MCSA Identifying Rotor and Stator Electrical Faults

Similar documents
APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS

Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

THIS paper reports some results of a research, which aims to investigate the

Unit 33 Three-Phase Motors

Chapter 4.5: Electric Motors, Variable Speed Drives

Induction Motor Theory

Motor Fundamentals. DC Motor

Machine diagnosis: Quick and easy through FFT analysis

DC MOTOR ANALYSIS & TROUBLESHOOTING

IV. Three-Phase Induction Machines. Induction Machines

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Synchronous motor. Type. Non-excited motors

Electric Motor Repair: Research Project on Soft Foot

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SYNCHRONOUS MACHINES

WIND TURBINE TECHNOLOGY

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

AC-Synchronous Generator

Basics of Electricity

Motor Current Signature Analysis and its Applications in Induction Motor Fault Diagnosis

Module Title: Electrotechnology for Mech L7

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

Introduction. Upon completion of Basics of AC Motors you should be able to:

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Principles of Adjustable Frequency Drives

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

On the Influence of Stator Slot shape on the Energy Conservation Associated with the Submersible Induction Motors

Lab 8: DC generators: shunt, series, and compounded.

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

MOTOR CURRENT SIGNATURE ANALYSIS TO DETECT FAULTS IN INDUCTION MOTOR DRIVES FUNDAMENTALS, DATA INTERPRETATION, AND INDUSTRIAL CASE HISTORIES

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

Lab 14: 3-phase alternator.

How the efficiency of induction motor is measured?

Induction Motor Testing and Evaluation

Power Quality Paper #3

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Single-Phase AC Synchronous Generator

EVANS ENTErprises, Inc.

8 Speed control of Induction Machines

Welcome to Linear Controls Quarterly Training

13 ELECTRIC MOTORS Basic Relations

Motor Protection Voltage Unbalance and Single-Phasing

Transformer circuit calculations

Faults Detection and Remote Monitoring System for Induction Motors using MCSA Technique

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Troubleshooting with ABS Service Data Kit

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

CONDITION MONITORING AND FAULT DIAGNOSIS OF INDUCTION MOTOR USING MOTOR CURRENT SIGNATURE ANALYSIS

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

NATIONAL CERTIFICATE (VOCATIONAL)

CONTINUOUS AUTOMATED FLUX MONITORING FOR TURBINE GENERATOR ROTOR CONDITION ASSESSMENT

Voltage Unbalance and Motors

GE Energy. Motors Product Line

ET 332b Ac Electric Machines and Power Systems

48 SERIES Relay interface modules 10 A

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

60 Series - General purpose relays 6-10 A. Features

. Failure. Analysis... Report...

SECTION VARIABLE FREQUENCY DRIVES

Principles and Working of DC and AC machines

3. Three phase winding technology

Understanding the Alternator

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

49 Series - Relay interface modules A. Features

Specifying a Variable Frequency Drive s

Diesel Engine Driven Generators Page 1 of 6

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Vibration Analysis Services. FES Systems Inc. 1

Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao

Case Studies on Paper Machine Vibration Problems

REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO)

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Simulation of Ungrounded Shipboard Power Systems in PSpice

Current Transformers

COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

AC Induction Motor Slip What It Is And How To Minimize It

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Embedded Control and Diagnostics Algorithm with Fault Prediction and Analysis of AC Induction Machines

Intelligent Data Mining for Turbo-Generator Predictive Maintenance: An Approach in Real-World

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

R448 & R448 V50 A.V.R.

Offshore Platform Powered With New Electrical Motor Drive System

USER MANUAL THE RESOLVER

C Standard AC Motors

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Vibration analysis: what does it mean?

Power Plant Electrical Distribution Systems

Pump Vibration Analysis

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Solving VFD-sourced Bearing Current Problems in AC Motors.

Transcription:

MCSA Identifying Rotor and Stator Electrical Faults Howard W Penrose, Ph.D. ALL-TEST Pro A Division of BJM Corp Old Saybrook,, Connecticut Welcome to the last of the 2003 Motor Diagnostic training presentations presented by ALL-TEST Pro, A Division of BJM Corp. In this presentation we will focus on rotor bar and stator electrical faults in an AC induction motor. A short overview of how the ALL-TEST PRO MD kit operates will also be introduced. BJM Corp is a submersible pump, motor diagnostic instrument and software manufacturer established in 1983. BJM Corp is a USA Federal Government GSA Approved Supplier and a US Department of Energy Best Practices Allied Partner. Dr. Penrose is the General Manager of the ALL-TEST Pro Division of BJM Corp. Dr. Penrose is the Vice Chair of the Connecticut Section of IEEE and is active in the development and implementation of IEEE and other industry specifications.

Presentation Outline for 2004 Energy Applications in Reliability Introduction to MotorMaster+ + 4.0 Motor System Energy Opportunities Performing an MM+ Survey Using MD Technology Implementation of a Motor Management Program Condition Based Monitoring and It s Application in Reliability Time to Failure Following MCA Fault Detection Business Impact of Motor Diagnostics Successful Application of Motor Diagnostics: Case 1 Successful Application of Motor Diagnostics: Case 2 Successful Application of Motor Diagnostics: Case 3 MCSA Identifying Rotor and Stator Electrical Faults is the final installment of the 2003 series by ALL-TEST Pro. It discusses the ALL-TEST PRO OL motor circuit analyzer, rotor faults and stator winding faults. In 2004, we shall change direction slightly with an application directed approach with a series of 10 to 15 minute presentations. The series will be issued monthly along with a supporting IQ Quiz. The following IQ Quiz will encompass the complete series with those successfully completing the quiz receiving a Certificate of completion. The presentations for 2004 include: Energy Applications in Reliability Introduction to MotorMaster Plus 4.0 Motor System Energy Opportunities Performing an MM+ Survey Using motor diagnostic technology Implementation of a motor management program Condition based monitoring and its application in reliability Time to failure following mca fault detection Business impact of motor diagnostics Successful application of motor diagnostics case 1 Successful application of motor diagnostics case 2 Successful application of motor diagnostics case 3

ALL-TEST Pro Motor Diagnostics Hand Held Full Power Quality and Motor Current Signature Analysis Capabilities Auto-Analysis of Electric Motor Electrical and Mechanical Condition Does not require Number of Rotor Bars or Stator Slots to Analyze PQ and MCSA Modules Integrated with EMCAT Motor Management Software Can also be used as Stand-Alone System (ATPOL and Power System Manager) The ALL-TEST Pro line of Motor Diagnostic instruments includes the ALL-TEST PRO OL motor current signature analyzer. It is a hand-held instrument which maintains full Power Quality, data logging and motor current signature analysis data collection. The included software performs automated analysis of electric motor electrical, mechanical and power quality health. The ATPOL and Power System Manager software modules are fully integrated with the EMCAT motor management software and can operate as independent software programs. The ALL-TEST PRO OL system does not require rotor bar or stator slot information to analyze data.

You ve Collected Data, Now What? ATPOL only requires HP/kW, Voltage Rating, Current Rating, Nameplate Speed. Entering bearing information, rotor bars and stator slots improves early fault analysis. The ATPOL system only requires nameplate horsepower or kw, voltage, current and speed. Rotor bar, stator slot and bearing information assists in earlier fault analysis. Steps in a standard analysis include: 1. Collection of data from the MCC, disconnect or motor 2. Upload of data through the EMCAT Power System Manager software 3. Enter basic nameplate information into the ATPOL software 4. Run analysis through the ATPOL software 5. Print a summary report Detailed independent analysis of low and high frequency data is available within the ATPOL software. In this presentation, we will start identifying how to perform independent analysis using FFT spectra of demodulated voltage and current.

Rules for Quick Analysis PPF Sidebands around LF De-Mod current indicate rotor issues Mechanical Faults: Peaks in Current but not in Voltage = Mechanical Electrical Faults: Peaks in both Current and Voltage = Electrical Bearing Faults Not divisible by Line Frequency Non-Integer when divided by Running Speed Frequency Peaks only in Current There are a number of simple rules for quick analysis of the condition of an electric motor and to assist in the analysis of types of faults: PPF Sidebands around Line Frequency demodulated current indicates rotor bar faults. In the high frequency spectra, Mechanical faults show peaks in current but no corresponding peak in voltage at the same frequency. Electrical faults show as peaks in both current and voltage. Bearing faults are not divisible by line frequency and will appear as a non-integer when the center frequencies are divided by the running speed frequency. Peaks also show only in current. In this presentation, we will focus on rotor analysis and a quick method of confirming stator electrical faults. Electrical faults are normally defined as winding shorts or internal coil unbalances.

Rotor Fault Sideband Values -dbdb Rotor Condition Assessment Recommended Action 60 Excellent None 54 60 Good None 48 54 42 48 36 42 30 36 <30 Moderate High Resistant Connection or Cracked Bars Broken Rotor Bars Will Show in Vibration Multiple Cracked/Broken Bars, Poss Slip Ring Problems Severe Rotor Faults Trend Condition Increase Test Frequency and Trend Confirm with Vibration, Plan Repair / Replace Repair/Replace ASAP Repair/Replace Immediately Rotor testing involves viewing the pole pass frequency sidebands around the line frequency peak. Pole pass frequency is calculated in one of two ways: Synchronous Running Frequency Running Frequency times the number of poles. For instance, a 4 pole motor with a 29.200 running frequency at 60 Hz would have a pole pass frequency of 30 Hz 29.2 Hz = 0.8 Hz times 4 poles = 3.2 Hz. Values less than 60 db sidebands would show a rotor in excellent condition requiring no action Values from 54 to 60 db would show a rotor in good condition requiring no action Values from 48 to 54 db would indicate a rotor in moderate condition with recommended trending Values from 42 to 48 db would indicate at least one high resistant joint or cracked bars with recommended trending. Values from 36 to 42 db would indicate broken rotor bars that may show in vibration Values from 30 to 36 would indicate multiple cracked or broken bars, as well as possible slip ring problems. Will require repair or replacement as soon as possible Values less than 30 db indicates severe rotor faults that requires immediate attention.

Rotor Analysis Example Single large PPF sidebands would indicate broken rotor bars as they increase towards the peak LF value. Multiple PPF sidebands indicate casting voids. In this case, multiple PPF-sidebands at -50dB or greater, would indicate minor rotor casting voids. In cases where signatures show significant sidebands, broken rotor bars would be indicated. In cases where harmonics of these sidebands exist at low levels, casting voids exist. In this case, multiple PPF sidebands in the 50 db range indicate significant casting voids. The light green lines indicate the PPF sidebands around the line frequency. Confirmation of the severity of the casting voids using motor circuit analysis should be performed at this point.

Stator Electrical Faults B A Possible Mechanical Fault Peaks show in current but not Voltage (A) These are separated by 2x Running Speed (29.907 Hz) The CF is 34 times RS -OR- RS sidebands of stator 60Hz Sideband Frequency Actual Finding 36 SS times RS = 1076.65 Hz +/- 60 Hz = 1016.65 (high peak) w/ RS Sidebands Stator Electrical Fault In this example, the frequencies indicated by A are separated by two times the running speed frequency. The Center Frequency actually shows 34 times running speed which does not match the number of rotor bars or stator slots. Alternately, these could indicate running speed sidebands around peak B. In this case, 36 stator slots times the running speed places a stator center frequency of 1076.65 Hz, which is 60 Hz higher than the peak at B. This would indicate a potential stator electrical fault.

Confirmation of Stator Electrical B A A Peaks are 1076.65 +/- 60 LF (1016.65 and 1136.65) B Peaks are RS sidebands of A Peaks Stator Electrical Fault Frequencies: SS x RS = 1076.65 Hz W/ LF Sidebands W/ RS Sidebands By reviewing the signature for stator electrical faults: Stator slots times running speed provides the center frequency. Line frequency sidebands with running speed sidebands around the line frequency sidebands. In this case, Peaks A are + and line frequency around the stator center frequency. The peaks labeled B are running speed sidebands around the A peaks. This would confirm that this is a stator electrical fault indication.

Confirmation Test and Analysis of Stator and Rotor Electrical Faults Winding Test Resistance T1-T2 0.009 T1-T3 0.009 T2-T3 0.009 Impedance 6 6 6 Inductance 1 1 1 Phase Angle 53 52 53 I/F -40-40 -40 Insulation #.# MCA Can Be Used Rotor Test 1.4 1.35 1.3 1.25 1.2 1.15 1.1 1.05 1 0.95 0.9 12 1 2 3 4 5 6 7 8 9 10 11 T1 T2 T3 If a potential fault is detected, motor circuit analysis can be used to confirm the finding from the MCC, disconnect or at the motor connection box. In this case, winding analysis shows that the stator and rotor are in good condition.

ALL-TEST Pro ALL-TEST Pro A Division of BJM Corp 123 Spencer Plain Rd Old Saybrook,, CT 06475 Ph: 860 399-5937 Fax: 860 399-3180 3180 Email: alltest@bjmcorp.com www.alltestpro.com ALL-TEST PRO MD Kit ALL-TEST IV PRO 2000 ALL-TEST PRO 31 ALL-TEST PRO OL EMCAT Motor Management Software Motor Circuit Analysis Book M2000 Training Motor ATF-11 Armature Fixture On-Site and Classroom Training available For evaluating motor system health, ALL-TEST Pro provides the ALL-TEST PRO MD kit for motor diagnostics. It includes both motor circuit and motor current signature analysis systems integrated through the EMCAT motor management software system. On-site and classroom training is available. For more information, contact ALL-TEST Pro, A division of BJM Corp, 123 Spencer Plains Rd, Old Saybrook, Connecticut. Our phone number is 860 399-5937, fax number is 860 399-3180, sales and technical support email through alltest@bjmcorp.com and website www.alltestpro.com Dr. Penrose may be contacted via email at hpenrose@bjmcorp.com.