retain package insert until box of test strips has been used. IQC must be performed on each individual Freestyle Optium H glucose meter daily, weekly or as required depending on usage. Quality control must be performed prior to testing a patient sample. Frequency will depend on protocol for ward/department. 1) Quality control solutions have a shelf life of 3 months once opened. Write date opened and expiry date on bottles. 2) Remove a test strip from its foil package 3) Insert the three black lines at the end of the test strip into the strip port. 4) Push the test strip in until it stops the meter turns on automatically 5) Check date and time displayed are ok change if required 6) Check lot number for box of test strips 7) To mark the test as a control test, Press and Release the middle button once. A QC bottle will be displayed. 8) Apply control solution to the test strip and the meter begins the test. 9) The display will show the countdown. 10) When the test is complete the control result will be displayed in the display window. Record the result in the QC record book. 11) Remove the test strip from the sample port and discard appropriately. 12) Repeat steps 2-12 for Hi control 13) If QC is acceptable proceed with patient testing. 14) If QC is outside manufacturers limits repeat. If the QC is still out contact the Abbott helpline on 08000321016. Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 4 of 8

5. Patient Preparation The site of sampling should be chosen to cause minimum discomfort and skin damage. The site of the puncture must be cleaned with warm soapy water, rinsed and dried. Do not use alcohol wipes or hand wipes to cleanse the skin. 6. Patient Testing All Point of Care Testing devices have limitations. Please be aware of the limitations prior to use. 1) Remove a test strip from its foil package 2) Insert the three black lines at the end of the test strip into the strip port. 3) Push the test strip in until it stops the meter turns on automatically 4) Check date and time displayed are ok change if required 5) Check lot number for box of test strips 6) When the words apply blood appear on the meter display obtain a drop of blood from the patient 7) Touch a drop of blood to the white area at the edge of the test strip. The blood will be drawn into the test strip. 8) Continue to touch the blood drop to the white area until the meter begins the test. It will beep. 9) At the end of the countdown the meter will beep again and the result will be displayed in the display screen. 10) Record the glucose result in the patients case notes. NB: Also include in the case notes the date/time test performed, the device used including location, the test strip number, and the identity of the person performing the test and the person transcribing the results if different. 11) Remove the test strip from the sample port and dispose of appropriately. 12) If the code LO or HI is displayed on the meter then medical attention must be sought. A blood sample must be collected into a fluoride oxalate tube and sent to the laboratory for glucose analysis. Refer to the User Guide for graphical instructions. 13) If unable to obtain an adequate blood sample repeat the test and record in the patient notes. 7. External Quality Control External Quality Control differs from IQC in that the accuracy of the procedure is not known until after the results have been issued. The user does not know the glucose concentration at the time of analysis and the results are assessed independently. An External Quality control sample is distributed to all authorised Freestyle Optium H meter users every three months by biochemistry with a result sheet. The sample must be analysed (as per Patient Testing) on every Freestyle Optium H meter located on the ward or in the department. Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 5 of 8

Record the serial number of each individual meter that is used and record the glucose result for the EQA sample. Return the result sheet to the biochemistry department. 8. Limitations of the Freestyle Optium H Meter All point of care testing devices have limitations and these should be remembered at all times. The blood glucose meter alone cannot make a diagnosis of diabetes or hypoglycaemia and a confirmatory sample must be sent to the laboratory. All results must be interpreted with respect to the patient s condition. If an unexpected high or low glucose result is obtained, a repeat test must be performed and a venous sample sent to the biochemistry laboratory. If a glucose result is less than 2.5 mmol/l or greater than 20.0 mmol/l a venous sample must be sent to the biochemistry laboratory for confirmation. Blood Glucose Action Limits by non qualified staff Blood Glucose results less than 4 mmol/l Blood Glucose results greater than 10 mmol/l Must be reported to a trained member of the nursing or medical staff The glucose test strip has been evaluated with neonatal blood. As a matter of good clinical practice, caution is advised in the interpretation of neonate glucose values below 2.8 mmol/l. Do not use the memory function on the Freestyle Optium H meter to retrieve patient results. 9. Limitations of Procedure 1) The system is not designed for use with serum or plasma sample. 2) FreeStyle Optium H test strips are designed for use with fresh whole blood 3) Venous and arterial whole blood samples collected into lithium heparin and EDTA may be used if analysed within 30 minutes. 4) Do not use blood collected into fluoride or oxalate 5) Blood glucose results are displayed as mmol/l. Do not use mg/dl. 6) Use meter between 15 o C and 40 o C 7) Store strips between 4 o C and 30 o C 8) Haematocrit range is 20%-70% Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 6 of 8

9) Test results may be erroneously low if the patient is severely dehydrated, severely hypotensive, in shock or in a hyperglycaemic-hyperosmolar state (with or without ketosis) 10) Do not use during intravenous infusion of high dose ascorbic acid or during xylose absorption testing. 10. Maintenance Store the meter in the workstation provided. Clean the surface of the meter with a damp cloth and mild soap It is acceptable to clean surface with 10% bleach, 70% Alcohol, or 10% Ammonia. Do not clean the strip port Do not pour liquid into the strip port or buttons Do not place the meter in water Batteries: The meter will display a small battery icon when it is necessary to change the battery. Replacement batteries are available from biochemistry Ext. 4712. Battery changes must be documented in the Quality Control Record book. 11. Supplies Test Strips RUH and Community Hospitals order from RUH pharmacy (01225 82640) Quality Control (QC) RUH and Community Hospitals should contact biochemistry Dept. at RUH (01225 824712). Batteries and QC Log Books RUH, Community Hospitals order from Biochemistry Dept. at RUH (01225824712). Faulty FreeStyle Optium H Glucose Meter Contact Abbott Diabetes Care HCP helpline 08000321016 Extra FreeStyle Optium H Glucose Meters RUH and Community Hospitals contact RUH Biochemistry (01225 824712) External Quality Assurance Samples Biochemistry provides External Quality Assurance samples (EQA) and performance report feedback every three months to all FreeStyle Optium H meter users. For support when performance is poor, contact Abbott Diabetes Care HCP helpline 08000321016. Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 7 of 8

12. COSHH and Health and Safety Freestyle Optium H Test Strips: No Hazard Medisense Lo and Hi Control solution: No Hazard External Quality Assurance (EQA) sample: Treat as Biohazard Gloves must be worn at all times when processing controls, EQA and patient samples. Dispose all test strips, finger pricking device, control solutions and EQA in a sharps bin or yellow bag for incineration as appropriately required. 13. Adverse Incidents Any adverse incidents regarding the use of the Freestyle Optium H blood glucose meter must be reported via the ward manager/practice manager to the Point-of-Care testing committee for evaluation and reporting on to the MHRA. 14. Operators Only staff that are trained in accordance with the Freestyle Optium H blood glucose meter Training Programme provided by Abbott can use the meter. Refer to the NMC Professional Conduct Code 2008. 15. References 1. Abbott Freestyle Optium H Blood Glucose Monitoring System User s Guide 2. Abbott package insert for Freestyle Optium H Blood Glucose Testing Strips and Quality Control Solutions 3. NMC Professional Conduct Code 2008 4. RUH Medical Equipment Policy Copy number Location held 1 Manual Lab-Glucose Meters SOP Folder 2 Electronic Copy POCT section of Intranet Author: M Stubberfield Checked by: H Witham Approved by: H Witham Page 8 of 8