Manual. RS232 Interface Tester. ipcas products. Data Respons GmbH

Similar documents
RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

USB Floppy USB Floppy Disk Emulator

RS-232 COMMUNICATIONS

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Advanced Data Capture and Control Systems

Manual Serial PCI Cards

USB Floppy Emulator V2 & Floppy Emulator SlimLine

Teleservice via RS232 interface XC100/XC200

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

TTL to RS232 Adapter User Guide

Cable Pinouts. SRP I/O Module

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Cable Specifications and Information

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

PCMCIA 1 Port RS EDITION OCTOBER 1999

BIS Automation Engine

1 Port FTDI USB to RS232 Null Modem Adapter

2 Port Industrial PCIe RS232 Serial Card with Power Output and ESD Protection

=============================== WARNING

Cabling Guide for Console and AUX Ports

Moxa TCC-100/100I User s Guide

XPort Universal Demo Board User Guide

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

USER GUIDE Programming Adapter Cable for Fujitsu Flash Microcontroller- F²MC-16LX/FR Family Fujitsu Microelectronics America, Inc.

RJ11 RS-232 Interface

VOICE RECORDING SYSTEM ISDN PRI / BRI

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

SyncLink GT2/GT4 Serial Adapter

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Cable Specifications and Information

Original instructions Tina 3A/Aps Adaptor unit

User Guide. HDMI Active Cable Extender. DVI-7370c

Testing PCI/ISA & PCMCIA Serial Cards

Tina 2A/B Adaptor unit

F2400 FOM II Series Fiber Optic Modem Technical Manual

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

Powerware Relay-Serial Card User s Guide

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

How to setup a serial Bluetooth adapter Master Guide

Cable Tester Pro ORDERCODE D1909

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

FOM-5A, 6A. Asynchronous Fiber Optic Modem

INSTALLATION INSTRUCTIONS

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

Elo Interactive Digital Signage (IDS): Remote Management

The Secrets of Flow Control in Serial Communication

Encore Controller to Router Connections

How To Use A Power Supply Unit (Upu)

K128. USB PICmicro Programmer. DIY Electronics (HK) Ltd PO Box 88458, Sham Shui Po, Hong Kong. mailto:

Modular I/O System Analog and Digital Interface Modules

Installation and User Guide

Comtrol Cable User Guide

Communication Unit 560CMU05 Data sheet

4 Port PCI Express RS232 Serial Card with Power Output and 15kV ESD Protection

RS-232 Cables, Wiring and Pinouts. Brief tutorial and pinouts for RS-232, T1/E1 and V.35. Contents

Installation & Configuration Manuel. Socket Server. OpenAT application

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Application Note 83 Fundamentals of RS 232 Serial Communications

Serial to Bluetooth Adapter

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

LwLVision-USB 2.0. Installation Guide

3-4 SAS/SATA II HDD Canister Deluxe version

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

isco Connecting Routers Back to Back Through the AUX P

Evaluation Board. i-modul and Socket. Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Model 1756 Test Lead Kit

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Making a DB to RJ45 adapter.

Advantium 2 Plus Alarm

1 Port RS232 Serial over IP Device Server

UPS Network Interface. Quick InstallationGuide

12 Volt 30 Amp Digital Solar Charge Controller

BroadBand PowerShield. User Manual

RS-232 to TTL Converter Cables SuperDroid Robots

WHQL Certification Approval...2 User Interface K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

User Manual IC-485AI

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

US Installation Manual Smappee Monitor

S/PDIF D/A Converter. User Manual. Rev.B, December 2011 Audial d.o.o Belgrade, Serbia

USB TO SERIAL ADAPTER

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Revision Date: September 19, 2006

NFC Communication Tray Model: HHX-IT3-Z

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation guide H A. HSI hardwired system interface

Dual Ports Serial PC Card User Manual

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

GMB HR84 GMM F346 TECHNICL MANUAL. grifo ITALIAN TECHNOLOGY. grifo Mini BLOCK Housing, 8 Opto Input, 4 Relay Outputs

Comfort Control Relay Panel (CCRP)

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

2/4/8 Port USB to Serial Adapter Hub with COM Retention

Transcription:

RS232 Interface Tester Manual ipcas products Permanent establishment Erlangen Data Respons GmbH Registered office Data Respons GmbH Data Respons GmbH Gundstraße 15 Amalienbadstr. 41, Bau 53 D-91056 Erlangen DE-76227 Karlsruhe Phone +49 9131 7677 100 Phone +49 721 480 887 10 Fax +49 9131 7677 78 Fax +49 721 480 887 11 Internet http://www.ipcas.com Internet http://datarespons.de E-Mail dr-de-erl-info@datarespons.com E-Mail info@datarespons.de www.ipcas.com

Contents Page Chapter 1: Introduction... 3 1.1 Scope of supply...3 1.2 Important Note...3 1.3 Special instructions...4 1.4 Important safety instructions...4 1.5 Make sure, that......4 1.6 Limited guarantee...5 1.7 Important warning and information symbols...6 Chapter 2: Presentation of the equipment... 7 2.1 General application...7 2.2 Connections...8 2.3 Light emitting diodes (LED s)...8 Red signal positive voltage level on signal line...8 green signal negative voltage level on signal line...8 DTS, DSR, TXD, RXD, RTS, CTS, DCD positive or negative voltage level at signal line of the same name...8 2.4 Jumper and pin rows...9 Chapter 3: Start-up... 10 3.1 Start-up...10 Chapter 4: Configuration... 10 4.1 Jumper settings...10 4.2 Connection 1 to 1...11 4.3 Modem Connection...12 4.4 Null modem connection...13 4.5 Loop-back...14 Chapter 5: Technical details... 14 5.1 Pin allocation of measuring contacts...14 5.2 Pin allocation of jumper rows...15 5.3 Pin allocation of RS232 SUB D plug/socket...15 5.4 Specifications...16 5.5 Glossary...17 Data Respons GmbH RS 232 Interface Tester V1.3 Page 2 of 17

Chapter 1: Introduction This manual describes how the RS232 interface tester developed by the company Data Respons GmbH ought to be used. You will find a current manual as a PDF or ZIP document on our website: http://www.ipcas.com/ 1.1 Scope of supply RS232 interface tester 10 jumpers Readme 1.2 Important Note COPYRIGHT 2014 Data Respons GmbH All rights reserved. No part of this document is allowed to be copied, reproduced, transcribed, or transferred in any other form without prior explicit written permission of Data Respons GmbH. No liabilities are accepted for possible printing errors, mistakes, or changes. All brand names or trademarks mentioned in this document serve the purpose of identification and as such are to be observed as the property of their respective owners. The author reserves all rights including the right to copy this manual completely or partially in any form, the right to change the contents of the product documentation as well as the right to technically change the product itself without prior notice. The warranty claim expires immediately if the product is changed, treated incorrectly or damaged intentionally or negligently, or if it is damaged by force majeure or used under conditions other than the ones prescribed. We cannot guarantee that changes to third-party equipment referred to in this manual will not affect the applicability of the information contained in this manual. CAUTION: Damage caused by inappropriate packing will not be borne by the forwarding agent / insurance company. Data Respons GmbH RS 232 Interface Tester V1.3 Page 3 of 17

1.3 Special instructions Use a dry cloth, only, to clean the operating panel and the casing. If the device is damaged, arrange for its immediate repair. If the damage has been caused by manipulation of the device, or if the device is opened by an unauthorized person, the guarantee and warranty claim expires. Please consult this user guide before you contact your vendor's customer service. During the warranty period, resorting to the customer service may also incur costs if the fault or problem was caused by the customer, and is remedied or cleared as described in this guide. 1.4 Important safety instructions As is the case with all electrical equipment there are some basic safety precautions you should observe at all times. These precautions apply primarily to your own safety, but also help to prevent damage to the device. Settings not described in this guide and changes to the device electronics should be carried out by an authorized vendor, only. Please read the user guide carefully and always keep it at hand. 1.5 Make sure, that... the device is never placed near a heater or the air outlet of an air-conditioning unit. the device is never exposed to direct sunlight. the device never comes in direct contact with liquids of any kind. Therefore, never use liquids in the vicinity of the device. Never perform any changes on the device that are not described in the user guide. This could damage the device and affect the warranty terms so that you might have to cover the costs for repairs. Data Respons GmbH RS 232 Interface Tester V1.3 Page 4 of 17

1.6 Limited guarantee Data Respons GmbH grants the end user (buyer) the guarantee that this product, if used correctly, will operate free of material damage and respective repairs for 24 months as of the date of sale. Upon showing the receipt and proving that a fault or flaw has been caused by inadequate workmanship or materials, Data Respons GmbH will repair or replace the entire product or respective components thereof free of costs within the warranty period, after deciding itself whether to repair or replace the product, and, respectively, do everything it finds necessary to restore the product s guaranteed functioning condition. As Data Respons GmbH sees fit the exchange includes the replacement with new or mint-condition devices or components corresponding to the original ones in scope and function. This guarantee expires immediately if the product is changed, operated incorrectly, intentionally or negligently damaged, or if it is damaged by force majeure or use beyond the permitted operating conditions. The buyer only has the right to repairs or exchange. No other entitlements exist. These guarantee conditions replace all other guarantees or warranty claims, whether explicit or implicit, and do not mean that the product can be merchandized for any particular purpose or used for commercial or any other purposes. Data Respons GmbH is not in any way responsible for indirect or any other primary or secondary damages the buyer might have to endure. Data Respons GmbH does not guarantee the hardware will conform to your requirements or that it will faultlessly. Upon installing the hardware, you accept the responsibility for its use including the results you expect, the installation, application, and the results achieved by its use. To claim the guarantee, consult your vendor who will then forward the defect device to Data Respons GmbH. If no receipt is added to the product sent in for repairs or if the warranty period has expired, Data Respons GmbH will repair or replace the product (according to its own discretion) and will charge the customer for parts and work time. Repaired or replaced products are sent back to the forwarding address. Data Respons GmbH RS 232 Interface Tester V1.3 Page 5 of 17

1.7 Important warning and information symbols Please observe all warnings and instructions displayed on the device itself and in the accompanying manuals. In the manual, warnings of particular importance are marked by the safety precaution symbols shown below. Warning and important information symbols NOTE: Text sections marked in this way contain important supplementary information or advice. WARNING - Damage: This symbol warns against possible damage to the device. Follow all instructions to avoid damage. CAUTION - Danger of injury: This symbol indicates a possible source of danger. Observe all safety instructions to avoid injury. CAUTION - Hot: This symbol indicates a possible source of danger. Observe all safety instructions to avoid heat-related injury. CAUTION - Current: This symbol indicates a possible source of danger. Observe all safety instructions to avoid injury through electrocution. Data Respons GmbH RS 232 Interface Tester V1.3 Page 6 of 17

Chapter 2: Presentation of the equipment 2.1 General application The RS-232 Interface Tester enables you to display all kinds of serial RS232 signals at an SUB-D9 interface. The tester is simply connected into the serial connections of devices or machines to test their operating parameters. Its two jumper blocks allow you to switch through various signals individually. Simple direct switching from 1:1 to Modem or Null modem as well as to a loop-back connection is made easy without any additional cables. The seven 2-color LED s show whether a line signal is active or not (high/low, + -). To permit measurements and performance testing at the machine/device interface during runtime (e.g. with multi-function measuring instruments, oscilloscopes, etc.), all socket pins of the RS 232 Interface Tester have been led out 1 to 1 at the input side onto a separate pin row from where they can be easily tapped. To ensure maximum protection we have supplied the RS 232 Interface Tester with suppressor diodes (signals against GND) and a decoupling capacitor (between screen and GND) at the output side, i.e. the Sub D plug (Fig. 2). The suppressor diodes offer overvoltage protection that is activated at signals of 18V or more. All these features have been compactly integrated onto a surface no larger than 4,5 by 9cm. Data Respons GmbH RS 232 Interface Tester V1.3 Page 7 of 17

2.2 Connections The RS 232 Interface Tester has two connections: RS232 SUB D9 socket RS232 SUB D9 plug On the casing lid, you will find the labels with the respective meanings of the LED s and measuring contacts. RS232 SUB D9 socket RS232 SUB D9 plug 2.3 Light emitting diodes (LED s) The LED s indicate the state of the respective signal lines and have the following meanings: All LED s can light up in both red and green. Red signal positive voltage level on signal line green signal negative voltage level on signal line DTS, DSR, TXD, RXD, RTS, CTS, DCD positive or negative voltage level at signal line of the same name Data Respons GmbH RS 232 Interface Tester V1.3 Page 8 of 17

2.4 Jumper and pin rows The RS-232 Interface tester can be configured with two jumper rows and has a diagnostic pin row: Jumper row for setting up null modem. (only with jumpered modem configuration.) Jumper row to switch through, cross, or interrupt signals. Jumper setting as "loop back dummy" for RTS/CTS, RX/TX or DTR/DSR is also possible. Pin row for measuring instruments (e.g. multi-function measuring instruments, oscilloscopes, etc.). Here pins 1 to 9 are tapped 1:1 by the RS232 SUB D9 socket. Data Respons GmbH RS 232 Interface Tester V1.3 Page 9 of 17

Chapter 3: Start-up 3.1 Start-up Make sure, that 10 jumpers are included in the scope of supply. Connect the equipment only if all jumpers are attached to their required positions. Do not change the jumper settings during runtime. Keep metallic or conducting objects away from the RS 232 Interface Tester. Short circuits not described in the user guide between different pins of the jumper blocks and the pin row and/or performing jumper allocations during runtime may lead to the damage of the interface to be tested as well as other connected devices. For this, we do not accept any liability. Chapter 4: Configuration 4.1 Jumper settings The following configurations are intended and can be used directly: 1 to 1 connection Modem connection Null modem connection Loop-back device Individual switching of signals (on/off) Data Respons GmbH RS 232 Interface Tester V1.3 Page 10 of 17

4.2 Connection 1 to 1 All jumpers of the 8-fold jumper row are attached to the left. The two-fold jumper row must remain empty. DCD RX TX DTR DSR RTS CTS RI The signals described in the diagram are connected 1:1 and fully assigned. This configuration corresponds to a standard cable with the following allocation: Data Respons GmbH RS 232 Interface Tester V1.3 Page 11 of 17

4.3 Modem Connection All jumpers of the 8-fold jumper row are attached to the right. The two-fold jumper row must remain empty. DCD RX TX DTR DSR RTS CTS Ri nc TX RX DSR DTR CTS RTS nc The signals described in the diagram display the combination between SUB D socket and plug. This configuration corresponds to a cable with the following allocation: If required, the lowest jumper can be attached on the left in order to connect the Ring Indicator. Data Respons GmbH RS 232 Interface Tester V1.3 Page 12 of 17

4.4 Null modem connection All jumpers of the 8-fold jumper row are attached to the right. The two-fold jumper row is fully assigned. DTR out DCD in (jumpers DCD and DSR at the SUB D9 socket) DTR in DCD out (jumpers DCD and DSR at the SUB D9 plug DCD RX TX DTR DSR RTS CTS Ri nc TX RX DSR DTR CTS RTS nc The signals described at left in the diagram are connected with the signals to the right. This configuration corresponds to a cable with the following allocation: Data Respons GmbH RS 232 Interface Tester V1.3 Page 13 of 17

4.5 Loop-back Three jumpers of the 8-fold jumper row are attached into the center. The two-fold jumper row must remain empty. RX-TX DTR-DSR RTS-CTS The signals described in the diagram are jumpered with one another at the input side. Chapter 5: Technical details 5.1 Pin allocation of measuring contacts The measuring contacts, their numbers and descriptions correspond to the RS232 SUB D9 socket and are directly connected with it. 1 2 3 4 5 6 7 8 9 DCD RXD TXD DTR GND DSR RTS CTS RI Data Respons GmbH RS 232 Interface Tester V1.3 Page 14 of 17

5.2 Pin allocation of jumper rows The information added to the pins corresponds to the numbers of the SUB D9 plugs and sockets. SUB D plug SUB D socket SUB D plug DCD Pin 1 (DCD) leer Pin 1 (DCD) Pin 6 (DSR) SUB D9 socket RX Pin 2 (RXD) TX Pin 3 (TXD) Pin 3 (TXD) Pin 2 (RXD) Pin 2 (RXD) Pin 3 (TXD) Pin 1 (DCD) SUB D9 socket Pin 1 (DCD) SUB D9 plug DTR Pin 4 (DTR) DSR Pin 6 (DSR) RTS Pin 7 (RTS) Pin 6 (DSR) Pin 4 (DTR) Pin 8 (CTS) Pin 4 (DTR) Pin 6 (DSR) Pin 7 (RTS) Pin 6 (DSR) SUB D9 plug CTS Pin 8 (CTS) RI Pin 9 (RI) Pin 7 (RTS) empty Pin 8 (CTS) Pin 9 (RI) (read in sequence of pins from top to bottom) Any arbitrarily desired combination is optionally possible with customary cables (not included in the scope of supply). However, we do not offer any statement of assurance or guarantee for these optional configurations and do not accept any liability for them. 5.3 Pin allocation of RS232 SUB D plug/socket RS232 SUB D9 socket: RS232 SUB D9 plug: Data Respons GmbH RS 232 Interface Tester V1.3 Page 15 of 17

5.4 Specifications RS-232 Interface-Tester Specifications 1 x RS232 SUB D9 socket (fully assigned) Interfaces 1 x RS232 SUB D9 Plug (fully assigned) Pin row for measuring instruments DTS, DSR, TXD, RXD, RTS, CTS, DCD, Diagnostics LED s each 2-colored, (green/red) for displaying the voltage level (+/-) Voltage supply RS232 interface Casing Plastic casing Measurements W/H/D Approx. 42/20/93 mm Operating/Storage temperature 5 C to 55 C / -10 C to 70 C Relative humidity 5 % to 90 %, non-condensing Overvoltage protection at a signal level of 18V or more due to suppressor diodes at each Overvoltage protection signal line against GND. Screen-lateral overvoltage protection through capacitor RS 232 Interface Tester Scope of supply 10 jumpers Readme Purchase order number 0202021 Data Respons GmbH RS 232 Interface Tester V1.3 Page 16 of 17

5.5 Glossary TXD RXD RTS CTS DSR DTR DCD DCE DTE PC SUB-D9 RS232 NC Transmit Data Received Data Request To Send Clear to Send Data Set Ready Data Terminal Ready Data Carrier Detect Data Communication Equipment Data Terminal Equipment Personal Computer Sub-miniature Type D Recommended Standard 232 (standardized serial interface) Not Connected ipcas products Data Respons GmbH Permanent establishment Erlangen Registered office Data Respons GmbH Data Respons GmbH Gundstraße 15 Amalienbadstr. 41, Bau 53 D-91056 Erlangen DE-76227 Karlsruhe Phone +49 9131 7677 100 Phone +49 721 480 887 10 Fax +49 9131 7677 78 Fax +49 721 480 887 11 Internet http://www.ipcas.com Internet http://datarespons.de E-Mail dr-de-erl-info@datarespons.com E-Mail info@datarespons.de Data Respons GmbH RS 232 Interface Tester V1.3 Page 17 of 17