ELECTRICAL SAFETY Information Bulletin

Similar documents
September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

ELECTRICAL SAFETY Information Bulletin

MOTOR FUEL DISPENSING SAFETY

PLBG/GAS SAFETY Information Bulletin

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

UltraTech International, Inc. Canadian Secondary Containment Requirements

Ethanol Vehicle and Infrastructure Codes and Standards Citations

LIQUEFIED PETROLEUM GASES

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY

Shop Fabricated Aboveground Tank Construction Standards

Fire & Explosion Risks in Service Stations

NFPA31FuelOilPiping 1 Revised

Installation Guidance: CNG Refueling Stations

How To Build A Two Hour Firewall In Calgary

The following definitions apply with regard to requirements specified in this document:

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Civil Engineering Sector Labour-Management Health and Safety Committee

OREGON FIRE CODE Interpretations and Technical Advisories

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Waste Oil Collection / Storage

Maryland Containment System Testing Protocol. The individual performing the inspection and testing as outlined in this protocol must be either:

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision)

Commercial Garages, Repair, and Storage

A Guide for the Homeowner/Builder

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Province of Alberta SAFETY CODES ACT PERMIT REGULATION. Alberta Regulation 204/2007. With amendments up to and including Alberta Regulation 99/2016

PERMITS REQUIRED & PERMIT EXEMPTIONS


Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS

Propane Autogas Fleets Safety & Training

Outdoor Storage of Raw Materials SC-33

ABOVE-GROUND STORAGE TANKS

Flammable and combustible liquids. Licence guide. Guide for operators

BP WIND ENERGY POLICIES AND PROCEDURES

Installation of Underground LP-Gas Systems

NFPA : Basic Requirements for Storage Tanks

Notes. Material 1. Appropriate Flammable Liquids

FIRE CODE INTERPRETATION

2014 British Columbia Building Code Changes

Recommended Fuel Piping Specification For UPP Piping, UL-971

Frequently Asked Questions

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Spray Booth Guideline

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

List of Frequently Utilized Storage Tank Standards and Practices

FLAMMABLE AND COMBUSTIBLE LIQUIDS

SECTION 105 PERMITS. 2. Fences not over 6 feet (1829 mm) high. 3. Oil derricks.

Spill Prevention, Control and Countermeasure (SPCC) Rule

Understanding Oil Tanks

Electrical Contractors. and the. New Jersey. Rehabilitation Code

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

Storage Tank Systems for Petroleum products and allied petroleum products regulations

FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

Safe Operating Procedure

SMOKY LAKE COUNTY. Title: Risk Control: Odorant-Mercaptan Policy No.: C Section: 14 Page No.: 1 of 12 E

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Sample Written Program. For. Flammable Liquids

WHEN IS A PERMIT REQUIRED?

INSTALLATION INSTRUCTIONS

FLAMMABLE AND COMBUSTIBLE LIQUIDS

SWIMMING POOL HEAT PUMP

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Design Safety Standards for Electrical Systems: Hazardous (classified) Locations -- OSHA Standard

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Name Of Occupancy Date. Yes No Describe

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Petroleum Storage Tank Compliance 101

Site and Storage Conditions for Class 3.1 Flammable Liquids

How To Safely Handle A Spill

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute

1. Site plans assist the Fire Department to determine where a potential spill can be contained. The detailed site plan shall include the following:

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

Technical Bulletin #2 : Inspecting Residential Solar Water Heating Systems

FLAMMABLE AND COMBUSTIBLE LIQUIDS

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Farm Fuel Tank Safety Guide

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

APPROVED. PXP 2009 Tank Leak Detection and Containment at Inglewood Oil Field. Baldwin Hills CSD Conditions L.18. and E.29.e.

Outdoor Liquid Container Storage

ADMINISTRATIVE SERVICES MANUAL

PERFORMANCE GUIDELINES

Title: Fuel Transport - Tank Truck

MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

Flood Risk Considerations

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

Building Permit, Fire Inspection and Operating Permit Fee Schedule

~~~~ Brian L. Harper, M.D., M.P.H. Commissioner of Health. Vito Minei, P.E. Director of Environmental Quality

APPENDIX G Materials Storage and Handling Guidelines

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

DIRECTOR S INTERPRETATION

How To Get A Flood Risk Reduction Rebate

COMPREHENSIVE PROPERTY INSPECTIONS

Flammable Liquids 29 CFR

Transcription:

ELECTRICAL SAFETY Information Bulletin January 2016 CEC-20 [rev-3] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 20 - Flammable Liquid and Gas Dispensing and Service Stations, Garages, Bulk Storage Plants, Finishing Processes, and Aircraft Hangars Gasoline Dispensing and Service Stations Rule 20-004 Hazardous Areas Rule 20-004(8) should not be interpreted as classifying the earth below the surface of the Class I, Zone 1 and Zone 2 areas around gasoline dispensing pumps as being a hazardous area. The rule stipulates that electrical wiring and equipment below the surface of areas defined as hazardous shall be considered to be within a Class I, Zone 1 location that extends to the point of emergence above grade. Therefore, electrical wiring extending from a pit or depression below the surface of the Class I, Zone 1 or Zone 2 hazardous area around gasoline dispensing pumps to the point of emergence shall be Class 1, Zone 1 wiring. Seals are to be located in accordance with the requirements of Section 18 for the hazardous location involved. See Rule 20-004 Issue of this STANDATA is authorized by the Chief Electrical Administrator [Original Signed] Clarence C. Cormier, P.Eng. Alberta Municipal Affairs Safety Services, 16 th floor, Commerce Place, 10155 102 Street, Edmonton, Alberta, Canada, T5J 4L4 Safety Codes Council, Suite 1000, 10665 Jasper Avenue, Edmonton, Alberta, Canada, T5J 3S9

Page 2 of 6 See Rule 20-004 (7) & (9) Outdoor Aboveground Gasoline Storage Tanks and Dispensing Some gasoline dispensing operations and service stations employ aboveground gasoline storage tanks. Industry has expressed concerns that Section 20 does not clearly identify hazardous area classifications in the vicinity of above ground gasoline storage tanks when used in conjunction with gasoline dispensing operations. Where a registered engineering professional has not classified an installation, the following guidelines may be used for the classification of outdoor aboveground gasoline storage tanks and dispensing operations:

Page 3 of 6 Location Zone Extent of Classified Area Tank interior 0 Area within the tank. (including interstitial space) Tank exterior 2 Area extending 3 m in all directions from the tank surface. (single and double walled tanks) Pumps, valves, manifolds etc. 2 Area within 3 m of a potential source of leakage. Underground tank fill 1 Area within the spill containment box. opening 2 Area within 3 m of tank fill opening extending upward to a level 450 mm above driveway or ground level. Aboveground tank fill 1 Area within a 900 mm radius of the fill connection or fill opening. opening 2 Area beyond the 900 mm extending to a radius of 3 m from the fill connection or opening Vent discharging upwards 1 The spherical volume within a 900 mm radius from the point of discharge. 2 The spherical volume between 900 mm and 1.5 m radius from point of discharge. Vent that does not discharge upwards The cylindrical volume below both the Zone 1 and Zone 2 locations extending to the ground shall be considered a Class 1 Zone 2 location. Spill containment / Dike 2 The area within the perimeter extending to the top of the spill containment. Dispenser Refer to Rules 20-002 to 20-014 Propane Dispensing, Container Filling, and Storage The Scope of this part of Section 20 does not cover consumer's propane storage tanks. For full information regarding these installations, consult your gas inspection authority. As a general guideline for electrical installations near consumer's propane storage tanks, the following applies: The area around a consumer propane storage tank is considered a Class I, Zone 2 hazardous location: (a) Within 3 m of a tank having a capacity of 125 USWG (over 475 L) to not more than 1000 USWG (3800 L); and (b) Within 7.5 m of a tank having a capacity in excess of 1000 USWG (over 3800 L). A "consumer" propane storage tank is a tank used to supply propane gas for propane burning appliances and equipment, and is not used for the purpose of transferring liquid propane to other containers.

Page 4 of 6 Commercial Repair Garages See Rule 20-102

Page 5 of 6 Bulk Storage Plants See Rule 20-202

Aircraft Hangars CEC-20 [rev-3] Page 6 of 6 Rule 20-400 Scope Although all aircraft hangers are considered to fall within the scope of this section, there are some cases where strict compliance is not warranted. For instance, small storage sheds used for private aircraft at private airstrips, flying clubs, and the like are not considered to present the same hazard as larger commercial hangers and often wiring methods outlined in Section 12 would be acceptable. For these types of facilities, please contact the authority having jurisdiction for assistance in determining an acceptable wiring method and to obtain any required variances. See Rule 20-402