REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDS IN ITS ENTIRETY)

Similar documents
MATERIALS LICENSE. In accordance with the letter dated January 15, 2009,

MATERIALS LICENSE. 1. Honeywell International, Inc. 3. License Number: SUB-526, Amendment 6-1

MATERIALS LICENSE. Delaware City, Delaware Docket No Reference No.

GUIDE FOR THE PREPARATION OF RADIOACTIVE MATERIAL APPLICATIONS FOR WELL LOGGING OPERATIONS IN KENTUCKY

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

INFORMATION NOTICE: USE OF XRF DEVICES CONTAINING RADIOACTIVE MATERIAL North Dakota Department of Health Radiation Control Program (2/06)

64E-5 Florida Administrative Code 64E PART XIV LICENSING AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS SUBPART A GENERAL PROVISIONS

Wisconsin Chapter DHS 157- Radiation Protection Regulatory Guide May, 2010

105 CMR: DEPARTMENT OF PUBLIC HEALTH

Working Safely With Nuclear Gauges

Lecture 2 Macroscopic Interactions Neutron Interactions and Applications Spring 2010

Dose Standards and Methods for Protection. Radiation and Contamination

EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL. 2. Prevent the spread of contamination by covering the spill with absorbent paper.

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

Selection, use and maintenance of portable monitoring instruments

PART B REGISTRATION [LICENSURE] OF RADIATION MACHINE FACILITIES, [SERVICES] */ AND ASSOCIATED HEALTHCARE PROFESSIONALS

PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:

TROXLER TRANSPORTATION GUIDE

W. C. Reinig. Savannah River Laboratory E. I. du Pent de Nemours and Company Aiken, South Carolina 298o1

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE 8.4 (Draft was issued as DG-8036, dated April 2010)

X-ray Safety Manual 2013

Safety and Radiation Protection Office Working with X-Ray Equipment

IAC 10/1/14 Public Health[641] Ch 39, p.1

Application Note. ipix A Gamma imager to support various applications

James M. Pleasants Company

Additional Facility Details for Release of Waste Area 3 (Seattle, Washington)

Radiation Safety Committee College of William and Mary

Quality Assurance Testing of AtomLab Dose Calibrators

Radioactivity III: Measurement of Half Life.

Basics of Nuclear Physics and Fission

Complete Source Life Cycle Management. ReSource Program

PI Chemistry - PI 24 HEAVY WATER LEAKAGE - DETECTION. 1. Name and briefly describe the operation of five of:

SAFE MANAGEMENT OF SMOKE DETECTORS CONTAINING RADIOACTIVE SOURCES

LASER SAFETY MANUAL UNIVERSITY OF KENTUCKY POLICIES AND PROCEDURES FOR LASER USERS REVISED EDITION 2012 ISSUED BY

DOE Policy- Reporting of. Update

Introduction. Chapter 15 Radiation Protection. Regulatory bodies. Dose Equivalent. Regulatory bodies. Main Principles of Radiation Protection

notes MERRTT IS-302 Radiological Survey Instruments and Dosimetry Devices

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

APP C1 NAVAL RADIOACTIVE MATERIAL PERMIT REVIEW CHECKLIST NUCLEAR MEDICINE COMMAND: PERMIT NUMBER: TYPE OF ACTION:

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Radiation Rule Guide. Veterinary Facilities. Hawaii Administrative Rules, Chapter 11-45, Radiation Control. Hawaii State Department of Health

Section 4 RADIATION SAFETY RULES AND REGULATIONS

SECTION TWO PACKAGING, TRANSPORTATION AND STORAGE OF RADIOACTIVE MATERIALS

Mechanical Engineering and Material Handling Aspects of NSDF

How does a microwave oven work?

C I T Y O F S E L M A F I R E D E P A R T M E N T

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

ATOMS: ATOMIC STRUCTURE QUESTIONS AND ANSWERS

Itemized RAI Responses

SAFE MANAGEMENT OF SMOKE DETECTORS CONTAINING RADIOACTIVE SOURCES

PERSONNEL MONITORING AND DOSIMETRY POLICIES

September 15, Docket No General License (10 CFR 31.5)

318 DECREE. of the State Office for Nuclear Safety of 13 June 2202,

Transportation of Radioactive Material

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Azeri, Chirag & Gunashli Full Field Development Phase 3 Environmental & Socio-economic Impact Assessment. A10.1 Introduction...

HAZMAT Employee Training DOT/ NRC- Radioactive Materials Shipments Compliance with 49CFR and 10CFR 71

(2) "Interlock" means a device preventing the start or continued operation of equipment that could cause a radiation hazard.

PART 34--LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

NOTICE OF PROPOSED RULEMAKING TITLE 12. NATURAL RESOURCES CHAPTER 1. RADIATION REGULATORY AGENCY ARTICLE 1. GENERAL PROVISIONS

WIRELESS STATUS MONITOR

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Installation Manual DIAPHRAGM WELL TANK

December 26, Docket No License No Control No

Shielding Solutions Who Is Nelco? NELCO Locations. Five Market Segments. Shielding Products Diagnostic. Professional Affiliations

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

Environment-Laboratory Ambient Conditions

HAZMAT Employee Training DOT/ NRC- Radioactive Materials Shipments Compliance with 49CFR and 10CFR 71

SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

American Society of Agricultural and Biological Engineers

City of San Diego, CWP Guidelines

Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel

STANDARD PROCEDURES FOR ROOF MOISTURE SURVEYS

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Chemistry 13: States of Matter

Level 3 Science, 2008

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63

PHYA5/1. General Certificate of Education Advanced Level Examination June Unit 5 Nuclear and Thermal Physics Section A

Regulatory Guide. Radiation Safety in Industrial Radiography (FANR-RG-019) Version 0

Evaluation of 55-gallon Lead-Lined Calibration for the Gamma Modality of the High Efficiency Neutron Counter

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

75 Ω Transmission System

centre for radiation protection

Specific local rules for governing the use of the Niton XLt Environmental Analyser (portable XRF): Laboratory

V K Raina. Reactor Group, BARC

*Note: This document is an electronic (scanned) version of the original paper report and formatting may vary somewhat from the original.

Radiation Strip Thickness Measurement Systems

Wednesday 16 January 2013 Afternoon

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Transcription:

NO. : NC-646-D-135-B DATE: July 22, 2006 PAGE: 1 of 6 MODEL No.: 3242 MANUFACTURER/DISTRIBUTOR: Troxler Electronic Laboratories 3008 Cornwallis Road P.O. Box 12057 Research Triangle Park, NC 27709 (919) 549-8661 SEALED SOURCE MODEL DESIGNATION: ISOTOPE: MAXIMUM ACTIVITY: Troxler Drawing No. A-105162 which covers: QSA Global, Inc. Model No. CVN.CY2 Capsule Type X.1 Special Form Certificate No. USA/0632/S Cf-252 110 microcuries (4.07 MBq) Troxler Drawing No. A-105862 which covers: Isotope Product Laboratories Model # HEG-252 Special Form Certificate No. USA/0632/S Cf-252 110 microcuries (4.07 MBq) LEAK TEST FREQUENCY: 12 months PRINCIPAL USE: (G) Portable Moisture Density Gauge CUSTOM DEVICE: YES X NO

NO. : NC-646-D-135-B DATE: July 22, 2006 PAGE: 2 of 6 DESCRIPTION: The Model 3242 Laboratory Asphalt Content Gauge is a semi-fixed, non-portable laboratory analysis device form measuring the asphalt content of paving material. The device design is based on the principal of neutron thermalization via collisions with atoms of similar mass and incorporates a doubly-encapsulated neutronemitting californium-252 ( 252 Cf) radioactive source (neutron yield 3.8 x 10 5 neutrons/second) and a series of four helium-3 detector tubes. The device operation can be described as follows: fast neutrons, emitted from the source, traverse the test sample and are subsequently slowed down (thermalized) by collisions with hydrogen atoms of the asphalt. The thermal neutrons are then detected by the helium-3 detectors and counted over a specified time period. Due to the inability of these detectors to detect fast neutrons, the number of thermalized neutrons counted is directly proportional to the number of hydrogen molecules (primarily in the form of asphalt) present in the sample. The accompanying electronics then process the count rates and calculates the asphalt content using operator-supplied information (e.g. mass of sample, calibration data, etc.). Installation and setup of the device at the user s laboratory will be performed by the user following instructions provided in the accompanying Manual of Operation and Instruction. This device is designed to be setup, calibrated and used by personnel who have not been specifically trained radiation safety. Use of the device consists of preparing the sample pan of asphalt, unlocking the sample chamber door, and inserting the pan into the sample chamber. The control unit containing the electronics and software for the gauge is positioned several feet from the sample chamber which contains the source and detectors. The sample chamber and control unit are connected by an interface cable which transmits data to the control unit. Once testing has been completed, the sample chamber should be locked. DETAILS OF CONSTRUCTION: The model 3242 is constructed from four basic materials: aluminum, cadmium, high-density polyethylene, and stainless steel. High density polyethylene is used in the construction of the source holder, the barrier surrounding the source holder in the top of the device, the sample chamber walls and floor, and the base stand. Cadmium is used to shield the outside of the polyethylene source holder and to line the inside walls of the device in such a fashion that no neutron emitted from the sealed source could leave the device without passing through at least one thickness of cadmium. Stainless steel is used in the bottom of the sample chamber to cover the aluminum housing over the detectors, giving increased shielding in the direction of the emitted beam. Finally, aluminum is used as the main construction material in the fabrication of the rest of the device. This includes the device walls, top and bottom; sample chamber interior faces; and other similar structures exterior to the device. A circular hole is cut into the top interior face plate of the chamber to act as the neutron exit beam port. The overall design and construction of the device renders the source housing immoveable and access to the radioactive materials highly restricted. The entire device would have to be disassembled in order to gain access to the sealed source. Furthermore, the small sample chamber volume (10" x 7.5" x 4.5") precludes the operator from inadvertently being exposed.

NO. : NC-646-D-135-B DATE: July 22, 2006 PAGE: 3 of 6 LABELING: The Model 3242 is labeled in accordance with 15A NCAC 11.1626 and.0309. The labels contain the radiation symbol, isotope, activity, model number, serial number, name of distributor, and the words "CAUTION-RADIOACTIVE MATERIAL." DIAGRAM: See Attachments 1 and 2 for approximate source and label locations. CONDITIONS OF NORMAL USE: The Model 3242 is designed to be used by personnel who have not been specifically trained radiation safety to measure asphalt content of paving materials in a laboratory setting. The user will normally be near the device only for the time period necessary to load and unload the chamber. The source capsule has a recommended working life of 15 or more years under normal use conditions. Due to the 2.65 year half-life of the Cf-252 source, the gauge should be returned to Troxler every 3 years for source replacement and a thorough manufacturer's inspection. The device is designed for the following environments: Operating temperature Pressure Vibration Corrosion Fire -10 C to 70 C ambient Atmospheric Ranges from zero to mild (tested @ a displacement of 0.1" @ 12.5 Hz) Ranges from zero to corrosive +130 C (to melt the polyethylene shielding surrounding the source) PROTOTYPE TESTING: The Model 3242 underwent prototype testing for mechanical, structural, and radiological integrity using measurement methodologies and testing procedures found in ANSI Standard N538-1979. This prototype testing included stray radiation measurements of gamma dose rates at 5 cm, 30 cm, and 100 cm for the gauges in both the "on" and "off" configurations; testing of the gauges' safety features at room temperature and at an elevated use temperature of 105 C, and at a decreased use temperature of -40 C; a leak test of the radioactive source after the safety feature/temperature testing; and an engineering evaluation of the likelihood of source retention in the source housing following a severe accident involving fire. The results of the testing showed:

NO. : NC-646-D-135-B DATE: July 22, 2006 PAGE: 4 of 6 PROTOTYPE TESTING (continued) : (1) no safety feature failure or stray radiation increase over the range of temperatures tested and (2) no loss of radioactive material from the sealed source. There was no accident condition fire test conducted for this device. The assignment of Class 1 for the accident condition of the device is based on the 130 C melting point of the high density polyethylene shield around the neutron source. Although the 130 C temperature would not result in damage the source capsule that would allow for leakage, the captive protective source housing for the source would be lost. Therefore, the assignment of 1 is supported here. The results of the prototype testing support the assignment of an ANSI standard rating of ANSI-54-164-164-R1. EXTERNAL RADIATION LEVELS: See Attachment 3. QUALITY ASSURANCE AND CONTROL: Troxler Electronic Laboratories maintains a quality assurance and control program which has been deemed acceptable for licensing purposes by the North Carolina Radiation Protection Section. A copy of the program is on file with the Radiation Protection Section. LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE: Distribution: This device will be distributed as a generally licensed device in accordance with the requirements of 15A NCAC 11.0300 or equivalent regulations of the NRC or another Agreement State. The device may also be distributed as a specifically licensed device in accordance with applicable regulations of the State of North Carolina, the NRC, or another Agreement State. This shall not preclude the exportation of this device to a foreign entity, provided that the applicable NRC regulations are followed. Leak Testing: The device shall be leak tested by the user following the instructions in the "Manual of Operation and Instruction" at intervals not to exceed twelve months using techniques capable of detecting the presence of 0.005 microcurie of removable contamination. If the level of contamination exceeds this limit, the device shall be returned to Troxler for repair/disposal. Please note, Troxler maintains a customer leak test service. Servicing: The Model 3242 device contains no user serviceable components. The controller, containing the scaler and associated data analysis electronics, will generally be returned to Troxler for all servicing. The sample chamber, which holds the radioactive source, will be returned to Troxler for source replacement, servicing, repair and/or disposal. Operating and Safety Instructions: The device shall be operated in accordance with the written operating and safety instructions given in the device manual.

NO. : NC-646-D-135-B DATE: July 22, 2006 PAGE: 5 of 6 LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (continued): Reviewer Note: This registration sheet and the information contained within the references shall not be changed without the written consent of the North Carolina Radiation Protection Section, Radioactive Materials Branch. DOCUMENTATION: The documentation enclosed with the device upon shipment to the user shall include the following: 1. manual of operation and instruction, 2. special form certificate, 3. type "A" package testing results, 4. a copy of the final leak test results made prior to packaging, 5. an emergency response information sheet, 6. Model 3242 gauge certificate, 7 Troxler transportation guide. SAFETY ANALYSIS SUMMARY: The design of the 3242 gauge makes the devices safe to operate by persons not specifically trained in radiological safety. The inherent safety features of the device include: (1) a sealed source, doubly encapsulated, and secured into the device; (2) the use of shielding to attenuate the radiation to lower exposure levels; (3) the small sample chamber volume (10" x 7.5" x 4.5") precludes the operator from inadvertently being exposed, and (4) no user serviceable parts. The radiation profile for the device both shows relatively low radiation levels that are acceptable per federal regulations for exposure. Therefore, based on the information cited above and technical information provided in the application attachments, and with the condition that the licensee (i.e., user) maintain the gauge(s) in accordance with the manufacturer s recommendations and the requirements of this registry sheet, we conclude that the Troxler Model 3242, meets and exceeds the requirements to be manufactured and distributed as either a generally or specifically licensed devices pursuant to applicable regulations listed in 15A NCAC 11.

NO. : NC-646-D-135-B DATE: July 22, 2006 ATTACHMENT: 1 of 3 Attachment 1: Three Dimensional View of the 3242 Source Locations

NO. : NC-646-D-135-B DATE: July 22, 2006 ATTACHMENT: 2 of 3 Attachment 2: 3242 Gauge Source and Label Locations

NO. : NC-646-D-135-B DATE: July 22, 2006 ATTACHMENT: 3 of 3 Attachment 3: Radiation Profiles for 3242 Gauge Location 5 cm 30 cm 1 meter γ η γ+η γ η γ+η γ η γ+η Top.09 * 0.9 0.25 0.80 1.05 0.1 0.1 0.2 Bottom 0.45 * 0.45 0.2 0.45 0.65 0.1 0.1 0.2 Right 0.5 * 0.5 0.25 0.75 1.0 0.1 0.15 0.25 Left 0.6 * 0.6 0.2 0.85 1.05 0.15 0.10 0.25 Front 0.6 * 0.6 0.25 0.90 1.15 0.1 0.2 0.3 Back 0.4 * 0.4 0.2 0.55 0.75 0.1 0.1 0.2 Notes: 1. Radiation measurements were for a gauge containing a nominal and a nominal 0.100 millicurie Californium-252 neutron source. 2. All radiation measurements are in millirems per hour. 3. Gamma (γ) measurements were obtained with a Bicron RSO-5 survey meter, calibrated September 18, 1995. 4. Neutron (η) measurements were obtained with a Nuclear Research Corp. Model NP-2 survey meter, calibrated May 08, 1995. 5. * denotes measurement not made because center of detector volume was greater than 5 cm from source 6. See Attachment 1 for profile orientation.