Exhaust air device for clean rooms SPWH, SPWV

Similar documents
How To Make A Supply Air Ceiling

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Supply air diffuser ROKA/RPKA

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

HEPA Terminal Filter Units Types F640, F650, F660

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

Under sill units. Type FSL-B-ZAS

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Part H DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

Acoustic Design Guide. NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

Direct and Reflected: Understanding the Truth with Y-S 3

TFSR & TFSK Roof Fans

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

Technical catalogue convectors POLAND 2012

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Air-water systems for efficient air conditioning

Affordable Sports Halls

Exhaust noise control case study for 2800 class locomotive

An update on acoustics designs for HVAC (Engineering)

squrboxbox heat recovery squrboxbox I technical information

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

E D I T I O N

Acoustic design according to room type

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Grilles & Diffusers Series LFP Incorporating

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

plenum slot diffusers

Acoustic design with wall acoustic solutions

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Testing laboratory HVAC. Test report No.: HP e

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

CADB and CADT-D / DI / DC Series

Rittal TopTherm fan-and-filter unit

Installation, operation and maintenance manual TX 35A

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Relationship between Sound Pressure and Sound Power Levels

Product Information. Tel: x2426 or x2443 Fax:

PART VIII: ABSORPTIVE SILENCER DESIGN

Basics of HVAC Cleaning

Air Comfort. Technical Catalogue > Roof Fan STOF

Owners Manual. Three-Way Architectural Speaker. www. artcoustic.com

Displacement ventilation

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Clinic Washer-Disinfectors. Washer-Disinfector Line

Flexit air handling unit K2 R

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x x x x600 M206, M208, M238

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x x x600

Sound Power Measurement

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Saint-Gobain Ecophon Limited RIBA Accredited CPD Seminar

HVAC Acoustic Fundamentals

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

HDA

sound reduction systems for commercial, educational and industrial environments

Noise in the Classroom

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

DQGDQDXGLWRULXP

Marine Generating Sets 3.7 to 50 kva

IH E Sigma Island 90

Experiment (13): Flow channel

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite

Video conference solutions

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Telepresence T3 Room recommendations

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR

Figure 1 : Typical Computer Simulation of a Bass Reflex Speaker

Basic Selection & Proper Application of Overhead Air Distribution Devices

Exhaust Calculation Booklet

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

How To Buy A Designo Grille

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

CBA Volume: Student Sheet 1

The Role of Acoustics in Curtain Wall Design:

CELO5. User & Installation Manual.

TURBOWENT TULIPAN - rotary chimney cowl Ø150

High-speed spiral doors for deep-freeze applications. TK Series

AMD-33 Air Measuring Station with VCD-33 Control Damper

How To Get A Passive House

A novel approach of multichannel and stereo control room acoustic treatment, second edition

THE ACOUSTICS OF THE "NUOVO TEATRO COMUNALE" IN CAGLIARI

Cleanroom Solutions Ltd T: F: E: W:

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Characterization of acoustics in open offices - four case studies

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

Transcription:

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 159 Exhaust air device for clean rooms SPWH, SPWV Exhaust air devices SPWH and SPWV for clean rooms are intended for ceiling or wall installation in premises where the requirements for very clean air are high, for example clean rooms, pharmaceutical industries, etc. SPWH has duct connection placed at the side of the terminal box and SPWV has duct connection positioned on the top. The device includes a HEPA filter of class H1 or according to PN-EN1822-1, which ensures a very high degree of filtration. Integral measurement sockets in the device mean that the pressure drop can be measured and that any filter leakage can be identified. Excessively high pressure drops across the filter also indicate that it should be replaced. SPW(H,V) is made of painted steel sheet, and its construction makes filter replacement quick and easy. On request diffuser can be also equipped with filter class H11. Product facts Quick selection Product code example: Size (m/h) Max airflow for Max airflow for Airflow l/s at sound level SPW(H,V) with filter H1 SPW(H,V) with filter l/s m/h l/s m/h 0dB(A) 5dB(A) SPW(H,V) 0 SPW(H,V) 45 78 175 SPW(H,V) 5 SPW(H,V) 61 242 08 280 60 870 1110 46 10 165 70 69 (249) 129 (46) 157 (566) 142 181 510 6 15 (5) 189 (682) 25 (847) 182 (655) 229 (826) 289 (1041) Exhaust air device SPW(H,V) Intended for ceiling or wall installation. Has an integrated connection box. Equipped as standard with a HEPA filter of class H1 or. Four sizes with a broad air flow range. Available either with circular or rectangular connections. Exhaust air diffuser with filter SPWH-61-2-14-1 Device of size 61 with rectangular connection with a HEPA filter of class size 610x610x69mm. Duct connection on the side. In order to keep the work of diffuser normal, it is recommended to not exceed the maximum airflow values given in above table. The diffuser is painted in colour RAL 9010. Fläkt Woods PLBOV 2010.07 1

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 160 Air flow, pressure drop, sound levels SPWH, SPWV 0 00 2 1 H1 75 125 1 175 225 2 275 21 SPWH, SPWV 45 00 25 0 5 40 45 55 60 65 70 75 78 2 0dB(A) 1 H1 1 2 00 400 4 0 5 600 42 60 70 80 90 110 120 10 140 1 160 170 60 Pressure drop for a complete SPNH, SPNV terminal with an original filter of class H1 and and height of H = 69mm. In the above graphs the sound levels in db(a) are indicated for a reference room with 10 m 2 room absorption, equivalent to 4 db room attenuation. L W = L A10 + K ok Fläkt Woods PLBOV 2010.07 2

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 161 Air flow, pressure drop, sound levels SPWH, SPWV 5 00 2 1 H1 5dB(A) 0dB(A) 00 400 0 600 700 800 870 SPWH, SPWV 61 00 60 80 120 140 160 180 220 240 2 5dB(A) 1 H1 0dB(A) 400 0 600 700 800 900 0 1 111 120 140 160 180 220 240 260 280 00 Pressure drop for a complete SPNH, SPNV terminal with an original filter of class H1 and and height of H = 69mm. In the above graphs the sound levels in db(a) are indicated for a reference room with 10 m 2 room absorption, equivalent to 4 db room attenuation. L W = L A10 + K ok Fläkt Woods PLBOV 2010.07

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 162 Final pressure drop Final pressure drop for terminal with a HEPA filter of class H1 The final pressure drop for the terminal indicates when the filter requires replacement. Measurement is performed with the help of the measurement tube. 700 600 P [Pa] 0 400 00 size 0 45 5 61 00 400 0 600 700 800 900 0 1 V[m/h] 25 75 125 1 175 225 2 275 00 V[l/s] Final pressure drop for terminal with a HEPA filter of class The final pressure drop for the terminal indicates when the filter requires replacement. Measurement is performed with the help of the measurement tube. 600 P [Pa] 0 400 size 0 45 5 61 00 1 2 00 400 4 0 5 600 6 V[m/h] 21 0 40 60 70 80 90 110 120 10 140 1 160 170 180 V[l/s] Fläkt Woods PLBOV 2010.07 4

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 16 Acoustical data, definitions, dimensions The sound power levels for different octave bands are obtained by adding together the sound pressure level L A10, db(a), from the graphs, and the corrections K ok for the octave bands in the table with the help of the following formula: Terminal dimensions B A Dn 0 L W = L A10 + K ok E 1 95 Correction K OK C D Correction K ok in db for Size octave bands, mean frequency, Hz 6 125 2 0 0 0 4000 8000 0 14 11 7 2 - -8-15 -21 45 14 1 4 0-2 -7-14 -2 5 18 15 9 2-4 -10-1 -22 61 17 16 9 - -9-11 -19-24 E 2 G B F A 0 62 C D Definitions q air flow l/s, m /h p pressure drop Pa p max final pressure drop (indicates filter replacement) L A10 Pa sound pressure level with a room attenuation of 4 db (10 m 2 room absorption area) db(a) L W sound power level db K ok octave band correction db Size A B C D E 1 E 2 F G Dn 0 4 4 84 84 405 0 00 80 160 45 486 486 56 56 445 0 4 80 5 556 556 606 606 497 0 520 80 2 61 640 640 690 690 497 0 600 80 2 All dimensions are indicated in mm. Filter dimensions Size length x width (mm) H (mm) 0 05 x 05 69 45 457 x 457 69 5 55 x 55 69 61 610 x 610 69 Fläkt Woods PLBOV 2010.07 5

Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA - 2010 page 164 Descriptive text, product code Descriptive text Supply air terminal SPWH, SPWV for clean rooms for ceiling installation with a HEPA filter of class H1 or and with circular/rectangular duct connection manufactured by Fläkt Woods. Product code Supply air terminal (spigot at the side) SPWH-aa-b-cc-d Diffuser size (0, 45, 5, 61) Duct connection shape 1 = round 2 = rectangular Filter class 1 = H1 14 = Colour 1 = standard RAL 9010 X = any other colour from RAL palette Supply air terminal (spigot on the top) SPWV-aa-b-cc-d Diffuser size (0, 45, 5, 61) Duct connection shape 1 = round 2 = rectangular Filter class 1 = H1 14 = Colour 1 = standard RAL 9010 X = any other colour from RAL palette Fläkt Woods PLBOV 2010.07 6