GasGard 100 Control System

Similar documents
SMS GSM Alarm Messenger

Temperature & Humidity SMS Alert Controller

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

Natural Gas Well Automation using Kingfisher RTU Products

Ultima X Series Gas Monitors

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

SNMP Web Management. User s Manual For SNMP Web Card/Box

Square D Model 6 Motor Control Centers

securityprobe5es -X20

Web-Based Remote Monitoring & Datalogging

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

High Power Programmable DC Power Supplies PVS Series

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Multi-Range Programmable DC Power Supplies 9115 Series

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Automation Unit TM 1703 ACP Flexible automation and telecontrol

EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

Your remote sites at your fingertips?

NEW. EVEN MORE data acquisition and test stand automation

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Implementing a Reliable Furnace Monitoring System

Simplify Data Acquisition with a Built-in LXI Web Server

Product Information Fire alarm panel 8000 C

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

WISE-4000 Series. WISE IoT Wireless I/O Modules

Data Loggers for Real Time Temperature Monitoring - WiFi

sierra monitor corporation Fire and Gas Detection Systems

Smart Solutions for Remote Monitoring and Alarms Active Ethernet I/O with Active OPC Server

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

WinCon Programmable Automation. Controller

PIEZOMETER AIRFLOW MEASURING RING

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Configuring PROFINET

PROBA 4. In control of banana ripening. World leaders in process control.

M2M/IoT Solutions.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Section TELEPHONE AUTOMATIC DIALER SYSTEM

SCADAPack 530E 535E. remote Programmable Automation Controller

THERMAL MANAGEMENT SOLUTIONS

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Provides one channel for Ethernet over existing

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Application Note: Monitoring Branch Circuit Loads in Critical Facilities

MLC TM Maximum Productivity and Versatility for Control without Compromise!

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

The Business case for monitoring points... PCM architecture...

NGSS Data Consolidator (DC)

Centro-Matic Automatic Lubrication Systems System Controls

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Climate Ready Control Systems Technical Specifications

Multi-Range Programmable DC Power Supplies 9115 Series

Early Evaluation Center

Evaluation Form Technical Review Paper. Team Members: Michael Fojas, Katrina Kumm, Nick Migliaccio, Mark Peterson,

PRODUCT LIST Facility DDC Access WebXL DDC

DOC# IMBU-PB-REMOTE-MONITORING-01-EN IMBU. Remote monitoring of industrial equipment

4-CH Hybrid Digital Video Recorder

securityprobe 5E Standard

INSTALLATION MANUAL XM3 Reader

Tracer Summit Web Server

Smart relays Zelio Logic Step into an intuitive world!


Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

PowerCommand 500/550 Remote Monitoring System

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Installation manual. Generator Paralleling Controller GPC multi-line C

IntesisBox Modbus Server Fidelio IP

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Technical Information POWER PLANT CONTROLLER

ABB PSPS Erich Steinmann; Generator control-2013

Executive Summary. Technical Description

How To Run An Nport I5000A Device Server

Rosemount 333 HART Tri-Loop

The Total Package. Where innovative ideas are born. Free software suite upgrades for life Free technical support Hands-on PLC and OI training

TAC Vista Family TAC Xenta 700 Everything You Need to Monitor and Control Your Building

Temperature & Humidity SMS Alert Controller

1 Application Description Objective Goals... 3

Phase Modular Finally the benefits of Modular ups are for all

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Transcription:

GasGard 100 Control System Because every life has a purpose...

MSA Providing Fixed Gas and Flame Detection Solutions. It is critical for plant managers and personnel to have a proactive and diagnostic approach to understanding, analyzing and responding to conditions present inside complex plants and structures, where safety is paramount. Concise records that have the capacity to chronicle events, with corresponding actions, are imperative. Enter the new GasGard 100 Control System from MSA. At the heart of this personal computer (PC)-based or stand-alone Data Acquisition Platform, is proven technology from yokogawa that offers an intelligent approach to data acquisition and control raising the bar in Fixed Gas and Flame Detection. The GasGard 100 Control System is a scalable, high performance data acquisition/data-logging platform. Its open Ethernet connectivity, with web-based configuration and data monitoring functions, allow GasGard 100 Controllers to handle a wide range of monitoring and historical logging functions. See real time trends with your web browser from any PC without the need for specialized software! The flexible, modular architecture of the GasGard 100 Control System s main module can manage anywhere from one to six I/O modules on the backplane. Up to six GasGard Controllers can be networked together to create a complete system. With this capability, each GasGard 100 Controller can serve as a measurement node, monitoring a subgroup of sensors, where all communicate back to a Master GasGard Controller. This can minimize the length of wire and conduit typically necessary for adequately monitoring a facility. The GasGard 100 Control System provides fully integrated measurement, display and recording platforms, that when equipped with MSA s extensive line of transmitters and sensors, forms a complete gas detection solution. Easy User Interface, Intelligent Architecture and Innovative Functionality

The 10.4" TFT SVGA LED Panel PC with resistive touchscreen provides improved, intuitive and smart operator control. LED backlight auto-dimming meets the high demands of harsh environments. 3 www.msagasdetection.com

GasGard 100 Control System Highly Flexible System Configurations Main module serves as the data acquisition engine and LAN connectivity, and manages anywhere from one to six I/O modules on the backplane By linking two or more strategically placed GasGard 100 Controllers to the central controller, you can decrease wiring and conduit expenses Communications Communicate with both Analog and Modbus field devices Interface with PLC s and other control devices through Modbus/TCP and Modbus/RTU EtherNet provides easy connection to allow modification to your system. Configure, save and view data remotely via touchscreen or PC Data Monitoring Customize your layout configuration. Create your own viewing screen by choosing bar graphs, digital read outs, trending analysis, and more Delivers Access for Multiple Users. Simply connect the GasGard 100 Control System simultaneously to multiple PCs to monitor and share measured data remote real-time monitoring is available for those times when you can t be physically present

Event and Data Functions Built-in trigger function allows data recording to be started based on alarm values, time, external contact input, or other parameters. Progress continuously or according to a specified data length Data thinning function allows portions of measured data to be omitted, at regular intervals during measurement, before data is recorded Using the trigger and data thinning functions together provides "coarse" recording of general data and captures specific conditions during out of the ordinary events Data Reporting Capabilities Keep facility managers, executives and stakeholders informed with peak efficiency Create customized hourly, daily, weekly, and monthly reports that can be saved to the system s compact flash (CF) media and automatically uploaded to an FTP server for further processing and review 5 Email Alert Feature When you can t be physically present, utilize remote real-time monitoring and continuous plant status updates React immediately with email messaging feature; you are instantly alerted to out of the ordinary occurrences as they occur Alerts can be sent as a result of alarm conditions, report generation, power failure or system error www.msagasdetection.com

GasGard100 Control System Delivers Flexibility, Performance and Affordability with Standard Configurations or Customization The GasGard 100 Control System delivers: A seamless integration A scalable platform A consistent user experience Unique data communications across buildings, industrial plants and data centers The GasGard 100 Control System s highly adaptable, smart controllers and MSA s extensive line of detectors and monitors, your data acquisition and control challenges can be solved. Our system is so adaptable and modifiable, we are able to provide standard configurations or we can customize an integrated gas detection system designed specifically to suit your needs.

Dedicated to Providing Complete Solutions for Your Gas Detection Needs For nearly a century, MSA has been at the forefront of hundreds of safety innovations, consistently pushing the envelope in ways that provide the highest levels of safety for workers across the world. With such a rich history in developing and manufacturing the highest quality, leading edge gas and flame detection instruments available, MSA established itself as the global leader in Fixed Gas and Flame Detection and remains dedicated to providing the best products, service, and support in the industry. We are proud to provide complete solutions for your gas detection requirements. you can select from a variety of enclosures, alarming devices, wiring, configurations and more. Call MSA today to learn more about our standard configurations or to construct your customized gas detection system. 7 www.msagasdetection.com

Specifications* POWER SUPPLy OPERATING TEMPERATURE 90 to 250 VAC 50/60 Hz Rack -20 C to 50 C (-4 F to 140 F) TyPES OF MEASUREMENTS CONNECTION MODES TERMINAL CONNECTIONS MAXIMUM NUMBER OF ANALOG INPUTS PER UNIT COMMUNICATION SPECIFICATION MAXIMUM NUMBER OF RELAyS PER UNIT RELAy CONTACT MODE RELAy CONTACT CAPACITy Enclosure 24x24 Fiberglass enclosure (accepts up to 6 I/O) shall not exceed 45 C; no internal power supply. With a 240W Internal power supply the reading shall not exceed 35 C 6x20 small enclosure (accepts up to 3 I/O) shall not exceed 45 C; no internal power supply. ma (standard), DC Voltage, DI (non-voltage contact), level (5 V logic) 2 wire or 3 wire, ma; RS485 (Modbus) Max 2.5m² (12AWG) stranded wire 50 MAXIMUM NUMBER OF ANALOG OUTPUTS 40 Standard Interfaces: 100Base-TX/10Base-T (auto detect), Ethernet FTP function, E-mail function, DHCP client function, SNTP function, HTTP function, Modbus TCP (server/client), Modbus RTU (master/slave), EtherNet/IP 60, programmable SPST (Form A), Normally energized/de-energized 250 VDC/0.1 A, 250VAC/2 A, or 30 VDC/2 A (resistance load) ANALOG OUTPUT TyPE MAXIMUM RANGE OF ANALOG OUTPUTS ENCLOSURE DIMENSIONS INGRESS PROTECTION DC voltage, DC current -11 to 11 V or 0 to 22 ma 24.0" L x 23.5" W x 8.70" D or 20.2" L x 16.2" W x 8.2" D With Display - 24.0" L x 23.5" W x 12" D Designed to meet NEMA 4X * Specification is based on standard configuration Approvals (rack only) CSA CSA22.2 No 61010-1, overvoltage category II, measurement category II, pollution degree 2 UL CE FM Conforms to UL61010B-1 (CSA NRTL/C) EMC directive; EN61326 Class A EN61000-3-2 EN61000-3-3 Low voltage directive; EN61010-1; overvoltage category II, measurement category II, pollution degree 2 Class I Division 2 Groups A, B, C, D Note: This bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products. MSA The Safety Company 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Phone 724-776-8600 www.msasafety.com U.S. Customer Service Center Phone 1-800-MSA-INST Fax 1-800-967-0398 MSA Canada Phone 1-800-MSA-INST Fax 1-800-967-0398 MSA Mexico Phone 01 800 672 7222 Fax 52-44 2227 3943 MSA International Phone 724-776-8626 Toll Free 1-800-672-7777 Fax 724-741-1553 Email msa.international@msasafety.com ID 07-0344-MC / Jan 2015 MSA 2015 Printed in U.S.A. www.msasafety.com