Designing Glass to Resist Wind and Snow Loads

Similar documents
Window Glass Design 5 According to ASTM E 1300

Spandrel Glass Types and Recommendations

Glass Technical Document

Standard Specification for Flat Glass 1

Pyroguard Wired Glass

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Thermal Breakage Prediction

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications

CHAPTER 24 GLASS AND GLAZING

Specifying Windows. Performance Standards

Standard Test Methods for Viscosity of Adhesives 1

Bracing Webs in Trusses that have Dissimilar Configurations

Manual of Petroleum Measurement Standards Chapter 11 Physical Properties Data

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1

Standard Specification for Laminated Architectural Flat Glass 1

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK

SAMPLE TEST PAPER - I

Sharp-Crested Weirs for Open Channel Flow Measurement, Course #506. Presented by:

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

How To Test For An Architectural Test

TSL Professional Services

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

LN240(30)P-3-xxx ( W poly)

CLEAR-DIVISIONS CENTERFOLD

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

Open Channel Flow Measurement Weirs and Flumes

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Optimum proportions for the design of suspension bridge

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Green Thread Product Data

CLEAR-DIVISIONS VARIOFOLD

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Impact-Resistant Windows and Sliding Glass Doors

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Foam Firmness Measurements IFD For Most Furniture And Bedding Applications

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

How To Test A Fume Cupboard

Layman's Guide to ANSI X3.182

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

CHAPTER 24 GLASS AND GLAZING

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Design of Cold-Formed Steel Shear Walls

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

Local buckling of plates made of high strength steel

3D Printing Design Guidelines Sierra College CACT

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

CHAPTER 2 HYDRAULICS OF SEWERS

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Standard Specification for Stainless Steel Bars and Shapes 1

Section 5A: Guide to Designing with AAC

Technical Notes 3B - Brick Masonry Section Properties May 1993

Tex-421-A, Splitting Tensile Strength of Cylindrical Concrete Specimens

ICC-ES Evaluation Report

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

(Issued 1 Dec. 1965) CRD-C METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

CLEAR-DIVISIONS APERTO

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

Aluminium systems profile selection

Connection Solutions

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Copyright 2011 Casa Software Ltd. Centre of Mass

Silicon temperature sensors. Other special selections are available on request.

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

Garden Windows Builders Vinyl

Metal Roofing Practical Design

Transcription:

Designing Glass to Resist Wind and Snow Loads One of the design requirements of glass used in buildings is to resist the loads created by wind and snow. ASTM E1300-02: Standard Practice for Determining Load Resistance of Glass in Buildings provides numerical and graphical procedures to help design professionals and other specifying authorities determine the appropriate glass thickness and type to meet specified wind and snow loads. The E1300 standard has been developed by a broad group of industry representatives and has evolved and expanded to its present form over a period of more than 10 years. E1300 does not address glass design issues related to thermal stress, for which we invite our customers to use PPG s Thermal Stress Update publication and related software tool. The purpose of this document is to familiarize PPG s customers with this standard, including its scope and limitations. Examples are shown and directions on obtaining a copy of the standard are given. Also, directions are given on how to obtain a software package, based on ASTM E1300-02, that can be used to produce compatible recommendations. Examples from the software package are also shown. Scope of E1300-02 E1300-02 includes procedures that address: Monolithic, laminated, and insulating glass constructions. Insulating glass units can have lites of same or different types and thickness. Insulating glass units can have one monolithic lite and one laminated lite, or can be comprised of two laminated lites. 1, 2, 3, and 4 sides supported conditions. Short or long duration uniform lateral loads. Calculated center-of-glass deflection. Specified probabilities of glass breakage. Glass Products NOT Covered Wired glass. Patterned glass. Etched, sandblasted, drilled, notched or grooved glass. Assumptions The procedures defined by ASTM E1300-02 include the following assumptions. Glass is properly glazed and free of edge damage. Glass has not been subjected to abuse. Surface condition of the glass is typical of in-service glass. Glass edge support limits the lateral deflections of the supported glass edges to less than 1/175 of their lengths. Center of glass deflection will not result in loss of edge support. PPG encourages its customers to purchase a copy of the ASTM E 1300-02 standard. Copies may be purchased on line at www.astm.org. Page 1 of 12

Using E1300-02 KEY CONCEPTS Glass Type Factor multiplying factor for adjusting the load resistance of different glass types. Specified Design Load magnitude (in kpa or lb/sq. ft.), type of load (wind or snow), and duration of the load given by the specifying authority. Nonfactored Load 3-second uniform load associated with a probability of glass breakage of 8 lites per 1,000. Load Share Factor multiplying factor derived from the load sharing between the two lites of equal or different types and thickness. Load Resistance the uniform lateral load that a glass construction can sustain based upon a probability of breakage and load duration. DESIGN PROCEDURE 1. Start with glass dimensions and specified design loading. Design load must be in psf or kpa. Wind velocity can be converted to psf as follows: Psf = 0.00256V 2 2. Formulate a trial design (glass thickness and type). 3. Use E 1300 to determine the load resistance (LR) and center of glass deflection. 4. If LR is greater than the specified design loading, then trial design is OK and you are done. 5. If LR is less than the specified design loading, then modify the trial glazing configuration and return to step 3. Note: For insulating glass units, compute the load resistance for each lite. The load resistance of the unit is the minimum of the two. Insulating Glass Unit Design Example Determine the glass thickness and glass types for an insulating glass unit with rectangular dimensions of 60 in. x 96 in. that is simply supported on all four edges. The 3-second duration design loading is 125 psf. 1. Trial Design Outboard Lite (#1): Nominal ¼ in. heat strengthened monolithic glass. Inboard Lite (#2): Nominal 3/8 in. heat strengthened laminated glass. 2. Determine the load resistance based on Lite #1. Use the nonfactored load chart for ¼ in. glass (See Fig. 1 on page 3). Thus, the nonfactored load for lite #1 (NFL1) is 28.8 psf. Note: You must interpolate between curves Page 2 of 12

FIGURE 1 (Ref. Fig. A1.6 in ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Plate Length (in.) 0 50 100 150 200 Plate Width (in.) 140 120 100 80 60 40 20 6.0 mm (1/4 in.) Glass Nonfactored Load Four Sides Simply Supported P b = 0.008 1 kpa = 20.9 psf 3-Second Duration 4.00 5.00 7.00 10.0 2.50 3.00 2.00 1.50 1.25 1.00 0.75 0.50 3000 2000 1000 Plate Width (mm) 0 0 0 1000 2000 3000 4000 5000 Plate Length (mm) 3. Determine the Glass Type Factor for Lite #1 (GTF1) from Table 2 (reproduced below). Thus, GTF1 = 1.8 TABLE 2 Glass Type Factors (GTF) for Insulating Glass Short Duration Load Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Lite No. 1 Monolithic Glass or Laminated Glass Type Lite No. 2 Monolithic Glass or Laminated Glass Type AN HS FT GTF 1 GTF 2 GTF 1 GTF 2 GTF 2 GTF 2 AN 0.9 0.9 1.0 1.9 1.0 3.8 HS 1.9 1.0 1.8 1.8 1.9 3.8 FT 3.8 1.0 3.88 1.9 3.6 3.6 Page 3 of 12

4. Determine the Load Share Factor for Lite #1 (LSF1) from Table 5 on page 6. Thus, LSF1 = 5.26 5. Calculate the Load Resistance (based on Lite #1): LR1 = NFL1 x GTF1 x LSF1 = 28.8 x 1.8 x 5.26 = 273 psf This meets the requirements, but you must check lite #2. 6. Determine the load resistance based on lite #2. Use the nonfactored load chart for 3/8 in. laminated glass (See Fig. 2 on page 6). Thus, the nonfactored load for lite #2 (NFL2) is 49.2 psf. 7. Determine the Glass Type Factor for Lite #2 (GTF2) from Table 2 (p. 3) Thus, GTF2 = 1.8 8. Determine the Load Share Factor for Lite #2 (LSF2) from Table 5 (p. 6) Thus, LSF2 = 1.23 9. Calculate the Load Resistance (based on Lite #2): LR2 = NFL2 x GTF2 x LSF2 = 49.2 x 1.8 x 1.23 = 109 psf This does not meet the requirements and therefore this trial design is not adequate. It is necessary to modify the glass thickness and/or types and perform another iteration of the process. 10. Modified Trial Design Outboard Lite (#1): Nominal 3/8 in. heat strengthened monolithic glass. Inboard Lite (#2): Nominal 5/16 in. heat strengthened laminated glass. 12. Determine the load resistance based on Lite #1. Use the nonfactored load chart for 3/8 in. glass (See Fig. 3 on page 7). Thus, the nonfactored load for lite #1 (NFL1) is 47.0 psf. 13. Determine the Glass Type Factor for lite #1 (GTF1) from Table 2 (p. 3). Thus, GTF1 = 1.8 14. Determine the Load Share Factor for lite #1 (LSF1) from Table 5 (p. 4). Thus, LSF1 = 1.56 15. Calculate the Load Resistance (based on lite #1): LR1 = NFL1 x GTF1 x LSF1 = 47.0 x 1.8 x 1.56 = 132 psf This meets the requirements, but you must check lite #2. Page 4 of 12

TD-108 16. Determine the load resistance based on lite #2. Use the nonfactored load chart for 5/16 in. laminated glass (See Figure 4 on page 7). Thus, the nonfactored load for lite #2 (NFL2) is 40.8 psf. 17. Determine the Glass Type Factor for lite #2 (GTF2 from Table 2 (p. 3) Thus, GTF2 = 1.8 18. Determine the Load Share Factor for lite #2 (LSF2) from Table 5 (p. 6) Thus, LSF2 = 2.80 19. Calculate the Load Resistance (based on lite #2): LR2 = NFL2 x GTF2 x LSF2 = 40.8 x 1.8 x 2.80 = 205 psf This meets the requirements. Since the load resistance of both Lite 1 and Lite 2 meet the requirement, this trial design is adequate. Page 5 of 12

TABLE 5 Load Share (LS) Factors for Insulating Glass Units Note: This reproduction represents only a portion of Table 5 as shown in ASTM E 1300-02 Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Lite No.1 Lite No. 2 Monolithic glass, Short or Long Duration Load or Monolithic Glass Laminated Glass, Short Duration Load Only Nominal Thickness (in.) 1/4 5/16 3/8 LS1 LS2 LS1 LS2 LS1 LS2 1/4 2.00 2.00 3.37 1.42 5.26 1.23 5/16 1.42 3.37 2.00 2.00 2.80 1.56 3/8 1.23 5.26 1.56 2.80 2.00 2.00 FIGURE 2 (Ref. Fig. A1.30 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Page 6 of 12

FIGURE 3 (Ref. Fig. A1.8 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Plate Length (in.) 0 50 100 150 200 Plate Width (in.) 140 120 100 80 60 40 10.0 mm (3/8 in.) Glass Nonfactored Load Four Sides Simply Supported P b = 0.008 1 kpa = 20.9 psf 3-Second Duration 7.00 10.0 4.00 5.00 3.00 2.50 2.00 1.50 1.25 1.00 0.75 3000 2000 1000 Plate Width (mm) 20 0 0 0 1000 2000 3000 4000 5000 Plate Length (mm) FIGURE 4 (Ref. Fig. A1.29 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Page 7 of 12

Center-of Glass Deflection ASTM E 1300-02 includes procedures for calculating the center-of-glass deflection. An example of this calculation, using the above design example, the procedure is as follows. 1. Calculate the center-of-glass deflection for lite #1 under the specified design load. Load carried by lite #1 (P1): P1 = Specified Load /LSF1 = 125 psf/1.56 = 80.1 psf Aspect Ratio (AR) = long dimension /short dimension = 96 in./60 in. = 1.6 Load * Area 2 = = 80.1 psf * (40 sq. ft.) 2 = 128,160 pounds-ft 2 = 128 kip-ft 2 Using Figure 5 on page 9: Project a vertical line (shown in red) from 128 kip-ft 2 along the horizontal axis. Project a horizontal line (shown in green) from the intersection of the vertical line with the curved line for Aspect Ratio = 1.6 (determined by interpolation between curved lines for AR =1 and AR =2). 1. The approximate center-of-glass deflection is then determined by the intersection of the horizontal (green) line with the vertical axes as 0.89 in. 2. Calculate the center-of-glass deflection for lite #2 under the specified design load. Load carried by lite #2 (P2): P1 = Specified Load /LSF2 = 125 psf/2.80 = 44.7 psf Aspect Ratio (AR) = long dimension /short dimension = 96 in./60 in. = 1.6 Load * Area 2 = = 44.7 psf * (40 sq. ft.) 2 = 71,520 pounds-ft 2 = 71.5 kip-ft 2 Using Figure 6 on page 9: Project a vertical line (shown in red) from 71.5 kip-ft 2 along the horizontal axis. Project a horizontal line (shown in green) from the intersection of the vertical line with the curved line for Aspect Ratio = 1.6 (determined by interpolation between curved lines for AR =1 and AR =2). 3. The approximate center-of-glass deflection is then determined by the intersection of the horizontal (green) line with the vertical axes as 0.83 in. 4. The approximate center deflection of the insulating glass unit is the larger of the calculated center-of-glass deflections for lite 1 and lite 2. Thus the approximate center-of-glass deflection would be 0.89 in Page 8 of 12

FIGURE 5 (Ref. Fig. A1.8 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA FIGURE 6 (Ref. Fig. A1.29 from ASTM Standard) Extracted, with permission, from E 1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA Page 9 of 12

Computer Based Version PPG encourages its customers to investigate this software through the Standards Design Group Website, www.standardsdesign.com Computer software, created by the Standards Design Group, is available that generates results that are consistent with ASTM E 1300-02. The software is easy to use and reasonably priced. Using the software is obviously much quicker and greatly reduces the chance for error that can result from the tedious manual procedure. Examples of input and output screens, based on the previous manual example are given here for reference. Window Glass Design Software Modified Trial Design Input Screen SI Units Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Page 10 of 12

Window Glass Design Software Modified Trial Design Results Screen (SI Units) Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Window Design Group Software Modified Trial Design Details Screen (SI Units) Reproduced, with permission, from Standard Designs Group Comprehensive Window Glass Design Plus Page 11 of 12

HISTORY TABLE ITEM DATE DESCRIPTION Original Publication 4/2/2003 This document is intended to inform and assist the reader in the application, use, and maintenance of PPG Flat Glass products. Actual performance and results can vary depending on the circumstances. PPG makes no warranty or guarantee as to the results to be obtained from the use of all or any portion of the information provided herein, and hereby disclaims any liability for personal injury, property damage, product insufficiency, or any other damages of any kind or nature arising from the reader's use of the information contained herein. Page 12 of 12