Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

, User s Manual

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

G670 Intermittent Pilot Ignition Controls

Magnetic Starter - 30A, 120/240V Coils

*.ppt 11/2/ :48 PM 1

INSTALLATION & SERVICE MANUAL. Display Panel

E2 Series Electric Furnaces

Digi-Motor Installation Guide


SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Installation Instructions for Alarm Module Kit A043F059

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION INSTRUCTIONS

Owner's/Installation Manual

DC400 Dispensing Cutoff System

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

1R / 4-BUTTON SERIES

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Wiring Diagram. Diplomat 400V 3N.

NGC-30-CR -CRM -CRMS -CTM -CVM

Technical Information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Installation Instructions

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Application Engineering

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Oil and Coolant Circulating Heating System. Model - OCSM

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

instruction rev /13/2012

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

HM-W536 Install Guide

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Part Number:

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation Instructions. Thermo Call TC3

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Model. Roof-Top Air Conditioner CARAVAN MODEL B3200 TYPE INSTALLATION & OPERATING INSTRUCTIONS B3200

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

2003/2004/2005 TOYOTA COROLLA

Fan, Cypress / GreenField Installation Instructions (sku )

PUSH BUTTON START INSTALLATION MANUAL

Manual for Fire Suppression & Methane Detection System

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

Your safety and the safety of others are very important.

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Introduction. If you have further questions Call Hayward s tech service department at

Model SETR-50 and SETR-51 Trim Tab Control

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Medium voltage VCP-W MR2 (integral racking)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

User s Information/Installation Instructions

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

10.1 Indoor Unit Error Display

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Install Guide 3M-50. Caution. Caution

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Model 1756 Test Lead Kit

AIR CONDITIONING SYSTEMS

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Triac Printed Circuit Board Replacement

Downflow Furnace Models *FD14DCLFR000D *FD17DCLFR000D *FD21DCLFR000D *FD24DCLFR000D

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

INTRODUCTION INTERLOCK KIT K-8110

TOOL SVC NUMBERS: , SVC CONTENTS ITEM QTY DESCRIPTION PART NUMBER 1 1 CUTTING TOOL EXTRACTION TOOL/PART#

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

Allen-Bradley HP AC Line Filter Kit

Nordson. Atlanta, Georgia TECHUlCAL PUBLICA? lon O MANUAL PARENT MACHINE INTERLOCK SERIES 2000 APIPLICATORS. Publication No.

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

MicroTech III Unit Controller for Water Source Heat Pump Units


Section 1: Safety. General Safety. Recognizing Safety Precautions. Locking Out the Machine. Safety Circuits. Interpreting the Light Column

MicroTech III Unit Controller for Water Source Heat Pump Units

Generator Transfer Switch Model # HTS15-AUTO

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Transcription:

RPHASE3001A02 RPHASE3002A00 RPHASE3002A01 Split Systems, 6 to 12.5 Tons (21.5 to 39.9 kw) Rooftop Units, 3 to 25 Tons (10.5 to 87.9 kw) Packaged Heat Pumps Phase Monitor Accessory 50/60 Hz Installation Instructions TABLE OF ONTENTS PAKAGE ONTENTS... 1 SAFETY ONSIDERATIONS... 1 GENERAL... 1 Phase Reversal Protection... 2 Phase Loss Protection... 2 INSTALLATION... 2 Install Phase Monitor... 2 For R -22 Units... 3 For R -410A Units... 3 IMPORTANT: Read these instructions completely before attempting to install the accessory. PAKAGE ONTENTS RPHASE3001A02 (208/230V and 460V) QTY 1 ONTENTS Phase Monitor Part No. HK35A003 1 Installation Instructions 4 6B --- 20 x 3/4 LG screws 1 Harness Assembly QTY 1 PAKAGE ONTENTS RPHASE3002A00 (575V) ONTENTS Phase Monitor Part No. 48HG503588 1 Installation Instructions 4 6B --- 20 x 3/4 LG screws 1 Harness Assembly SAFETY ONSIDERATIONS Installation and servicing of air -conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform the basic maintenance functions. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and AUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. AUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.! WARNING ELETRIAL SHOK HAZARD Failure to follow this warning could result in personal injury and/or death. Before performing service or maintenance operations on unit, turn off main power switch to unit. If gas unit, shut off gas supply before shutting off main power. TAG DISONNET SWITH WITH A SUITABLE WARNING LABEL. opyright 2009 A / BDP D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 11/09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. atalog No: IIK ---RPHASE01 ---03 Replaces: IIK ---RPHASE01 ---02

RPHASE GENERAL The Phase Monitor accessory will monitor the sequence of three-phase electrical systems to provide phase reversal protection. The Phase Monitor will also monitor the phase voltage inputs (L1, L2, L3) to provide phase loss protection for a three -phase device. The Phase Monitor will work on either a Delta or Wye power connection. Phase Reversal Protection The phase monitor has a bypass function based on line cycles that is factory set for 10 minutes. If the phase monitor determines that all phases are in correct relationship for 10 consecutive minutes and 24 vac is applied, relay K1 will remain energized regardless of the phase sequence of the inputs. (See Fig. 1.) The bypass function will be reset if all three phases are restored in a phase loss event. The control operation timing is based on 60 Hz system. When the control is used on 50 Hz system, the bypass time may be longer since this timer is based on line cycles. Phase Loss Protection If the phase monitor senses that any of the 3 inputs (L1, L2, L3) does not have A voltage, relay K1 is de -energized. This phase loss protection is always active as long as 24 vac is applied and is not affected by the bypass function. In the event of phase loss, the bypass function is reset. Relay K1 is re-energized only when all three phases are restored and are in correct sequence. INSTALLATION Install Phase Monitor Remove access panel and control box cover. Attach the Phase Monitor to the high voltage section on the control box using 2 sheet metal screws. (See Fig. 1.) GRN- EQUIP GND H GRN- FIELD 11 21 OL1 4 3 T1 POWER 12 22 T3 OM SUPPLY BLU 13 23 4 OL2 3 T2 AP OFM L1 L2 L3 AP OFM PHASE MONITOR K1 ONTATOR OM 24 VA TRAN ONNETION BOARD (TB) B 3.2 AMPS RED 24 1 R 2 Y 3 Y2 4 W1 5 W2 6 G LEGEND ontactor B ircuit Breaker H rankcase Heater OM ompressor EQUIP Equipment GND Ground OFM Outdoor Fan Motor OL Overload TB Terminal Block TRAN Transformer 7 8 Fig. 1 - Typical Wiring Phase Monitor 07481 2

For R -22 Units Make Electrical onnections (See Fig. 1) 1. onnect field-supplied wire from L1 on Phase Monitor to 1 terminal 11 on compressor contactor 1. 2. onnect field-supplied wire from L2 on Phase Monitor to 1 terminal 12 on compressor contactor 1. 3. onnect field-supplied wire from L3 on Phase Monitor to 1 terminal 13 on compressor contactor 1. NOTE: For units with two-pole contactor, connect L3 on Phase Monitor to L3 of field power supply. 4. onnect field-supplied wire from OM terminal on Phase Monitor to terminal on control transformer (TRAN). 5. Disconnect the wire from the control transformer (TRAN) to terminal R on the connection board (TB). 6. Reconnect this wire to 24 vac terminal on Phase Monitor (to circuit breaker [B] which is connected to terminal 24 on transformer [TRAN]). 7. onnect field-supplied wire from ontactor terminal on Phase Monitor to R terminal on connection board (TB). 8. Restore power to unit and check unit operation. For R -410A Units 1. Disconnect power to unit and install lockout tag and wait 5 minutes. Secure power to the rooftop unit and wait 5 minutes. 2. Install the phase monitor module in the unit control box as shown in Fig. 2. Use the screws provided in the kit, screwing into the pre -drilled holes in the back of the control box. 3. Using the provided wiring harness, connect the female molex plug to male connector on the units mounted terminal board. See the terminal board diagram on Fig. 2. 4. ut Jumper 1 on control board. (See Fig. 5-7.) 5. a. For 208/230-460V - Route the wiring harness along the top of the control box connecting the pink wire to the ONTATOR spade connector, the red wire to the 24VA spade, and the brown wire to the OM spade of the phase monitor module. (See Fig. 3.) b. For 575V - Route the wiring harness along the top of the control box connecting the pink wire to the Y-OUT spade connector, the red wire to the Y spade, and the brown wire to the spade of the phase monitor module. (See Fig. 4.) 6. On the phase monitor module, connect the black wire to the L1 terminal, the yellow wire to the L3 terminal and the blue wire to the L2 terminal. 7. For All Units with 3 Phase Indoor Fan Motor On the indoor fan contactor (IF), connect the black wire to terminal 11 and the blue wire to terminal 13. On the compressor contactor (), (1) or (2). connect the yellow wire to terminal 13. (See Fig. 5.) For YA and PHP 208/230-460V and One Phase Indoor Fan Motor On the compressor contactor () or (1) or on the Indoor Fan ontactor (IF) on units with crankcase heater, connect the black wire to terminal 11 and the yellow wire to terminal 13. onnect the blue wire to the input power terminal board (TB). (See Fig. 6.) For All PA 208/230-460 -575V with One Phase Indoor Fan Motor and YA and PHP 575V with One Phase Indoor Fan Motor On the indoor fan contactor (IF), connect the black wire to terminal 11 and the blue wire to terminal 23. On the compressor contactor () or (1), connect the yellow wire to terminal 13. (See Fig. 7.) 8. ut the jumper on the terminal board. (See Fig. 2.) 9. Restore power to rooftop unit. RPHASE 3

Phase Monitor Relay Location RPHASE UT FOR REHEAT/HP UT FOR REHEAT/HP X X G G W2 W2 W1 W1 Y2 Y2 Y1 Y1 R R T-STAT DD DD T-STAT EON SAT/OAT O R OUPANY R REHEAT/HP U TF ONTROL BOARD U N REMOTE I SHUTDOWN T S H U T D O W N LO/OMP LO/OMP UT FOR REMOTE SHUTDOWN SMOKE SHUT- DOWN UT FOR W 24V I UT FOR OUT SMOKE R DETETOR I I N G SMOKE ALARM LPS IRUIT 2 HPS LPS IRUIT 1 HPS Fig. 2 - ontrols Box Showing Mounting Location and Recommended Wire -Routing Path with Exploded View of Terminal Board (YA with 3 -Phase Indoor Fan Motor Shown) 09490 4

PNK RED O3A O1A HK35A003 BLU Fig. 3 - Phase Monitor Module Detail (208/230V and 460V) 08480 RPHASE PNK RED BLU Fig. 4 - Phase Monitor Module Detail (575V) 08481 5

RPHASE Fig. 5 - Wiring Diagram 08482 or IF Fig. 6 - Wiring Diagram 08483 Fig. 7 - Wiring Diagram 08484 6