APPLICATION NOTE. Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

Similar documents
LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

A Guide to Acousto-Optic Modulators

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Polarization of Light

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Interference. Physics 102 Workshop #3. General Instructions

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Crystal Optics of Visible Light

Alignement of a ring cavity laser

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Using light scattering method to find The surface tension of water

Polarization Tutorial Polarizing Beamsplitter Cubes

Lab 9: The Acousto-Optic Effect

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Fiber Optics: Fiber Basics

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Acousto-optic modulator

Meadowlark Optics LCPM-3000 Liquid Crystal Polarimeter Application Note: Determination of Retardance by Polarimetry Tommy Drouillard

Mode-Locked Femtosecond Titanium:Sapphire Laser. Version Trestles-50

FIBER OPTIC ISOLATORS

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Fraunhofer Diffraction

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Coating Technology: Evaporation Vs Sputtering

LINOS distributors: Refer to Service Worldwide at the end of this catalog

ENGINEERING METROLOGY

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Liquid Crystal in Precision Optical Devices

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

5. Reflection, refraction and polarization

Laserlyte-Flex Alignment System

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Reflection and Refraction

Optical laser beam scanner lens relay system

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Optical Design Tools for Backlight Displays

Diffraction and Young s Single Slit Experiment

Grazing incidence wavefront sensing and verification of X-ray optics performance

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Optical Storage Technology. Optical Disc Storage

LASER TO FIBER SOURCE COUPLERS APPLICATION NOTES

Experiment 5. Lasers and laser mode structure

Phase Bulb Refurbation and Optmic Thin Film

Introduction to polarization of light

digital quality control fail pass at your fingertips Smart Metrology Solutions.

Custom Optical Solutions A NAVITAR COMPANY

Theremino System Theremino Spectrometer Technology

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Microlenses immersed in nematic liquid crystal with electrically. controllable focal length

Basic Optics System OS-8515C

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Guideline Laser Series

Laser expander design of highly efficient Blu-ray disc pickup head

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Optical Communications

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Chapter 6 Metal Films and Filters

Straightness Measurements for Accelerator Structures

Diode-pumped Nd:YAG laser

TECNOTTICA CONSONNI SRL CERTIFIED QUALITY MANAGEMENT SYSTEM COMPANY BY DNV UNI EN ISO 9001:2008

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

Light and its effects

Application Report: Running µshape TM on a VF-20 Interferometer

Measuring index of refraction

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

WOOD WEAR TESTING USING TRIBOMETER

Chapter 17: Light and Image Formation

Blackbody Radiation References INTRODUCTION

Applications. Blue IF 039, Green IF 062, Yellow IF 022, Orange IF 041, Red IF 090,Dark Red IF 091 IR pass IF 092, IF098, IF 093 Surface 1 5/2 0.

Application Note 3 Polarization and Polarization Control

X-ray thin-film measurement techniques

Raman spectroscopy Lecture

Ultrasonic Wave Propagation Review

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Spectroscopic Ellipsometry:

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Introduction to microstructure

Self-Guided Intense Laser Pulse Propagation in Air

The Wide Field Cassegrain: Exploring Solution Space

PHYA2. General Certificate of Education Advanced Subsidiary Examination June Mechanics, Materials and Waves

GRID AND PRISM SPECTROMETERS

1 of 9 2/9/2010 3:38 PM

One example: Michelson interferometer

Synthetic Sensing: Proximity / Distance Sensors

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LD Physics Leaflets P

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Atomic Force Microscope and Magnetic Force Microscope Background Information

Transcription:

APPLICATION NOTE Variable Attenuator for Lasers 6 Technology and Applications Center Newport Corporation

This application note details a simple and cost effective solution for the continuous attenuation of laser output power. The attenuator kit described is based on a half waveplate and polarizer. It is suitable for attenuation of a linearly polarized laser beam with a wavelength in the 690 nm -040 nm range and average power up to 00 watts (please refer to Table at the end of this Application Note). The schematic of the device is shown in Fig.. Laser polarization φ E o E e φ / wave-plate Polarizer Laser Principle of Operation Beam Stop Figure. Schematic of variable attenuator for lasers. The principle of operation is based on Malus Law. The intensity I of the polarized light that passes through the polarizer is given by I = cos ( θ ) () I o where I 0 is the input intensity, and θ is the angle between the beam s initial direction of polarization and the axis of the polarizer. Rotation of a / wave-plate mounted to a rotational stage allows continuous rotation of the beam s polarization direction. When combined with a polarizer, it provides variable attenuation according to (). Wave-plates are usually made of birefringent crystal cut parallel to the optical axis. The electric field E v of a linearly polarized light impinging on a wave-plate can be decomposed into two components parallel and perpendicular to the optical axis (Fig. ). The component that is parallel to the optical axis is called an extraordinary beam, and the component perpendicular to the optical axis is called an ordinary beam. If the index of refraction of the ordinary beam is higher than it is for the extraordinary beam, then the directions along, and perpendicular to, the optical axis are also called a fast and slow axis. The thickness of a / wave-plate is chosen such that the difference between the phases of two components of light after passing through the wave-plate (retardation) is equal to multiples of 80 or / wave. A zero-order / wave-plate is made of two crystals resulting in exactly 80 retardation or one / wave. The advantage of a zero order wave-plate is that / wave retardation is maintained over a much broader range of wavelengths. Rotation of the / wave-plate by ø degrees leads to ø degrees of polarization rotation. Intensity at the output of the attenuator is then given by I = cos (φ ) () I o where ø is the azimuth of the / wave-plate. Full range of attenuations from minimum to maximum is achieved by / wave-plate rotation from 0 to 45. S P Laser beam Figure. Zero order / wave-plate. The electric field E v of a laser beam decomposes into two orthogonal components. Rotation of the wave-plate by angle ø results in a polarization rotation of ø. Which Components do I Use? The choice of optical components is defined by the bandwidth and the power of the laser to be controlled. For a / wave-plate we recommend the Newport model 0RP5-. This achromatic zero-order wave-plate consists of two different birefringent crystals: crystalline quartz and magnesium fluoride (MgF ), in an air-spaced design for high power. Compared to zero-order quartz wave-plates, achromatic quartz MgF wave-plates offer excellent retardation accuracy over broad wavelength ranges as shown in Figure 3. Achromatic quartz MgF wave-plates are less expensive than achromatic polymer film wave-plates and also feature higher damage thresholds. Fig. 4 shows the 0RP5- half wave-plate mounted in a 5.4 mm housing to allow easy mounting in any of our manual rotation stages, such as the RM-5 or the RSP-T Retardance (waves) 0.55 7 A0I 0.5 Normal Incidence 0.45 700 800 900 000 Wavelength (nm) Figure 3. Retardation vs. Wavelength of the Newport / Wave-plate, model 0RP5-

P P S S Figure 4. Newport / Wave-plate, model 0RP5- The line on the mount defines the azimuth of the wave-plate. If aligned at 45 relative to the input polarization direction, the output beam polarization is rotated by 90. (5A) For a polarizer, we recommend the Newport model 0GL08AR.6 Glan-Laser Calcite Polarizer. It consists of two calcite cubes with the optical axis oriented parallel to each other (Fig. 5a). The electric field of the laser beam at normal incidence to the polarizer can be decomposed into orthogonal S and P components oscillating along the fast and slow axes of the crystal. Indices of refraction of calcite are different for S and P components. The cubes are aligned and then cut at an angle such that the S component undergoes total internal reflection and gets rejected through the side window. The P component passes through with minimal loss (see Fig. 5b). Note, the rejected light is not polarized. The model 0GL08AR.6 Glan-Laser Calcite Polarizer is designed for demanding applications requiring extreme polarization purity and high resistance to laser damage. The polarizers are air-spaced, select-grade calcite prism pairs with the prism interface angles optimized for minimum insertion loss. The housing mounts into standard 5.4 mm holders, and polarizers are offered with broadband AR coatings for the visible and NIR regions (see Fig.5c). We recommend holding the 0GL08AR.6 in the RM5 mount in order to easily align the polarization either parallel or perpendicular to the table top surface. Reflectance (%) (5B).0.5.0 0.5 (5C) AR.6 Broadband NIR AR Coating 0 Typical 0 600 700 800 900 000 00 Wavelength (nm) Figure 5. Newport Glan-Laser Calcite Polarizer, model 0GL08AR.6 The line on the mount corresponds to the direction of P polarization and defines the azimuth. The rejected S polarized light exits the polarizer through the opening on the side of the housing. A broadband AR coating provides less than % reflection from the input and output surface in the 690nm -040nm spectral region. 3

Setup and Alignment The experimental setup for output power control of a Spectra-Physics Mai-Tai Ultrafast Oscillator is shown in Figure 6. The two steering mirrors at the output of the laser are recommended in order to make the alignment as easy as possible and get the laser output to desired beam height. If more than a 0-0 mm of beam height adjustment is needed, the Newport BSD-A beam steering kit is easily utilized in addition to these two turning mirrors. The attenuator can be set up as follows:. Install the polarizer on the table and position it in a way that the laser beam passes through the center. Make sure that the back reflected beam is not traveling into the oscillator. Slightly tilt the polarizer in the horizontal plane. If the plolarizer or any other optical element needs to be aligned perfectly perpendicular to the laser axis, creating an opportunity for back reflections into the oscillator, a faraday isolator such as the ISO-05-800-BB-G is recommended.. Rotate the polarizer and align the azimuth at 0 relative to the horizontal plane. 3. Install a power meter after the polarizer and maximize the power by fine rotation of the rotation stage. 4. Install the / wave-plate in the beam path before the polarizer at normal incidence angle, and ensure that no back reflection gets into the oscillator. To achieve maximum attenuation, the azimuth of the / wave-plate should be at 45 relative to the horizontal plane. 5. Install a beam dump in front of the side window of the polarizer housing to capture the rejected beam. For constant monitoring of the power, the beam dump can be replaced with a power meter. Newport can provide power meters and detectors optimized for your applications. For ultrafast oscillators we recommend 84-PE powermeter and 88 P-00- detector. If the output power of the laser is known, as is the case with the Mai Tai Laser, then the attenuated power is equal to the difference between the laser power and the measured power. Total insertion loss of the attenuator, on average, is about 7%. Calculated and experimentally measured attentuation curves for the Mai Tai Laser, at different wavelengths, are shown in Fig. 7. Within the measurements error there is good agreement between calculated and measured values. Note that the attenuation sensitivity to the / wave-plate azimuth depends on the position on the attenuation curve; it is highest at 50% attenuation. Figure 6. Setup for controlling the output of the Spectra-Physics Mai Tai Ultrafast Oscillator Output Power 3 0 800nm 900nm 700nm 000nm 0 0 0 30 40 50 / wave-plate azimuth, deg Figure 7. Calculated (solid lines) and measured attenuation curves of the Spectra-Physics Mai Tai Ultrafast Oscillator at different wavelengths 4

Power Considerations The maximum beam diameter that the attenuator can accept is defined by the 0 mm clear aperture of the polarizer. In order to avoid beam clipping, we recommend a maximum beam diameter of 5 mm. Both the polarizer and the / waveplate are rated for 500 W/cm damage threshold. The table below defines the maximum allowed power for different beam diameters. Parts List The following components are used to attenuate the Spectra-Physics Mai Tai Item Steering mirror SN00 -F3K 0Q0UF.35 Description SUPREMA Optical Mount,.0-in diameter Broadband 45 Ultrafast Mirror,.0-in diameter, Low Dispersion Coating Quantity Table Maximum allowed laser power vs. beam diameter SP- VPH--P Standard Post,.0-in length Standard Pedestal Post Holder,.9-in Height Beam Diameter (mm) 5 4 3 Laser Power (W) 00 64 36 6 4 For example, if the beam diameter is mm, the maximum laser power at the attenuator should not exceed 4 W. In the case of the Mai Tai Femtosecond Oscillator, the beam diameter is. mm. The damage threshold will be reached at 5.6 W, which is well above the specified power of.4 W at 800 nm. Wave-plate 0RP 5- RSP-T VPH--P SP- Polarizer 0GL0 8AR.6 RM5 Achromatic Zero-Order Wave Plate, / Wave Retardation Rotation Stage, -in Aperture Standard Pedestal Post Holder,.9-in Height Standard Post,.0-in length Glan-Laser Calcite Polarizer, 650 000 nm Polarizer Rotation Mount VPH--P Standard Pedestal Post Holder,.9-in Height SP- Standard Post,.0-in length Beam dump PL5 Beam Dump LH -OBJ Microscope Objective Lens Mount SP- Standard Post,.0-in length VPH--P Standard Pedestal Post Holder,.9-in Height Screw set SK-SH -Q0 Stainless Steel Screw Kit NOTE: The same setup will work for the Spectra-Physics Tsunami Ultrafast Oscillators by exchanging the posts and holders (SP- and VPH--P) with 3 posts and holders (SP-3 and VPH-3-P). 5

Newport Corporation Worldwide Headquarters 79 Deere Avenue Irvine, CA 9606 (In U.S.): 800--6440 Tel: 949-863-344 Fax: 949-53-680 Internet: sales@newport.com Visit Newport Online at: www.newport.com Newport Corporation, Irvine, California, has been certified compliant with ISO 900 by the British Standards Institution. Copyright 006 Newport Corporation. All Rights Reserved. DS-08067